341 Soil Test 5/31/06 (2) No. PT-20-392
Commonwealth of Massachusetts
Northampton, Massachusetts
FORM11 -SOIL EVALUATOR FORM
Soil Suitability Assessment for On-site Disposal
Performed By:
Witnessed By:
Thomas S. Leue Date: 5/31/06
Ernie Mathieu, Town of Northampton
Location Address or Lot No.
Audubon Rd.-Private Drive-Lot 9. Nortt
New or Repair Construction: Construct New
Owner's Name. Address& Tel.#
ampton Jane Hill
c/o Goggins Realty, 8 Main St.
Florence, MA 0106.2
586-7000
Office Review
Published Soil Survey Available: No n Yes tg
Year Published: 1980 Publication Scale: 15840
Drainage Class: Well drained.
Soil Limitations: Severe effluent limitations; slow percs.
Soil Type: PbB, Paxton stony, fine sandy loam
Soil Map Unit:�.
Superficial Geologic Report Available: No N Yes
Year Published Pubon Scale:
Geologic Material (Map Unit)
Landform
Flood Insurance Rate Map:
Above 500 year flood boundary No Yes
Within 500 year flood boundary No Yes
Within 100 year flood boundary No Yes
Wetland Area:
National Wetland Inventory Map (map unit)
Wetlands Conservancy Program Map (map unit)
Current Water Resource Condition USGS): Month
Range: Above Normal Normal n Below Normal n
Other References Reviewed:
•
•
S
DEP APPROVED FORM - 12/07/95
Location Address or Lot No.:
Number:
FORM 11-SON,EVALUATOR FORM
Page 2 of 3
Audubon Rd.-Private Drive-Lot
9. Northampton
On-site Review
Deep Hole#: 2
Date: 5/31/06
Land Use- woodlot
Soil Evaluation Number: PT-20— 392
9:30 AM Time
Vegetation: hemlock and hardwoods
Slope (%): 2%
Distance in feet from:
Open Water Body: >150
Possible Wet Area: >100
Drinking Water Well: >150
Depth from
Surface
(inches)
Soil
Horizon
Weather: clear
Surface Stones: yes
Landform: till plain
Drainageway
Property Line
Other
>150
30
Soil Texture
(USDA)
Soil Color
(Munsell)
Soil
Mottling
(inches)
Other
(Structures, Stones, Boulders,
Consistency,%Gravel)
0 - 4
4 - 20
20 - 91
A
Bw
C
fine sandy
loam
fine sandy
loam
fine sandy
loam
10YR 5/8 no friable
10YR 5/4 no 10% gravel, friable
10YR 5/2 30 compact till, roots to 46"
Mottles
10YR 4/4 distinct, coarse
10YR 4/1 '.. >5%
*MINIMUM OF 2 HOLES REQUIRED AT EVERY PROPOSED DISPOSAL AREA
Comments:
Parent Material (geologic)- glacial till
Depth to Bedrock: Depth of Excavation:
Depth to Groundwater:
Standing Water in the Hole: YES Depth:
Weeping from Pit Face: YES Depth:
Estimated Seasonal High Groundwater:
DEP APPROVED FORM-12/07/95
91 inches
86 inches
82 inches
30 inches
' s � "l
/, � < < < 7 5 - //,
P
/
LOTS
/
/
13.62 acres.
PL
i
/ Notes: 9 series deep holes conducted 4-4-97
/ 5 series deep holes conducted 5-31-06
b
9-1
Gap in wall It
5-1 / __-PL
iii
9-2
PL
/'
•
' Called North j��
i j j' PL
/ easement ,'n
/ SYMBOLS
� � �� a Pere Test Site
�/ PL IDrep Hole Site
TT-T SITE PLAN Date: Owner: HOMESTEAD INC.
5/31/06 Jane Hill Thomas S. Leue R.S.
Audubon Rd. Lot 9
Scale: : 100' Revision Date: Leeds, MA 01053
Williamsburg,MA 01096
Exceept pt as Noted 1413]628-4533
Checklist for Septic System Plan Review - 3q/ Ae h, t Y
'Application page attached to plan (,(J�
3�/PE or R5 stamp, date, signature ii----
Variances to property line setback distances must have Surveyor stamp
• Legal boundaries noted
3/Easements noted
Dwellings and buildings existing or proposed noted
El/Location of driveway or parking areas,other impervious areas
3/ ocation and dimensions of reserve area(new construction only)
fystem design calculations
• Garbage grinder
• Benchmark not distyrbed during construction within 75ft of facility
North arrow 4/'
bn✓� Contours
d Deep hole location(s) and data
Perc hole location(s) and data
;j)/ levations
N es of approving authority and soil evaluator
location of water supplies, public and private
o Within 400ft of system in case of surface water and gravel-packed public water supply
o Within 250ft of system in case of tubular public water supply
o Within 100ft of system in case of private wells(50ft from tank)
r"Well statement, if applicable
d Location of any surface waters, rivers,vegetated wetlands
C- Location of water lines and other subsurface utilities
j/Obserrved and adjusted groundwater elevations in vicinity of system
Profile of system
71/4.ocus plan to show location of facility, including nearest street
• Materials of construction and specs for system
7/Gas baffle
• ,(,/-Pipe in center line of tank
'C/Double-washed stone
�Z�/Schedule 40 PVC for trafficked areas,house to tank
t/ Distances noted from house to tank, etc.
ki If dosing is proposed, design and specs of dosing system
/./-When alternative technology is required, complete plan and specs including hydraulic profile
3 wenches preferred over beds
'iuoyancy caleu4etions for tanks or components partly below groundwater level
E 3:1 slope outside of mound toe endin 5ft from properp line
0 1e a requests on the plan,all variances 4
O Local upgrade-utWs attached to the application
HERITAGE SURVEYS, INC.
Professional Surveyors and Engineers
241 College Hwy& Clark St, P O Box 1
Southampton, Massachusetts 01073-0001
Bruce A. Coombs, President
Professional Surveyor, MA, CT& VT
E-mail:bruce(Jheritagesurveys.com
Telephone(413)527-3600
Facsimile(413)527-8280
Website:heritagesurveys.com
LETTER OF TRANSMITTAL
TO: Northampton Board of Health
City of Northampton
210 Main St.
Northampton, MA 01060
DATE: April 9, 2014
JOB #: 7151-140212
SUBJECT: Elizabeth Vizentin & Barrett W. Newsome
341 Audubon Road
Leeds, MA
WE ARE SENDING YOU:
COPIES
DATE
PLAN #
DESCRIPTION
2
04/09/14
7151-
Copies of plans entitled, 34lAudubon Road -
140409
Lot 1, Plan of Proposed Sewage Disposal
System in Northampton MA, Prepared for
Elizabeth Vizentin & Barrett W. Newsome,
Sheets 1 & 2
2
04/09/14
N/A
Original & copy of Application for Disposal
System Construction Permit
2
05/31/06
N/A
Copy of Site Suitability Assessment for On-
04/04/97
Site Sewage Disposal (TP# 5-1, 5-2, 9-1, 9-2)
1
04/04/14
N/A
Check #872 in the amount of$150.00
Please contact this office if you should have any questions or comments
relative to the above.
Sincerely,
Mark P. Reed
Commonwealth of Massachusetts
City/Town of
Septic System Installation Checklist
aye A��a Eeti
ceatAsireichow
B. Application Checklist (cont)
2 Construction Inspection
a) Building Sewer(310 CMR 15.222)
All waste pipes bed into building sewer Basement check V
Ito ,
Schedule 40 PVC 4' or cast iron Verify by reading ppe J rl
is/e
Approv
V
Minimum slope of 0.01-0.02
Pipe laid in continuous straight line
Pipe laid on compact, firm base
Cleanouts precede if changes in
alignment/grade
Cleanout provided every 100 ft
BacldAl material clean
b) Septic Tank(310 CMR 15223)
Tank is set level with 6'stone under
(15228)
Tank is required size/loading per plan
Inlet and outlet are at proper location
(15.227)
Tank is water tight(15.226)
Outlet tees extend 6'above flow line
Approved fitter device placed at outlet
Gas bafe instated at outlet tee
Inlet and outlet tees on career line
Tank is backaked with acceptable mama
Notes:
Verify by visual/tape/
"
Verify by visuaUtape
N/A Problem
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
❑ ❑
Approved N/A Problem
Check with level /, Ch ve/ ❑ ❑
Verify with plan // f27--w ❑ ❑
Verify with plpn ✓/ i ❑ ❑
Test
r rle E' ❑ ❑
Verify by visuaWtepe ® ❑ ❑
DEPIi / :/ ❑ ❑
Vist / "Cc ❑ ❑
(.& 5 El ❑
❑ ❑
Fs*sywm ImaMlon Checklist I1-09.doc•eats
Farm Name•Paea 2 of 6
A
Commonwealth of Massachusetts
City/Town of
Septic System Installation Checklist
B. Application Checklist(cont)
c) Distribution Box(310 CMR 15.232)
All outlet pipes at same elevation
Number of outlets
A5libt I
Check by adding water
Number of laterals
Inlet tee min. 1'over outlet
D box set on level base
Top of 0 box 36'max depth /
D box is water-tight /77 h A
D box has a minimum of 2'thick wall
12'inside dimension
d) Pump Chamber(310 CMR 15.231)
Tank
end
w/tape
and w/tape
Add water
Approved
LA Problem
Approved
r
NIA Problem
/level
/t°✓C
Check plan and tank
Number of pumps:
Specified pump provided or designers
approval for equal pump
Correct pump sequence
Covers set to grade
Electrical permit provided
r of stone beneath chamber
Chamber is water-tight
Min. 9'cover provided
Correct loading provided per plan
Notes:
Visual
Test
Visual
Visual on tank
eapea Sys a,hnteeieon Ctrcki st 11-09.doc•dee
Fern Name•Pape 3 ore
Commonwealth of Massachusetts
City/Town of
Septic System Installation Checklist
B. Application Checklist(coat)
a) Leaching Facility(310 CMR 15.240)
No frozen material used including bad(fill Visua!
No clay, tailings or stones larger than 6'for
cover material
Soil at bottonvsides of excavation matches
info on deep holes
All impervious layers removed
No remaining NB horizons
Groundwater conditions match plan and
deep holes
Vented if under impervious cover per plan
(15.241)
Vent is protected from precipitation
and animal entry
Cover of a minimum of a•over leach area
Pipe slope equal to 0.005
Leath area per design(15241)
Excavation is level and at required depth
Vista
plan
V15 �h /
w ansl
Removal of 5 ft material and replacement pan
(if in ell)
Back fill material is acceptable
Final contours correct per plan
Surface/subsurface drainage away from
leach area
Fide grade and side slopes we stable
Distribution lines are capped, vented, or
convected together
Impermeable barns'(1 55(21)
Retaining wall inspected
Visual
Check with plan
Approved
❑ ❑
❑ ❑
❑ ❑
❑ ❑
t^L�// i❑ ❑
❑ ❑
❑ ❑
air/ o
Ei ❑ ❑
❑ ❑
/� ❑ ❑
2 ❑ ❑
❑ ❑
Lie ❑ ❑
❑ ❑
[B� ❑ ❑
❑ ❑
❑ ❑
❑ ❑
NIA Problem
Retaining wall is water-woofed
Retaining wall/barrier is at
depth/height
&epic%Sam keweaen Chet1St 11-00 doe•date
Form Hams•Pepe 4 ofa
Commonwealth of Massachusetts
City/Town of
Septic System Installation Checklist
B. Application Checklist(cont)
j) Certificate of Compliance(310 CMR 15.021)
As Burn Plan Submitted
Signed by Installer
Signed by Designer
Certificate of Compliance Issued
Notes.
Dale
wG
Ode
//
Date
//
Date
Sept System Inetabelon amebae 1 t dt.eoc•dale
Farm lane•Papa 6 of 6
Commonwealth of Massachusetts
CityITown of
Septic System Installation Checklist
B. Application Checklist(cont.)
f) Leaching trenches(310 CMR 15.251) Approved N/A Problem
Number of trenches. -- — ❑ ❑ ❑
Depth of trenches. ❑ ❑ ❑
Wdth of trenches ❑ ❑ ❑
Trench spacing per plan <✓ ❑ ❑
Stone is double-washed[3/4'to 1X'1(15247) ❑ ❑ LJ
g) Leaching fields(310 CMR 15.242)
Length of field: ❑ ❑ ❑
Wdth of field: ❑ ❑ ❑
Min. of 2 distribution lines ❑ ❑ ❑
Separation distance conforms to plan ❑ ❑ ❑
Stone is double-washed[314'to 1%'j(15247) ❑ ❑ ❑
h) Leaching Pits(310 CMR 15.253)
Number of pits. ❑ ❑ ❑
Depth of pits: ❑ ❑ ❑
stone is double-washed f314'to 1W1(15.247) ❑ ❑ ❑
Each pit has min. 1 20'access cover ❑ ❑ ❑
Piping network and configuration of ❑ ❑ ❑
pitafdlambers per plan
i) Tight Tank(310 CMR 15.260)
Tank is set level with 6'stone under Visual and with level ❑ ❑ ❑
Tank is proper size per plan Visual with plan ❑ ❑ ❑
Pumping contract has been provided ❑ ❑ ❑
Covers to grade Visual ❑ ❑ ❑
NV alarm set at 3/5 tank capacity Check floats by raising ❑ ❑ ❑
. An/alarm test on separate circuit Set off alarm ❑ ❑ ❑
spec Sperm 1. on Checklist 11-00.6a:•don
Fpm Menlo•Pape 5 of 6