31D-102 (16) BP-2016-0879 29 ELM ST-STODDARD HALL COMMONWEALTH OF MASSACHUSETTS GIs#: CITY OF NORTHAMPTON Ma_p Block: 3 1 D- 102 -001 PExsorrs CONTRACTING WITH UNREGISTERED CONTRACTORS THE GUARANTY FUND (MGL 142A) Lot— Permit� Building DO NOT HAVE ACCESS T BUILDING PERMIT. 1IT t Category:renovation Permit# BP-2015-0877 Project# JS-2015-001714 Est. Cost: $575000.00 Fee: $3450.00 PERMISSION IS HEREBY GRANTED T Contractor: License: const. F W MADIGAN CO INC 057407 Use Group: fr�� 457 38.00 Owner: SMITH COLLEGE OFFICE OF TREASiJRE .c• PlcrrZonin 7 EU(100)/URC(100)/ AppT:29nt:ELM STIP- SDTIOINCI DDARDHALL Phone: Insurance: AnnlicantAddress: 508 753-1459 Workers Com ensation P O BOX 20670 5 0:00:00 WORCESTERMA01602-0670 ISSUED WORK.IRENOVATIONS TO ENTRY RAMP, INTERIOR TO PERFORM THE FOLLOWING RENO TO AUDITORIUM,OFFICE,STORAGE,RESTROOM SPACE ON GROUND FLR POST THIS CARD SO IT IS VISIBLE FROM D.P.W. THE STREET Building Inspector Inspector of Plumbing Inspector of Wiring Service: 3 /3' �S h Meter: Underground:cS/ 1, ✓L� Footings: /�— # Foundation: Rough:4 �: � House Rough: ` Driveway Final: ^✓� .-L�--t.-il �'�� �.a���S� of Final: 9� f irlal' X11 S �� Rough Frame: � Fireplace/Chimney: Gas: Fire D�ent *" � � 'YI L V �16L� �P1i �/ rp �c � Insulation: Rough: � ��� U Final:� `' Final: Smolte: f�C� 3�i�S THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occu anc Si nature: FeeType: Date Paid: Amount: Tle*411 Building 4/14/2015 0:00:00 $3450.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner �� ��� y� ���-� ��is�,,���'l"3' aim �� � f°�� 1 'CONTRACTOR'S MATERIAL TEST CERTIFICATE FOR ABOVEGROUND PIPING PROCEDURE Upon completion of work,inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners and contractor. It is understood the property owner's authorized representative is a legal signatory and fully representitive of the property owner and that by the property owner's or property owner's authorized representitive's signature,the property owner accepts fwII responsibility for the system as installed and agrees that it is in compliance with the applicable approving authoritiy's requirements and local ordinances. PROPERTY NAME DATE /,s 12-(--,S 'PROPERTY ADDRESS ACCEPTED BY APPROVING AUTHORITY 'S)NAMES Local AHJ ADDRESS PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS X YES NO EQUIPMENT USED IS APPROVED X YES NO IF NO,EXPLAIN DEVIATIONS HAS PROPERTY OWNER OR PROPERTY OWNER'S AUTHORIZED REPRESENTITVE X YES NO BEEN INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT IF NO,EXPLAIN INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN GIVEN TO THE PROPERTY OWNER OR PROPERTY OWNER'S AUTHORIZED REPRESENTITIVE: 1.SYSTEM COMPONENTS INTRUCTIONS X_YES _NO 2.CARE AND MAINTENANCE INSTRUCTIONS: _X_YES NO 3. NFPA 25: X YES NO LOCATION OF SUPPLIES BLDGS. SYSTEM MAKE MODEL YEAR OF ORIFICE SIZE QUANTITY TEMPERATURE RATING in MANUFACTURE degrees ° ? SPRINKLERS ° YE PIPE CONFORMS TO NFPA STANDARD X NO PIPE AND FITTINGS CONFORM TO NFPA STANDARD X YES NO S FITTINGS IF NO,EXPLAIN ALARM DEVISE MAXIMUM TIME TO OPERATE THROUGH TEST PIPE TYPE MAKE MODEL MIN. SEC. ALARM VALVE OR FLOW INDICATOR DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. DRY PIPE TIME WATER TIME TO TRIP WATER AIR PRESSURE TRIP POINTAIR REACHED TEST ALARM OPERATED OPERATING TEST THRU TEST PIPE PRESSURE PRESSURE OUTLET PROPERLY MIN. SEC. PSI. PSI. PSI. MIN. SEC. YES NO Without Q.O.D. With Q.O.D IF NO,EXPLAIN i DELUGE& OPERATION PNEUMATIC ELECTRIC I HYDRAULIC PREACTION PIPING SUPERVISED YES NO I DETECTING MEDIA SUPERVISED YES IND VALVES DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATION YES I NO IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING IF NO,EXPLAIN YES NO DOES EACH CIRCUIT DOES EACH CIRCUIT MAXIMUM TIME TO OPERATE SUPERVISION MAKE MODEL LOSS ALARM OPERATE VALVE RELEASE OPERATE RELEASE YES NO YES NO YES NO HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi(13.6 bars)for two hours or 50 psi(3.4 bars)above static pressure in excess of 150 psi(10.2 bars)for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. TEST FLUSHING: Flow the required rate until water is clear as indicated by no collection of foreign material in burlap bags at outlets such as DESCRIPTION hydrants and blow-offs. Flush at flows not less than 400 GPM for 4-inch pipe,600 GPM for 5-inch pipe,750 GPM for 6-inch pipe,1000 GPM for 8-inch Pipe,1500 GPM for 10-inch pipe, and 2000 GPM for 12-inch pipe.When supply cannot produce stipulated flow rates,obtain maximum available. PNEUMATIC: Establish 40 psi(2.7 bars)air pressure and measure drop which shall not exceed 1-1/2 psi(0.1 bars)in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi 0.1 bars in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HRS. IF NO,STATE REASON DRY PIPING PNEUMATICALLY TESTED YES X NO EQUIPMENT OPERATES PROPERLY X YES NO DRAIN TEST READING OF GAGE LOCATED NEAR WATER SUPPLY TEST PIPE. RESIDUAL PRESSURE WITH VALVE IN TEST TESTS STATIC PRESSURE: PSI I PIPE OPEN WIDE PSI Underground mains and lead in connections to system risers flushed before connection made to sprinkler piping. VERIFIED BY COPY OF THE U FORM NO.85B OYES NO JOTHER EXPLAIN FLUSHED BY INSTALLER OF UNDER GROUND SPRINKLER PIPING X YES NO NUMBER REMOVED TANK TESTING NUMBER USED LOCATIONS AND GASKETS 0 p WELDING PIPING I X IYES1 I NO IF YES........ DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9,LEVEL AR-3 QX YES 0 NO DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED WELDING IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9,LEVEL AR-3 0 YES Q NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED,THAT OPENINGS IN PIPING ARE SMOOTH,THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED,AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED F_X_j YES NO HYDRAULIC DATA NAMEPLATE PROVIDED IF NO,EXPLAIN NAMEPLATE 0 YE No DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: REMARKS i NAME OF SPRINKLER CONTRACTOR Red Hawk Fire & Security TESTS WITNESSED BY SIGNATURES FOR PROPERTY OWNER(SIGNED) TITLE DATE I FOR KLER CONTRACTO (SIGNED) TITLE DATE ADDITIONAL EXPLANATION AND NOTE �1 (�Hydrostatically Tested on: Alarm Tested on: "77 i I I I Juster Pope Frazier LLC Architecture I Planning 82 North Street Northampton,Massachusetts www justerpopefrazier.com 4 1 3 5 8 6 1 6 0 0 Smith College Stoddard Auditorium Renovations Northampton, Massachusetts Mr. Louis Hasbrouck, Northampton Building Commissioner 212 Main Street Northampton, MA 01060 Dear Sir, I am writing in regards to the request for a tempora Auditorium Renovation project. As you know. the temporary Certificate of Occupancy for the Stoddard Hall has been unable at complete the exterior general contractor, FW requested a Temporary porch/entry on the south elevation'Of the building.gan Inc. Of Worcester,y MA. p ry Certificate of Occupancy so that Smith College may utilize the main auditorium for classes. FW Madigan assures me that the porch/entry will be completed no later than September y have The building is fully sprinkled with required fire alarm system throughout. 12:2015. I have reviewed this situation relative to the building code. Building occupants will still have tw routes of egress through the north entry/exit and through use u a preexisting fire escape on the east the building. The auditorium itself which contributes the most occupants to the building two separate immediate remote means of egress from the space through the lower level egress into the rima side of the upper level egress through the fire escape. by far, has two reduced through renovation. The previous occupancy was approximately three hundred, p rY lobby and is one p Note that the occupancy of the auditorium has also been egress hundred for and 1 forty. c upantstwo (36rd sided 2 Occupant ess doors from the auditorium are each 36" wide andeea�h Provide pant per inch). Given this analysis, I do not take exception to the request for a temporary C of O. ncere bak, 70.Tgfifect=-- J er Pope Frazier Architects Final Construction Control Document 4 F To be submitted at completion of construction by a Registered Design Professional for work per the 8th edition of the 4�•v Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Stoddard Hall,Exterior Renovations Date:9/2/2015 Permit No. BP-2015-0876 Property Address: 29 Elm Street, Smith College,Northampton, MA Project: Check(x) one or both as applicable: New construction X Existing Construction Project description: I, Laura Fitch, MA Registration Number: 8835 Expiration date: 8/2016 ,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: I I x Architectural Structural Mechanical Fire Protection Electrical Other: Describe for the above named project. I,or my designee,have performed the necessary professional services and was present at the construction site on a regular and periodic basis.To the best o'f my knowledge, information, and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. Enter in the space to the right a"wet"or electronic signature and seal: gaED APC No WS OF Phone number: 413-549-5799 Email: lfitch@krausfitch.com Building Official Use Only Building Official Name: Permit No.: Date: Version 06 11 2013 29 ELM ST-STODDARD HALL BP-2015-0876 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 3 1 D- 102 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit# BP-2015-0876 Project# JS-2015-001713 Est. Cost: $385785.00 Fee: $3510.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: F W MADIGAN CO INC 057407 Lot Size(sq. ft.): 45738.00 Owner: SMITH COLLEGE OFFICE OF TREASURER Zoning: EU(100)/URC(100) Applicant: F W MADIGAN CO INC AT. 29 ELM ST - STODDARD HALL Applicant Address: Phone: Insurance: P O BOX 20670 (508) 753-1459 WORCESTERMA01602-0670 ISSUED ON:4/9/2015 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL REPLACEMENT WINDOWS & MASONRY REPOINTING POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough; Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVD HE C Y NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND Certificate of Occu an Si nature: FeeType: Date Paid: Amount: Building 4/9/2015 0:00:00 $3510.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner I Final Construction Control Document W To be submitted at completion of construction by a Registered Design Professional for work per the 8'h edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Stoddard Hall,Exterior Renovations Date:9/2/2015 Permit No. BP-2015-0876 Property Address: 29 Elm Street, Smith College,Northampton,MA Project: Check(x)one or both as applicable: New construction X Existing Construction Project description: I, Laura Fitch,MA Registration Number: 8835 Expiration date: 8/2016 ,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: x Architectural Structural Mechanical Fire Protection Electrical Other: Describe for the above named project. I, or my designee,have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge,information,and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. Enter in the space to the right a"wet"or electronic signature and seal: {x'Crs�ERE E.�FC��j' * yk No.8835 �AM HERST ASS. Phone number:413-549-5799 Email: lfitch@.krausfitch.com Building Official Use Only Building Official Name: Permit No.: Date: Version 06 11 2013