813 Septic Application Permit Compliance & Plans THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH City of Northampton oration for Marko Lonstrurtion Permit pplication is hereby made for a Permit to Construct ( X) or Repair ( ) an Individual Sewage Disposal t: Florence Road 4 f Al 6 Ress -Route 66, Wesfhld ton, MA FEB oar. CO 9 CHECK OR FILL IN WHERE APPL Owner Address / Installer V Address e of Building Size Lot....12.,.fi0.0 Sq. feet Dwelling—No. of Bedrooms 2 Expansion Attic ( X) Garbage Grinder (X) Other—Type of Building No of persons Showers ( ) — Cafeteria ( ) Other fixtures Design Flow 55 gallons per person per day. Total daily flow 440_- 1• 5=660 gallons. Septic Tank—Liquid capacity1.510.Ogallons Length Width Diameter t }}-- -ingarem .� �65 d Disposal— �[R—No. 1 Width 9._A ' Total Length 13,5 ' Total leaching area �. Seepage Pit No Diameter Depth below inlet Total leaching area sq. ft. Other Distribution box ( ) Dosing tank ( ) Percolation Test Results Performed by DST Ewalt-ley_ S..S.Q.Q., Date 4.-2.4-.6.0 Test Pit No. 1_2•00 ..minutes per inch Depth of Test Pit 1.6 ' Depth to ground water None Test Pit No. 2 minutes per inch Depth of Test Pit 6 ' Depth to ground water .None Description of Soil 36" M-C sand 7•F-M-C sand Nature of Repairs or Alterations—Answer when applicable Agreement: The undersigned agrees to install the aforedescribed Individual Sewage Disposal System in accordance with the provisions of T ITLL, 5 of the State Sanitary Code—The unders�i/•ned further agrees not to place the system in operation until a Certificate of Compliance has p-4isj�ed b the b`I of h Ith. VAZIC Application Approved By 6 . d Application Disapproved for the following reasons Permit No 4— o Issued THE COMMONWEALTH OF MASSACHUSETTS BOARD OF HEALTH OF ..0-.t. tt tdrrtifiratr of Qtumptittnrr THIS ISdO CERTIFY, That the ndividual Sewage Disposal System constructed ((j4 or 7R/epaired ( ) by ti....� .eInstaller i A..-t.�The-State' lC. .a t-tre lee: at has been installed in accordance with the provisions of TITLE j of Sanitary Code/as descjibed in the application for Disposal Works Construction Permit No g"ir}- dated F./'.i/-P.2+- THE ISSUANCE OF THIS CERTIFICATE SHALL NOT BE CONSTRUED AS A GUARANTEE THAT THE DATE SYSTEM WILL FUNCTION SATISFACTORY. ^ / r/4 re- Inspector 7. f+'c- Noy THE COMMONWEALTH OF MASSACHUSETTS n BOARD OF HEALTH____ t-' ' of '_�-, c-..," C.,. 311inpnu 1 KFnrlin htnnntrnrtian prr it Permission tj�ereby granted / to Construct r ) or Repair L ) an Individual ewage DispoS 1 System at No `j", ; J t 5" n✓ FEE Street r . as shown on the application for Disposal Works Construction Per d '/ r DATE FORM 1255 HOBBS & WARREN. INC.. PUBLISHERS ' ` Board of Health T/9-2 A'eseRVF _-i ARe/4 is i - 29 -- 34? of PROPOSEDi NOUJt < 3,Y H 6.0't Y /00 LEACN P/T CACea14T/ONs 2 etOROOH NOOSE®//Ogpd' 22DSpd GR/NOER /NC vjj 2 j3,77e00n (XS N/r/e : 3 y P d 339a 0 bpd p65/6.✓ FLOW (,60 'Pat PERCO LAT/ON RATE z 2OM4inz %CLOWABLE S/OfWALL= 2.5p44/. ' BOTIOH /.a1m/g., USE KELLOoc /000 L101. ORY Keit DRY WELL = 4.4 y6. v4.7d ADO 2. J STONE ALL FIROUND P/T 9. 4' z /3.5' r 4. 7 d S/0EW9LL BAPAC/Tr : 0442.5)x4.7r 2S;rn/r.F = 530gpd 307TOH CAPA /TY- 9.4X/3.51Y/fA0. _ /27jpd SYSTEM Clb°, e/n' 5.3end * /27nd., 445e f»' PLAN OF PROPOSED SEWAGE DISPOSAL SYSTEM FLORENCE ROAD, NORTHAMPTON PREPARED FOR- /HESS BU/LO/N6 CORP. 1 , LMER HJN'. '_EY,JR. d ASSOCIATES, INC. RE3 STEREr LAN ) SJRVEYORS 8 C /iL ENGINEERS 125 PLEASANT STREET NORTHAMPTON , MASS. JJT SCALE: / 40 I,_ 4-4/-8z n. TE ALL WORM TO BE DONE IN ACCORD- ANCE WITH THE ENVIRONMENTAL C( ri fIF 5 e /3. S w 99 4.4, 2:5 DN Y WELL a- 24 8.� / � Al — (ND 5 .v(E) - !io M/N C. 4470 /2 F1/N/1d0M Mi ET 4,7# PROF/I F (No SCALE) -- 2.5 -L/?c'1YjN 'U—PE7A1L — 7 - li V✓R.:NFD STONE f. S [)(VPALL M IN MUM e _ L .7/.4a/1;f-417 79N E -X-^:+VF n r/ NE/LE .-.',EL n O T EA !_ 14Cf Ht;NTLLY , JR. a A3SOCIATES, INC. AU WORK TO RE tiE SIS NvED ASD EEYORS S COL: NE£R ' DC FCC ..H'1 125 PLEASANT STREET ANC W THE NORTHAMPTON , MASS. C�:;L- tiTLE 5 T kl-cMJES'II'D t',r : LOCI,TI ON: MA I LING DATE: 1 t'