17C-282 (8) 18 LILLY ST BP-2016-1232
GIs #: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 17C-282 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: SOLAR PANELS BUILDING PERMIT
Permit# BP-2016-1232
Project# JS-2016-002120
Est. Cost: $18000.00
Fee: $75.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: TORRICO ELECTRIC LLC 97422
Lot Size(sq.ft.): 16857.72 Owner: HOOKER MICHAEL D&JEANNE M SCHUBMEHL
Zoning: URB(100) .Applicant: TORRICO ELECTRIC LLC
AT. 18 LILLY ST
Applicant Address: Phone: Insurance:
63 WEST ST (413) 528-0010 Workers Compensation
MT WASHINGTONMA01258 ISSUED ON:4/27/2016 0:00:00
TO PERFORM THE FOLLOWING WORK.INSTALL ROOF MOUNTED 4.4KW SOLAR
ARRAY - per Chris Vreeland engineering dated 3/17/16
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 4/27/2016 0:00:00 $75.00
212 Main Street,Phone(413)587-1240,Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner
File# BP-2016-1232
APPLICANT/CONTACT PERSON TORRICO ELECTRIC LLC
ADDRESS/PHONE 63 WEST ST MT WASHINGTON01258 (413)528-0010
PROPERTY LOCATION 18 LILLY ST
MAP 17C PARCEL 282 001 ZONE URB000)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE 17)
!i
ZONING FORM FILLED OUT s
Fee Paid �� „
Building Permit Filled out
Fee Paid
Typeof Construction: INSTALL ROOF MOUNTED 4AKW SOLAR ARRAY
New Construction
Non Structural interior renovations
Addition to Existing '
Accesso Structure
Buildin Plans Included:
Owner/Statement or License 97422
3 sets of Plans/Plot Plan doi
THE FOLL WING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFO TION PRESENTED:
pproved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§
Intermediate Project: Site Plan AND/OR Special Permit With Site Plan
Major Project: Site Plan AND/OR Special Permit With Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission Permit DPW Storm Water Management
o it' el y
Sig re ui ding ficial_ Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
* Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of
Planning&Development for more information.
_ -- Department use only
'ty of Northampton Status of Permit:
B ilding Department Curb Cut/Driveway Permit
�►pR 12 Main Street Sewer/Septic Availability
- ;ys Room 100 Water/Well Availability
orthampton, MA 01060 Two Sets of Structural Pians
phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans
Other Specify
APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING
SECTION 1 -SITE INFORMATION
1.1 Property Address: _ This section to be completed by office
Map Lot Unit
„ Zone Overlay District
Elm St.District CB District
SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT
2.1 Owner of Record:
Name(Print) Current Maim g Address.
Telephone
� Signature
2.2 Authorized Anent:
" �_ ! ( \ C'7 �# 4. - �`"<•�j!i.(�}'�d'ri.� �� '; c a�5
Name(Print) Current Mailing Address:
Signature Telephone
SECTION 3-ESTIMATED CONSTRUCTION COSTS
Item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building '( �� (a)Building Permit Fee
Do
2. Electrical i 4 N10
(b) Estimated Total Cost of
f Construction from 6
3. Plumbing Building Permit Fee
4. Mechanical (HVAC)
5. Fire Protection
6. Total=0 +2+3+4+5) Check Number
�--` This Section For Official Use Only
Building Permit Number: Date
Issued:
Signature:
Building Commissioner/Inspector of Buildings Date
Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information
Existing Proposed Required by Zoning
This column to be filled in by
Building Department
Lot Size
Frontage
Setbacks Front
Side L: R: L: R:
Rear
Building Height
Bldg.Square Footage %
Open Space Footage %
(Lot area minus bldg&paved
parking)
#of Parking Spaces
Fill:
(volume&Location)
A. Has a Special Permit/Variance/Finding ever been issued for/on the site?
NO 0 DONT KNOW YES C)
IF YES, date issued:
IF YES: Was the permit recorded at the Registry of Deeds?
NO 0 DONT KNOW 0 YES 0
IF YES: enter Book Page and/or Document#
B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW
?0\
YES
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained 0 Obtained 0 , Date Issued:
C. Do any signs exist on the property? YES 0 NO
IF YES, describe size, type and location:
D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO
IF YES, describe size, type and location: Y'
E. Will the construction activity disturb(Gearing,grading,V2Spavation,or filling)over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES 0 NO
IF YES,then a Northampton Storm Water Management Permit from the DPW is required.
SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable)
I New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑
Or Doors L]
Accessory Bldg. EIDemolition ❑ New Signs [CI] Decks [p Siding[0] Other[
Brief Description of Proposed
Work
-� �
` �r� � {
Alteration of existing bedroom Yes_ No Adding new bedroom Yes 1" No
Attached Narrative Renovating unfinished basement Yes No
Plans Attached Roll -Sheet
sa. If New house and or addition to existing housing, complete the followin% r
...
a. Use of building:One Family Two Family Other
b. Number of rooms in each family unit: Number of Bathrooms
c. Is there a garage attached?
d. Proposed Square footage of new construction. Dimensions
e. Number of stories?
f. Method of heating? Fireplaces or Woodstoves Number of each
g" Energy Conservation Compliance. Masscheck Energy Compliance form attached?
h. Type of construction
i. Is construction within 100 ft of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No
j" Depth of basement or cellar floor below finished grade
k. Will building conform to the Building and Zoning regulations? Yes No.
1. Septic Tank City Sewer Private well City water Supply
SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
1 = as Owner of the subject
property
hereby authorize
to act on behalf,in all matters relative to work authorized by this building permit application.
Signature of O r Date
as Owner/Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
Print 10m-e.
Stgr ature of Owner/ Date
SECTION 8-CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor: Not Applicable ❑
Name of License Holder:�'lowas �.��^(7 i�"� 1 (_ 1 �"0 bl1 -3" `I -2-2--
License Number
AddrRSS\ Expir ion Da
l - "Ly + 3 ooQd
Si ature Telephone
9.Registered Home Improvement Contractor: Not Applicable ❑
Company Name Registration Number
to V) \N�PS+ c . 14,4yqak'l 1`7�n , V�4, C' Z S t 1 2701 701 1:7-
Address Expi ation D to
Telephone,413 5 Z�00 OQ
SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes....... No...... ❑
11. - Home Owner Exemption
The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families
and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts
as supervisor.CMR 780, Sixth Edition Section 108.3.5.1.
Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there
is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm
structures.A_person who constructs more than one home in a two-year period shall not be considered a homeowner.
Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be
responsible for all such work performed under the buil(line permit.
As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon
completion of the work for which this permit is issued.
Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153(Liability of Employers to
Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s)
you hire to perform work for you under this permit.
The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of
Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated.
Homeowner Signature
The Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
5 1 Congress Street, Suite 100
ow; Boston, MA 02114-2017
www mass.gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Applicant Information ) Please Print Legibly
Com
Name (Business/Organization/Individual): �r�l f C7 ��PCY l C .-Ear
Address: �?j Q -} S4
City/State/Zip:� �f QlZS Phone #: �l ,�j Ar00 16)
e you an employer? Check the propriate box: Type of project(required):
1.;A I am a employer with�� 4. ❑ I am a general contractor and I
employees (full and/or part-time).* have hired the sub-contractors 6. F-1 New construction
2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling
ship and have no employees These sub-contractors have g. ❑ Demolition
working for me in any capacity. employees and have workers' 9. ❑ Building addition
[No workers' comp. insurance comp. insurance.$
required.] 5. ❑ We are a corporation and its 10.El Electrical repairs or additions
3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions
myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs
insurance required.] t c. 152, §1(4),and we have no 13 Other
employees. [No workers'
comp. insurance required.]
*Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
:Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site
information.
Insurance Company Name: I On
Policy#or Self-ins. Lic. #: y V S TL- Li 9 IRI(p Expiration Date:, - QZ_ f
Job Site Address: l[U ; ❑(>r, ���� Qt LI City/State/Zip:
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby ci rC under t pans and penalties of perjury than the information provided above is true and correct.
Si ature: �` "_�' Date: Ll&
Phone#: 4J 3 ,t_—2- • 00 10
Official use only. Do not write in this area,to be completed by city or town official.
City or Town: Permit/License#
Issuing Authority (circle one):
1.Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector
6.Other
Contact Person: Phone#:
City of Northampton 212 Main Street, Northampton, MA 01060
Solid Waste Disposal Affidavit N I A - no OU� S
In accordance of the provisions of MGL c 40, S54, I acknowledge that as
a condition of the building permit all debris resulting from the construction
activity governed by this Building Permit shall be disposed of in a properly
licensed solid waste disposal facility, as defined by MGL c 111, S 150A.
Address of the work:
The debris will be transported by: tj
The debris will be received by:
Building permit number:
Name of Permit Applicant
Date Signature of Permit Applicant
Inspection Report PO Box 179
West StockbridLe.NIA 01266
413-269-4965 -
cjv,i�precdec.com
To: Building Inspector, Town of Northampton.MA
CC: John Ward, Solar Store of Greenfield
From: Chris Vreeland, Precision Decisions LLC
Date: March 17.20 16
Re: 18 Lillv Street, Florence. MA- Inspection of Residential Structure for Solar PV
This letter summarized the inspection and analysis of the residence at 18 Lilly Street. Florence, MA to determine
if the structures are adequate to support roof mounted solar PV systems.
An inspection of the roofs and supporting structures were performed on March 15, 2016.The main roof of the
house(ridge running�cest to east) is constructed of rouh? X 6 rafters on 19 to 21 inch centers. These were
measured and analyzed for the additional dead load of two rows of solar PV panels;each row of modules being
mounted on two rails that are attached with mounting feet. Based on the anatvsis,the ratters will need to be
reinforced to support the increased dead load from the PV array as well as the fact that the loads will now be
concentrated at the points of mounting. The reinforcement recommended is to install(sister)one 2 X 6 against
each existing 2 X 6(see photo of similar job). The new 2 X 6s are to be-2 SPF or better and are to be attached by
two rows of 16d X 3"nails. 8" on center.staggered. The are fifteen rafters that need to be sistered and they are
nominally 14' Ion-. J he nvo gable end rafters do not nerd upgrades. The reinforcing is to occur prior to
installation of the arrays and with no snow or other live'loads on the roof.
/_rcurrplrof sistere t rniter.pictured in erenvrhjrd ra/ter m _h:rt this/rr•olect ticill uperade f VER) ra ter.
The solar rnounting feet are to be staggered and
spaced so that the loadinu is evenly distributed
between the rafters."Thus, if mounting feet occur-
every
ccurevery 4 feet of rail then there would be two t
mounting feet per ratter(for the 4 rails that make
Lip the tNvo rows).
It is my professional opinion• based on my review
and inspection,that the installations of the solar "
PV sv stems as proposed.meet the minimum ,
criteria of the Massachusetts State Buildine Code
?80 CMR Eighth Edition.
orris �'reefand
Chris Vreeland, PE
IRONRIDGE Roof Mount System
v
{
t�
IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit
and proven in extreme environments.
Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and
is also why our products are fully certified, code compliant and backed by a 20-year warranty.
Strength Tested PE Certified
All components evaluated for superior Pre-stamped engineering letters
structural performance. available in most states.
Class A Fire Rating Design Software
Certified to maintain the fire resistance Online tool generates a complete bill of
rating of the existing roof. materials in minutes.
Integrated Grounding 20 Year Warranty
UL 2703 system eliminates separate Twice the protection offered by
module grounding components. competitors.
XR10 Rail XR100 Rail R1000 Rail Internal Splices
A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices
for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections.
• 6'spanning capability 8'spanning capability • 12'spanning capability - Self-tapping screws
• Moderate load capability Heavy load capability • Extreme load capability • Varying versions for rails
• Clear anodized finish Clear& black anod. finish • Clear anodized finish • Grounding Straps offered
ashFoot Slotted L-Feet Standoffs Tilt Legs
Ala,
1 1"
Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired
with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees.
• Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail
• IBC& IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware
• Certified with XR Rails Clear& black anod. finish Lengths from 3"to 9" Fixed and adjustable
nd Clamps %ending Mid Clamps T Bolt Grounding Lugs Accessories
-- -
Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and
modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails.
• Mill finish &black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips
• Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps
• Optional Under Clamps Mill &black stainless Swivels in any direction UV-protected polymer
Design Assistant NABCEP Certified Training
Go from rough layout to fully Earn free continuing education credits,
engineered system. For free. while learning more about our systems.
DC..,k L6 rnP-,k 1 P
I �
i
421r
i
F I
-- 112.1( t(yr. �L'r tjatr Yzlr yzrr (211
if I
18 Lilly Street Florence, MA
%"spacing
spacing
Rails will be 12" in from top and bottom of the
modules. Mounting L-feet will start at the first
available rafter underneath the end modules in
each row and be every 4' thereafter. They will
be staggered to evenly distribute the load
throughout the roof.
Utility
i
Utility
Revenue Jeanne Schubmehl
meter 18 Lilly St
�f Florence, MA 01062
Acct# 28393-11038
100 A Meter # 25028510
SolarEdge mike@elderlawservice.com
14 LG 315W SE 3800-US
Modules Inverter kWh ___
Main service
-- Production --
With panel
1 str 14 DC meter
disconnect
20 A PV
i
I I
Building Loads
john@solarstoreofgreenfield.com
solar=a@
SolarEdge Single Phase Inverters
For North America
SE3000A-US / SE380 - / SE5000A-U / SE6000A-U /
SE7600A-US / SE10000A-US / SE11400A-US
I
ro®rre,
,12.25
A
m Veatg
Warrant; � E.
i
P
fir.
i
The best choice for SolarEdge enabled systems
Integrated arc fault protection (Type 1)'for NEC 20111690,11 compliance
Superior efficiency(98%)
Small,lightweight and easy to install on provided bracket
Built-in module-level monitoring
Internet connection through Ethernet or Wireless
Outdoor and indoorinstallation
Fixed voltage inverter, DC/AC conversion only
— Pre-assembled Safety Switch for faster installation `
Optional—revenue grade data,ANSI 012:1
USA-GF ftMA'dY-I "A Ly-FRAM CE-JAIP N CH1N A:Q T RA LIA-TH" ! s}ETH IRLAN S-iS RA EL wwVv solaredge.us
solar=@@ Single Phase Invertersfor North America
SE300OA-US l SE380OA-US f SE5000A-US/SE600OA-US/
SE7600A-US/SE10000A-US/SUP 140OA-US
SE3000A-US € SE380OA-USi SE5000A US [ SE6000A US SE7600A US l SE10000A US SE11400A US
OUTPUT
Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V - 11400 -VA
... ...... .... ..... .... ....<.. 10C?0
..... .. ��240V
i 5400 @ 208V 03 0 208V
Max.AC Power Output 3300 4150 6000 8350
5450. 2rC?. ............... 1�g50 240V I
AC Output Voltage Min.Nom.Max '! .. .....
12000 V
A
183 208 229 Vac ✓ ✓
f
„
AC Output Voltage Min.-Nom.-Max."' 1,,.... I
211 240 264 Vac ✓ ✓ '� ✓ ✓
AC Frequency Min.-Nom.-Max." -- ....,.5a 3 60 60.5(with HI county{ etting 57 60 60.5) Hz
...... ...
(
Max.Continuous Output Current 12.5 24 @ 208V 48 @ 208V 16 25 32 € 47.5 A
.. .,..- 21(d 240V .............. ...4t..�"a 240V
GFDI Threshold 1
....... A.
Utility P,fanitonng,Islanrling Protection,Country Configurable Thresholds Yes Yes
INPUT
MaXlmumDCPOwer(STC) 4050 510Q 6750 [ 8100 102 i0 13500 153;0W
„ ... .,... ., ................. ...............
Transformer less,Ungrounded
.
ed
................ . ..........
Max.Input Voltage
e.............. 500 [ ..Vdc
Nom.DC Input Voltage ..... 325 @ 208V;350 @ 240V
16.5 Vd�
}.. ....
208V ......... 3
Max.Input Cur ren 9.5 13 lg 208V 34.5 Adc
,2
15 to 24 V, I............... 1..303f�-240V., ..,,
Max.Input Short Circuit Current 45
Adc
Reve se Polarty Pretec tion Yes
Ground-Fault Isolatian Detection k„ `
...,..... 6L(k Se
..Maximum Inverter Efficiency 97.7 98.2 98.3 98,3 Sensitivity
98 cq ag
tv...
97,5 @ 208V �7�a 208V
EC Weighted Efficiency 97.5 34 37.,7 n7 7 97.5
5
................. 98.P 40V
1, 97.5,@ 240V
Nighttime ttime Power Consumption
,2,5
<4 W
ADDITIONAL FEATURES
Supported Comrrunicahon Interfaces RS485,RS232,Ethernet,ZigBee(optional)
Revenue Grade Data,ANSI 1 Optional
....... .. ..... .................... . ................ .... ..... . .. ....._.
Rapid Shutdown-NEC 2094 690.12 Functionality enabled when SolarEd e rapid shutdown kit is installed" "
STANDARD COMPLIANCE -
Safety U,L1741,UL,16199B,,.UL1998, ,CSA 22.2
.,
Grid Connection Standards rEE 547
Emissions FCC partly class B
INSTALLATION SPECIFICATIONS
AC output conduit size/AWG range3r'4"minimum 16-6 AWG
3i4"rr. . .. . .... ....strings.J ... . .166A ... . ,. 3/4 rrimmum/83ALM1gs
DC input conduct size/#of strint s I .. . J 3 4"rr nimum/1 2 strings J I
laWG,rang ..................... S4 6....
Dimensions with Safely ....
Swtc, 30.5x12.5x10.5J n/
HxWxD
30 x12.5x7.2/775x31Sx184 775,x 315 x 260 rnm
tNeight with Safety Switch S1 2 J 23.2 5 4.7 J 24.7 88.4/40.1 b/kg
Natural
convection
Cooling Natural Convection and internal Fans(user replaceable)
fan(user
Noise `LS ..............
O1 re�lacAat�ie
SO dBA
Min.Max.Operating Temperature -13 to+110; 25 to+60 -40 to+60 version available�'I)
Protection Rating NEMA 3R
...................................
. ........ ........... _-,........._....-._,.. ....... ...,.<
Fcr the.!egi:;nal settings please contact.,cla.Cdge support
"A higher current source may be aced;the inverter will I;init its input current to the value,stated.
"Revenue grade invnr r RN:SExx A-USOCONNR2 ifcr 7600W invert,-SE76WA-US002NN192.
Rapid shutd—n kit.P,/N:Se'1000-RSD-51. )
�s!40 version P/N:SCxxxxA USOOONN04(for 7600W,nV,.rtecSE7600A-US002NNU4i.
I }SLnsPEC •
�• 1
M AVIV*
Uj
Life's Good
s i
LG
V
LG's new module,LG NeCM'2,adopts Cello technology.
Cello technology replaces 3 busbars Guth 12 thin wires POVE,P ,rCI
to enhance power output and reliability.LG NeCN'I`2 AV Ado
c
60 cleAl de€�,0f15t('ateS LGs efforts to increase CUSiGl73e!"'s Va',GeS .:,:: us ,rc: �
beyond efficiency.it features enhanced warranty,durability, Intertek FFTJJJ 1
Yf 1 CEN 61'IS
performance under real environment,and aesthetic
design suitable for roofs.
Enhanced Performance Warranty High Power Output
3 LG Ne{JPS' 2 has ar,enhancederfcrrrlance+varranty, g,_ Corr.pared with areviuus models,the LGeONT"2
The annual degradation has fallen from-0.7%/yr to has been designed to significantly enharce its output
-0.:59/6fyr.Even after 25 year's,the cell guarantees 4'%p � efficiency,thereby making it efficient even in limited space.
mare output than the previous LG NeGNI`modules.
Aesthetic Roof _ Outstanding Durability
" rte
Itsg ..G NeUN'r''2 has beer-:des;oned with aesthetics in mind; With its newly reinforced frame design,f..G has extended
thinner J•ires chat appear al blacK at a distance, thy=warranty cf the LG NeON—2 foram adc'morai
The nrocuct rr.a heir creme e v is ,
Y a..e o* 2 years.Addlticna(iy,t_G IteO,'� .ca::enure a front
p oce.ywi h is modeal design. load up o 6000 Pa.,a,-,d a rear load up to 5.4 7 Fa.
i s r
Better Performance on a Sunny Day j Double-Sided Cell Structure
1 G.NeGN" 2 r7c4v performis better on sunny days than ` The rear:,`the ceu used in LG erON'r�2 wi ..
rcntribute to
to its improved temperature coefficiency, generation,lust`like the front;the Gcl1t beam reflected From
the rear c`-he rrlodule is reabsorbed to generate a great
amount of additior;a power-
About LG Electronics
(jt,Al p'.)er h .:,a5 er c orn:r..it Coe" :7 r I. - •a_. ( eri:n lar e-e:gy s,ne,;ta it� to:ng .r,g ne. Pcalx,., 1 ,r, r:e. s' P.Barrnp qar:,In
SS a parted ,nip t xp e it LTi c�ndu-.� .CJ he..:istry a d matyndu t:y
we n fL Iv r,cased*ne h hvtun x .ies to the-nar:<t i 10 G h v.which e erported to 32
LG L.+ BEE=
Mechanical Properties Electrical Properties(STC
ceils6 ,,lu Module Type 315 W
-
-- ---------------------- ................. ..............................----.........................-.--.............
Cell Vendor LG MPP Voltage(Vmpp)
.............. ............................................................ .............................................. ..........-.............-
Cell Type Mr3nocrvst--0'1r--(,/N-'.' 0. MPP Current(Impp) 9,50
............-- ................... ............ .......................
......................... ............ ...................-
Celt Dimensions 156.75 x 156.7/5 mnn 6 nches Open Circuit Voltage(Voc) 40,6
.....................-............................................... .......................... ....................... .............
of Busbar 12(M u l:::;;,,'ire:f,6 Us 1)a0,0, '10, Short Circuit Current(Isc) 10.02_
----.............................. ............ ........................... .............-.11....................
Dimensions(L x W x H) 1640 x 1000 x 40 n.,rn Module Efficiency(%) 19.2
64.57Y,--)�37, 7.1 ch Operating Temperature('C) -40-'90
.......... ....................... .............................................................
Front Load 600o Pa/12S 7sf 0 Maximum System Voltage(V) 000
........... .......................... ..........
Rear Load 5400 P-�I"I 13 psf 0 Maximum Series Fuse Rating(A-)....... ..................... 2-0------- ........... ...........
Weight 1 TO t 0.5 kg/374'G t 1.'Ibs Power Tolerance 0-3
CormectorType MC4,NICO Compatible,IP67 :-C Snr—rd,e".
.............. .................. ......................... Id:;r�t!10 X-0j,"I",M 2 5 AM 1.
Junction Box IP67 with 3 Bvoass Diodes
............... .......... etv'g�-j rh—j, ewc'-'rya 20, 11r,1-V, 2.0",'
Length of Cables 2 x 1000'mm i 2 x 39 3?in:h
Glass 111 g h Trar.s m i ss;oin Te'-.-pe red G I ass
Frame Anodized Aluminum. Electrical Properties(NOCT*)
Module Type 315 W
Certifications and Warranty
Maximum Power(Pmax) 230
Certifications IEC 612115,IEC 6 1 730-U-21 MPP Voltage(Vmpp) '30,11
...............---------------------- ------- ............. .........................--................. .................
IEC 6271-6"Ammonia MPP Current(Impp) 7.58
IEC F,1701(Sak M<t Corrosion Test), Open Circuit Voltage(Voc) 37.6
-.....................I-L-_- ............
IS09001 Short Circuit Current(Isc) 8,03
0:-170- NIX-) 200 Ovhn�,arrib-Ir temn—t—2 1
Module Fire Performance(USA) Type-1 ILA.1703)
---.- ..............- ---- .......... ............... ..................I -I--- ...........
Fire Rating(for CANADA) r0a>C(ULC/OR C 170 3) Dimensions(mm/in)
Product Warranty 12 vers
Output Warranty of Pmax
2)Aft..-J.Id
Temperature Characteristics i
.......... ..........................
NOC`r 46
Pm ..pp 1111f'-C 0
Voc
.................. .................... ------..............................----............ ..........
Isc 1.E C
Characteristic Curves
WOW
0
..........................................
............ ---------3...............
....................... ..............
2
P—
Iii i
51
Prldutspc, argevithout notic',--
LG Lc e,ron'I Inc j .Y-NI 'u4
Jfi,'s Good
G.fret 11 S Elec-ron.,.s.All h,reserved, Innovation for a Better Life
Ct'
Power Optimizer Specifications—P3001 P350 P400 P405 solar=* *
Power Optimizer Specifications - P300 / P350 / P400 / P405
P301D P350 P400 P408
INPUT
Rated Input DC Power") 300 350 400 405 W
Absolute Maximum Input Voltage(Voc) 48 60 80 125 Vdc
MPPT Operating Range 8-48 8-60 8-80 12.5-105 Vdc
Maximum Short Circuit Current(Isc)of connected PV Module 10 Adc
Maximum DC Input Current 12.5 %
Maximum Efficiency 99.5 %
Weighted Efficiency 98.8
Overvoltage Category II
OUTPUT"DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPE
E#ATINC INVERTER)
Maximum Output Current 15 Adc
Maximum Output Voltage 60 85 Vdc
OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)
Safety Output Voltage per Power Optimizer 1 Vdc
STANDARD COMPLIANCE
EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(class II safety),UL1741
Material UL-94(5-VA),UV Resistant
RoHS Yes
INSTALLATION SPECIFLCATIONS
Maximum Allowed System Voltage 1000 Vdc
Dimensions(WxLxH) 141 x 212 x 40.5/5.55 x 8.34 x 1.59 mm/in
Weight(including cables) 950/2.1 g/Ib
Input Connector MC4/Tyco/Amphenol
Output Wire Type/Connector Double Insulated;Amphenol
Output Wire Length 0.95/3.0 1.2/3.9 m/ft
Operating Temperature Range -40-+85/-40-+185 °C/OF
Protection Rating IP65/NEMA4
Relative Humidity 0-100 %
M Rated STC power of the module.Module of up to+5%power tolerances allowed
PV SYSTEM DESIGN USING',SOLAREDGE INVERTER SINGLE PHASETHREE PHASE 208V THREE'.PHASE '.
Minimum String Length(Power Optimizers) 8 10 18
Maximum String Length(Power Optimizers) 25 25 50
Maximum Power per String 5250 6000 12750 W
Parallel Strings of Different Lengths or Orientations Yes
So/ar£dge Power Optimizers
Solar- • • "= Power Optimizer Specifications—P300 I P350 I P400 I P405
I.. ...........�
,
1,
o v,
iA»•�•Ns°r�i#iAi•i �
rA�•OAO•OAA#AMAw•� �
A A • AAAA A
E i� �i I•
I I
i
lj
II ! U
a
OUTPUT INPUT
MAN-01-00144-1.3
SolarEdge Power Optimizers