Loading...
17D-081 (5) Primary Structure (house): - Two Story with a walk out basement and accessory apartment less than 900 square foot. - Maintains the character of the neighborhood with GABLE roof and an (8) on [12] roof pitch. - The house will be oriented towards SOLAR SOUTH to maximize passive solar gain. - The house's roof PEAK will be less than 30' and sub-ordinate to the 2-story house at 3 Garfield Ave. Accessory Structure (garage): - One-story accessory structure (garage) will be oriented about 15° EAST of SOLAR SOUTH: • To facilitate car access to the garage door from the street. • To increase morning active solar gain. - The garage will also feature a GABLE roof, in a possible SALTBOX configuration, with the roof slope determined by the optimal solar azimuth, between (8) and (10) on [12]. P M .. '�. " >s § terms✓ a+i Figure 2. View From Street. S3 4' 10 S4 R1 15' � ,.� 5 15' 4 15' F1 10' 4 S2 S1 Primary Structure setback Accessory Structure setback FIGURE 1. NORTHAMPTON CODE URB USES ALLOWED Uses Allowed By Right: • Single-,two-,three-family dwellings • Attached(to a single-family)accessory dwelling unit not to exceed 900 square feet gross living area. See§350-10.10.Same setback as for principal structures. • Home business up to 25 visits per week as defined in§350-2.1 • Zero lot line single-family;see§350-10.14 • Preexisting nonconforming uses(may trigger ZBA permit) • Accessory uses to residential: Tag sales:temporary sales of personal and household articles e s nuna s(§350--T • Accessory structures, detached (but no larger than 1,000 ftz of lot coverage or 3% of lot area, whichever is greater,unless it is used for agricultural purposes).See also§350-6.7. Setbacks: Front:20 feet Side:4 feet Rear:4 feet • Family day care(registration w/Building Commissioner required) • Cemetery • Temporary event as defined in §350-2.1 • Municipal facility;facilities for essential services • Agriculture, horticulture, floriculture, noncommercial forestry, the growing of all vegetables and a temporary(not to exceed erection or use for a period of four months in any one year)greenhouse or stand for retail sale of agricultural or farm products raised primarily on the same premises • Rooftop solar hot water and photovoltaic • Accessory solar photovoltaic(PV)ground-mounted on a parcel with any building/use,provided that the PV is sized to generate no more than 100%or 8 KW of the annual projected electric use of the non-PV building/use.Same setbacks as for detached accessory structures. • Solar photovoltaic of any size,ground-mounted over any legal parking lot or driveway Site Plan Approval Required for the Following: • Any construction(other than for a single-family home)greater than 2,000 square feet • Townhouses with six or fewer units • Educational use: nonprofit,dormitories, any religious use,day care, school-aged child-care program (MGL c. 28A, § 9) and historical association or society and nonprofit museum (may include the residence of a caretaker) • Reuse of historic educational or religious building(s) for any residential use, live/work space, or office;provided,however,that no more than 20%of the floor space of the building(s) shall be used for medical, banking or any offices where a primary function is to provide services to retail customers or individuals.All such uses approved under this provision shall be within the footprint of existing building(s) and may only be approved contingent upon protection of all historically contributing portions of the building with an historic preservation restriction granted to the City of Northampton in a form acceptable to the Planning Board, with input from the Historical Commission, as preserving the key character-defining features visible from the road (and not necessarily meeting federal or state preservation standards for the entire building). The existing building may be expanded to accommodate elevators and stairwells.Portions of the building that are not part of the original architecture of the building and which do not contribute to the historical or architectural significance of the building as determined by the Planning Board,with input from the Historical Commission,may be demolished. • Cluster development.See below for lot layout standards and§350-10.5 for other required criteria. • Parking off-site and combined parking.See§§350-8.5 and 350-8.7. 350 Attachment 7:4 09-01-2014 ZONING BOARD � DECISION City of Northampton Date:April 1, 2004 Ordinances. The permit includes subdivision approval for the extension of Garfield Avenue to create a three-lot cluster that will result in creation of six new affordable housing units on Lots 2 and 3 and one new market rate unit on Lot 1. The approval provides for a reduction in dimensional requirements for the new lots as well as approval for reduction in required frontage for 155 Chestnut Street(Map 1D 17C-66). The Board granted the following exemptions and waivers as part of the Comprehensive Permit's provision of six affordable units out of a total of eight units: 1.Reduction in minimum radius of road centerfine(250'to 235+-7 for a street§7:01(9)of the Northampton Subdivision Rules. 2.Reduction in right-of-way width.Providing 40'instead of required 60'in order to match the existing right-of-way width. 3.Reduction in "hammerhead"length(66'to 40'to match right-of-way). 4.Reduction in frontage for Lot 1 from 70'to 25'to allow reduction in overall length of street and right of way. 5.Reduction of frontage for Lot 3 from 85'to 70'to reduce road infrastructure. 6.Reduction in legal frontage for 155 Chestnut Street(Map ID 17C-66;Plan Book 115 Page 52 lot 1)from 75'to 50:Frontage to be transferred from Garfield Avenue to Chestnut Street. 7.Waiver for all city permits related to the curb cuts for Lots 1,Z,and 3. Two curb cuts approved for Lots 2 and 3 and one approved for Lot 1,maximum 1 allowed. 8. Waiver from providing full traffic study. A summary of traffic impacts was provided. 9.As shown on the approved plan sheet L1,side setback on Lot 3 is reduced from 15'to 12'to accommodate the side entry. The Findings of the Zoning Board of Appeals were based on public comments,recommendations from the Northampton Planning Board and Northampton Department of Public Works. Northampton Police and Fire Departments were consulted and had no concerns about the proposed development The Zoning Board of Appeals determined: A. The requested use includes provision for surface water drainage,sound and sight buffers and preservation of views,light,and air. A tree buffer will be provided along the boundary of Lot 3. Surface water drainage will improve water quality and quantity flowing off site; and B. The requested use will promote the convenience and safety of vehicular and pedestrian movement within the site and on adjacent streets,minimize traffic impacts on the streets and roads in the area. Consideration of the location of driveway openings in relation to traffic and adjacent streets,access by emergency vehicles,the arrangement of parking and loading spaces,and provisions for persons with disabilities has been made. The project includes creation of a sidewalk along one side fo the road extension and a hammerhead for emergency vehicle accessfturnaround. Driveway openings will be located on all three lots and will not negatively impact traffic function on the dead-end street;and C. The requested use will promote a harmonious relationship of structures and open spaces to the natural landscape,existing buildings and other community assets in the area.A majority(4+acres)of the site will be permanently protected as open space to be owned by the Northampton Conservation Commission,including permanent protection of the capped landfill. Public access to the open space will be provided through an easement across Lot 3. All development will be outside the wetland buffer zones;and D. The requested use will not overload,and will mitigate adverse impacts on,the City's resources including the effect on the City's water supply and distribution system,sanitary and storm sewage collection and treatment systems,fire protection,streets and schools. Stormwater will be mitigated on site. There is adequate capacity in the private sewer line to which this project will connect.;and E. The requested use bears a positive relationship to the public convenience or welfare. The use will not unduly impair the integrity of character of the district or adjoining zones,nor be detrimental to the health,morals,or general welfare. The use shall be in harmony with the general purpose and intent of the Ordinance. The project for four singel family homes in a cluster provides units that will be consistent with the rhythm and the character of the neighborhood a long Garfield Avenue;and F. The requested use will promote City planning objectives to the extent possible and will not adversely effect those objectives,as defined in City master or study plans adopted under M.G.L. Chapter 41,Section 81-C and D. Cluster in-rill development as recommeneded within the City's Vision 2020 document provides new residential units while permanently perserving open space. COULD NOT DEROGATE BECAUSE: FILING DEADLINE: MAILING DATE: HEARING CONTINUED DATE: DECISION DRAFT BY: APPEAL DATE: 12/11/2003 1213112003 211212004 4/8/2004 REFERRALS IN DATE: HEARING DEADLINE DATE: HEARING CLOSE DATE: FINAL SIGNING BY: APPEAL DEADLINE: 1212412003 11812004 312512004 41512004 412112004 FIRST ADVERTISING DATE: HEARING DATE: VOTING DATE: DECISION DATE: 1212512003 11812004 312512004 41112004 SECOND ADVERTISING DATE: HEARING TIME: VOTING DEADLINE: DECISION DEADLINE: 11112004 5:30 PM 1 312412004 41712004 MEMBERS PRESENT: VOTE: Malcolm Smith votes to Grant David Bloomberg votes to Grant Sara Northrup votes to Grant GeoTMS®2004 Des Lauriers Municipal Solutions,inc. -L� ZONING BOARD _ DECISION City of Northampton Date:April 1, 2004 APPLICATION TYPE: SUBMISSION DATE: Comprehensive Permit 7/3/2003 Ap licant's Name: Owner's Name: Surveyor's Name: NAME: NAME: COMPANY NAME: Pioneer Valley Habitat for Humanity CITY OF NORTHAMPTON ADDRESS: ADDRESS: ADDRESS: P O BOX 60642 212 MAIN STREET TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: FLORENCE MA 01062 NORTHAMPTON MA 01060 PHONE NO.: FAX NO.: PHONE NO.: FAX NO.: PHONE NO-: FAX NO.: (413)586-5430 0 (413)587-1000 0 EMAIL ADDRESS: EMAIL ADDRESS: EMAIL ADDRESS: Site Information: STREET NO.: SITE ZONING: 39 VERONA ST URB TOWN: SECTION OF BYLAW: NORTHAMPTON MA 01060 MAP: BLOCK: I LOT: MAP DATE: ACTION TAKEN: 17D 1 071 001 Approved With Conditions Book: Page: 4685 81 NATURE OF PROPOSED WORK: Comprehensive permit for six new affordable housing units(3 duplexes)and one new market rate home and one existing market rate home.Permit covers subdivision approval for the extension of Garfield Avenue. HARDSHIP: CONDITION OF APPROVAL: 1.Applicant must follow al/administrative requirements within the subdivision rules regarding recording,performance guarantees,providing digital files,etc. The only waivers approved are those summarized in this permit 2.Prior to final endorsement of subdivision mylar,and prior to recording the subdivision,applicant must revise plans showing an accurate cross section of the roadway and sidewalk detail and location of permanent bounds as specified in§7:20 of the subdivision rules.Mylars must also contain a signature block for Planning Board to sign in accord with§6:03(12).This block should contain language stating this subdivision was approved through a Comprehensive Permit decision of the Zoning Board of Appeals under M.G.L.Chapter 40B. 3.Prior to endorsement of the subdivision mylar,a performance guarantee that conforms to Northampton Subdivision Rules and Regulations§6:06(4)must be posted. The developer may place a covenant not to sell or request a certificate of occupancy(land or lots except between the City and Habitat for Humanity)or,in lieu of placing a covenant post a Letter of Credit in accordance with the standards in the Regulations. If a Letter is posted,the Letter may not be reduced below the original amount posted until the project is complete and has been accepted as such by the Planning Board. 4.Prior to endorsement of subdivision mylar,detail sheets of the sediment forbay and stormwater system shall be provided. 5.Prior to final endorsement,the applicant shall submit plans that show a work limit line that is coterminous with or southerly of the landfill boundary(except in the area where the private sewer connection is located) The work limit line detail shalt show orange construction fencing,silt fence and hay bales. Restrictive Covenants/Declaration of Trust: 6. Covenant agreements that detail assignment of responsibility for snow removal from the parking area and maintenance of the private sewer line. Covenants must clearly state that the Home Owners' or Condo Assoclation(Association)is responsible for snow and ice removal from the common parking lot that may result from stormwater coming from Garfield Avenue. GeoTMS®2004 Des Lauriers Municipal Solutions,Inc. SMALL LOTS BIG IDEAS -- 1 GARIFIELD AVENUE PROJECT DESCRIPTION This application for 1 Garfield Avenue falls under the Garfield Avenue Comprehensive Permit issued to Habitat for Humanity on April 1, 2004. This property is referred to as either Lot 1 or Lot 1A within the Cluster Development. Property Description: The six-sided lot is located at the end of Garfield Avenue, on the westerly side, abutting the Florence Conservation area on 4 of its 6 sides. As shown in Figure 1, this property has one front line (F1), 4 side lines (S1-S4) and one rear line (R1). The following waivers were granted for Lot 1 by the ZBA decision: • 25' Frontage (Appendix A- Waiver#4) • No curb cut required (Appendix A- Waiver#7) There is only one abutting property with a house located at 3 Garfield Avenue. That house is set approximately 12' from the property line. Wayne Feiden has explained to me that the Density and Dimension regulations are determined by the 2004 ZBA Decision and frozen to the 2004 Zoning regulations (Appendix B). This property is part of the Open Space Residential Cluster Housing Development. SETBACKS FRONT SIDE 1 REAR HEIGHT PRIMARY STRUCTURE (House) 15' 10' 15' 35' _............. _. ACESSORY STRUCURE (Garage) 15' 4' 4' 35' OPEN SPACE LOT SIZE OPEN % OPEN Sq. Ft. Minimum Open Space: —5160 Sq. Ft 65% —3400 Sq. Ft. I F Proposed—TOTAL 1750 3 65% —3450 Sq. Ft House 1100 Sq. Ft. Garage 400 Sq. Ft. Driveway 250 Sq. Ft. ATTACHMENTS: 1. Figure 1 shows the proposed house and detached garage footprint. 2. Figure 2 shows a Sketch Plan from the street perspective. 3. Appendix A shows the 2004 ZBA decision waivers. 4. Appendix B is the URB Dimension table from the 2004 zoning regulations. 5. Appendix C is the Small Lots, Big Ideas specification page. ioas nnF-' CITY OF NORTHAMPTON � asF BOOK a885 -PAGE 81 ! ' - - PLAN BOOK 59-�PAGE TD ,gg PAGE SOCK 8557- B :I 8832—PACE 177 kr#I §#1}i�t(� PUN BOOK 207 PAGE 44 REUMNINO LAND OF The CITY OF NORTHAMPTON t { TO BE FIESER4£D FOR - CONSEAVA'O0N AND OPEN SPACE PURPOSES 4.097 ACRESf .... (178.447 SO.FT.t) s a .,N 11 LOT IA. i t w 3 n A 1 LL A o.. r , ( s i t l I L@ i (Gi.Y Tl Lbil /dd 53 F13 � - tot• }V-.S f t.tl � ; I L9T 5 lW£1 fl.Y V > t v- -='E'he Ptare nj l�rui in - DtsiLn Northampton,Massachusetts ,Syt1r•ot'al uat Required .. t Gx1up-Inc- ruvr—Or t <._ "FLORENCE ._ � _.;�•,•:°• Crt> of Northctrnl7ton CONSERVATION .. 1{I AREA" Y= Office of Planning and 5'nstainabiliA, � ° ,w. s .,a.... - r ° , -fW' 00" oil , . . i L 0 A .-A Al lit ,W �/)gyp - 1 plow 1 1 i 3(o I _ :0 �4 LIME AND CURVE TARE LWE A;a GA'&E, TABLE L' 61 55"40'' 15.'16' LLS: R-1:;f.I,�IS' L-14,15' L3: R-333i,H!Ri' L-15.Dd LZ Is EV-37'23"m E,;'31 Los N72'47`46"yid 2,.5FE:' LID: St4,'I.I`I'G6,'W 15x67, L5: R-255.HV L-51.Ed Lid: S77'3I'391E 14.01' L6 P4 7 5'2 "35 W .{ U-1 a X114Kt9't b5"E 2 a-54' La': N2,T E'2 �`W '31. 34' L2'L: V f"3`1'391E W .� LS. Ni j— 14tufL 2. ,ti' L rj: NIT]2"OTE 9.11' L 1: k;=a216 q-,W L q O 31+ L7i!: Rj Ob CU L Sf.6D" 1, 4 W-55 f'4a:1"3?"'W 74' 01; R—I'STIS' U,7 11 y1E<9W Lr, 9-76' � i x y Site Overview/ Opportunities and Challenges The lot is at the end of a dead end road at 1 Garfield Avenue, Lot IA. The lot 50' wide and a minimum of 100' deep, with 30' of street frontage. Total lot area is 5,200± square feet. On the north and west the property is abutted by the Florence Conservation Area. The lot is part of a mixed-income residential area, located between several Habitat for Humanity homes recently constructed and currently under construction and Florence Conservation Area, with market-rate homes and subsidized and market rate apartments nearby. The larger neighborhood includes a large number of century+ old single family homes. Frequently Asked Questions Zoning frontage: This lot conforms because of a comprehensive permit already issued Zoning front yard setback 15 feet Zoning side yard setback 10 feet Zoning rear yard setback 15' Maximum height 35' (measured to the midpoint on a gabled roof) No program provided (beyond single family home or single family home with a maximum of a 900 square foot attached accessory apartment): leave to architect VLWZ�txuA 11VR ANN UPLN srncx FU?Ce gars 4,097 ACRES (178.447 SO,Fi.3) OM e xrnn SP F m _ MOP' LUf 1A L.6 Sj.7Ctr 'd 76475 i y y�yyy � 7t t-; I Nf L# " f 5 Principal Use Minimum Required Lot Minimum Setback Maximum Minimum Building Open Area tFrontage I Front I Side Rear Height Space URB Urban Residential—B Zoning District Single Family dwellings 8,000 75 80 20 15 20 35 50% Detached accessory structures NA NA NA 15 4 4 20 50% (but no larger than 1,000 s .ft.of lot coverage) > See also§6.7 Accessory structures attached to a principal residential structure,used NA NA NA 40 10 10 20 50% only as a garage,storage space,or workshop,for non-commercial purposes and not for any other uses.* *ZBA may grant a Special Permit to reduce the front yard setback to 20 when it finds it will be no more visually intrusive than a detached structure in the same location. Zero Lot Line Single Family homes 8,000 65 80 20 15/0 20 35 45% Two family dwellings 12,000 80 100 20 15 20 35 50% Townhouse and other multi-family units 7,000 per unit 120 150 30* 30 30 40 40% *The Planning Board may reduce the minimum front yard setback requirement for townhouses to 20'to create a particular character in a development Any principal use being serviced by on-site water AND on-site sanitary sewage disposal. 80,000 80 100 20 15 20 35 F Assisted Living Residence or Nursing Home 20,000+1,000 100 120 30 30 20 35 er bedroom Municipal Facilities None None None 20 15 20 35 Lots within an Open Space Res.Development (Cluster§10.5)or PUD (§10.6) Single family homes 5,000 70 70 15 10 15 35 65% Zero Lot line Single-Family homes>See§10.14 4,500 60 70 15 10/0 15 35 60% Two family homes 7,500 75 100 15 10 15 35 65% Three family homes 10,000 80 125 15 10 15 35 65% 5,000 per unit 75+5 per 150 15 10 15 40 65% Townhouse unit Multi-Family 5,000 per unit 75+5 per 150 15 10 15 45 65% unit Any other permitted use not listed above 10,000 80 90 20 15 20 35 50% Preexisting nonconforming uses 10,000+ 1,000 80 90 20 15 20 35 50% per unit 08/25/15 6-5 ZONING BOARD DECISION City of Northampton Date: April 1,2004 Ordinances. The permit includes subdivision approval for the extension of Garfield Avenue to create a three-lot cluster that will result in creation of six new affordable housing units on Lots 2 and 3 and one new market rate unit on Lot 1. The approval provides for a reduction in dimensional requirements for the new lots as well as approval for reduction in required frontage for 155 Chestnut Street(Map ID 17C-66). The Board granted the following exemptions and waivers as part of the Comprehensive Permit's provision of six affordable units out of a total of eight units: 1.Reduction in minimum radius of road centerline(250'to 235+-)for a street§7:01(9)of the Northampton Subdivision Rules. 2.Reduction in right-of-way width.Providing 40'instead of required 60'in order to match the existing right-of-way width. 3.Reduction in 'hammerhead'length(66'to 40'to match right-of-way). 4.Reduction in frontage for Lot 1 from 70'to 25'to allow reduction in overall length of street and right of way. 5.Reduction of frontage for Lot 3 from 85'to 70'to reduce road infrastructure. 6.Reduction in legal frontage for 155 Chestnut Street(Map ID 17C-66;Plan Book 115 Page 52 lot 1)from 75'to 50:Frontage to be transferred from Garfield Avenue to Chestnut Street. 7.Waiver for all city permits related to the curb cuts for Lots 1,2,and 3. Two curb cuts approved for Lots 2 and 3 and one approved for Lot 1,maximum 1 allowed. 8.Waiver from providing full traffic study. A summary of traffic impacts was provided. 9.As shown on the approved plan sheet L1,side setback on Lot 3 is reduced from 15'to 12'to accommodate the side entry, The Findings of the Zoning Board of Appeals were based on public comments,recommendations from the Northampton Planning Board and Northampton Department of Public Works. Northampton Police and Fire Departments were consulted and had no concerns about the proposed development The Zoning Board of Appeals determined: A. The requested use includes provision for surface water drainage,sound and sight buffers and preservation of views,light,and air. A tree buffer will be provided along the boundary of Lot 3. Surface water drainage will improve water quality and quantity flowing off site; and B. The requested use will promote the convenience and safety of vehicular and pedestrian movement within the site and on adjacent streets,minimize traffic impacts on the streets and roads in the area. Consideration of the location of driveway openings in relation to traffic and adjacent streets,access by emergency vehicles,the arrangement of parking and loading spaces,and provisions for persons with disabilities has been made. The project includes creation of a sidewalk along one side fo the road extension and a hammerhead for emergency vehicle access turnaround. Driveway openings will be located on all three lots and will not negatively impact traffic function on the dead-end street;and C. The requested use will promote a harmonious relationship of structures and open spaces to the natural landscape,existing buildings and other community assets in the area.A majority(4+acres)of the site will be permanently protected as open space to be owned by the Northampton Conservation Commission,including permanent protection of the capped landfill. Public access to the open space will be provided through an easement across Lot 3. All development will be outside the wetland buffer zones;and D. The requested use will not overload,and will mitigate adverse impacts on,the City's resources including the effect on the City's water supply and distribution system,sanitary and storm sewage collection and treatment systems,fire protection,streets and schools. Stormwater will be mitigated on site. There is adequate capacity in the private sewer line to which this project will connect.;and E. The requested use bears a positive relationship to the public convenience or welfare. The use will not unduly impair the integrity of character of the district or adjoining zones,nor be detrimental to the health,morals,or general welfare. The use shall be in harmony with the general purpose and intent of the Ordinance. The project for four singe/family homes in a cluster provides units that will be consistent with the rhythm and the character of the neighborhood along Garfield Avenue;and F. The requested use will promote City planning objectives to the extent possible and will not adversely effect those objectives,as defined in City master or study plans adopted under M.G.L. Chapter 41,Section 81-C and D. Cluster in-fill development as recommeneded within the City's Vision 2020 document provides new residential units while permanently perserving open space. COULD NOT DEROGATE BECAUSE: FILING DEADLINE: MAILING DATE: HEARING CONTINUED DATE: DECISION DRAFT BY: APPEAL DATE: 1211112003 1213112003 211212004 41812004 REFERRALS IN DATE: HEARING DEADLINE DATE: HEARING CLOSE DATE: FINAL SIGNING BY: APPEAL DEADLINE: 1212412003 11812004 312512004 41512004 412112004 FIRST ADVERTISING DATE: HEARING DATE: VOTING DATE: DECISION DATE: 1212512003 11812004 312512004 41112004 SECOND ADVERTISING DATE: HEARING TIME: VOTING DEADLINE: DECISION DEADLINE: 11112004 5:30 PM 1 41712004 MEMBERS PRESENT: VOTE: Malcolm Smith votes to Grant David Bloomberg votes to Grant Sara Northrup votes to Grant GeoTMS®2004 Des Lauriers Municipal Solutions,inc. ZONING BOARD _ DECISION City of Northampton Date:April 1, 2004 APPLICATION TYPE: SUBMISSION DATE: Comprehensive Permit 71312003 Applicant's Name: Owner's Name: Surveyor's Name: NAME: NAME: COMPANY NAME: Pioneer Valley Habitat for Humanity CITY OF NORTHAMPTON ADDRESS: ADDRESS: ADDRESS: P O BOX 60642 211 MAIN STREET TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: TOWN: STATE: ZIP CODE: FLORENCE MA 01062 NORTHAMPTON MA 01060 PHONE NO.: FAX NO.: PHONE NO.: FAX NO.: PHONE NO.: FAX NO.: (413)586-5430 0 (413)587-1000() E L ADDRESS: EMAIL ADDRESS: EMAIL ADDRESS: Site Information: STREET NO.: SITE ZONING: 39 VERONA ST URB TOWN: SECTION OF BYLAW: NORTHAMPTON MA 01060 MAP: BLOCK: I LOT: MAP DATE: ACTION TAKEN: 170 1 071 001 Approved With Conditions Book: Page: 4685 81 NATURE OF PROPOSED WORK: Comprehensive permit for six new affordable housing units(3 duplexes)and one new market rate home and one existing market rate home.Permit covers subdivision approval for the extension of Garfield Avenue. HARDSHIP: CONDITION OF APPROVAL: 1.Applicant must follow all administrative requirements within the subdivision rules regarding recording,performance guarantees,providing digital files,etc. The only waivers approved are those summarized in this permit 2.Prior to final endorsement of subdivision mylar,and prior to recording the subdivision,applicant must revise plans showing an accurate cross section of the roadway and sidewalk detail and location of permanent bounds as specified in§7:20 of the subdivision rules.Mylars must also contain a signature block for Planning Board to sign in accord with§6:03(12). This block should contain language stating this subdivision was approved through a Comprehensive Permit decision of the Zoning Board of Appeals under M.G.L.Chapter 40B. 3.Prior to endorsement of the subdivision mylar,a performance guarantee that conforms to Northampton Subdivision Rules and Regulations§6:06(4)must be posted. The developer may place a covenant not to sell or request a certificate of occupancy(land or lots except between the City and Habitat for Humanity)or,in lieu of placing a covenant,post a Letter of Credit in accordance with the standards in the Regulations, if a Letter is posted,the Letter may not be reduced below the original amount posted until the project is complete and has been accepted as such by the Planning Board. 4.Prior to endorsement of subdivision mylar,detail sheets of the sediment forbay and stormwater system shall be provided. 5. Prior to final endorsement,the applicant shall submit plans that show a work limit line that is coterminous with or southerly of the landfill boundary(except in the area where the private sewer connection is located) The work limit line detail shall show orange construction fencing,silt fence and hay bales. Restrictive Covenants/Declaration of Trust: 6. Covenant agreements that detail assignment of responsibility for snow removal from the parking area and maintenance of the private sewer line. Covenants must clearly state that the Home Owners' or Condo Assoclation(Association)is responsible for snow and ice removal from the common parking lot that may result from stormwater coming from Garfield Avenue. GeoTMS®2004 Des Lauriers Municipal Solutions,Inc. Primary Structure (house): - Two Story with a walk out basement and accessory apartment less than 900 square foot. - Maintains the character of the neighborhood with GABLE roof and an (8) on [12] roof pitch. - The house will be oriented towards SOLAR SOUTH to maximize passive solar gain. - The house's roof PEAK will be less than 30' and sub-ordinate to the 2-story house at 3 Garfield Ave. Accessory Structure (garage): - One-story accessory structure (garage) will be oriented about 150 EAST of SOLAR SOUTH: • To facilitate car access to the garage door from the street. • To increase morning active solar gain. - The garage will also feature a GABLE roof, in a possible SALTBOX configuration, with the roof slope determined by the optimal solar azimuth, between (8) and (10) on [12]. " F r x .M .. " f- 4 4 , Figure 2. View From Street. S3a 4' 10' 4' S4 4, 5' R1 15' ,- 151 v � � f f t 15' !� F1' 10' 4 S2 S1 . Primary Structure setback Accessory Structure setback FIGURE 1. SMALL LOTS, BIG IDEAS -- 1 GARIFIELD AVENUE PROJECT DESCRIPTION This application for 1 Garfield Avenue falls under the Garfield Avenue Comprehensive Permit issued to Habitat for Humanity on April 1, 2004. This property is referred to as either Lot 1 or Lot 1A within the Cluster Development. Property Description: The six-sided lot is located at the end of Garfield Avenue, on the westerly side, abutting the Florence Conservation area on 4 of its 6 sides. As shown in Figure 1, this property has one front line (F1), 4 side lines (S1-S4) and one rear line (R1). The following waivers were granted for Lot 1 by the ZBA decision: • 25' Frontage (Appendix A- Waiver#4) • No curb cut required (Appendix A-Waiver#7) There is only one abutting property with a house located at 3 Garfield Avenue. That house is set approximately 12' from the property line. Wayne Feiden has explained to me that the Density and Dimension regulations are determined by the 2004 ZBA Decision and frozen to the 2004 Zoning regulations (Appendix B). This property is part of the Open Space Residential Cluster Housing Development. SETBACKS FRONT SIDE REAR HEIGHT PRIMARY STRUCTURE (House) 15' 10' 15' 35' ACESSORY STRUCURE (Garage) 15' 4' 4' 35' OPEN SPACE LOT SIZE OPEN % OPEN Sq. Ft. Minimum Open Space: —5160 Sq. Ft. 65% "3400 Sq. Ft. Proposed —TOTAL 1750 65% "3450 Sq. Ft House 1100 Sq. Ft. Garage 400 Sq. Ft. Driveway 250 Sq. Ft. ATTACHMENTS: 1. Figure 1 shows the proposed house and detached garage footprint. 2. Figure 2 shows a Sketch Plan from the street perspective. 3. Appendix A shows the 2004 ZBA decision waivers. 4. Appendix B is the URB Dimension table from the 2004 zoning regulations. 5. Appendix C is the Small Lots, Big Ideas specification page. 10. Do any signs exist on the property' YES NO IF YES, describe size, type and location: Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: 11. Will the construction activity disturb(clearing,grading, excavation, or filling)over 1 acre or is it part of a common plan of development that will disturb over 1 acre? YES NO i,--- IF YES, then a Northampton Storm Water Management Permit from the DPW is required. 12. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION This column reserved for use by the Building Department EXISTING PROPOSED REQUIRED BY ZONING Lot Size (OD Frontage 2-51 Setbacks Front I'S (15) t l5 P? (AC) Side L: jDt4) R- jc> (4) L; R: ID(H) L: R. Rear TJ q) (4) Building Height 2>6) 1 Building Square Footage A-7 %Open Space:{lot area —5 minus building&paved parking #of Parking Spaces 0 -2- #of Loading Docks D D Fill: LrEPT r3'7-:i+(ND (volume& location) RAaliei Fog H"M AJJ IT-41 P I LGC 13. Certification: I hereby certify that the information contained herein is true and accurate to the best of my knowledge. Date: q ht) 15 Applicant's Signatura —�13r- NOTE:Issuance of a zoning permit does not relieve an applicant's burden to comply with all zoning requirements and obtain all required permits from the Board of 11calth,Conservation Commission, Historic and Architectural Boards, Department of Public Works and other applicable permit granting authorities. 814r-004 _ File No. ZC.J►.NING PERM-IT A "P LICATIQ.N(§YO.2) Please type or print all information and return this form to the Building Inspector's Office with the $15filing fee (check or money order)payable to the City of Northampton 1 Name of Applican{t:jj A 5 L L Address: A/0 �T-FLD ter–.10Ct—_Telephone: 1 �3 2. Owner of Property: 1, tA 11i-'i I .S OA �C-E C—L -. Address: Y14� Telephone: 3. Status of Applicant: Owner � Contract Purchaser Lessee Other(explain) 4. Job Location: ' Parcel Id: Zoning Map# Parcel# District(s): In Elm Street District In Central Business District O BE FILLED IN BY THE BUILDING DEPARTMENT) 5. Existing Use of Structure/Property: P & Description of Proposed Use/Work/Project/Occupation: (Use additional sheets if necessary): 7. Attached Plans: Sketch Plan Site Plan t Engineered/Surveyed Plans 8. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES l/J IF YES, date issued: t Ll IF YES: Was the permit recorded at the Registry of Deeds? NO DON7 KNOW YES IF YES: enter Book Page and/or Document 9.Does the site contain a brook, body of water or wetlands? NO " DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained date issued; (Form Continues On Other Side) W:OmumenisUt)RMSktriginal\Building-InspectrrrV-onint Permit-Aprlictitinn-passive.d(x 5/4[20i4 ��. 18. Dn any signs exist on thepmperty7 YES IF YES, describe size, type and location: Are there any proposed changes to or additions of signs intended for the property? YES_NO ______ iF YES, describe size, type and location: 11. Will the construction activity disturb(o/oaring.grading,excavation, orfi|Ung��over1o:nwnriuitpmrtnYoonmmun h plan of development that vi disturb over 1acre? YES i~°~ IF YES, then a Northampton Storm Water Management Permit from the DPW is required. 12' ALL INFORMATION MUST BE COMPLETED,or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION Z&is colu.mn reserved for use by the Building Department EXISTING PItOPOSED REQUIRED BY ZONING Lot Size Frontage Setbacks Front pp (AC ) Side L: R.- (o (4) L: R: L-. 8: Rear 15 M Building Height Building Square Footage Lioc3v V-50 %Open Space-(lot area C�) minus building&paved C) parking #of Parking Spaces 13. Certification: I hereby certify that the information contained herein is true and accurate to the best of my knowledge. Date- Applicant's Signmtu//ZO NOTE:Issuance mfazoning permit does not relieve an applicant's burden mwmompIy"idb all zoning requirement sand obtain all required permits from the Board nfy1cmlth'Conservation Commission, mlistoric and Architectural Boards,Department u{Public Works and other applicable permit granting uut6mritims' w/o�o�m'�nmnwnvv�iommvoumx'*^*�mumuiac'p"vnu'anv/aao"n���v�a"r uxomw -- _ File No.-- ` 1 ZONING PERMIT APPLICATION 01o.2) Please type or print all information and return this form to the Building Inspector's Office with the $15 fzltng fee (check or money order)payable to the City of Northampton 1. Name of Applicant: }} �r , 14 E-L Address: ( I t L F L,1� CE Telephone:, k L3 5 `-T 3- 2. Owner of Property: —T1A 14.S k C-�i U Address: 5Ayif'l tw Telephone:—S 3. Status of Applicant: Owner �.Contract Purchaser Lessee Other(explain) 4, ,lab Location: ! �f ( 1 lJ Parcel Id: Zoning Map# Parcel- _ _District(s): In Elm Street District In Central Business District O BE FILLED IN BY THE BUILDING DEPARTMENT) 5. Existing Use of Structure/Property: 1) tJ N::-,\J E Lo P a`=l 6. Description of Proposed Use/Work/Project/Occupation: (Use additional sheets if necessary): C G S 6>r - - 6 V\ c--. 8<7k Ck C, t e- c—, Vt 7. Attached Plans: Sketch Plan Site Plan t Engineered/Surveyed Plans 8. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES ~ IF YES, date issued: Ll IF YES: Was the permit recorded at the Registry of Deeds? NO DONT KNOW YES L'� IF YES: enter Book Page and/or Document# 9.Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , date issued: (Form Continues On Other Side) W:U)ocumentsUr OR MS\o6ginaMuiiding-lnspectorV-oning-Permit-Application-passive.dtx t 144-004 File#MP-2016-0017 APPLICANT/CONTACT PERSON MICHEL THOMAS ADDRESS/PHONE P O BOX 60657 (413)588-7373 Q PROPERTY LOCATION 1 GARFIELD AVE MAP 17D PARCEL 081 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT_APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT � n Fee Paid i 775 ! ) 7 Building Permit Filled out Fee Paid Typeof Construction: ZPA- SFH W/ACCESSORY APT&DET GARAGE New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building,Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER : § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: §-A Vutf 0b 6-04M f26Z,1-4 I T Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning&Development for more information.