17C-071 (7)�I i l =ee Single Phase Inverters for North America so I a r 30130A-is SE3800A_US.1 SE5000A-I,S SE600A- S s o a r - S'7600A-US SE10000A-US!SE1140CA-LIS SE300OA-US SE380OA-US I SE5000A-US '..SE600OA-US!.SE760OA-US!. SE10000A-US SE11400A-US OUTPUT SolarEdge Single Phase Inverters _ - Nominal AC Power Output 30CC 38CG SOGO 6000 7600 9980 @ 2J8V ;.1400 VA lOCCO @240V 5400 la 208V 1.080C @ 208V For North America Max.AC Power Output 33Ct7 47Si) 5450 Cd240V 6060 8350 1095-0 @)240V 72000 VA AC Output Voltage Min.-Nom.-Max rl 183-208-229 Vac ✓ ✓ SE300OA-US!' SE380OA-US! SE500OA-US! SE600OA-US/ AC Output VoltageNlin-Nom-Maxi" 217.-240 264 Vac J ✓ J ✓ ✓ ✓ J SE760OA-US. E10000A-US;' SE1140OA-US AC Frequency Mir,-Nom.-Max.'`) 5143-60-60.5(with HI country setting 57-60-60.51 Hz 24 @ 208V - _ z8�y 208V Max.Continuous Output Current _2 5 i6 25 32 47.S A s" 21 @ 240V 42 @ 240V Threshold Ut!ty Monitoring,Islanding protection,Country Cont•gurable'hresholds Yes Yes es -- _ tG." INPU,7um CPowcrr,rCl _.... 4 ,C : ,..,C 6.50 _ ..CC .C�_., _.,.;00 .,3.,., ... W 8 n # ��q a �� Transformer less,Ung ourded Yes i c 6 n Max.input Voltage 500 Vdc Nom.DC Input Voltage 325 @ 208V/35C(a]240V Vdc °ajio � 7 Max ?npft Current(n 9 S 1`13 16.5 @ V 208V 18 23 33 @ 208V 34.S Adc 5.5 @ 240 3C.S @ 240V ,. - i Max.Input Short Circuit Current 45 ' Adc �- Reverse-Pa arty Protection Yes Ground Fault Imlation detection 600k,,Sensitivity Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 _ 98 97.5 C. 2UHV 9?@ 208V CEC Weighted Efficiency 97.5 98 98 @ 140V 975 9'1.5 @ 24CV 97.5 9'•5 Nighttime Power Consumption <2 5 <4 W ADD17TCNALPEATLTRES - - Su pore orrrnun cation intertaces RS48S,RS232,Fthertet,llgF3ee(optional) Revenue Grade Data,ANSI 012.1 Optionali'I ,z y g rapid shutdown kit is installed(`' Raped Shutdown 201469012 _ - Functionality enabled when SolarEd era- ,. STANDARD COMPLIANCE r - _. -- safety UL17 41,UL16 9B,UL1998, C SA 22.2 Grid Connection Standards IEEE1547 Emissions FCC partly class B INSTALLATION SPECIFICATIONS AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/83 AWG DC input conduit size/#of strings{ 3/4"minimum/1 2 strings/ z : AWG range 3/4"minimum/1-2 strings/16-6 AWG 14-6 AWG -, x Dimensions with Safety Switch 30.5 x 12.5 x 10 5/ in/ 30.5 x72.5 x 7.2//75 x 315 x 184 ff1xWxD) 775 x 315 x 260 mm _ Weight with Safety Switch ',, 51.2/23.2 54.7/24.7 88.4/40.1 Ib/kg Natural x convection Cooling Natural Convection and internal Fans(user replaceable) fan(user ',.. The best chol for�fOIc�CEE�g{'t'11Abled systerns replaceable) ' Noise <2S <50 dBA W integrated arc fault protection(Type 11 for NEC 2011690.11 compliiance ' Min.-Max.Operating temperature /.0 -13 to+140/-25 to+60(-40 to+60 version availablel'1) °E Superior efficiency(98 )' Range Protection Rating NEMA 3R = Small,lightweight and easy to install on provided bracket rpr other re g onal settings please contact SolarEdge support Built-in zi A even-current source may SE ,,d;the 5000 NR2(f II limit OW nput current t0 the values stated. � Built-fn module-level monitoring Isi Revenue grade inverter P/N:SExxxxA USOOONNR2(for 7600W nverter:SE7600A-U5002NNR2). Internet connection through Ethernet or Wireless °f Rapid shutdown E P/N:SE1000NNU4 1. ) Isi 40 vers on mn SExxxx:SE1000 RSD (for 7600W inverter:SE]600A-U5002NN U4 . Outdoor and indoor installation Fixed voltage inverter,I]I conversion only Pre-assembled Safety Switch for faster installation Optional-revenue grade data,ANSI C12.1 src . .HS 1 _... 1N1, RA _ ,..`.1 C1 ,IV'd, it;YlPAL ' 1HEt7. I_' L'�."C RA l:+`ttiA✓.Jt7lUfCG��°LS r.�ni.r wlannli THE Tesnamount 1. T o Mono Multi Solutions DIMENSIONS OF PV MODULE EiEC'"R'3C,AL DATA:,"STC anit'rrsrn Peak Power Watts-PM„x(Wp) 250 255 260 265 941 - Power Output Toteranae-PM':Ax{%) 0-+3 Maximum Power Voltage-VMP(V) 30.3 30.5 30-6 30.8 I o nrx*rom o THE rina U t BOX Maximum Power Current IMPP IAJ $.27 8.37 8:50 8.61 NpMEPtg1E J Open Circuit Voltage-Vac(V) 38.0 38.1 38.2 38.3 NsTew"cnoiF i Short Circuit Current ksc IA) $.74 8.88" 4:00 4,10 Module Efficiency n°,(%) 15.3 15.6 15.9 16.2 MODULE STC Irradiance 1000 W/m'.Cell Temperature 25°C,Air Mass AMI.5 according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 W/m'according to EN 60904-I. 0 � I o ELECTRICAL DATA F;li : Maximum Power-PraxlWp) 186 190 193 197 ELL Maximum Power Voltage-VmiP(V) 28.0 28.1 28.3 28.4 !gyp f/+�{�V *� 1 k* _ Maximum Power Current-IMP-(A) 6.65 6.74 6.84 6.93 MULTICR STALLINE MODULE ,. aeucnou«wruc"orr PD05.18 A ? Open Circuit Voltage(V)-Voa(VJ 35.2 35!3 35.4 35.5 tie u e a.� �+t t�� FRAME r:ow+""orr WITH TRINAMOUNT FRAME Short Circuit Current(A)-Isc(A) 7.10 7.17 7.27 7.35 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed I m/s. I 250-26,51W 812 180 Back View ,,t EF'n;qN*^A DATA POWER OUTPUT RANGE Solarcelis Multicrystalline 156 x 156 mm(6 inches) Fast and simple to install through drop in mounfing solution i 1 I Cell orientation 60 cells(6 x lo) Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 Inches) ..... ... _. .-_. _.._ --__ ii: Weight 19,6 kg(43.12 lbs) • Gloss 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass MAXIMUM EfFIC1ENCY Backsheet white n-n - Frame Black Anodized Aluminium Alloy Good aesthetics for residential applications J-Box IP 65 or IP 67 rated ■ -' Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), A/ 1200 mm i4721nches) T t-3...URb`ES OF PV PRC}C?Gt.v=t.aOVv j POSITIVE POWER TOLERANCE Connector H4Amphenoi °w r°°ow/m' \ -_. __ Fire Type UL 1703 Type 2 for Solar City Highly reliable due to stringent quality control son - - J' T ti _._ _ �cl 7E&1�iRA?->}Rr .,., t ,...t.�'.rsS v x1��4 ..z€.., - .. m _- .. a r t r g _ Nominal Operating Cell -* Operational Temperature 40-+g5°C 4w .L, 400wlm= 44°C( 2°C) Temperature(NOCT) Maximum System 1000V f7C(IEC) ' :°oW/_ ,,"N Temperature Coefficient of PMax -.0.41%/°C Voltage 1000V DC(UL}: 100 - - - -- Temperature Coefficient of V- ow -0.32%/°C Max Series Fuse Rating 15A 0 to z° so ao s° TettiperatureCoefficient rlflsc •0.05%/°C Certified to withstand challenging environmental conditions 9ol"aM WARRANTY <<£RTIPIC:zT3C> 10 year Product Workmanship Warranty r i 1 711 7, c 25 year Linear Power Warranty SR, (Please refer to product warranty for details) Q LIVED LINEAR PERFORMANCE WARRANTY 5 PACKAGING CONFICUI TGh nr--11 Ins -wra 10 Year Product Warranty-2 Year Linear Power Warranty Modules per box:26 pieces w Ti incl Sotor Tifed Un -"'--- ---------- Modules per AO'container:728 pieces � 3100% d fF F c 6 voiu N fPE) 90% 7 frFp Scrar'r Eraser r, a CAUTION'.READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. IoM PATj a 2015 Tr Ta Solar Lmited-AII nghts reserved.Speor-ons ncluded in this dotasheet are subject to N elm. solar` (�80% �, ,� change w thous notice. as .,. . Years >r 5 10 15 20 K 25 ,..- ...3 paa14PN" _...o._ ..� .. TSM Mono Multi Solutions IMEFISI farts .y,MODUL'r 'n't'`n' Peak Power Watts-PN...,(wp) 245 250 255 260 941 --- Power Output 7oleronce-Prxax 0-+3 Maximum Power Vo(tage-V.,(V) 29.9 30.3 30.5 30.6 THE Trinalw%1^1 o u I I t n a Maximum PowerGurrent-l-P(Al 8.20 8.27 8.37 8.50 ure I 6, Open Circuit Voltage-Voc(V) 37.8 38.0 38.1 38.2 ZITIA GeOLf Short Circuit Current-Isc(A) 8.75 8.79 8.88 9M € Module Efficiency DA)(%) 15.0 15.3 15.6 15.9 MODE STC-Irrad ante 1000 W/m'.Cell Temperature 25°C.A r Mass AMI-5 according to EN 60904-3. Typical efPc'ency reduction of 4,5%at 200 W/m1 according to EN 60904-I. O b Ib I O 60 E.L■ Maximum Power-P. (Wp) 182 186 190 193 eTA L att1II��1 Maximum Power Voltage-V­(V) 27.6 28,0 28.1 28.3 MULTICRYSTALLINE MODULE arvc HOLE -' Maximum Power Current-l-,(A) 6.59 6.65 6.74 6.84 t caouu WITH TRINAMOUNT FRAME oAN HOLE - -- Open Clrcuil Voltage(V)•Voc IV) 35.3 35.2 35.3 35.4 Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 727 - I _ NOCT:Irrad lance of 800 W/m'.Ambient Temperature 20°C,W nd Speed I nr �!'� PDOS.18 Biz�- - lso-' Back View POWER OUTPUT RANGE t Solar cells Mulficrystalline 156 x 156 mm(6 inches) y jy Fast and simple to install through drop in nnal�ntin solution � ..cell orientation 60 cells(6 x 10) m (elk) 1 ♦ # _ Module dimensions 1650 x 992 x 40 m(64.95 x 39.05 x 1.57 inches) ;(j °v Weight 21.3 kg(47.0 ibs( MAXIMUM EFFICIENCY Glass 3.2 mm(0,13 inches),High Transmission AR Coated Tempered Glass A-A Backsheet White Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Tnnamount Groove Li 0�+ v GJRti>5 OF Pb MODULE{?�€ ti`d) Cab) IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 10x - --- ---- 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE 90 -100ow/m- __ e„ Fire Rating Type 2 800W/m' Highly reliable due to stringent quality control ''-- d > T ,R F,6TURE R,-' t �4 NGS MAXIMUM GS °p -400W/m 14 T Ti i (� �` z'^ 20oW/m' Nominal Operating Cell 44°C(+2°C) Operational Temperature 40-+85°C t Temperature(NOCT) - t 1 11 -tc s - `-1 Maximum System 100OV DC(lEC) r -- __-- --- ___-- ---- --- --- ---- D"'.. - Temperature Coefficient of PrnAx -0.41%/°C Voltage 1000V DC(UL) _._._...._.. 1« .:i .. .,,. ,..-, _... Ow 10.40 20.w 30.°- 40.1° _- votaeelVl Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A r d r ,xr r fir r :J s Temperature Coefficient of ho 0.05%/°C ertifted to withstand challenging environmental conditions 0 x L,t_.�:bs WARRANT' 10 year Product Workmanship Warranty 25 year linear Power Warranty ,J s,lo _ (Please refer to product warranty for details) a CERTIF CA'7ION r =„ LINEAR PERFORMANCE WARRANTY sP1 PACKAGz NG CONFlGilRITION _____ ___.__- ___..___---___--- __-- w ._ ...._. .._....___.._..__ ( Year Product Warranty' 5 1`Eq!'Linear tr4Wei`Y+6QCrsnty._, p i usr® 5 Xl T ga Solar Limited Modules Per 40 container:728Pieces uAN - -- -- -- o ..•: -.' . m 90% fine" ... CAUTION.READ SAiFETY- AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT ® 02014 Tana Solar Lmited.All rghts reseved Spec ficto ncuded n this dataheef a.e ublet to Trin-asolar 80%ftm*i66 l change without notice 5 dr En 9 y Years S 10 IS 20 25 - ti�OMRq elm pepppptx0v i I I ' • sola r _ ® r solar=@e SolarEdge Power Optimizer Module Add-On for North America P300 i P350 / P400 SolarEd a Power Optimizer 9 P P300.._... .__P350 __. P400 Module Add-On For North America (for 6®aeII PV (for 72-cell PV (for B6-cell PV modules) modules) modules) INPUT P300 / P350 / P400 ® Rated Input DC Power!`! 300 350 400 W Absolute Maximum Input Voltage(V o c at owest temperature) 48 60 80 Vdc �r t ' MPPT Operating Range 8-48 8-60 8-80 Vdc „ 3 e s _Maximum ShortC- cu't Current llsc 10 Adc µ • ' � Maximum DC Input Current 12.5 - Adc Maximum Efficiency _ 99.5 % Weighted Efhc ency 988 O rvoltage Category _ _ _ .... - OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum O tput Current t5 Adc Maximum Output Voltage. - 60 _Vdc _.. ' aP �s • OUTPUT DURING STANDBY(POW_ER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF). y _ __- Safety Output Voltage per Gower Optimizer Vdc STANDARD COMPLIANCE - s EMC _ - FCC Par115 Class B,IEC61000 6 2,IEC61000 6 3 Safety !EC62109 I(class h safety),UI.1741 s ' RaHS yes � e INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc ..� ,-. Dimensions(W xLx H) 141x 217x 40.5/s S5 x8.34x 7.59 mm/in i Weight(including cables) 950/2,1 gr/Ib =� Input Connector MC4/Amphenoi/Tyro Output Wire Type/Connector Doubie Insulated,Amphenoi Output Wire Length 0.95/3.0 1.2/3.9 m/ft Operating T ra empeture Range -40-+85/-40-+185 'C/°P , Prote,ton Rating IP65/NEMA4 '.. Relative Humidity 0-7.00 PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V V power op'tIErii$ation at the module-level Minimum String Length(Power Optimizers) 8 _...._ 10 _.B Up to 25%more energy Maximum String:ength(Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 - 12750 W ®Superior efficiency(99.5%) Parallel Strings of Different Lengths or Orientations ', yes — Mitigates all types of module mismatch tosses,from manufacturing tolerance to partial shading -,Flexible system design for maximum)space utilization - Fast installation with a single bolt —..Next generation maintenance with module-level monitoring: �I Module-level voltage Shutdown for installer and firefighter safety %t�SOlarClty ®pSolar Next-Level PV Mounting Technology ^SoiarCity ®pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs ¢^Ilia Up-roof ' (.evetinp Foor� a < � a�� fill lilh,I Zep Comp"ibte w swdut., `•, 2Cp.Orooae� 's Ft-f Ati b t i GOMPA Description �� PV mounting solution for composition shingle roofs OOMPAt1 Works with all Zep Compatible Modules • Auto bonding UL-listed hardware creates structual and electrical bond Zep System has a UL 1703 Class"A"Fire Rating when installed using U` LISTED modules from any manufacturer certified as"Type 1"or"Type 2" Comp Mount Interlock Leveling Foot Part No.850-1382 Part No.850-1388 Part No.850-1397 Listed to UL 2582& Listed to UL 2703 Listed to UL 2703 Specifications Mounting Block to UL 2703 Designed for pitched roofs • Installs in portrait and landscape orientations „] • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt,Grip,End Caps DC Wire Clip • Attachment method UL listed to UL 2582 for Wind Driven Rain Part No.850-1172 Part Nos.500-0113, Part No.850-1448 Listed to UL 2703 and 850-1421,850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of Zep Solar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 1 of 2 02 27 15 ZS for Comp Shingle Cutsheet Rev 04.pdf Page: 2 of 2 WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: .• • • .• • • -_ Code: 11VARNIN :_ ;'_WARNING '.. Code: NEC 690.31.G.3 ELI=C`CRIG SHOCK HAZARD ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS '•I THE DC CONDUCTORS OF THIS ' .- • • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN INVERTERIS LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND PHOTOVOLTAIC DC ••- UNGROUNDED IN THE OPEN POSITION MAY BE ENERGIZED NEC DISCONNECT -- .• Label Location: Label • • (POI ' . INTERCONNECTION Code: MAXIMUM POWER- A WARNING: ELECTRIC SHOCK POINT CURRENT(Imp) _ ••. 690.17.4; 690.54 HAZARD. DO NOT TOUCH MAXIMUM POWER- 690.53 TERMINALS.TERMINALS ON POINT VOLTAGE{Vmp)- BOTH THE LINE AND LOAD SIDE ENEW01 (SYSTVoEI) POSITION. FOR SERVICE SHORT-CIRCUIT A OE-ENERGIZE BOTH SOURCE CURRENT{Isc)- AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT - MAXIMUM AC V Label Location: OPERATING VOLTAGE WARNING ••- ELECTRIC SHOCK HAZARD • IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED Label L• • CONDUCTORS MAY BE CAUTI�N • UNGROUNDED AND ENERGIZED DUAL POWER SOURCE Per ••- SECOND SOURCE IS 690.64.13.4 PHOTOVOLTAIC SYSTEM Label • • WARNING Code: Label ELECTRICAL SHOCK HAZARD �t'1UT1 ON • • DO NQT TOUCH TERMINALS ••I . -• TERMINALS ON BOTH LINE AND Per Code: LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM 690.64.13.4 1N THE OPEN POSITION CIRCUIT IS BACKFED DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED:TO SUNLIGHT Label • • WARNING '• Per Code: INVERTER OUTPUT Label • • CONNECTION ' PHOTOVOLTAIC AC -• DO NOT RELOCATE Disconnect DISCONNECT Per Code: THISODEVCERRENT Conduit NEC 6•I (CB): Combiner :• Distribution Panel Disconnect (IC): Int • Conduit Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC A -•I) (LC): Load Center OPERATING CURRENT Per ••- MAXIMUM AC bPERATING VOLTAGE V NEC 690.54 -• Point of • • 3055 Clearview Way :a r • • • r •� San Mateo,CA 94402 • • a • �� • • .•- - r • • ' 0638-1028 F:(650)638-1029 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO TWO (N) GROUND Panel Number:NoLabel Inv 1: DC Ungrounded INV I -(1)SOLAREDGE # SE3800A-US00OSNR2 LABEL: A -(14)TRINA SOLAR ## TSM-260PDO5.18 GEN #168572 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:59906379 Inverter; 380OW, 24OV, 97.574 w/Unifed Disco and ZB,RGM,AFCI PV Module; 25OW, 236.9W PTC, 40MM, Black Frame, H4, ZEP, 1000V ELEC 1136 MR Overhead Service Entrance INV 2 Voc: 38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL E; 150A/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER-HAMMER 150A/2P Disconnect 2 SOLAREDGE (E) LOADS SE380OA-USOOOSNR2 A L1 zaov L2 20A/2P N 1------------------------------------- EGG DC. DC, - -GEC N DC- MP 1,MP 2: 1x14 B I , I N _J c EGC!GEC Z [J I I I I I I TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE I I I I I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP I (1)MURRAY/MP2 0 PV BACKFEED BREAKER (1)CUTLER-HAMMER DG221UR8 (14)SOLAREDGE AP3DD-2NA4AZS Breaker, 20A/2P, 2 Spaces Disconnect; 30A,pp24OVac, Non-Fusible, NEMA 3R AC PowerBox Optimizer, 30OW, H4, DC to DC, ZEP DC 'L'-578'dxRB1' Copper -(')Grroound�'NAeutrol Kit DOA General Duty(DG) nd (1)AWG/6, Solid Bare Copper -(1)Ground Rod; 5/8" x 8', Copper [(N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE I (1)AWG/10, THWN-2, Block (2)AWG 110 PV Wire 60OV, Blade Voc* =500 VDC Isc =15 ADC O (1)AWG/10, THWN-2, Red O (1)AWG/6 Solid Bare Copper EGC Vmp =350 VDC Imp=10.26 ADC LLL LLL(1)AWG 110, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1 Conduct Kit; 3 4' EMT . . . . .. .-0)AWG#8,.THWM-2,.Green . .EGc/GEC.-(1)Ponduit,Kit;.3/4",EMT . . . . . . . . . ). . . . . ... ./. . . . . .. .. .. . . .. . . . . . . . . . . . . . . .. . . . . . . . . . . . . i l I CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-0101515 00 PREMISE OWNER: DESCRIPTION: DESK;H: CONTAINED SHALL NOT USED FOR THE WORDEN, GARY WORDEN RESIDENCE Chris Doan -;; y BENEFIT OF ANYONE ECCE PT SOLARCITY INC., MOUNTING SYSTEM: �.,, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp ount Type C 91 CHESTNUT ST 3.64 KW PV ARRAY ;SolarCit PART TO OTHERS OUTSIDE THE RECIPIENTS P ORGANIZATION, EXCEPT IN CONNECTION NTH MODULES: FLORENCE, MA 01062 THE SALE AND USE OF THE RESPECTIVE (14) TRINA SOLAR # TSM-260PDO5.18 24 St. Martin Drive,Building 2 Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Marlborough, MA 01752 PERMISSION OF SOLARCITY INC. "SOLA 4135843241 PV 4 10 23 2015 T. (650)638-'026 F: (85 w 638-1029 SOLAREDGE SE3800A—USOOOSNR2 THREE LINE DIAGRAM / / ( >- -pn(765-2469) www.sdaralty.aam S1 10'-2" � OF 6 (E) LBW �� SIDE VIEW OF MPS NTS s Nom MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 24" STAGGERED PORTRAIT 48" 18" RAFTER 2x6 @ 16" OC ARRAY AZI 281 PITCH 24 STORIES: 2 !STANIPED & , , C.J. 2x6 @16" OC Comp Shingle "IRS. S 1 PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER ` & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) C(2)FSEAL PILOT HOLE WITH 10'-2" ZEP COMP MOUNT C - - OLYURETHANE SEALANT. 6' (E) LBW ZEP FLASHING C (3) (3) INSERT FLASHING. SIDE VIEW OF MP2 NTS (E) COMP. SHINGLE I (1) (4) PLACE MOUNT. B (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES LANDSCAPE 64" 24" STAGGERED WITH SEALING WASHER (6) IN LEVELING FOOT WITH BOLT & WASHERS. PORTRAIT 48" 18" (2-1/2" EMBED, MIN) RAFTER 2x6 @ 16" OC ROOF AZI 101 PITCH 24 STORIES: 2 (E) RAFTER ARRAY AZI 101 PITCH 24 1 STAN DOFF C.J. 2x6 @16" OC Comp Shingle CON J B-0101515 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN ,q8 NUMBER: CONTAINED SHALL NOT BE USED FOR THE WORDEN, GARY WORDEN RESIDENCE Chris Doan ,.� „SOIt'Clty. BENEFIT OF ANYONE EXCEPT SOLARgTY INC., MOUNTING SYSTEM: � �� (, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 91 CHESTNUT ST 3.64 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (14) TRINA SOLAR # TSM-260PDO5.18 PAGE NAME SHEET: REV: DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: L• (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE380OA—USOOOSNR2 4135843241 STRUCTURAL VIEWS PV 3 10/23/2015 1 (888)—SOL—CITY(765-2489) www.solarcity.com PITCH: 24 ARRAY PITCH:24 MP2 AZIMUTH: 101 ARRAY AZIMUTH: 101 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 24 ARRAY PITCH:24 MP3 AZIMUTH: 191 ARRAY AZIMUTH: 191 MATERIAL:Comp Shingle STORY: 2 Stories c (E) DRIVEWAY B � 3 v A � N :.d Front Of House LEGEND (E) UTILITY METER & WARNING LABEL Ins INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS DEDICATED PV SYSTEM METER W ILLIAMA. STANDOFF LOCATIONS ' CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR AC GATE/FENCE HEAT PRODUCING VENTS ARE RED r, Digitally signed by INTERIOR EQUIPMENT IS DASHED William A. SITE PLAN Eldredge Jr. N a,' P & SIGNED Date:2015.10.24 Scale: 1/8" = 1' E W FOR STRUCTUFIAL ONLY 15:02:11 -04'00' 0 1' 8' 16' s CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OMNER: DESCRIPTION. DESIGN. CONTAINED SHALL NOT BE USED FOR THE J B-0101515 00 -4N"� ■ WORDEN, GARY WORDEN RESIDENCE Chris Doan ;;So�arCity BENEFIT IT BE DISCLOSED IN SOLARCITY OR IN MOUNTING SYSTEM:ou 91 CHESTNUT ST 3.64 KW PV ARRAY ''"_ PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: FLORENCE, MA 01062 THE SALE AND USE OF THE RESPECTIVE (14) TRINA SOLAR # TSM-260PDO5.18 I 24 St.MwUn Dr1w,Building 2, Unit 11 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 61VTRTER PAGE NAME ' DAIS T: (650)638-1028 : (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE3800A—USOOOSNR2 4135843241 SITE PLAN PV 2 10/23/2015 (888)-SCI-CITY(765-2489) www.sdarcitycom ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A �/ / AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. ~ BLDG BUILDING BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. City of Northampton I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Building Department Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Plan Review Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER 212 Main Street kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC ijhrthampton, MA 01060 LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET JPV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Cutsheets Attached GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. �! 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Northampton REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) J B-0101515 00 RISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: Chris Doan i,solarCity.CONTAINED SHALL NOT BE USED FOR THE WORDEN, GARY WORDEN RESIDENCE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �o1 NOR SHALL IT BE DISCLOSED IN WIOLE OR IN Comp Mount Type C 91 CHESTNUT ST 3.64 KW PV ARRAY PART To OTHERS OUTSIDE THE RECIPIENTS MODULES FLORENCE MA 01062 ORGANIZATION, EXCEPT IN CONNECTION WITH 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (14) TRINA SOLAR # TSM-260PDO5.18 PAS NAB. SHEET: REV. DATE: Marlborough, MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN MVER7ER: T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE380OA—USOOOSNR2 4135843241 COVER SHEET PV 1 10/23/2015 (868)-S0L-aTY(765-2489) www.edaraityaam CALCULATION OF DESIGN WIND LOADS - MP1 &MP2 Mounting Plane Information Roofing Material Comp Roof PV System Type SolarCity SleekMountTM Spanning Vents No Standoff Attachment Hardware) Comp Mount Type C Roof Slope 240 Rafter Spacing 16"O.C. Framing Type/ Direction Y-Y Rafters Purlin Spacing X-X Purlins Only NA Tile Reveal Tile Roofs Only NA Tile Attachment System Tile Roofs Only NA Standing Seam/Trap Spacing SM Seam Only NA Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 90 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable Roof Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Wind Pressure Calculation Coefficients Wind Pressure Exposure KZ 0.95 Table 6-3 Topographic Factor KA 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh I= 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 16.7 psf Wind Pressure Ext. Pressure Coefficient U ) GC -0.88 Fig.6-11B/C/D-14A/B Ext. Pressure Coefficient Down G D.,," 0.45 Fig.6-11B/C/D-14A/B Design Wind Pressure p p = qh(GC ) Equation 6-22 Wind Pressure Up RUM -14.6 psf Wind Pressure Down 11)(downi 1 10.0 psf ALLOWABLE STANDOFF SPACINGS X-Direction Y-Direction Max Allowable Standoff Spacinq Landscape 64" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 17 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -225 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 44.9% X-Direction Y-Direction Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 18" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3.0 psf Net Wind Uplift at Standoff T-actual -280 Ibs Uplift Capacity of Standoff T-allow 500 Ibs Standoff Demand/Capacity DCR 56.0% STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK- MP1 &MP2 Member Properties Summary MP1 &MP2 Horizontal Member Spans Rafter Pro perties Overhang 0.49 ft Actual W 1.50" Roof Sstem Pro rties San 1 10.20 ft Actual D 5.50" Number of Spans w/o Overhang) 1 Span 2 Nominal Yes Roofing Material Comp Roof Span 3 A 8.25,in.^2 Re-Roof No Span 4 S. 7.56 in A3 Plywood Sheathing Yes Sean 5 I 20.80 in A4 Board Sheathing None Total Rake Span 11.70 ft TL Defl'n Limit 120 Vaulted Ceiling No PV 1 Start 4.00 ft Wood Species SPF Ceiling Finish 112"Gypsum Board PV 1 End 10.67 ft Wood Grade #2 Rafter Slope 240 PV 2 Start Fb 875 psi Rafter Spacing 16"O.C. PV 2 End F„ 135 psi Top Lat Bracing Full PV 3 Start E 1400000 psi Bot Lat Bracing At Supports PV 3 End Emin 510000 psi Member Loading mary Roof Pitch 6/12 Initial Pitch Ad'ust Non-PV Areas PV Areas Roof Dead Load DL 10.0 psf x 1.09 10.9 psf 10.9 psf PV Dead Load PV-DL 3.0 psf x 1.09 3.3 psf Roof Live Load RLL 20.0 psf x 0.93 18.5 psf Live/Snow Load LL SL1,2 40.0 psf x 0.7 1 x 0.7 28.0 psf 28.0 psf Total Load(Governing LC TL 1 38.9 Psf 42.2 psf Notes: 1. ps=Cs*pf; Cs-roof,Cs-pv per ASCE 7[Figure 7-2] 2. pf=0.7(Q(Ct)(IS)p9; Ce=0.9,Ct=1.1,IS=1.0 Member Design Summa (per NDS Governing Load Comb I CD CL + CL - CF Cr D+ S 1 1.15 1.00 1 0.64 1.3 1.15 tuber Analysis Results Summary Governing Analysis Max Demand C Location Capacity DCR Result Bending + Stress 1134 psi 5.7 ft 1504 psi 0.75 Pass Version#52.6-TBD SolarCity HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES Landscape Hardware-Landscape Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi&MP2 64" 24" 39" NA Staggered 44.9% Portrait Hardware-Portrait Modules'Standoff Specifications Hardware X-X Spacing X-X Cantilever Y-Y Spacing Y-Y Cantilever Configuration Uplift DCR MPi&MP2 48" 18" 65" NA Staggered 56.0% Structure Mounting Plane Framing Qualification Results Type Spacing Pitch Member Evaluation Results MPi&MP2 Stick Frame @ 16 in.O.C. 240 Member Analysis OK Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information gathered on site.The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC. 1055 Glearview Way Swi PAateo, GA 04402 T(650)638 IpV8 (888)SOL-CITY F(650)638-1029 solarcity.corm Version#52.6-TBD < < SolarCit y October 24,2015 aDREDGE it. 3 No 5=7 RE: CERTIFICATION LETTER Project/Job# 0101515 Project Address: Worden Residence Chestnut St Florence, MA 01062 Ilk Design Criteria: -Applicable Codes = MA Res. Code, 8th Edition,ASCE 7-05,and 2005 NDS - Risk Category = II -Wind Speed = 90 mph, Exposure Category C -Ground Snow Load =40 psf - MP1 &MP2: Roof DL= 10 psf, Roof LL/SL =28 psf(Non-PV Areas), Roof LL/SL= 28 psf(PV Areas) Note: Per IBC 1613.1; Seismic check is not required because Ss = 0.22424 < 0.4g and Seismic Design Category(SDC) = B < D To Whom It May Concern, A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity. Structural evaluation was based on site observations and the design criteria listed above. Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions adopted/referenced above. This review relies on the roof's structural system having been originally designed and constructed in accordance with the building code requirements and having been maintained to be in good condition. Additionally,I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the manufacturer's specifications and to meet and/or exceed all requirements set forth by the ASCE 7 standards for loading. The PV assembly hardware specifications are contained in the plans submitted for approval. Additionally a summary of the structural review is provided in the results summary tables on the following page. Digitally signed by William A.Eldredge Jr. Date:2015.10.24 William A. Eldredge, P.E. 15:01:44-04'00' Professional Engineer T: 888.765.2489 x58636 email: weldredge @solarcity.com 3055 Clearview Way San Mateo.CA 94=102 T(6501 638 1428 (888)S,01,-CITY r(6 50)638-1029 s larcity.coni DocuSign Envelope ID:FC9DB422-385E-43CC-BC4F-CA961F94689E 23. NOTICE OF RIGHT TO CANCEL. I have read this Power Purchase Agreement and the Exhibits in YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR their entirety and I acknowledge that I have received a TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE complete copy of this Power Purchase Agreement. DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT 1,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN Customer's Name:Gary Worden EXPLANATION OF THIS RIGHT. 1:EXE cuSigned by: 24. ADDITIONAL RIGHTS TO CANCEL. Signature. �Or IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 23,YOU MAY ALSO CANCEL Date: 10/1}2015 THIS PPA AT NO COST AT ANY TIME PRIOR TO COMMENCEMENT OF CONSTRUCTION ON YOUR HOME. 25. Pricing The pricing in this PPA is valid for 30 days after 10/1/2015. Customer's Name: If you don't sign this PPA and return it to us on or prior to 30 days after 10/1/2015,SolarCity reserves the right to Signature: reject this PPA unless you agree to our then current pricing. Date: Power Purchase Agreement SolarCity AM approved Signature: __..�_�� �� Lyndon Rive, CEO Date: 10/1/2015 Ni'm DocuSign Envelope ID:FC9DB422-385E-43CC-BC4F-CA961F94689E SolarCity I PPa Customer Name and Address installation Location Gary Warden 91 Chestnut St 10/1/2015 91 Chestnut St Florence, MA 01062 Northampton,MA 01062 Here are the key terms of your Power Purchase Agreement $0 12 ,v00c 20yrs System installation cast Electricity rats kWh Agreeme r T•.++�yyrr L�tN In?tial here nitiai he_" r_ The SolarCity Promise G� •We guarantee that if you sell your Home,the buyer will qualify to assume your Agreement. _......,.. ___ Initial mere •We warrant all of our roofing work. E s •We restore your roof at the end of the Agreement. •We warrant,insure, maintain and repair the System. -_._. nitial here •We fix or pay for any damage we may cause to your property. •We provide 24/1 web enabled monitoring at no additional cost. «The rate you pay us will never increase by more than 2.90%per year. •The pricing in this Agreement is valid for 30 days after 10/1/201.5. •You are free to cancel any time prior to construction at no charge. Your SolarCity Power Purchase Agreement Details Your Choices at the End of the Initial Options for System Purchase: Amount due at contract signing Term: •At certain times, as specified in $0 •SolarCity will remove the System at no the Agreement,you may Est.amount due at installation cost to you. purchase the System. $0 •You can upgrade to a new System with •These options apply during the 20 the latest solar technology under a new year term of our Agreement and Est,amount due at building inspection contract, not beyond that term. $0 •You may purchase the System from Est.first year production SolarCity for its fair market value as 3,589 kWh specified in the Agreement. •You may renew this Agreement for up to ten (10)years in two(2)five(5)year increments. 3055 Clear view Way, San Mateo, CA 94402 1 888.7651489 1 solarcl y.c m 1165237 Power Purchase Agreement,version 9.0 3,August 24,2015 SAPC/SETA Compliant. Contractors License MA HIC 168572/LL-1136MR Document generated on 10111201.5 Copyright 2008 2015 SolarCity Corporation,All Rights Reserved 'qua` r CERTIFICATE OF LIABILITY INSURANCE n0m`I2 °°""'"' 0811712015 0811712015 01 s THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(€es)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain Policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such andorsement(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES NAME:PHONE T FAX 345 CAtIFORNIA STREET,SUITE 13D0 fAtC.flaxt} liArc Mot CALIFORNIA LICENSE NO.0437153 E DRESS; SAN FRANCISCO CA 94104 _ . Attw Shannon Scott 415743.8334 INSUpER�s�AFFORDING COVERAGE 998301_STNT)GAWUE-15-16 INSURER A:Zurich American insurance Company 16535 INSURED INSURER B:NIA 'NIA SolarCity Cmporaiion _+_ 3055 Clearview Way wsyRER c,NIA... ... .......... NIA.... San Mateo,CA 94402 INSURER U:American Zurich insurance Company 140142 iNSURERE: INSURER F COVERAGES CERTIFICATE NUMBER: SEA-002713836.08 REVISION NUMBER:4 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAIL]CLAIMS. INSR -------..—..__._...... A66L SUER ---..._—.�PNOUCYEFF POLICY EXP�. T TYPE OF INSURANCE POLICY NUMBER MMIDDIYYYY LIMITS A l X 'COMMERCIAL GENERAL LIABILITY tGL00192016-00 0910112015 !09,1112016 EACHOCCURRENCE S 3,ODD,000 CLAWS-MADE !x... OCCUR 1 - DAMAGE TO RENTED rice), s 3,000,000 X SIR$250,000 i MEO EXP(Any one person) S 5.000 PERSONAL&ADV INJURY 5 3,000,000 rE�'L AGGREGATE LIMIT APPLIES PER PRO- GENERAL AGGREGATE 5 fi 000,000 POLICY� JECT L )LOC FPRODUCTS-COMPIOP AGG S 6000,000 - ..,...... OTHER. is A AUTOMOSILE LIABILITY -BAP0182017.00 091012015 !09/01/2016 COMBINED SINGLE LIMIT j S 5,000,000_ K i Ea ecclden .. .. ...... ANY AUTO j I BODILY INJURY(Per person) $ _X ALL OVYtFE❑ .X� SCHEDULED 00DILY INJURY iPer acudertl S 'AUT05 AUTOS ,_.. ........ AUTOS NED PROPERTY DAMAGE X HIRED AUTOS X ALy7tlg I i � S jeer acadenl ... COMRCOLL DED. S $5000 UMBRELLA LIAa 4 OCCUR i EACH OCCURRENCE S EXCESS LfA6 ICLAIMS-MAM AGGREGATE }$ DED ii RETENTIONS I I S D WORKERS COMPENSATION C0182014-DO(AOS) 09MIM15 09110112016 X (PER I OTH- ANDEMPLOYERS'LIA81LrfY I ..i.$TATUTE.. ER A ANY PROPRtETORiPARTNERrEXECUTIVS YNN NIA 'WCD182015- 00(MA) 09 112015 0910112016 E.L.EACH ACCIDENT t$ 1,ODD,D00 OFFICERIMEMSER EXCLUDED? € - - - - ----— IMandatery in NH) WC DEDUCTIBLE:$500,DOO E.L.DISEASE-F1,EMPLOYE S 1,000,000 if yyes,describe under --- -- ..- - - - -- DESCRIPTION OFOPERATIONS bofaw ! EL DISEASE•POLICY LIMIT $ 1,000,000 l f DESCRIPTION OF OPERATIONS!LOCATIONS I VEHICLES IACORO 101,Additional Remarks Schedule,may be attached K more space Is required) Evidence of insurance. CERTIFICATE HOLDER CANCELLATION SalarCily Corporation SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 3055 Clenrew Way THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN San Mateo,CA 89402 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services I Charles Marmolejo 0 1988-20'14 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD -r Tile Commonwealth of Massachusetts Department of IntlustrialAccirlents �'(` 4f ee of Investigadous 1 Congress Street,Smite 100 Boston,AAA 02114-2017 wlvts mass gop1dia Workers'Compensation Insurance Affidavit:BuildersfContractors/Electriciansiplumbers Applicant Information .Please Print Le ibl Name(Business/Organizationlindividual): ` OLARCITY CORP Address:3055 CLEARVIEW WAY City/State/Zip:SAN MATEO,CA 94402 Phone#:886-765-2489 Are you an employer?Check the appropriate box: Type of project(required): I.[( I am a employer with 5000 4. E] I am a general contractor and I employees(Full and/or part-tune), have hired the sub-contractors G. New construction 2.[] I am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have g. t)cmoluion working for me in any capacity. employees and have workers' Building audition 9. [] tNo workers'comp.insurance comp.insurance. t required.) S. n We are a corporation and its 10.❑Electrical repairs or additions 3.[1 1 am a homeowner doing ail work officers have exercised their I I.[]Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12_[]Roof repairs insurance required.]t c. 152,§I(4),and we have no SOLAR/PV employees.[No workers' 13.E Other comp.insurance required.] 11 A Any spplleant that chechx box#1 must also fill out tine seefian bciow showing their workers'compeasation policy iaforalation. t Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a nmw affidavit indicating such. tGontractors that check this box must attached on additional sheet shaving the name of the sub-wnlraaors and slate whether or not those entitics have employees. If the sub-contractors have employees,they must provide their worlxrs'comp,policy ntuuber, I irin an employer that Is providing workers'compensation Fnsurn►►cc for my em IO.VeM. Below is the polkp aMI job 8110 lnfornraolon. Insurance Company Name, Zurich American Insurance Company Policy It or Self-ins.Lie,M WC0182014-00 Expiration gate: 09/01/2016 Job Site Address: I� �� >V City/stxtc/Zip=— Attach a copy of the workers'compensation policy declaration pale(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MOL c. 152 can lead to flit imposition of criminal penalties of a fore up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the ILIA for insurance coverage verification. I rlo hereby certo ponder Ike pales asul penalties of perjury Thai Noe 1prarmatlon provided b i•true and correct. l?n Slattil'e: Phone ft-, Official vise only. Do viol write in this area,to be completed bj,city or town official. City or Town: PerrnittLicense# Issuing Authority(circle one): 1.Board of Health 2.Building Department I Cloy/Tow"Clerk 4.Electrical inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#; SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder:SOLARCITY/CRAIG ELLS 107663 License Number 604 SILVER ST AGAWAM MA 01001 8/29/17 Address Expiration Date 1 L 978-875-1698 Signature Telephone 9.Renistered Home Improvement Contractor: Not Applicable ❑ SOLARCITY CORP/VICTORIA JUNCK 168572 Company Name Registration Number 604 SILVER ST AGAWAM MA 01001 03/08/2017 Address Expiration Date Telephone 978-215-2367 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner'Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the buildine permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition Replacement Windows Alteration(s) Roofing Or Doors Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding[ I Other F771 Brief Description of Proposed Work: Install solar electric 12anels to roof of existing home,to be interconnected with home's electrical system. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes _No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing,complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Gary Worden as Owner of the subject property hereby authorize SOLARCITY to act on my behalf, in all matters relative to work authorized by this building permit application. 10/26/2015 ignature of Owner Date SOLARCITY CORPNICTORIA JUNCK as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. SOLARCITY CORPNICTO IA JUNCK Print Name 1�)A PY 10/26/2015 Signature of-Owner/Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This columgto be filled in by Building Department Lot Size t Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Department use only City of Northampton Status of Perms Building Department Curb Cut/Dnveway Permit 212 Main Street Sewer/Septic Availability `NO`NSPO�oNS Room 100 WaterMlell Availability ofeU �oN Mp orthampton, MA 01060 Two Sets of Structural Plans t phone 413-587-1240 Fax 413-587-1272 PlotlSite Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 91 Chestnut St Map Lot Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Gary Worden 91 Chestnut St, Florence,MA 01062 Name(Print) Current Mailing Address: 413-584-3241 Telephone Signature 2.2 Authorized Agent: SolarCity CorpNictoria Junck 604 Silver St Agawam MA 01001 Name(Print) Current Mailing Address: 978-215-2367 8?&-- 5 2-- J- P 2w& Signa re Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building 3,000 (a) Building Permit Fee 2. Electrical 6,000 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total = 0 +2+3+4+5) 9,000 Check Number This Section For Official Use Only Building ermit Number: Date g Issued: Signature: Building Commissioner/Inspector of Buildings Date File#BP-2016-0583 APPLICANT/CONTACT PERSON SOLARCITY CORP ADDRESS/PHONE 604 SILVER ST AGAWAMO1001 (888)765-2489(2358) PROPERTY LOCATION 91 CHESTNUT ST MAP 17C PARCEL 071 001 ZONE URB000)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APP_LICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: INSTALL ROOF MOUNTED 3.64 SOLAR ARRAY New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 107663 3 sets of Plans/Plot Plan THE F%LOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF ATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay .�72�5 Si re of Bui i O ic' Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 91 CHESTNUT ST BP-2016-0583 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17C-071 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Buildinq DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR PANELS BUILDING PERMIT Permit# BP-2016-0583 Project# JS-2016-000970 Est. Cost: $9000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: SOLARCITY CORP 107663 Lot Size(sq. ft.): 10541.52 Owner: WORDEN GARY C&SANDRA A Zoning: URB(100)/ Applicant. SOLARCITY CORP AT. 91 CHESTNUT ST Applicant Address: Phone: Insurance: 604 SILVER ST (888) 765-2489 (2358) Workers Compensation AGAWAMMA01001 ISSUED ON.1012812015 0:00:00 TO PERFORM THE FOLLOWING WORK.INSTALL ROOF MOUNTED 3.64 SOLAR ARRAY POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 10/28/2015 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner