Loading...
17D-050 (2) ''etl Wtth 0�' ��■ r, RSSTm Rugged Structural Screws: Ideal for anywhere you would use a traditional lag screw and more,without pre-drilling. High tensile torque and shear strength means a 5/16" diameter RSST"' screw has the same strength as a 1/2" lag screw. Available from#10 up to 3/8"diameters in lengths D�o from 1-1/2"to 16". Approved for use in all applications that include treated lumber. Also available in PHEINOXTM Stainless Steel, RSSTM JTS used for joists and trusses, RSSTm LPS for structural insulated panel systems and RSSTm LTF designed for log home and timber frames. FASTENER OVERALL LENGTH OF MINOR SHANK OUTSIDE ALLOWABLE STEEL STRENGTH DESIGNATION LENGTH' THREAD THREAD DIAMETER' THREAD (inches) (inches) DIAMETER' (inches) DIAMETER Bending Tensile Shear (inches) (inches) Yield (psi) (psi) Strength [pounds] [pounds] Fyb(Psi) 1/4 x 2 1/2'"_ 23/8 1 1/2 74 x 3 1/8" 31/8 2 0.150 0.169 0.239 170,427 188,301 127,792 1/4 x 31/2" 31/2 2 3/8 [3,336] [2,264] 5/16 x 2 1 12" 23/8 1 1/2 5/16 x 2 3/4" 23/4 13/4 5/16 x 3 118" 31/8 21/8 5/16 x 31/2" 3 112 2 112 0.174 0.199 0.280 190,920 178,051 123,592 5/16 x 4" 3 718 23/4 [4,247] [2,948] 5116 x 5 118" 5 31/2 5/16 x 6" 57/8 37/8 3/8 x 3 118" 31/8 2118 3/8 x 4" 37/8 23/4 3/8'x 5 1/8" 51/8 31/2 318 x 6" 5 718 4 3/8 x 7 1/4" 7 41/2 203,809 129,305 3/8'x 8" 7 7/8 4 3/8 0.191 0.223 0.310 178,080 [5,824] [3,695] 3/8 x 10" 93/4 5 3/8 x 12" 117/8 57/8 3/8'x 14118" 141/8 57/8 3/8 x 16" 155/8 53/4 0. 114 x 8" 77/8 27/8 0.152 0.172 0.238 172,620 172,950 109,635 [3,155] [2,000] 3/8 x 8" 77/8 37/8 179,390 114,525 H 3/8',x 10" 97/8 37/8 0.191 0.220 0.310 167,580 3/8'x_12 113/4 37/8 [5,144] [3,284] 1/4 x 21/2" 2 318 1 1/2 0.152 0.170 0.237 111,460 103,799 90,260 [1,886] [1,640] O 5/16 x 21/2" 23/8 15/8 z 5/16 x 3 1/8" 3 118 21/8 W 104,767 86,880 = 5/16 x 4" 3 718 21/2 0.171 0.195 0.276 118,360 tt 5/16 x 5 1/8" 51/8 33/8 [2,419] [2,006] 5/16 x 6 57/8 3 718 1/4 x 3 3/8" 3 318 13/8 1 1/4 x 5" 5 1 5/8 0.153 0.173 0.240 226,373 180,999 126,131 1/4'x 6 3/4" 1 6 314 1 1/2 [3,312] [2,308] For SI: 1 inch=25.4 mm;1 psi=6.9 kPa. ULTIMATE LOAD VALUES TENSILE AND SHEAR DRIVE WITH SPEED, QUALITY& CONFIDENCE OherGrade" WWW.GRKFASTENERS.COM 800.263.0463 `1 Tm Rugged Structural Screws Speedy lag bolt alternative with immense drawing power EA r E. 4 UberGradeTM 1 Zero Stripping, with 6 points of contact ° Code Approved for Structural Application Enlarges hole to reduce splitting Case Hardened Steel High Tensile, Torque and Low torque, smoother drive Shear Strength ClimatekTm Coating is AC257 Code No pre-drilling, Approved for use in Treated Lumber • faster penatration Equivalent Strength yet twice the Installation Speed of fraditronal Lag Screws or Lag_Bolts � , - 0 � , � • tern ❑r..J ffi 1 uikFoot—Product Guide Cutsheets:Bracket Cptions°Z'1Q1 5T8" � r i a 1 7 116., V 6:, 5 = -� 3;16" "t , X39 $ 3 P 7 €£, :? 4X R1 j3„ z a 5;16' 0 3/88" THRU ALL \/ 7/T±.0 10 X 82 �=.AR SIDE h 112" + .._ t 1 1 1 s = 3j4:, qqs � ` -- r r ' x 877-859-3947 EcoFasten Solar's All content protected under copyright.All rights reserved 10/09114 310 a _ EceFasten Solar products are protected by the!ollawing J.S.Patents:8,151 522 82 8,153 700 82 3 181 398 32 8,166,713 82 8,146,295 82 8.209.914 62 8,245,454 H2 8,272,174 92 8,225,557 H2 is p QuikFoot—Product Guide Ct,��h�..ts Bracket Options-L-1 02-6" 13132" �V r }t 1, im.111 Y-ikll € 31 �> N c pk m 45.00";--' ON + _ 90.00 R.0I 0 3I8"+.01 THR'JALL DETAIL A y "' 7;8`d+'tli X 82°, NEAR SIDE SCALE 2:1 877-859-3947 EcoFasten Solar'All con tent protected under copyright.All rights reserved 10109114 '�a s }� EcoFasten Solar products are protected by the following U.S.Patents 8,151,522 B2 8,153 700 B2 9.181,398 B2 8,166,713 82 8,146,299 82 8.209.914 82 8,245,454 B2 8,272,774 82 8,225.557 B2 z is QuikFoot—Product Guide Cut Sheets:Bracket Options- '-3-CSC � tt tl 4 I s TOP VIEW BOTTOM VIEW ID 3 1313 3 9 E of 0 5/16` T 1 1 f14" 8/8-16 1 N�Z 1 16"—', 3i`8-16 UNC v 1 1/16' 718"X 82 7y� 4T t: ee 877 -859-3947 EcoFasten Solar All content protected under copyright.All nghts reserved.10/09/14 3.8 R EcoFasten Solar products are protected by the following U.S.Patents 12 22 82 8,153,700 82 8.181.39a 62 8,166,713 62 8,14E,259 92 3.209.914 82 8,245,454 62 8,272,174 B2 8,225.557 62 t `t1 QuikFoot—Product Guide Cut Sheets.Bracket Options-SCL-1,01-3 z 46 SERRATIONS _ ,, t � "177 c r � k IyS $ 3� 3 � RI/I b, SB,F ................... 1 7(8` �....._. � s 1/}b"..... f —1 X14" �- "� —..... f 3 s ........._ 1 j RM5 y I 1 z# 8.010—� X R. I 60.60- 3V —.002 k - n C,U' 7/8"X 82° CA LE 3:1 lg A s s��t s .� y 8 7 8.,9-3947 EccFasten Selary All content protected under cepynght.All rights reserved.10109J1 3' 5,454 82 8 272,174 B2 8,225.557 82 EcoFasten Solar products are protected by the following U.S.Patents.8 151,522 B2 8 153,700 B2 8.181 398 B2 8,166,713 B2 8,146,"299 B2 8."209.914 B2 8.24 rt. �2°3 a > .405in±.010 10.? mm-!-0.25' f v N .......... jyr 9 V 70 lr t- �I� u 47.63mrn I —► 75in 05mm� } �ti v w' ^'a S 03 n C 877-859-3947 EcoFasten Solar All content protected under copyright.All rights reserved.10109/14 _ 3.6 EcoFastan Solar products are protected by the following U.S.Patents.8,157,522 B2 8,153,700K 3,181,398 B2 8,1ab 713 B2 8,146,2s9 B2 8.209.514 82 8245,454 62 8,272.174 ^< 72,174 02 8,225.557 B QuikFoot—Product Guide Cutsheets:Bracket Captions-Comp Slide tr r � s s .23!n Us.Gbmf71.� a 5.94mrn 521n �_ = b [13.OFmnn z SLOT FOR � x 5/16"HHCS 1.06in _ -- F 26.42mm I 1,00in r �`� 5 % 0.377*.000 THRU € t 4.00in 0.375-±.010 X 82' 101.60mm 877_859-3947 EcoPasten Solar''All content protected under ccpyright All rights reserved.10/09/14 -�-' Ec Pastan Solar products are protected by the following U.S.Patents.8,151,522 32 8,153,700. 82 9,181,398 62 8,166,713 62 8,146,295 02 8.209.914 82 8,245,454 82 8,272.174 82 8,225.557 82 QuikFoot—Product Guide Cutsheets: Bracket Options-F-131-A v at .... —,4 A 3 i 4 5i 4 E e y� 1t I 1 3x I 0 11� T H R VI CALL 0 /8'X82" N EAP ME ...` ° N } '11 IIIJIPF�� fir,F 0 s 8.,7-559-3947 EcoFasten Solar'All content protected under ccpynght All rights reserved 10109714 3.4 EcoPasten Solar products are protected by the follming US.Patents.8,151 522 B2 8 153 700 82 8.181.398 B2 8,166,713 62 8j4 29 98 2 8.209.914 B2 8 245,454 B2 8.:72,174 B2 8,225,557 B2 ----..�_—� F 41".3:-3E QuikFoot-Product Guide Cut Sheets:bracket Options-CP-S'J-Slotted IS, �gY 3 $e tAy t Yal 3 �1� ,1 0A u I i PRE I.iiv 3 s O .t,G w z 2. �. I. 3 , � ✓6 G R j 877-859-3947 Eco asten SM All content protected under copyright.All rights reserved.10109114 3.3 �a EcoFasten Solar products are protected W the following U.S.Patents.8 252,522 E2 8,1 MAW M 9 181.398 B2 I160,713 82 8 24 10 W 8.M 914 W$245,454 82 8 272,274 W 8,225,557 82 E,?a 1,r �31� pb4 R-1.1i a; QuikFoot—Product Guide Cast Sheets:QFL-812 1 R.38in [9.53mm] .032in [0.81 mm] IIMM i f � f E Y' A { d £ �> ji 12,00in 304.80mm s 3.00in Pq r� s� [7b.20mm] Is y ? F 8.00in [12.70mm t [203.20mm] FF t 877-859-3947 EccFasten Solar'All content protected under copyright.All rights reserved.10109/14 3.) 4 f a EcoFasten Solar products are protected by the following U.S.Patents 8.151,5:2 B2 8,153,706 82 3,181.398 82 8,166,1,13 82 8,14529u B2 8,209,914 B^<8.245,456 82 8,272174 32 8,225.557 62 T i V rt QuikFoot—Product Guide Cut Sheets:QF-AL-Base y 2X 0.33in [8.38mm 1 M' 'y t Y }} <3 t v E u � r k 1t 13 k 0i3 3 M [38.1Omm] i 3/8"-16 Stud r J £y. C- 9 5" F,' 3 QF-L . 1.75„ IN k 4 4 ' Wk S 7-859-3947 EcoPasten Solar"All content protected under copyright.All rights reserved.1009114 � 3.1 d �€' Ecol'asten Solar products are protected by the following U.S.Patenis.8.15',522 B2 8,153,700 B2 3.181,398 B2 8,166,713 B2$145,299 82 8.209.914 B2 8,245,454 82 8,272,17 4 22 8,225.557 B2 Dimensions P Typ.y< SBB 300 Ptus ;5BB400 Ptos SBB 600 Ptus A Height of unit wlinsu l anon inlmm 66.1/1679 71.711848 683/1735 0 Height of unit without insu:atia n in Inn m 63.3/1609 70.111781 65.711670 c Height of well for temp,sensor inlmm 46.4/1179 48.7/1738 46.911192 D Heig ht th er m o meter in/mm 41.1/1045 43.011093 41.5/1055 E Height spare part _in/mm 40.311025 41.01078 40.9/1040 F Height of well for temp.sensor _ trim. 21.91557 22.01560 23A1595 G Height in5p¢(till flange _ in/mm 14.4,'365 14.41367 15.91405 N Height cold walerfeed iOrnm 2.9173 2.6165 2.0/50 I Height solar cold feed in/mm 11.01280 11.11282 10.91277 1_Heigh Solar hot return in/mm 34.01865 34.1/867 33.9/862 K Height healerhot hot le r re t u rn iorn. 38.41975 44.5!1130 42.9/1089 L Heigh[ci rcul at ion port in/mm 52.7/1339 63.011600 512/1453 2 M Height cold boderfeed in/mm 52.7/1339 63.011600 57.2/1453 = V N Overall height in/mm 67.0811704 73.7411873 69.2911760 0 Width without thermal Insulation in/mm 21.65/550 23062/600 29.52/750 P Width with thermal nsulatian inlmm 27.55/700 29.521750 36.221920 Y 17 12 1 10 11 2 Pressure Drop Curve for SBB Tanks 3 20 ._._. ._.._. ._._ _..... ___. _... ____. ____. ......... _. SGB 4ro BofWm HX 10 a 16 ..... ... __ .... _. 9 14 z _ ___ a - 588 300 Bottam NX $ m12 .... .._ ..... __ ... . ...... ...... ......._.�� ......... _.... ... SBB 3a0 Top HX 6 w. r 7 N r 10 __ ___ ____. ..._._... .......... ... __._... __..... _._ __._ _..188600 Top HX - - - i Sacrificial anode indicator a ___ 2 Thermometer 3 Well for temperature sensor(boiler) 6 -.........-. - -- --- ----- ---- --- - ✓sea 66a Bottom HX 4 Well for temperature sensor lsolar) 5 Clean-out port 6 Foam insulation 2 ✓ p Cold water inlet 8 a Heat exchanger ports o _._ ....._........_., - __,_.._........._.. lower loop(solar) a 2 , 6 s 10 12 < 9 Lower exchanger coil(solar) Flow Rate(GPM) 10 Heat exchanger ports 'g upper loop(boiler) 11 Upper exchanger coil(boiler) 12 Hot water outlet E Specification Tank shall be constructed of steel with porcelain enamel coating on all surfaces in contact with DHW.Tank shall be insulated with ure- thane foam insulation 2.95 in. (70 mm.)thick to R-21 with an ABS outer casing cover. Standby heat loss shall be between 1.9 and 2.9 kWh (6,500-10,000 BTU) per 24 hours.Tank shall be delivered wrapped in plastic on a one-way pallet.Tank shall have been pressure tested to 217 PSA/15 bar and the maximum operating pressure shall be 150 PSI/10 bar.Tank shall be ETL certified in USA and Canada to IAS U.S. - Requirements for Indirect Fired Water Heaters For Use With External Heat Source. No 1-91, Dated June 6, 1992.Tank shall be equipped _ with welded steel plain-ended pipe heat exchangers, hot water corrosion protection via special enamel coating and magnesium sacri- ficial anode,three immersion sleeves for housing of temperature probe and thermometer, circulation socket, inspection/cleaning port on with cover. - Engineer/Architect...... ... _ _. Date _ Job Name/Customer . ._ .................. ......... . ...... __...... . Location .._.__ ..................._ ........ Contractor . _ ..__..___ Representative Qty Volume SBB model _ .............. L ELTRON 17 West St.,W.Hatfield,MA 01088 800.582.8423 413.247.3380'fax 413.247.3369'info @stiebel-eltron-usa.com?www.stiebei-eltron-usa.com STIEBELELTRON Simply ENGINEERING SPECIFICATION SHEET e SBB Indirectly Fired Water Heater Tanks Features Heavy gauge steel with porcelain enamel coating Superb quality with long service life • n Fitted with one or two large heat exchangers u Sacrificial anode rod Up to 3" R-21 urethane foam insulation for low standby heat loss u Large clean out port for ease of maintenance 10-year warranty ' I • Left to right SBB 300 SBB 400 SBB 600 Plus ModeLs & Specifications SBB 300 S SBB 400 S SBB 300 Plus SBB 400 Plus SBB 600 Plus Item Number 221219 221222 187873 187874 187875 Contents Storage Capacity 82.5 gal/3051 110.8 gal/4111 80.6 gal 3051 108.6 gal/4111 162.9 gal/617 1 Volume of heat exchanger,top NA NA 1.9 gal/7.31 2.2 gal/8.21 2.5 gal 19.61 Volume of heat exchanger,bottom 2.7 gal/10.11 2.9 gal/11.31 2.7 gal/10.1 1 2.9 gal!11.3 1 3.5 gal/13.2 1 Pressure Working pressure 150 PSI/10 bar 150 PSI/10 bar 150 PSI/10 bar 150 PSI 110 bar 150 PSI/to bar Tested to pressure 217 PSI/15 bar 217 PSI/15 bar 217 PSI/15 bar 217 PSI 115 bar 217 PSI/15 bar Max.pressure of upper loop NA NA 150 PSI/10 bar 150 PSI/to bar 150 PSI/to bar z 3 Temperature Max.temperature of lower loop 266 IF/130°C 266 IF 1130°C 266 IF/130°C 266 IF/130°C 266 IF/130°C Max temperature of upper loop NA NA 266 IF/130°C 266 IF/130°C 266 IF 1130°C E Heat exchanger = Surface area heat exchanger top NA NA 1,705 sq.in 11.1 m2 2,015 sq.in 11.3 m2 2.945 sq.in/1.9 m2 _ Surface area heat exchanger bottom 2,325 sq.in!1.5 m2 2,635 sq.in 11.7 m2 2,325 sq.in/1.5 m2 2,635 sq.in/1.7 m2 3,875 sq.in/2.5 m2 Output rating heat exchanger top NA NA 111,000 BTU/hr/32 kW 128,000 BTU/hr/33 kW 182,000 BTU/hr/53 kW Output rating heat exchanger bottom 150,000 BTU/hr 144 kW 164,000 BTU/hr/48 kW 150,000 BTU/hr/44 kW 164,000 BTU/hr/48 kW 242,000 BTU/hr/71 kW Weights Tank weight empty 292 lb/133 kg 371 Ib/169 kg 339 lb/154 kg 412 1/187 kg 544 lb 1247 kg - Tank weight full 988 Lb 1448 kg 1304 lb 1591 kg 1051 lb/477 kg 136216 1618 kg 195516!887 kg Other Standby losses in 24 hours 6500 BTU 11.9 kWh 7500 BTU/2.2 kWh 6500 BTU/1.9 kWh 7500 BTU/2.2 kWh 10000 BTU/2.9 kWh Cold/hot water connection 1"copper pipe via adapter - Dimensions - Height with insulation 66 3/32 in/1,679 mm 72 11/16 in 11,848 mm 66 3/32 in/1,679 mm 72 11/16 in/1,848 mm 68 5/16 in/1,735 mm Width with insulation 27 9/16 in 1700 mm 291/2 in 1750 mm 27 9/16 in/700 mm 291/2 in/750 mm 361/4 in/920 mm Width of insulation 3 in/75 mm 3 in/75 mm 3 in/75 mm 3 in/75 mm 3 11/32 in/85 mm *Insulation is partially removable to reduce width to 31.5"for clearance purposes SBB tanks are ETL certified in US Land Canada to IAS U.S.Requirements ISO 9001 C I uS for Indirect Fired Water Heaters CERTIFIED = m° For Use With External Heat Source. Intertek No 1-91,Dated June 6,1992 STIEBEL ELTRON 17 West St.,W.Hatfield,MA 01088'`800.582.8423 413.247.3380 fax 413.247.3369 info @stiebel-eltron-usa.com www.stiebei-eltron-usa.com Sol 27 Premium: Proven Technology Meets Modern Design i Technical SAP IS0 9001 IS0 9806 .,. ;,.1 C US CERTIFIED COMPLIANT SOL 27 Premium S SOL 27 Premium IN Item no. 230016 230017 Type Vertical Horizontal Height 85.5"/2171 mm 46.1"/1171 mm Width 46,1"/1171 mm 85.5"12171 mm' Depth 3.8"/96 mm 3.8"/96 mm Weight 88.21bs/40 kg 89.3 lbs/40.5 kg Casing material Aluminum,corrosion resistant Aluminum,corrosion resistant Glass cover ESG ESG Glass thickness 0.125"/3.2 mm 0.125"/3.2 mm Thermal insulation thickness i 2"/50 mm 2'150 mm Thermal insulation material Mineral wool,low outgassing,WLG 040 Mineral wool,low outgassing,WLG 040 Collector connection 22 mm plug-in connector 22 mm plug-in connector Max.idle temperature <410°F/<210°c <410°F/<210% Min.operating pressure 50.75 psi/0.35 MPa 50.75 psi/0.35,MPa Max.permissible pressure 87 psi/0.6 MPa 87 psi/0.6 MPa Pressure drop at 300 A 0.51 psi 0.0035 MPa 0.51 psi 10.0035.Mpa Test pressure 247 psi/1.7 MPa 247 psi%1.7 MPa Test medium: Water(at the factory) Water(at the factory) Heat transfer medium DowFrost DowFrost Fill level,heat transfer medium: 0.4 gal/1.51 0.48 gal/1.83 1 Nominal volume flow 13-80 gal/hr/50-300 1/hr 13-80 gal/hr/50-300 1/hr Angle of inclination 200-850 200-850 Total area 27.34 ft,/2.54 m- 27.34 W/2.54 m� Aperture area 25.73 ft/2.39 m� 25.73 W/2.39 rn' Absorber area 25.62 fv/2.38 m' 25.62 fv/2.38 m Absorber Aluminum,highly selective coating,' Aluminum,highly selective coating, copper pipes,laser welded copper pipes,laser welded Gasket EPDM EPDM Conversion factor qo 0.82 0.83 Effective heat transfer coefficient al 3.46 w i(m K) 3.46 w i(m K) Effective heat transfer coefficient a2 0.0153 W/(m*) 0.0153 w/im,K'l Absorption level a 95%,±2% 95%,±2% Emission level a 5%,t1% 5%,t1% Collector yield >525/kWh/(ml p.a.) >525/kwh/(m�p.a.) Performance subject to global solar radiation levels,installation conditions,heat transfer medium temperature and system characteristics. STIEBEL ELTRON FAMILY OF ENERGY SAVING PRODUCTS HOT WATER SOLUTIONS RENEWABLE ENERGY Efficient tankless �w t!I V �I Highest ENERGY STAR electric water heaters DHC Tempra rated air-source heat Point-of-use Whole House Accelera-300 pump water heater Tankless Tankless Heat Pump Water Heater Distributed by: 5tiebel Eltron's plant in Holzminden,Germany, 5tiebel Eltron has been a world leader STIEBEL ELTRON in the development of advanced water 17 West Street heating technology for over 80 years. West Hatfield,MA 01088 Our pursuit of engineering excellence and high-quality manufacturing results rou FREE 800.582.8423 in products fulfilling the highest expec PHONE 413.247.3380 tations of performance and reliability. FAx413.247.3369 advan our continuous pra::ess of eilan eewit and otife.cgi:al info @stiebel-eltron-usa.eom 31 an..�ment soar i-.ati.ns may 'ia�g without nntir� They are...5imply the best. y c:' Pn rted an recycl l rh.lurine fr:epap r.aM soy-La e.d inks. "47 5,2014 www.stiebei-eltron-usa.com Simple and Proven Effective: STIEBEL ELTRON Solar Thermal. Heat & Hot Water C cl�-S OG-100 CERTIFIED GSA F 378 ISO 9001 ISO 980b � CERTIFIED COMPLIANT Precision o-ring plumbing connections make installation quick and easy. No tools are'',required. See Advantages include: Architecturally compatible The SOL 27 Premium A highly effective design Stiebel Eltron uses only is available in both vertical (SOL 27 Premium S) the most durable materials. The SOL 27 Premium and horizontal (SOL 27 Premium W) configurations is the culmination of over 40 years of experience in to accommodate a variety of architectural and solar thermal manufacturing. The SOL 27 Premium's engineering needs. Its low 3" profile makes it 10 year warranty is a testament to the confidence visually less obtrusive. we have in our products. A lasting and reliable investment in energy Installation time is minimized The large panel savings The SOL 27 Premium is a highly efficient size and the availability of a full complement of solar thermal collector. The net absorber surface custom designed mounting accessories minimize of over 25 square feet helps result in a maximum installation costs. The plumbing connection from output of 31,300 btu/day per panel (SRCC clear day collector to collector does not require the use of rating). The SOL 27 Premium also offers features tools. such as a highly selective absorber coating, low-iron, tempered solar glazing, and very effective insulation around the absorber plate. The internal fluid tubes are copper and the absorber plate is aluminum. Tax Credits and other incentives Please consult our website. The SOL 27 Premium is eligible for a 30%federal tax credit on the total rns product cerrred by me Stiebel Eltron Clear Da cost of materials and labor,with no upper limit,as well as any state 501erRa,eoaCe,td,eton 17 West Street y •iSVt�� no FseC.ls?i9 Cieene�e Roed West Hatfield,MA 01088 Rating in or local tax or rebate incentives that may apply. Federal tax credit is X32„ 8;5.2 Model No.:Sol 27 Premium W Category C ww.-ier-rauny crg Gross Area 2.55 m=(27.4 ft� 9.2 kWh/day not available for systems that heat swimming pools or hot tubs. SRCCDoN .ntOG-100 Serial Number: 31.3 KBtu/day System must be installed in primary residence. Proven Technology Meets Modern Design The SOL 27 Premium is ideal for: ,SAVE WATER MONEY a Residential domestic hot water a Radiant in-floor space heating Commercial water heating 5 � a f . B: 9 5- �s s z The SOS 27 Premium's SOL 27 Premium w modern appearance seamlessLy integrates with any architecture. X M SOL 27 Premium S a w` rr S � N s z 9 Versatile mounting rack kits make every installation easy! STIEBEL ELTRON Simply the Best HARVEST THE POWER OF THE SUN ! The new SOL 27 Premium solar collector—the result of over 40 years of solar f thermal engineering. �kx a r, y' . ✓ i a h ,g K ) HIGHLY SELECTIVE COATING ) LOW PROFILE AT 3" THICKNESS SOL 27 Premium ) LOW IRON TEMPERED SOLAR GLASS FLAT PLATE SOLAR COLLECTOR ) ALUMINUM ABSORBER WITH COPPER FLUID TUBES ) DURABLE CORROSION RESISTANT ALUMINUM FRAME ) CUSTOM MOUNTING HARDWARE AVAILABLE ".'�. ISO 9001 ISO 9804 CERTIFIED COMPLIANT C �us ) 10-YEAR WARRANTY GA>378 �00.58268 1 Vreeland Design Associates An integrative approach to design, engineering and site planning Date: November 12, 2015 Re: James Roberts, 96 Straw Ave, Florence, MA: Structural assessment and reinforcement detail of existing roof to support proposed PV and Thermal solar panel arrays. On 10/22/15 we conducted a site visit and investigated the existing roof framing in the area of the proposed PV and thermal solar panel arrays. The 2-story, 28'x 44' hipped roof house was constructed in 1927. The rafters are full dimension 2x6 at 24" on-center spanning 13'-8" with a 7/12 roof slope. The hip rafters are full dimension 2x8 and span approximately 19'. Full dimension 2x6 attic floor joists, at 16" on-center, spanning 14', are attached to full dimension 2x4 exterior wall studs and supported on a bearing wall in the middle and running the 44' length of the house. There is a similar bearing wall on the first floor as well. A 2x4 plate is attached to the top of the wall studs and the 2x6 rafters are attached to the plate. Three (3) thermal solar panels, at 91 Ibs each with fluid, will be mounted on the west side of the south roof and 13 PV solar panels, at 37 Ibs each, are proposed on the remaining area of the 44' long south roof. Due to the hip roof layout the length of the ridge is approximately 16'. The south full length 2x6 rafters need to be reinforced by installing a 2x4 kneewall located 2'-6" in from the exterior wall to reduce the span of the rafters. The vertical 2x4 can be attached to the sides of the rafter with 2 —21W TimberLok screws and toe screwed to a 2 - 2x4 plate that has been attached to the top of the floor joists. The 2x4 plate needs to be doubled because the joist are 16" o.c. and the rafters are 24" o.c. The south hip rafters will need to be reinforced as shown below: Z Z?"C. R10(6 i 1 3-Zxloxo' -� BEAM-ME SCACW~.D ? ��a SIMPSOn1 SXEWE� Jo1ST'14PIOWE N �84,p 1 }7J SUt��LZIOZ NA`R EFT SKFWE� %z- FtN6E.!2. LISE 1LCoE Q V(AC..QQALE,GVT T'O f1T 1WM i o 2,)(4 KNE£hlqu '-1 t 1_0, -7 d, 441-0 �1HOFAtgS 11`!-b 9 70 S1 of 2 ng N1P �O DAVID A. G Zr VREEUWD 2-2X4 POST 3-Zn�OX10 U CIVIL y 3-zx>jciEa+e _ S�Am, No.4$317 S1Mp50�1 Sl�LZIO-2 Ib° WpQ�(. �FCISTE���Rlfff $KCWEO NAN6cQ '"F 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland @verizon.net Fax: (413) 624-3282 The Commonwealth of Massachusetts Department of Industrial Accidents W Office of Investigations 1 Congress Street, Suite 100 Boston, MA 02114-2017 www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Spartan Solar Address: 10 Charles St. City/State/Zip: Greenfield, MA 01301 Phone #:413-768-0095 Are you an employer? Check the appropriate box: Type of project(required): 1.❑ I am a employer with 4. I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. F] New construction 2.0 I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working or me in an capacity. employees and have workers' g y p �'• 9. E] Building addition [No workers' comp. insurance comp. insurance.* required.] 5. We are a corporation and its 10.0 Electrical repairs or additions officers have exercised their 11. Plumbing repairs or additions 3.❑ I am a homeowner doing all work ❑ g p myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no 13.❑ Other Solar Hot Water System employees. [No workers' comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins. Lic. #: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify ukqer the pains d penalties of perjury that the information provided above is true and correct. Si ature: Date: 10 k� �o15 Phone#: 413-768065 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 9c� `owJ � _ The debris will be transported by: The debris will be received by: (ter A K Building permit number: Name of Permit Applicant (`�z�w� ���a Date Signat re of Per it Applicant SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor:: (� Not Applicable ❑ Name of License Holder: `�� �G4v\ t-1 lC�(G A,�i i Ls— b a7 li�(�3 9 License Number S e O a -2-0� Addr Expiration bate Signatu Telephone 9. Registered Home Improvement Contractor: Not Applicable ❑ Company Narn6 Registrati n Num er (0 '� '3 (-2- Address 7 r? ExplIM101 I Date Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.162,§26C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg.Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO Q DON'T KNOW YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW 0 YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO iAJ DONT KNOW 0 YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,exc vation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO V IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [OI Decks (C:J Siding(0] Other[I9a] Brief Description of Proposed - 1 1 Work: �r,� Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h Type of construction i. Is construction within 100 ft. of wetlands? Yes No Is construction within 100 yr. floodplain Yes No I. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank. City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT as Owner of the subject propert hereby a onze �•- y behalf, in all tter tiv o d by this build it appli�tion. Am, 10 10/28/2015 i atu f Owner Date as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name Signature of Owner/Agent Date -_ C of Northampton Status of Permit: Department use only DEC — E ?(j B ilding Department Curb Cut/Driveway Permit 12 Main Street Sewer/Septic Availability Room 100 Water/Well Availability Nef#hampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office (Q S+v-wJ 4 e-�,`�� Map Lot Unit Zone Overlay District Elm St District CS District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Re rd: e(Print Current Mailing _ g4 I Sic, Telephone Signa re 2.2 t razed A ent: Name(Pri n Current Mailing Address: Signature Telephone C_JION ESTIMA6D CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building (a)Building Permit Fee 2. Electrical (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5.Fire Protection & Total= +2+3+4+5 1 C ( ) Check Number This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date File# BP-2016-0739 APPLICANT/CONTACT PERSON SPARTAN SOLAR ADDRESS/PHONE 10 CHARLES ST GREENFIELD01301 (413)768-0095 PROPERTY LOCATION 96 STRAW AVE MAP 17D PARCEL 050 001 ZONE URB(IOO)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee-Paid I TEM New Construction Non Structural interior renovations Addition to Existin¢ Accessory Structure Building Plans Included: _ Owner/Statement or License 107869 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO TION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project_ Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management D o ' D y e of Building Of 1cial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 96 STIl Aw AVE BP-2016-0739 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17D-050 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL e.142A) Cateuory: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-0739 Project# JS-2016-001238 Est. Cost: $11250.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SPARTAN SOLAR 107869 Lot Size(ss . ft.): 7971.48 Owner: ROBERTS JAMES D zoning. URB(100)/ Applicant: SPARTAN SOLAR AT. 96 STRAW AVE Applicant Address: Phone: Insurance: 10 CHARLES ST (413) 768-0095 GREENFIELDMA01301 ISSUED ON.121712015 0:00:00 TO PERFORM THE FOLLOWING WORK.-REPLACE SOLAR HOT WATER SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: iiIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 12/7/2015 0:00:00 $75.00 212 Main Street,Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner