32C-001 (48) Code Review Thomas Douglas Architects, Inc. Renovations to Herrell's Ice Cream Northampton, MA 01060 Thornes Marketplace 413-585-0641 Northampton, MA 01060 is only required to have the new elements meet the energy provisions and not the entire system. Any new replacement windows will have a maximum U value of 0.4 Any new entrance doors will have a maximum U value of o.8 None of the existing exterior walls or the roof are being altered, so no new insulation is required. 8o6 Accessibility CMR 521 3.3.1 b. If the work costs $ioo,000 or more, then the work being performed is required to comply with 521 CMR. In addition, an accessible public entrance and an accessible toilet room shall be provided. 3.3.2 If the work performed, including the exempted work, amounts to 30% or more of the full and fair cash value of the building, the entire building is required to comply with 521 CMR. On May 13, 2,015 The Architectural Access Board of Massachusetts granted 15o Main Street accessibility variances of all non-complying areas (Docket Number: V I 4-347). The new kitchen is accessible from the front entry. It is an employee only area. The toilet room in the employee only area is not regulated by the AAB. There is an existing raised floor area in Harrell s. It will remain. A new ramp connecting the interior of Thornes to Herrell's will be constructed as a separate project from Herrells. It will be complete when Herrell's requests a CO. End of Document 7 of 7 Code Review Thomas Douglas Architects, Inc. Renovations to Herrell's Ice Cream Northampton, MA 01060 Thornes Marketplace 413-585-0641 Northampton, MA 01060 705.4.4 Panic Hardware In level 2 work areas, Panic hardware is only required for A uses with occupancies over 100. This project does not have this occupancy count. 1008.1.10 panic hardware requirement 1008.1.9.3 Locks and Latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: Item 2 In buildings in occupancy Group A having an occupant load of 300 or less, ... the main exterior door or doors are permitted to be equipped with key- operated locking devices from the egress side provided: 2.1 The locking device is readily distinguishable as locked, 2.2 A readily visible durable sign is posted on the egress side on adjacent to the door stating "this door to remain unlocked when building is occupied. The sign shall be in letters 1 inch high on a contrasting background and, 2.3 The use of the key-operated locking device is revocable by the building official for due cause, 705.7 Exit Signs All means of egress shall have compliant exit signs. 705.7 Means of Egress lighting The tenant space shall have compliant egress lighting 711 and 607 Energy Conservation: Level and z alterations are permitted without requiring the entire building to comply with the International Energy Conservation Code. Alterations (new construction)shall comply with the International Energy Conservation Code. A building that undergoes Level z alterations is required to meet a certain level of energy compliance. Where there are reconfigurations of the space or new doors or windows, any such new element is required to meet the International Energy Conservation Code. Elements within the building that are not being affected do not heed to be evaluated and do not nee to comply with the energy provisions. Essentially the entire building is not required to meet the energy provisions; only a degree of possible improvement in the energy performance of the building is intended to be achieved by making the new elements meet the IECC. In certain cases where the reconfiguration of the space might have resulted in the creation of new spaces the newly created space should be evaluated as a whole for compliance with the energy provisions even though some of the element within the space might actually not have been altered. Likewise, in a case where an existing mechanical system is being extended to other areas or new ductwork is being installed to reconfigure and reroute the ducts to various spaces, it 6of7 Code Review Thomas Douglas Architects, Inc. Renovations to Herrell's Ice Cream Northampton, MA 01060 Thornes Marketplace 413-585-0641 Northampton, MA 01060 A building that undergoes Level a alterations is required to meet a certain level of energy compliance. Where there are reconfigurations of the space or new doors or windows, any such new element is required to meet the International Energy Conservation Code. Elements within the building that are not being affected do not need to be evaluated and do not nee to comply with the energy provisions. Essentially the entire building is not required to meet the energy provisions; only a degree of possible improvement in the energy performance of the building is intended to be achieved by making the new elements meet the IECC. In certain cases where the reconfiguration of the space might have resulted in the creation of new spaces the newly created space should be evaluated as a whole for compliance with the energy provisions even though some of the element within the space might actually not have been altered. Likewise, in a case where an existing mechanical system is being extended to other areas or new ductwork is being installed to reconfigure and reroute the ducts to various spaces, it is only required to have the new elements meet the energy provisions and not the entire system. There are no new exterior walls. Existing concrete floor slab:No changes to existing. Level a work requirements: The reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment. This Project will have a new kitchen area and a new retail service counter. (reconfiguration of space and equipment). 701.3 Compliance Windows may be added without the light and ventilation requirements of the IBC New electrical equipment must comply with section 7o8 Length of dead end corridors, comply with 705.6 There are no proposed dead end corridors. Minimum ceiling height of newly created habitable and occupied spaces shall be 7 feet. 705 Means of Egress The proposed tenant space will include z means of egress from 1St floor areas. The small 2nd floor of the new kitchen will have i means of egress. Low occupancy (6 people) and sprinklers make this this single egress allowable. 5 of 7 Code Review Thomas Douglas Architects, Inc. Renovations to Herrell's Ice Cream Northampton, MA 01060 Thornes Marketplace 413-585-0641 Northampton, MA 01060 Minimum ceiling height of newly created habitable and occupied spaces shall be 7'-6" feet. OCCUPANCY Occupant Load Calculation Max occupancy (1004.4.1) Herrell's Ice Cream 33 seats A-2 use 16 standing 10 employees Total: 59 Toilets: There are common toilets in the building within 300 feet. 704 Fire Protection: 704.z, 912.2.i Automatic sprinkler systems Automatic sprinkler systems will be upgraded in the work area as needed. 705 Means of Egress The proposed work will include z means of egress. There will not be a reduction of means of egress in any part of the building. IBC Table ioi6.i Exit Access Travel Distance: For a-z use and sprinklers: 250 ft maximum allowable travel distance. The travel distance is less than 250 feet to an exit door. 705.4.4 Panic Hardware Panic hardware will be installed on all exit doors. 705.7 Means of Egress lighting All means of egress will have compliant exit signs. 705.7 Exit Signs The renovated space will have compliant egress lighting Iii and 607 Energy Conservation: Level 1 alterations are permitted without requiring the entire building to comply with the International Energy Conservation Code. Alterations (new construction) shall comply with the International Energy Conservation Code. 4of7 Code Review Thomas Douglas Architects, Inc. Renovations to Herrell's Ice Cream Northampton, MA 01060 Thornes Marketplace 413-585-0641 Northampton, MA 01060 Floor construction and o secondary members Roof construction and o secondary members Work Area Method Calculations The total building area is 76,786 square feet. The existing renovated space is z stories, 2,847 square feet The work area is 3.7% of the aggregate area of the building. The work area comprises less than 50% of aggregate area of the building; therefore this is not a level 3-alteration project. IEBC section 405) The work area includes reconfiguration of the space, the addition new interior opening and the reconfiguration of systems (HVAC). Most of this project will be classified as a level z project. Part of the project will be classified as a level 1 project. The alterations will follow level 2 guidelines. Level i work requirements: The removal and replacement or the covering of existing materials, elements, equipment or fixtures using new materials, elements, equipment or fixtures that serves the same purpose This Project will have new interior walls, doors,finishes and lighting. 602.1 Interior finishes:All newly installed wall and ceiling finishes shall comply with the IBC. 603 Fire Protection: Alterations shall be done in a manner that maintains the level of fire protection provided. This Project will not affect the level of fire protection that is currently provided. 604 Means of Egress Repairs shall be made in a manner that maintains the level of protection provided for the means of egress. 606 Structural: None proposed 607 Energy Conservation: See 711 below 701.3 Compliance New electrical equipment must comply with section 708 3 of 7 Code Review Thomas Douglas Architects, Inc. Renovations to Herrell's Ice Cream Northampton, MA 01060 Thornes Marketplace 413-585-0641 Northampton, MA 01060 3 1St floor: 16,440 sf 4. 2 nd floor: 16,522 Sf 5. 3 rd floor: 16,522 Sf Total: 76,876 sf Proposed work areas by use: A-2 area proposed: New kitchen, 1St floor 615 sf New kitchen, 2nd floor 593 sf Existing 1St floor retail space 1,112 Sf Total proposed work area: 2,31��sf 704 Fire Protection:The building will be fully sprinkled. There are existing sprinklers in a portion of the existing space. We are reconfiguring the sprinkler layout in the work area to conform to the new layout. There will be no modifications to the areas outside of the work area. 704.4 Fire alarm and detection: • The building has a fire alarm system in all areas. It will be maintained and altered as necessary in the work area. According to the IEBC this renovation is being reviewed as: Work Area Method, Chapter 4. Applicable Sections are: Chapter 6-Alterations Level 1- New finishes and fixtures Chapter 7-Alterations Level 2 - New construction. Fire Resistive Required Types of Building Element Type 3B Construction, Table 6o1 IBC Primary Structural o Frame Bearing walls, Exterior 2 Bearing walls, Interior o Nonbearing walls and o partitions, exterior Nonbearing walls and o partitions, interior 2of7 Code Review Thomas Douglas Architects, Inc. Renovations to Herrell's Ice Cream Northampton, MA 01060 Thornes Marketplace 413-585-0641 Northampton, MA 01060 CODE REVIEW December 17, 2015 Thornes Marketplace Herrell's 150 Main Street Northampton, MA Applicable Building Code: MA 78o CMR Eighth Addition IBC, IEBC International EXISTING Building Code, 2009 ZONING DISTRICT: CB Proposed Renovations: Project Description: • Renovate storage, mechanical, and business areas for tenant use. Use Groups • The space combination of a current A-2 use and a former B or A use (L'Oasis, Night club). • The proposed use is A-2 Assembly. No change of use is proposed for the work areas. • The current level of safety or sanitation will NOT be reduced and the portions altered shall conform to the requirements of the IBC, including interior finishes, interior floor finishes, and interior trim. Construction Type • 3B Valuation of Project: • This project's construction costs are: $11o,000 • The assessed value of the building is: $3,854,400 • The cost of the project is 2.8°,x, of the assessed valuation. Areas The total building area is 76,876 square feet. The proposed renovated work area is: 2 story, 2,847 square feet Existing Areas by floor: 1. Ground floor: 10,720 sf 2. Lower Level: 16,582 sf 1 of 7 Initial Construction Control Document To be submitted with the building permit application by a Registered Design Professional for work per the 8th edition of the r Massachusetts State Building Code, 780 CMR, Section 107.6.2 Project Title: Herrel's Ice Cream Date: 15 January 2016 _ Property Address: 8 Old South St, Northampton,MA 01060 Project: Check one or both as applicable: New construction X Existing Construction Project description: _ Renovation of existing restaurant, construction of new commercial kitchen in adjacent annex 1 Thomas Douglas _MA Registration Number: _ 8944 Expiration date:_ 8/30/16 _,am a registered design prgfessional, and hereby certify that i have prepared or directly supervised the preparation of all design plans,computations and specifications concerning: [M Entire Project [ ] Architectural [ ] Structural [ ] Mechanical [ ] Dire Protection [ ] Electrical [ ] Other for the above named project and that such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code,(780 CMR),and accepted engineering practices for the proposed project. I understand and agree that I (or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: I. Review, for conformance to this code and the design concept, shop drawings,samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17, as applicable. I Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. When required by the building official. 1 shall submit field/progress reports(see item 3.)together with pertinent comments, in a form acceptable to the building official. Upon completion of the work. I shall submit to the official a `1=inal Construction Control Document'. 7 Enter in the space to the right a"wet"or , � electronic signature and sea]: < Phone number: 413.585.0641 : .3 Email: douglas @tdouglasarchitects.com Building Official Use Only Buildintt Official Name: Permit No.: hatc: 'trial Version 10 09 2013 51 P� e Crzt�r 'Wartilaillptall assnchnsctta' DEPARTMENT OP BUILDING INSPECTIONS 212 Main Street ' Municipal Building ' Northampton, Asass. TOGO WORICER'S COMPENSATION INSURANCE A]~MI AVIT Pioneer Contractors «ith a principal place of business/residence at: ,_,P.O. Box 1141; Northam=ton 1yp1 061 —(Phone') 586-5491 (str-e-,..t/ci ty/statdziP) do hereby certify, under the pains and penalties of perjury-, ttiat. ( I am an employer providing the following worker's couYpcnsatioo coverage for my employees wor dog on this job: ASSoriated Employer G Ins Wcc 50059570120012 (Insurance Company) (Poticy NuaLL-er) (Expi 2tio D=) ( ) I am a sole proprietor, general conn-actor or homeowner (circie one) and have hired the contractors listed below who have the following worker's compensation policies: (Name of Contractor) (Lasurance Company/PoLicy Number) (Iixpiration Date) r (Name of Contractor) (Insurance Company/Policy number) (Expimdon Date) (Name of Connector) (Insurance Compaoy/Poficy Number) (Expiration Date) (Name of Contractor) (Insurance Company/Policy Number) (Expiration Date) (attach additioosl ahccc if oeassAry to iocludc irtfQrou ion pertaining to all wafts data) ( ) I am a sole proprietor and have no one w,orldng for me. ( ) I am a home owner performing all the work myself. NOTE:Plisse be atrue that Virile boa=mw wbo employ Pawns to do� � coastrwjoa or repair wueK oa a dv_aiag of na more than Llano units is wwch the bomoawuer rcxidco a an the pvuocb appuctenaut tb wao arc not sesaarly considered to be ccaploycrs uodcx tbo worker's a=Vcns4oa Act(GLL52,s 1(5)1 apptic%doo by a bomoouma for a Geanx or permit may C%idmoc the kgar status of an employer under the Workoes Compematioo Aa- 1 underaand dui a copy of this%=L meal may bo tawwilad to tbo Depart oont of i a,,,rrial Aocide.'Of oo of taswt000 for!).e covcczsc verifiestioo sad that failure to roc=oovcragt,coder section 25A of MOL 152 can Iced to rho imp.uition of a--3l Paoaltia oomisttmg of a 6me of tap to S 1,$00.00 sailor miprbomncca of tip to one yesr and civic pcwl6cz in the form of a Stop W-k Onus soda find o(S100.00 a day Lgaimi mt- For dcp tD=3 !use ootY Permit Number I I map# Lot# "r a Si ruins of Lict�tuxJPcrrai _ City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: I-V ( tom- -�i The debris will be transported by: The debris debris will be received by: VA Lk�A; Building permit number: Name of Permit Applicant Date Signature of Permit Applicant Versionl.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes Q No SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT as Owner of the subject property hereby authorize c 64 1 � t�✓ ,, 3�G` to ct on m be alf, in all matters relative to work authorized b this buiklin pp y g perms a ication. Signature of Owner tV�SL �Q.� - Oate *uthorized Agen ereby declare that the statements and information on the foregoing application are true and accurate,to the best of y-kn edge elief. Signed under the pains.and penalties of perjury,, Print Name , Signature of Agent Date SECTION 12-CONSTRUCTION SERVICES Name of License Holder; Supervisor: Not Applicable ❑ .1 Licensed Construction _ _.____........... License pumber Expiration Date - I Address _ rat P Signature Telephone SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the b 'kung permit. tn Signed Affidavit Attached Yes No Version 1.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: N Applicable 01 ......------- ❑ Name(Reglstrant): 2 Registration Number Address Expiration Date Signature Telephone -9.2 Registered Professional Engineer(s): Name Area of Responsibility—' Address Registration Number L Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Not Applicable ❑ Company Name: Responsible In Charge of Construction v Address VSna—/— Telephone Version 1.7 Commercial Building Permit May 15,2000 8. NORTHAMPTgN wN>N . Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size _. f ' u Frontage Setbacks Front Side U:1-- _ R•!.._..._......, L:, R:h "._.......k Rear Building Height Bldg.Square Footage _. ....... __._ "fie Open Space Footage % (LW area minus bldg&paved parking) #of Parking Spaces ---- Fill: volume&Location A. Has a Special Permit/Variance/Finding ver been issued for/on the site? NO Q DONT KNOW YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO Q DONT KNOW 0 YES Q _.__...... ... ... ...W r, _.. IF YES: enter Book Page' and/or Document# B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained a Obtained ® , Date Issued: C. Do any signs exist on the property? YES / NO Q IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO (D" IF YES, describe size, type and location: , E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Version 1.7 Commercial Building Permit May 15,2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations Existing Wall Signs ❑ Demolition❑ Repairs❑ Additions ❑ Accessory Building❑ Exterior Alteration Existing Ground Sign❑ New Signs❑ Roofing❑ Change of Use❑ Other❑ Brief Description !Enter a brief description here. Of Proposed Work: ' SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicabl ) CONSTRUCTION TYPE A Assembly ❑ A-1 ❑ A-2 15 A-3 ❑ 1A ❑ A4 ❑ A-5 ❑ 1113 ❑ B Business ❑ 2A ❑ E Educational ❑ 2B 0 F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ I Institutional ❑ 1-1 ❑ 1-2 p 1-3 ❑ 38 lay M Mercantile ❑ 4 ❑ R Residential ❑ R-1 ❑ R-2 ❑ R-3 ❑ 5A ❑ S Storage ❑ S-1 ❑ S-2 ❑ 5B ❑ U Utility Specify: M Mixed Use ❑ Specify: S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS ANDI CHANGE IN USE Existing Use Group: !.__ .. ,.1 �.._. - .. ._... . Proposed Use Group: Existing Hazard Index 780 CMR 34): _ _._,.._ .. ... _._ Proposed Hazard Index 780 CMR 34): SECTION 8 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION C?FI:ICE USE ONLY I, Floor Area per Floor(so a 1 u 1 4r r 2nd 2"d _ uII _ 3rd ' 3nd _ th 4 , 4 m I Total Area(so Total Proposed New Construction s Total Height(ft) Total Height ft J` hl 7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public 52/ Private ❑ Zone', Outside Flood Zone Municipal On site disposal system❑ Version 1.7 Commercial Building Permit Ma 15,2000 City of Northampton Building Department 212 Main Street Roam 100 Northampton, MA 01060 phone 413-587-1240 Fax 413-587-1272 APPLICATION TO CONSTRUCT,REPAIR,RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION P Y 1.1 Property Address: s sect,on to e�com completed b office i Map Lot Unit —TIn' !`J1v- zone Overlay District c a Elm St:D1tHt CB"D .. _, Istrlct° SECTION 2-PROPERTY OWNERSHIPIAUTHORIZED AGENT 2.1 Owner of Record: Name(Print) W_- Current.Malting Address . ._......... 0i Signature Telephone 2.2 Authorized Aaent: Name(Print) Cu ( )_._. ..__ Current Maili Address �1 ! 4 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building (a)Building Permit Fee t 2. Electrical (b)Estimated Total Cost of mm w L'd"L,7 ez, " Construction from 6 _. 3. Plumbing i It tV,(Z)i Building Permit Fee 4. Mechanical 5. Fire Protection VAC _ ,J _ i 6. Total=0 + 3+4+5) P'V7 Check Number This Section For Official Use Only If Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date File#BP-2016-0929 APPLICANT/CONTACT PERSON PIONEER CONTRACTORS ADDRESS/PHONE PO Box 1145 NORTHAMPTON01061 (413)586-5491 PROPERTY LOCATION 150 MAIN ST-HERRELL'S MAP 32C PARCEL 001 001 ZONE CB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: RENOVATE STORAGE MECHANICAL&BUSINESS AREAS FOR TENANT New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: - Owner/Statement or License 017890 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO MATION PRESENTED: proved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay L 1( k ► I z9 6 Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning& Development for more information. 150 MAIN ST-HERRELL'S BP-2016-0929 GIs 4: COMMONWEALTH OF MASSACHUSETTS MapBlock: 32C-001 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:renovation BUILDING PERMIT Permit# BP-2016-0929 Project 4 JS-2016-001572 Est. Cost: $110000.00 Fee: $770.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: PIONEER CONTRACTORS 017890 Lot Size(sq. ft.): 16683.48 Owner: THORNES MARKETPLACE LLC C/O HPMG zoninc: CB(100)/ Applicant: PIONEER CONTRACTORS AT. 150 MAIN ST - HERRELL'S Applicant Address: Phone: Insurance: PO Box 1145 (413) 586-5491 Workers Compensation NORTHAMPTONMA01061 ISSUED ON:21112016 0:00:00 TO PERFORM THE FOLLOWING WORK.RENOVATE STORAGE,MECHANICAL & BUSINESS AREAS FOR TENANT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy si nature: FeeType• Date Paid: Amount: Building 2/1/2016 0:00:00 $770.00 212 Main Street,Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner