Loading...
36-267 (8) 235 MAPLE RIDGE RD BP-2016-1064 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 36-267 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-1064 Project# JS-2016-001810 Est. Cost: $25000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: VALLEY HOME IMPROVEMENT INC 060300 Lot Size(sq. ft.): 108900.00 Owner: GILSON STEPHEN M&LYNNE M SANER Zoning: Applicant. VALLEY HOME IMPROVEMENT INC AT. 235 MAPLE RIDGE RD Applicant Address: Phone: Insurance: P O BOX 60627 (413) 584-7522 Workers Compensation FLORENCEMA01062 ISSUED ON:3/7/2016 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL ROOF MOUNTED 28 PANEL SOLAR ARRAY - sister each rafter w/ 2 - 2 x6 POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 3/7/2016 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File# BP-2016-1064 APPLICANT/CONTACT PERSON VALLEY HOME IMPROVEMENT INC ADDRESS/PHONE P O BOX 60627 FLORENCE01062(413)584-7522 PROPERTY LOCATION 235 MAPLE RIDGE RD MAP 36 PARCEL 267 001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENOL SED REQUIRED DATE ZONING FORM FILLED OUT 11-A I Fee Paid 42, 10 BuildinIZ Permit Filled out It Fee Paid Typeof Construction: INSTALL ROOF MOUNTED 28 PANEL SOLAR ARRAY New Construction9=nh 6J et, Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 060300 3 sets of Plans/Plot Plan R NG ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON MATION PRESENTED: proved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management n la u f Buildin Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. Department use eniy i City of Northampton Status of Permit: I - Building Department Curb Cut/Driveway Permit i 212 Main Street Sewer/Septic Availability W - 32016 Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans DEPT.of BUILDING INSPECTIONS ph ne 413-587-1240 Fax 413-587-1272 Plot/Site Plans NOM-HAMPTON MA 01060 Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office �.� Map Lot Unit Zone Overlay District 1 Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: L�(W& o f;., .* & In h eo H11 iou �� ' 110,lf:t'Le of >-I" . Name(Print) Current Mailinb Address: r• Telephone Signature 2.2 Authorize Agent: Ne\soc Sh• `ch-� 11 en -� Q-o.6c l�oc�a1 qkoren.cr-�-tom ok 0bZ Name(Print Current Mailing Address: Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Ite.TI Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building �U (a)Building Permit Fee o 2. Electrical (b)Estimated Total Cost of .5 v'd-D Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=0 +2+3.+4+5) - Check Number This Section For Official Use Only Buiiding Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date r �p�� �14�✓Jf cS`��/I� SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors (] Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [M Siding[o] Other[AL Brief Description of Proposed F Work: �iv3T�II caAei / dr, Ad 4 A' 129'1 r.) /?va� Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a.If New house and or addition to existing housing, complete the following: a. Use of building :One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces r /ods)eP_Number of each g. Energy Conservation Compliance. Massche k Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1, ` ✓`� <l ,as Owner of the subject property hereby authorize N_�n b` ,4 het} �Q�,rLu, brn�c�ye1��0�i2fy�@y c�rL C- to act on m behalf, in all matters relative to work autho ' ed by this building permit application. Signatureo wner Date I, Ol-�`G�-1 tCIL (��C�3LrylA�rr� ,' �lL as Owner/Authorized Agent hereby declare that the statements and nformation on the foregoing application are true and accurate,to the best of my knowledge ana be'iief. Signed under the pains and penalties of perjury. X1_! �. Print Name f Signature of Ovmer/Agent Date w Section 4. ZONING All Information Must Be Completed.Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: _ L:' R: Rear Building Height Bldg.Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DONT KNOW Q YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES 0 IF YES: enter Book Page ar�d/or Document# B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued: C. Do any signs exist on the property? YES Q NO 0 IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO 0 IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading, excavation, or filling)over I acre or is it part of a common pian that will disturb over 1 acre? YES 0 NO 0 IF YES,then a Northampton Storm v,iater Management Permit from the DPW is required. SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: �� �1\\�-"C,CT T 0(D b2 00 v0,kk Qom, 1 ko( J.�M r�rpJQ�(Y�Cr 1-�� L License Number ?.c> JQxx 912z 116 Address Expiration Date Signature Telephone 9.Re istered Home Improvement Contractor: Not Applicable ❑ Company Nufne Registration Number Qb .J)CY, , 7-kc)rencr- VAa CAO(62- -111-11 )�, Address1l,, Expiration Date Telephone,A&f�94:�2z SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)} Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... X No...... ❑ 11. Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.AAperson who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building hermit. As acting Construction Supervisor your presence on the iob site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature 3-2-2016 Charles Miller Re Saner Gilson Solar System 235 Maple Ridge Rd. Florence, Ma Hello Chuck Attached are photos of the Saner Roof where we're installing a 28 panel solar array after stripping and reroofing the area. We have a permit of the roofing work and we started that work earlier this week. This is a cathedral ceiling roof system that runs from the ridge to the outside wall,with no way of determining the rafter dimension. However,there is an adjacent cathedral area where we were able to determine that there were 2 x 12 rafters 16"o.c.,so we naturally assumed this area, which has a much wider span,would be 2 x 12's as well. However,when we removed the shingles,we double checked and saw that the roof has 2 x 10's which are way undersized even for the code when the house was built. The rafters are 22' long with a run in excess of 17' We reached out to Dave Vreeland right away and he came up with the solution shown on the attached plans,which we implemented right away as the roof was stripped. Attached are photos showing the work we did yesterday. You'll see that we removed and reinstalled one layer of insulation in order to install the 2 x 6's There is still about 40%of the area that has not been roofed if you want to take a look. If you'd like to stop by the guys will be working there in the morning,weather permitting. I've asked Aron to call you in the morning. Thanks Nelson -21 ,6 w 3-2-2016 Charles Miller Re Saner Gilson Solar System 235 Maple Ridge Rd. Florence, Ma Hello Chuck Attached are photos of the Saner Roof where we're installing a 28 panel solar array after stripping and reroofing the area. We have a permit of the roofing work and we started that work earlier this week. This is a cathedral ceiling roof system that runs from the ridge to the outside wall,with no way of determining the rafter dimension. However,there is an adjacent cathedral area where we were able to determine that there were 2 x 12 rafters 16"o.c.,so we naturally assumed this area,which has a much wider span,would be 2 x 12's as well. However,when we removed the shingles,we double checked and saw that the roof has 2 x 10's which are way undersized even for the code when the house was built. The rafters are 22' long with a run in excess of 17' We reached out to Dave Vreeland right away and he came up with the solution shown on the attached plans,which we implemented right away as the roof was stripped. Attached are photos showing the work we did yesterday. You'll see that we removed and reinstalled one layer of insulation in order to install the 2 x 6's There is still about 40%of the area that has not been roofed if you want to take a look. If you'd like to stop by the guys will be working there in the morning,weather permitting. I've asked Aron to call you in t e mo c Thanks Nelson �- l i yx ..e Fay p, Sv �Xx i; 5 r� ^h.U,F„y7r �x a g e < 6 t y, ff Ar { � u kris, �t Y- f f City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: a3 y i& I c Z `,,&, // 9 - The debris will be transported by: /,0 V14 S The debris will be received by: C119 l/� 12rr Building permit number: Mame of Permit Applicant /f7l Date Signature of Permit Applicant SITE PLAN N ' x 13 < ; National Grid Customer: Lynne M Saner, 235 Maple Ridge Rd., Florence Ma, 01062 Acct #: 51459-54020 Panels & power optimizers, combiner box on roof PV Modules: 310w LG 2. External wail of house Power optimizers: 28 SolarEdge P320s SolarEdge inverter with built-in AC/DC disconnect switch, Inverter: SolarEdge 7.6kW central inverter , f Revenue grade meter, Utility meter �J 3. Internal wall of basement: TOTAL: 28 PV modules Main lectrical panel system TOTAL: 6.867 kW DC s 340 Riverside Drive, Northampton, MA 01062 www valleysolar.solar 413.584.8844 �. tt5SS5 kk { d w r . y � .x •• > v4` Yom. � � •" 1 2n e r,�. qy F x r MEE=. �'•, 1 r v 5e �� V Saner, 235 Maple Ridge Rd: Parcel #36, 2.5 acres LC V 340 Riverside Drive, Northampton, MA 01062 www valleyxsolar.solar 413.584.8844 L _------- ---- ---I Qtl l f M INi ti(H I DU Li —_ -- —. ---- ----� IAG DESCRIPTION PART NUMBER NOTES SOLAR PV MODULE CIS 3 i o -X CSW. PV ARRAY /I"(i+j ltl E ? S I x1114` 3 J-BOX(IF IJSFD) J CO,VBINER(IF USED) 9 DC DISCONNECTJ�T U1lLrrY ® DC;AC INVFRrFR $ Loc A-US t.N:t>� « GEN METER(IF USED) 9;—:7 /.2 to 5r lii�l(_L a x AC DISCONNL C I (IF USED) Al « SFRV)CF PANE f- 'IYs VAC. 200 A MAIN, .¢ _A 13US, _ _ A 1NVT RTFF2 OCF'D (SFF NOTF 5 FOR INVFRTFR OCPDs.ALSO SCF GIADF SECTION 9) 1 n34 5 6 7 ) 8 9 MIJ1101 t 4 9 / f MAINL j w e INVfRiFR OG'f r-777771COMBINER f ! MODULES IN aDC DISCO a AC I)I (C) SERIES SOURCE C,1R'CUIT. c , I •w .wl.aw w wawa w,, ;wwwwwwww�r INW Rif 4 4 9 N/,�� Mc)i�)I)I FS IN �I Ot�iD I 9 SFRIf'SSOURCF-CIRCUITa � _�, w o BUILDING sLfi1Ls souRCL c,Il.cul r« —w Disregard if GROUNDINGFOR UNUSED SERIFS STRINGS Z2 3 provided With ELECTRODE Pini "NIA iri BLANK ABOVE Il'1VE'rter SEE GUIDE APPENDIX C FOR INFORMA riON ON MODUI F AND APPAY(;ktH WI)IN(i N IA(, DESCRIPTION OR CONDUCTOR TYPF (.OND. NUMBFR OF CONII011 CONDUIT GAUGE CONDUCTORS iY)'I .>Izc L( ,I One-Line Standard Electrical Diagram for Address dud Pho,e 1 USF-2 O of PV wIRL❑ N/A N/A Valley Solar Small-Scale, Single-Phase PV Systems � BARI COPPI R F0.GRD-COND.(r GC) N/A N/A 340 Riverside Drive --- — —�_. -- _ THWN?L❑ or XHHW-?L7 or RH>>v-?G Site Nary e:__ ftQfC^ Northampton N1A 01082 3 THVVN Z r-! or XHF1W?!-i or I2HW 2 Fl It e e� cQO- sep,i q— -- Site Adt1YeSS:_�:2 36 INSULA IED LGC SyStern AC; `size: '90DO A DC GROUNDING FI FCTRODI-GOND. :ung Nu ( nw,,No v a S t rIvVN,1 U or Xrit-10 t o or iv- v G Ll F---....... INSULA I l.D L(;(: h",>.,,;Ry j(- ui_t: .ti --_NiS —i..I).atr: I `-------- Single Phase Invertersfor forth America S o a a (, F sri.�4, S S'E300OA-US SE3900A-US SESOOCA-US SE05001;-US SE760DA-US SE10000A-US SE1140OA-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9930 @ 208V i 11400 VA 1 WDO @240V f0ax.AC Power Uut u 3300 4154 6000 8350 1.2000 VA p ' S455450 @)240V5400 @ 208V 24dV 10950(�2,1(iV 10800 @ 208V i AC Output Voltage Min.Nom:Max!:! 183-208-229 Vac AC Output Vnitage Min-Nom IV ax.i l f V 1 d 211-240-264 Vac AC Frequency[Ain.-worn:Max ai 59.3-60-60.5 Hz rna ie%iax.Continuous Output ut Current 12.5 16 LS 32 47,5 A � 24 70FV 4,13 @ 208V 21 240V 42 @ 240V GFDl Threshold1. A Utility Monitoring,Islanding Protectinia,Country Confi,.uraible Threst'toPcls Yes yes IWIPUT Maximum DC Power(STC) 4050 5100 6750 8100 10250 11500 :5350 W Transformer-less,Ungrounded yes MIX,tnput Voltage _ .500 Vdc Norm.DC Input Voltage 325 @ 208V 7>50 @ 240V Vdc 16.5 @ 208V 33,@ 208V Max.Input CUrrerit(2' 9.5 13 18 23 34.5 Adc. 15.5 @ 240V 30.E L 240 Max..Input Short Circuit Current 45 Adc Reverse-Polarity Protection yes Ground-Fauit Isolation detection 600kcz Sensitivity Maximurn Inverter Efficiency 97.7 98.2 98.3 993 98 98 98 % 97 @ 208V 97 @ 208V CEC Weighted Efficiency 97,5 98 97.5 97.5 97,5 % 98 @ 240V 975 @ 240V Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES -u;,)ported Conimunicction Interfaces RS48S,RS232,ethernet,Zigaee(upthcmal) F;evenue Grade Data,ANSI 0-12.1 Optional(') Rapid Shutdovvn—NEC 2014 694.12 les STPs[IDARD(,OF'if W,PL/IE CF af-ty L,'Ll741,UL_.19913,lyf•i 998,CSP )2.:! IEI ernisslnns FCC par.ls class 8 WSTALLATIC3Nt SPECIFICATIONS AC output conduit size f AWG range :414"minimum j'16-6 AWG 3J4"minimum j 8-3 AWG DC input conduit Size/h of strings( 3/4"minin'lum(1-3 strings t 3,W'miriin'au;i771-2 'trirrgsjlU6At'4G AWG i"ange 14-6 AWG ?'uncrislot s with'.afr^.`j Switch ancn. 3C.5,.12.5 x 10.5 i in ,+>c , j c rtc (H. VX11) 5 x 315 260 rnnl vver_knt with Jaiety''Swilci, Sj_, !2n.2 !4./ Hk.4/40 1. Natural convectlnn Cooling Natural Convection and internal Fans(user replaceable) fan(user replaceable) P`tcl.>e <25 <50 d5A Min.-!Oax.uperatillg'er;',r} rrtur,- -13 to+140/-25 to+60(-40 to+60 version available(") 'F "C Protection Rating NEMA 3R iAl For other regional settings please contact So{nrEdge support, ist f higher current source may be used;the inverter will limit its Input current to the values stated. ?sr Revenue g;<de lnvertcr Pih:s.-=x s_;-USOOONNR2(for 7e0OW inverter:SE760DA•USF.02NNt{2). d _ r z ,: (6 LG in hovatilon for [,ifs\Good • Better • s - LG :Nits 0 C Enhanced Performance Warranty High Power Output i I CC Aesthetic Roof Outstanding Durability ®� Better Performance on a Sunny Day Double-Sided Cel(Structure J u.rci LG '['\!eON ; WHOM Mechanical Properties Electrical Properties(STC*} Cells _ I n ;Ao',hile rYl"e 310 011 Celt Vendor - MPP}lrft rhe(Vfnpp) J,F','Cur re 1 t(fmppl Ceti T}yrC: ,c =i.., i`; ,E _ e ll ?_o:,,sr,;irns ,; , es pen far uit Voltage(foo) ,.of Busbar : _ n �..� Snort Cera!;: Current iI c) Dme.want(€ x V H'I Modlu€e Efficiency(% Front -"k ._ -° 10,1X,mLn Syst:ewr voltage(V) _ 1, ,tv�2r L^�oez � ,:�,, _. -.P��x�.r,..ir...r��re4 P>_4er€YrzPin: trYfeig , .. 1,k.. Power Toie;grace(f,) Connector .,fps, L A c,,V 3u..+:ton Box Gtas5 I r r o Electrical Properties(NOCT*) Module,dule r.rt e 310 VV Certifications and Warranty 1, Power(Pro u) Jlp hal e Vrlyp z KA PP 'Open Cir,,uil Vo'rape(Voc) - for l •ru11.Current(tsr) -... f4xru.i+;4 r erfolM nr )�,Ai ,-ire Ratwn,fry ,,sr a; Dimensions(mm/in) F odr,e«frVarcrant. '" r -�. Temperature Characteristics 1 Ncc.; r ISC , i Characteristic Curves a � 4 I X r r 1 6) (i s _ L _- V! ■ innuaatGortIto,aBettxrLife [Ail .i IRONRIDGE XR Rail Family Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing , enough to buckle a panel frame. XR Rails are the structural backbone preventing71 r these results. They resist uplift, protect against buckling and safely and efficiently ' transfer loads into the building structure. v Their superior spanning capability cs ,Fc z T requires fewer roof attachments, , ,� reducing the number of roof penetrations and the amount of installation time. Force-Stabilizing Curve Sloped roofs generate both vertical and lateral ! ' forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of marine-grade m, compatible with I , a range of tilt leg aluminum alloy,then protected with an FlashFoot and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing attachments. applications. a more attractive appearance. i XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. '�w„w,.w,�_.y •.w"""""".�""""`°�ww.,ry„r�__.—.'~`- �'••www"+++r"""rw,wr�„ep�_.__.,,...... XR10 XR100 XR10W XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow. It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or remaining light and economical, maximizing spans up to 8 feet. more for commercial applications. • 6'spanning capability 8'spanning capability 12'spanning capability • Moderate load capability Heavy load capability Extreme load capability • Clear anodized finish Clear&black anodized finish Clear anodized finish • Internal splices available Internal splices available Internal splices available Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. i 100 120 None 140 XR10 XR100 XR1000 160 100 120 10-20 140 160 100 30 160 100 40 160 50-70 160 80-90 160 H Project:Gilson 2x12 p pees Ste hen Gross Location:RFT3 Valle H p Roof Rafter 511iIC y Home Improvement " .��"' 340 Riverside Drive or [2009 International Residential Code(2012 NDS)] :: Northampton,ma 01062 1.5 IN x 9.25 IN x 18.5 FT(17.5+ 1)@ 16 O.C. #2-Spruce-Pine-Fir-Dry Use StruCalc Version 9.0.2.5 2/26/2016 2:29:13 PM Section Inadequate By:25.4% Controlling Factor:Moment/Depth Required 10.36 In. DEFLECTIONS Center Right LOADING DIAGRAM Live Load 1.07 IN U212 0.00 IN 21J9730 Dead Load 0.26 in 0.00 in Total Load 1.33 IN 0171 0.00 IN 21Jlnfinity Live Load Deflection Criteria:U240 Total Load Deflection Criteria: U180 RAFTER REACTIONS LOADS REACTIONS Upper Live Load @ A 394 plf 525 Ib Upper Dead Load @ A 95 plf 126 Ib Upper Total Load @ A 488 plf 651 Ib Lower Live Load @ B 440 plf 587 Ib Lower Dead Load @ B 106 pff 141 Ib Lower Total Load @ B 546 plf 728 Ib 17.5 ft RAFTER SUPPORT DATA A B A_ B Bearing Length 1.02 in 1.14 in RAFTER LOADING RAFTER DATA Interior Eave Uniform Roof Loading Span Length 17.5 ft 1 ft Roof Live Load: LL= 45 psf Rafter Pitch 5 :12 Roof Dead Load: DL= 10 psf Roof sheathing applied to top of joists-top of rafters fully braced. Slope Adjusted Spans And Loads Sheath i ng/sheetrock applied to bottom of joists-bottom of rafters fully braced. Interior Span: L-adj= 18.96 ft Roof Duration Factor 1.15 Eave Span: L-Eave-adj= 1.08 ft Peak Notch Depth 0.00 Rafter Live Load: wL-adj= 51 plf Base Notch Depth 0.00 Eave Live Load: wL-Eave-adj= 51 plf MATERIAL PROPERTIES Rafter Dead Load: wD-adj= 12 plf #2-Spruce-Pine-Fir Rafter Total Load: wT-adj= 63 pff Base Values Adjusted Eave Total Load: wT-Eave-adj= 63 plf Bending Stress: Fb= 875 psi Fb'= 1273 psi Cd=1.15 CF=1. Cr-1,15 Shear Stress: Fv= 135 psi Fv'= 155 psi Cd=1.15 Modulus of Elasticity: E= 1400 ksi E'= 1400 ksi Comp. L to Grain: Fc- L= 425 psi Fc--L'= 425 psi Controlling Moment: 2846 ft-Ib 8.751 Ft from left support of span 2(Center Span) Created by combining all dead loads and live loads on span(s)2 Controlling Shear: -603 Ib 3 17.538 Ft from left support of span 2(Center Span) i Created by combining all dead loads and live loads on span(s)2,3 ; Comparisons with required sections: Reo'd Provided Section Modulus: 26.83 in3 21.39 in3 Area(Shear): 5.83 in2 13.88 in24 Ov Moment of Inertia(deflection): 111.95 in4 98.93 i Moment: 2846 ft-Ib 2269 Shear: -603 lb 1436 Ib NOTES i ! N