Loading...
42-147 (4) SolarCity MAR 18 2016 DErrr.Cr s .:_r;l a0 INs7'=c-90Ns NOR HA,MP MN,MA 01060 March 17, 2016 NORTHAMPTON BUILDING/ELECTRICAL DEPT Enclosed is a re-design update for: Andrew Woodland 907 Westhampton Rd Florence, MA 01062 Per engineering and design, inverter swap to IN-101214-038 due to RGM requirement enforced by State of Massachusetts. Changes: • Inverter swap to IN-101214-038 due to RGM requirement enforced by State os Massachusetts. No other changes. System Size: 4.16 kW Please add the new drawings to the permit numbers issued for this address: Building Permit: BP-2016-0950 Electrical Permit: EP-2016-0571 If anything else is needed, please contact me directly. Sincerely, Vict 'ria Junck Permit Coordinator SolarCity ----------------------------------------------------------------------- t: 978.215.2367 m: 413.454.9753 604 Silver Street,Unit#3,Agawam,MA 01001 T (888)SOL-CITY solarcity.com AL 05500,AR M-8937.AZ ROC 243771/ROC 245450,CA CSLB 888104,CO EC8041,CT HIC 0632778/ELC 0125305,DC 410514000080/ECC902585,DE 2011120186/TI-603Z FL EC13006226,HI CT-29770.IL 15-0052.MA HIC 168572/ EL-1136MR,MD MIC 128948/11806,NC 30801-U.NH 0347C/12523M,NJ NJHIC#13VH06160600/34EB01732700.NM E�98-379590.NV NV20121135172/C2-0078646/82-0079719.OH EL 47707,OR C8180498/C562.PA HICPA077343,RI AC004714/Reg 38313,TXTECL27006,UT 8726950-5501.VA ELE2705153278,VT EM-05829,WA SOLARC•91901/SOLARC905P7.Albany 439,Greene A-486.Nassau H2409710000.Putnam PC6041,Rockland H-11864-40-00-00.Suffolk 52057-H.Westchester WC-26088-H13.N.Y.0#2001364-DCA SCENYQ N.Y.C.Licensed Electrician.#12610.#004485.185 Water St,6th Fl.,Unit 10.Brooklyn,NY 11201.#2013966-DCA AJI loans prodded b7 SolarCi ty Finance Company.LLC. CA Finance Lenders License 6054796.SolarCity Finance Company.LLC is licensed by the Delaware State Bank Commissioner to engage in business In Delaware under license number 019422.MD Consumer Loan License 2241,NV Installment Loan License IL11023/IL11024.Rhode Island Licensed Lender#20153103LL.TX Re®stered Creditor 14100050963-202404,Vr Lender License#6766 f'F ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A .4 ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(8). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT WNEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK SHALL COMPLY WITH THE 2009 IBC ELEC 1136 MR AND 2009 IRC. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2008 NATIONAL ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR ' AHJ: Northampton REV BY DATE COMMENTS REV A GT 3/16/2016 Inverter Swap UTILITY: National Grid USA (Massachusetts Electric) CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-01 01849 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE ANDREW WOODLAND Andrew Woodland RESIDENCE David Alcocer em' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:WH ��� SolarCity NOR SHALL IT BE DISCLOSED IN OLE OR IN Comp Mount Type C 907 WESTHAMPTON ROAD 4.16 KW PV ARRAY �A PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON, MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-260PD05.18 24 St. Martin Drive, Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE T. (650)638—a1r 28 F:A(65O) 638-1029 01752 PERMISSION OF SOLARCITY INC. SOLAREDGE SE3800A—USOOOSNR2 COVER SHEET PV 1 a 3/16/2016 (888)-SOL-CITY(ass-za6s) www.sdaraitycam PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH:343 ARRAY AZIMUTH:343 A MATERIAL: Comp Shingle STORY: 1 Story TdW N � Inv (E) MOD LEGEND L (E) EQ (E) MODS (E) UTILITY METER & WARNING LABEL AC ' Inv Inv �� (E) MODS Inv 8 INVERTER W/ INTEGRATED DC DISCO L___J 1 & WARNING LABELS M D ; ; © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS rn rD Front Of House a DISTRIBUTION PANEL & LABELS LG LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE (E) DRIVEWAY HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L-'J 907 Westhampton Rd Lot 4, **COGEN** SITE PLAN " Scale: 1/8" = 1' W 0 1' 8' 16' E LPL S PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J g-0101849 00 David Alcocer \`!r�OI���'�` CONTAINED SHALL NOT BE USED FOR THE ANDREW WOODLAND Andrew Woodland RESIDENCE Y® BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 0A., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 907 WESTHAMPTON ROAD 4.16 KW PV ARRAY p T TO OTHERS OUTSIDE THE RECIPIENTS MODULES- NORTHAMPTON, MA 01062 ORGANIZATIQN, EXCEPT IN CONNECTION WITH 24 St. Martin Drive,Building 2, Unit 11 THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-260PD05.18 PAGE NAME SHEET: REV: DATE Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT HE WRITTEN INVERTER: T. (650)636-1026 F. (65 0)638-1029 T PERMISSION OF SOLARCITY INC. SOLAREDGE SE3800A—USOOOSNR2 SITE PLAN PV 2 a 3/16/2016 (888)—SOL—CITY(765-2469) ww.sdarcity.com PV MODULE Ut 3'-4"t 5/16„ BOLT WITH LOCK INSTALLATION ORDER ` 2x8 SPF�2 (N & FENDER WASHERS S1 ' LOCATE RAFTER, MARK HOLE MIN6_8•f ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT \\`) ZEP ARRAY SKIRT (6) HOLE. (4) Q2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. 15'-6" ZEP COMP MOUNT C 1'— (E) LBW ZEP FLASHING C (3) (3) INSERT FLASHING. SIDE VIEW OF MP1 NTS SISTER UPGRADE INFORMATION: RAFTER UPGRADE INDICATED BY HATCHING (E) COMP. SHINGLE (4) PLACE MOUNT. UPGRADE NOTES: MPJ I X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVERNOTES 1. CUT AND ADD (N) SISTER AS SHOWN IN THIS SIDE VIEW AND REFERENCED TOP VIEW. (E) ROOF DECKING (2) LANDSCAPE 64" 24" STAGGERED 2. FASTEN (N) SISTER TO (E) MEMBER W/ SIMPSON SOW 22300 (IF 2—PLY) OR 22458 (5) INSTALL LAG BOLT WITH PORTRAIT 48" 18" (IF 3—PLY) SOW SCREWS AS SHOWN AT 16" O.C. ALONG SPAN AS SPECIFIED, IF 5/16 DIA STAINLESS (5) SEALING WASHER. ROOF AZ I 343 PITCH 23 �' DRILL BIT. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES RAFTER 2x8 @ 16"OC sroRlEs: 1 WOOD SPLITTING IS SEEN OR HEARD, PRE—DRILL WITH A ARRAY AZII 343 PITCH 23 ALT. OPTION FOR FULL LENGTH MEMBERS ONLY— FASTEN N SIDE MEMBER TO INSTALL LEVELING FOOT WITH C.I. 2x6 @16"OC Comp Shingle ( ) WITH SEALING WASHER (6) (E) RAFTER W/ 10d (IF 2—PLY) OR 16d FROM EACH SIDE (IF 3—PLY) COMMON (2-1/2" EMBED, MIN) BOLT & WASHERS. NAILS AT 6" O.C. ALONG SPAN. •SISTER ALL RAFTERS ON THIS MP SECTION INTO WHICH THE ARRAY IS LAGGED (E) RAFTER S 1 STAN DOFF NOTE: LAP SPLICE DOES NOT NEED TO BE CENTERED ON THE MEMBER (E) WALL OR 6" END SUPPORT BELOW (E) RIDGE BOARD DISTANCE MI - OR SUPPORT BELOW 6"_��STAGG.16" O.C.TYP.�, (E) 2x8 RAFTER * SIMPSON SDW SIMPSON SDW 22458 - 3„ 22300 WOOD WOOD SCREWS * Q ...... p SCREWS (N) SISTER MEMBERS 1 2 - 4 b (E) RAFTER SIMPSON SDW WOOD SCREWS (N) 2x8 SISTER MEMBER '-0" MIN. AA SEE MP SIDE VIEW FOR REQUIRED LENGTH A1� Di 2x8 END FASTENER GROUPING - MIR Scale: 1"=1'-0" U 1 TOP VIEW OF PARTIAL LENGTH LAPPED SISTER Scale: 3/4"=1'-0" CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 01849 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHAD NOT BE USED FOR THE ANDREW WOODLAND Andrew Woodland RESIDENCE David Alcocer ����• • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ` SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 907 WESTHAMPTON ROAD 4.16 KW PV ARRAY �i�� PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON M A 0106 2 ORGANIZATION, EXCEPT IN CONNECTION WITH , THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-260PDO5.18 24 St. Martin Drive, Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE NRIT1174 INVERTER: PAGE NAME SHEET: REV.. DATE: Marlborough, MA 01752 PERMISSION OF SOLARCITY INC. P V 3 a 3/16/20161 ' (650) 636-1028 F:;650)638-1029 SOLAREDGE SE380OA—USOOOSNR2 STRUCTURAL VIEWS ( )-SCI-CITY(765-2489www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:LC230PC Inv 1: DC Ungrounded INV 1 -( SOLAREDGE SE3800A-USODOSNR2 LABEL: A (16)TRINA SOLAR ## TSM-260PDO5.18 GEN #168572 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:60939607 Tie-In: Supply Side Connection Inverter; 38 OW, 240V, 97.574 w/Unifed Disco and ZB,RGM,AFCI PV Module; 260W, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Overhead Service Entrance INV 2 oc: 38.2 Vpmax: 30.6 INV 3 sc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 WIRING CUTLER-HAMMER BRYANT (E) Disconnect CUTLER-HAMMER (N) 125A Load Center q Disconnect 3 SOLAREDGE SE3800A-USOOOSNR2 LL B 20A C D 20A/2P F27L2 SolarCity A /7\ L1 20OA/2P B �1\ LN Z a 1 - (E) LOADS GND ____ GND _- _ EGCI DC+ DC+ FT L - Q I--------------- GEC ---TN DC- DC-------MP 1: 1x16 r • � z � GND --- ---- - EGC ---------_� -- EGC--------------------------- '- 1 t I I I 1 Inv r 2 N I I I I SOLAREDGE o I I SE3000A-US-ZB-U Z -D i i 20A/21' GEC I I L7 F2 1] N El TO 120/240V I ' __ _____________ EGCI ___ DC+ DC+ SINGLE PHASE I }� UTILITY SERVICE , _ MP 2&3:-1x1 GEC N DC- DEGC I GND _ ,- -------- -----� EGC-------------- -------- - ---- I I I I ' ' Inverter 3 SOLAREDGE SE3000A-US-ZB-U 20A/2P I � L1 zaov I ❑ L2 I N EGC/ DC+ DC+ �- --- -------------- GEC ---TN DC- DC_ - MP 3&4:-1x13 __-_ EGC _--_� GND __ -'- -------- EGC----------------------------- Voc* = MAX VOC AT MIN TEMP OI (1)Gro qd Rod B (1)CUTLER-HAMMER /DG222NR8 52x2 STRINGS, SUNFUSED,GROUNDED C 5x1. x 8, Copper Disconnect; 60A, 24OVoc, Fusible, NEMA 3R -(2)ILSCO { IPC 40-#6 C (1)CUTLER-HAMMER #DG221URB PV -(16)SOLAREDGE 3 Optimizer, 34AZS Insulation Piercing Connector; Main 4/0-4, Tap 6-14 Disconnect; 30A, 24OVac, Non-Fusible, NEMA 3R PowerBox ptimizer, 300W, H4, DC to DC, ZEP SCSUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE _(1)CUTLER-�iAMMER k DG03ONB AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Ground/Neutral It; 30A, General Duty(DG) l--J (1)BRYANT# 1 P Load Center,er; 125A25A,, 1 120/240V, NEMA 3R -(3)Bred er H 2OAEf 2p!2 Spaces _.___. .._...... _ ..._.__. _.... __._. _ _ __..._ ._ . __ _._._ _..._..... ___..._..... . _.......__ ... _.__ __.... } ._....._ -_.__ Block * - �(1 AWG #6 THWN-2, Black ��T (1)AWG X10, THWN-2, Black (1)AWG /10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG 0, PV Wire, 600V, Bladc Voc 500 VDC Isc =15 ADC ®Icnl-(1)AWG /6, THWN-2, Red O IoF (1)AWG #10, THWN-2, Red O (1)AWG /10, 1HWN-2, Red Vmp =350 VDC Imp=11.73 ADC 1 (1)AWG X10, Solid Bare Copper EGC Vmp -350 VDC Imp=11.73 ADC (1)AWG6, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC L6^.JL_(1)AWG X10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1)AWG X10, THHN/THWN-2, Green EG -(1)Conduit Kit; 3/4' EMT -(1)AWG /6,.Solid Bare,Copper, GEC. . . .-0)Conduit Kit;.3/4'.EMT, . , . . _ ; . , , . , ,-,(1)AWG#8,,TF1WN-2,,Green . . EGC/GEC (1)Conduit.Kit;,3/4".EMT . . . . . . 1 i PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: g-0101849 00 David Alcocer ,`!a C0����'�� j CONTAINED SHALL NOT BE USED FOR THE ANDREW WOODLAND Andrew Woodland RESIDENCE J ,J/® BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: A NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 907 WESTHAMPTON ROAD 4.16 KW PV ARRAY f%ART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTHAMPTON, M A 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH24 St.Martin Drive, Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME SHEET REV: DATE Marlborough,38-1028MA 50) SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1028 F. (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE380OA-USOOOSNR2 THREE LINE DIAGRAM PV 4 a 3/16/2016 (666>-sat-CITY(�65-2489> www.sdarcity.c�, Label WARNING:PHOTOVOLTAIC POWER SOURCE Location: Label Location: LabelLocation: Code: Code: Per Code:Per NEC '• ELECTRIC.SHOCK HAZARDNEC ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS ' THE DC CONDUCTORS OF THIS ' Label Location: TERMINALS ON BOTH LINE'AND PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN PHOTOVOLTAIC DC LOAD,SlDESMAYBEENERGlZED UNGROUNDED AND Code: •- IN THE OPEN POSITION MAY BE ENERGIZED -• - DISCONNECTPer UNGUNDED NEC .•0 Label LabelLocation: PHOTOVOLTAIC POINT OF -• MAXIMUM POWER- INTERCONNECTION Per • _ Per POINT CURRENT{Imp)_AWARNING: ELECTRIC SHOCK MAXIMUM POWER-- Code: HAZARD. DO NOT TOUCH 690.17.4; 690.54 POINT VOLTAGE{Vmp) vNEC 690.53 TERMINALS.TERMINALS ON MAXIMUM SYSTEM_ BOTH THE LINE AND LOAD SIDE VOLTAGE{Voc) v MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION. FOR SERVICE CURRENT(isc) A DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT - MAXIMUM AC Label Location: OPERATING VOLTAGE - V WARNING ' Per ..- ELECTRIC SHOCK HAZARD 690.5(C) IF A GROUND FAULT IS INDICATED NORMALLY GROUNDEDLabel L• • UNGROUNDDEDOAND ENERGIZED CAUTION • DUAL POWER SOURCE Per ••- SECOND SOURCE IS 690.64.B.4 PHOTOVOLTAIC SYSTEM Label • • Label Per Code: _ ELECTRICAL SHOCK HAZARD ' ' DO NOT TOUCH TERMINALSNEC 690CAUTION ') (POI _•Code: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM Per " LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CIRCUIT IS BACKFEDNEC 690.64.B.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • WARNING '• Per Code: INVERTER OUTPUT Label ' • CONNECTION 690.64.B.7 PHOTOVOLTAIC AC -• DO NOT RELOCATEDisconnect DISCONNECT Code: THIS ODEVICERRENT (C): Conduit NEC .•0 :. DistributionPanel Conduit(DC): DC Disconnect Label Location: (IC): Interior Run MAXIMUM AC � A -• (INV): Inverter With Integrated DC Disconnect Per Code:OPERATING CURRENT A ''• Center MAXIMUM AC (M): Utility Meter OPERATING VOLTAGE VNEC 690.54 -• Point of • • W., •0 •• • • • ' (888)-SOL-CITY(765-2489)www.solarcity.corn S� a r'=@@SolarEdge Power Optimizer SoIar' Module Add-On for North America P300 I D350 P400 SolarEdge Power Optimizer ____ ___ P300... P350 P400 Module Add-On For North America (formodules) PV "modules)or 72-11 (formodule PV modules) maduCes} modules) INPUT P300 P350 P400 Rater'input DC Po er'� _.. _. __. 300 _ _.350 ___ _400 W ® Absolute P.63ximum Inpot Voltage(Voc at I,^,wes:temperature) 48 60 80 Vdc y' 8-48 8-60 8-8u Vdc '.. „� ,C ����°' MPfT Gper ating Range - �� ammu r�C rcu. u,rent(:sc) 10 Ad, M Sho C 32 51A • Maximum DCinput: Current 125 Ad, ' � �� aAl Max burr Ettccy 345 t ` 1`•r �,'` a Weighted EHicien y 98,8 � � I - # & OUTPUT DURINGYOPERATION(POWER OPTIMIZER CONNECTED TO.OPERATI NG INVERTER) _ Maximum Output Current 5 _ Aa_ Max mum OutputVoltage _ 60 _ _. Vac �� % • OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Opbr zer _ i - Vee " STANARD COMPLIANCE 6woo 6 sicCPar sr assi. EC6_o0n6 ,l�EMc fid,,... ,O ��" ,- Safety 'kC62.104_(class.i safety),l;.14: Yes INSTALLATION SPECIFICATIONS �OVdcOCN xi um Allowed System Vo+age _ Umcr wrs(WxLxH) 141 z.2i2x405/i55x 8.44x 153 mm in We&h incwdng cables} 950/21 - gr/Ib inputConnector MC4/Arrohenol/Tyco ticut Wire"ype Connector Double Insulated Arnphecol Output Wire Length 0.451 3.0 ',. 1.2 i 39 m 1 ft _ Operating Temperature Range -40-+II5/-40-r1_85 f F Protecton Rating IP65/NEMA4 RelaCve'Humidity 0-100 Fined AC Power of iie moatle.M-1- uP m.5%power rale oncea oweA. PV SYSTEM DESIGN USING A SOLAREDGE - SINGLE PHASE THREE PHASE THREE PHASE INVERTER _.......208V -480V PV power optimM2atlon at the madcase4eu�l .Minimum String Length(Power Optimizers} 8 .o 'R Maximum String Length(Power Optimizers) 25 25 50 Up to 25'a more energy p g Maximum Power per String 5250 ' 6000 12760 W Sllperlorefiiciency(99,5%) Parallel Stings of Different Lengths or Orientations ! Yes j Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading Flexible system design for maximum space utilization '.� Fast installation with'.a single batt ^ Next generation maintenance with module level monitoring ^ Module-level voltage shutdown for installer and firefighter safety THE Vin amountMMDU LE TSM-PD05.18 Mono Multi Solutions DIMENSIONS OF PV MOIDULE ELECTRICAL DATA I STC unihmisin Peak Power Watts-PMAX(Wp) 245 250 255 260 941 ---- Power Output Tolerance-P.- 0-+3 JUNCTIGN 3. Power Voltage-Vmp(V) 29.9 30.3 30-5 30.6 PF Maximum Power Current-l-(A) 8.20 8.27 8.37 8.50 THE Tir i na o u nMaxlmum t _NA-L- Open Circuit Voltage-Vac(V) 37.8 38.0 38.1 38.2 NSiALLING MOLE Short Circuit Current-lsc(A) 8.75 8,79 8.88 9.00 Module Efficiency rir, 15.0 15,3 15,6 15.9 tt M STC:Irradiance 1000 W/ml,Cell Temperature 25°C,Air Mass AMI,5 according to EN 60904-3,LE Typical efficiency reduction of 4,57 of 200 Wlms according to EN 60904-1 HECTIR:CAL DATANOCT Maximum Prower-P.-(Wp) 182 186 190 493 60 CELL Maximum Power Voltage-Vmp(V) 27.6 28.0 28J 28.3 MULTICRYSTALLINE MODULE 1-GeoUNDINIGHOLE Maximum Power Current-Imm(A) 6.59 6.65 6.74 6.84 WITH TRINAMOUNT FRAME /l uir-Aistr A -A Open Circuit Voltage(V)-Voc(V) 35.1 3S,2 35.3 35,4 Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 7.27 NOCT Irradia rice at 800 W/m Ambient Temperature 20°C,Wind Speed 1 m/s siz � - � 0'WAW' PD05.18 Back Via. -VIC, POWER OUTPUT RANGE MECHANICAL DAsA Fast and simple to install through drop in mounting solution -1 Solar cells Multicrystalline 156 x 156 Firm(6 inches) Cell orientation 60 cells(6 x 10) Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) Weight 21.3 kg(47.0 lbs) MAXIMUM EFFICIENCY Glass 3.2 mm(0.13 inches).High Transmission,AR Coated Tempered Glass A-X Backsheet White Good aesthetics for residential applications Frame Black Anodized Alum inivm Alloy with Trinamou nt Groove 0 0%0+ All 11- I-V CURVES OF PV MODULE(245W) J-Box IP 65 or IP 67 rated 3,70 Cables Photovoltaic Technology cable 4.0 mm2(0.006 inches2), ............................ to,- 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 9.- IWOWIm, FU. Fire Rating Type 2 Highly reliable due to stringent quality control Q F's 80oW/m26.- 1500W/m� W'- 5.- v, 4.-: 400WIFfirl Elim T, °FaATt.G5 MAXINWNA RATINGS i,."" rs-r ei 0-fen U ro, I d c i,` �i2.- 200W/m= Nominal Operating Cell Operational Temperature -40-851C Temperature(NOCT) 44-C(±2-C) cfli��rr) v rs U, c o Maximum System 1000VDC(lEC) 0.41%/1C Voltage 1000V OC(UL) Oro 0'. IOP, 20.- 30, 4l Temperature Coefficient of P- Temperature Coefficient of V- g 0.32%/'C Max Series Fuse Rating 15A Certified to withstand challenging environmental Temperature Coefficient of kc 0,05%/'C conditions W ANTY ARK 10 year Product Workmanship Warranty 25 year Linear Power Warranty (Please refer to product warranty for details) < CERTIFICAVON LINEAR PERFORMANCE WARRANTYPACKAGING COsqFIGL,�i.TTj10n c' I < 10 Year Product warranty- 25 Year Linear Power Warranty .ca- yrinsd Scher(l -- ............. us= Modules per box:26 pieces I ":-`1� -,- :Z Modules per 40'container:728 pieces �100% ............ ..... ....................... a Eu-26W EE COMPLIANT 90% olar's nt), CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 'Otiti`4,4p 02014Trina Solar Limited All rights reserved Specifications included in this d.t.sheet are subject to Trinasolar 80% Trinasolar change ithoutnotice SZ,-�3rt E Years 5 10 Is 20 25 MPO, THE TrInamount MODULE TSM-PDO5.18 Mono Multi Solutions --------------------- DHAENSIONS OF PV MODULE ELECTRICAL DATA:�STC unt snm Peak Power Watts-P-(Wp) 250 255 260 265 941 Power Output T0ler0nCe-P-X 0-+3 Maximum Power Voltage-V.,(V) 30.3 30.5 30.6 30.8 o 1-Ch. eoxI 10 maximum Power Current-Imir,(A) 8.27 8.37 8.50 8.61 rAMEPU _ Open Circuit Voltage-Voc(V) 38.0 38.1 38.2 38.3 THE Tr i na mu U I I I IT, Short Circuit Current Isc JA) 8.79 8.88 9.00 9.10 Z Module Efficiency rlm 15.3 15.6 15,9 16.2 SIC Irradiance l000 W/hi Cell Temperature 25�C,Air Mass AM1.5 according to EN 60904-3, MODULE Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1, E C T=I IC A., ATA N 0 CCT Maximum Power-P.-(Wip) 186 190 193 197 Maximum Power.Voltage-V-(V) 28.0 28.1 28-3 28.4 6 0 ki-E OLL maximum Power Current-l-(A) 6.65 614 6.84 6.93 MULTI CRYSTALLI N E MODULE A_ _A Open Circuit Voltage(V)-V-M 35.2 35.3 35.4 35.5 GflOUNO NG HOLE PD05.18 Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 WITH TRINAMOUNT FRAME NOCT irradiance at Boo W/M2,Ambient Temperature 20°C.Wind Speed I m/s. 812 250-265'WAW' Back View MECHANIC-A!,DATA POWER OUTPUT RANGE Solar cells Multicrystalline 156-156 ni(6 inches) 11 Cell orientation 60 cells(6.x 10) '4 Fast and simple to install through drop in mounting sciution module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) UdF © Weight 196 kg(43,12 lbs) Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass 16.2'z Backsheet White MAXIMUM EFFICIENCY A-A Frame Black Anodized Aluminium Alloy Good aesthetics for residential applications J-Box IP 15 or IP 67 rated A% Cables Photovoltaic Technology cable 4.0 hi(0.006 inci U 01 1200 mm(47.2 inches) 370 t-V CuRvc�or,PV MOD i.F(vi�()rw Connector lik[Ampherfol POSITIVE POWER TOLERANCE '.0o Fire Type UL 1703 Type 2 for Solar City Highly reliable due to stringent quality control 8..1, - - Thit U fO R A. ING,, D'oi lcl .......... E Pi RA U R E RATI N Gc N!A XI Operational Temperature -40--85'C Nominal Operating Cell ex, F:'- 44-C(±20C) si, .......... Temerature(NOCT)p IOGOVDCOECI Maximum System J000VDC(ULj Temperature Coefficient of P-x -0.417./'C voltage 2.1 .......... V Temperature Coefficient of V- -0.32%/'C Max Series Fuse Rating 15A Temperature Coefficient of hc 0.05%/'C Certified to withstand challengi21) song environnnental alt ter, conditions WARRANTY -f 0 10 year Product Workmanship Warranty �0 Vy, CERTIFICAION 25 year Linear Power Warranty fl�Jfi­l,� b- o CIP, (Please refer to product warranty for details) dc VL vs 0usno i ic ct,jr PACKAGING CONFIGURATION a LINEAR PERFORMANCE WARRANTY d -v rT. a ............... COMPLIANT modules per box i 26 pieces 10 Year Product Warranty-25 Year Linear Power Warranty THIso Solar Urmied ............... .......... ...............-........... Modules per 40'container:728 pieces if? ne-.-", ----- _-- - a go% CAUTION'READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 'OtAPA"Ag a 20"Trina Solar Limited.All rights reserved.Specifications included in this clatasheet ere Subject to change without notice. 807 Trin-asolar Trin-asolaNa den rS, -C -y Inwvli r year' 5 10 15 20 25 solar - - Single Phase Inverters for North America solar=ee • • ,� SE3000A-US%SE3R00A-US/SE500OA-US/SE6000A-US SE760OA-1US/SE10000A-US/SE11400A-US SE3000A-US SE380OA-US SE5000A-US SE6000A-US SE760OA-US_ SE10000A-US 1. SE1140OA-US OUTPUT SolarEdge Single Phase Inverters . - _- 9980 @ 208V Nominal AC_mower Output 3000 3800 5000 6000 7600 11400 VA 10000 @240V 5400 @ 208V1 10800 @ 208V Max.AC Power Output 3300 41,50 6000 8350 12000 VA p 5450 @240V 10950 @240V For North America AC Output VoltageMlin:Nom.-Max ` ✓ 183-208-229 Vac SE300OA-US,7 SE380OA-U J SE500OA-US/SE600OA-US f AC Output Voltage Min:Nom.-Max" ✓ ✓ ✓ ✓ ✓ ✓ ✓ g+ -p �gg'q {+ ( �+r�y�gr��{�y g+ g51I�y I' 211-240 264Vac : J E t t3 VA� a.?) ,J G 1lJ i1UUA- a3 1 E[ 9�+U A�Ll AC Frequency Min.-Nom.-Max.1tl 59.3-60-60.5(with l-Il country seting 57-6C 60.5) htz 24 @ 208V 48 @ 208V - , �" Max.Coni mous Output Curren' _2 5 16 25 32 47.5 A 21 @ 24CV 42 @ 240V �. � .. " ,`:gym.,, i CFDI hras`�old 1 Itility.Monitoring,Islanding Protection,Chantry Configurable-hre5�ol05 Yep ..... _. ____ ..... .. es _. INPUT - _ - rn 1050 K00 6750 _. 102_1 .... 13 00 1�3.�0 W -. sfBr .,>y Maxlrnu �C Power 00 81 `�' ` Z ,�. transformer less,Un rounded Yes , x�2sa y Max.Input Voltage 500 Vdc 021" Nom.DC Input Voltage 325 @ 208V i 350 @ 240V V'dc _ j diW " 16.5 @ 208V 33 @ 208V c rr dr l i Max.Input Curie nt1�l 95 13 18 23 - 34.5 Adc r .+ajapn P 1,5.5 @ 240L' 30.5 @ 240V , 011 Max snpat S�ort r lino t Curren, 45 Adc nff r� 'rf Reve se-Pala Ity P,otPctlnn Yes > -Ground-Faultisolation Detect-on 600,krzSensitivity '. Maximum inverter Efficiencv 9?7 98.2 98 3 98.3 98 98 98 ` 975 @ 208V 47 @ 208V -. >fi CLC Wei hted E"icienc 97 5 98 97.5 975 97,5 �> g y 98.@ 240V 97.5 @ 240V Nighttime Power Cons.ampnon_ <2 S ..... _... `-4 ._ W .._ ADDITIONAL FEATURES - _ Supported Communication Interfaces ' TFS.95,RS732-FTfiernet;-7`g3ee Iop5onali Revenue Grade Data,ANSI C3.2.1 rptiacai�'I >; y� caoid Shutdown-NEC 2014 690.72 ---- Functionality enablew^en St IarPdge rap;d shutdown K t s installed'<t _ _- �,., STANDARD COMPLIANCE _ — - - - - - - Safety — — - ._ U 7 3 LI .SA 22_2 Grid Connection Standards 'E�9 El 4 98 v� ill. C Emissions C: part15 class 8 ... _...... ___ ...__ ........ ..... INSTALLATION SPECIFICATIONS AC output conduit size J AWG range 3��'rninimum/16-6 AWG 3/4;:minimur i J 8-3 AWG DC;n conduit size!N of strings/ 3/4"min:mum/1 2 strings; AWG range 31,4"minimum J 1 2 strings f 166 AWG 1.4-6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 3.0.5 j in f ;VixU•JxD) 30Sx12 Sx771�ISx31Sx184 n l > 775x37.5x260 Fi Weight with Safety Switch E1 2 i 23.2 54.7 J 24.:' 88 4/40A to,•'kg Natural convection - > Cooling Natural Convection _ and inte-ral Fans(user replaceable) fall(user replaceable) l The hest choke for 5olarEdge enabled systems Noise :25 <50 dBA Integrated arc fault protection("type 1)for NEC 2411690.11 compliance Min.-Max.Operating T--petature 13 to+14011 25 to 1­6011-40 to+50 version available"') F/-c Superior efficiency(98%) Protection.Rating NLMA 3R rot Small,lightweight and easy to install on provided bracketn For other regional settings please contact Solai-Edge Supp t. A higher current source may he used,the vertcr will 11, 't' p I current to the values stated. Built-In module-level monitoring livvenue Rapid nnkerter PSN1 SExx D51o0DNNR2(for 7600Wnverter:SE7600AU5002NNR2) Rape . i Internet connection through Ethernet or Wireless 40 version P/N.SExx A-Us000NNU4(for 7600Winven-SE7600A-US002NNU4). outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 su =:cROHS [... ' r ,;...:4 ,.•:- ;;. r1. :(.)` www-sol,r`�ed E_'.(...S