18C-106 (4) ����
. ,
��
- rr�
9
I gggggg
k'.r��
I9 �/
..I:..-..:.. +R..
f rt/x"
#�j/
t
1 . .. � _ mm �.�.�_� _ __� __ �__.__ ____�._
e
--�, � .
�� � ��.�.� __�.,�_ �_��_.a. . .�__�._.e�_ _.�_� �,,._._
_�
. _. a
.�_ — _ � .. _ .. a ��
y � _ � i
E1}
�#� �
� � L./ tt,,''t
E ... �.
3
� E
�{��
..,',
Rt rac- tesit€at al BuLtghtw4:ummercla1 FivA Loo mite oftw0ft t}earretopmed
Reidy Rem o&C 1 �t ettC rnp
Proiect Report
Cerxel Pry ,r titrattn� _
Project Filename: C:A Users\USER\Documents\RHVAC\Sharpeline Gleason Rd N'Hamp't.rhv
Project Title: Sharpeline Hamp
Designed By: RJR
Project Date: Thursday, February 12, 2015
Client Name: Sharpline Construction
Client Address: 59 Gleason Road
Client City: Northampton, MA 01060
Client Phone: 413-246-1071
Company Name: Reidy Htg& Cig
Company Representative: RJR
Design
Reference City: Westover AFB, Massachusetts
Daily Temperature Range: Medium
Latitude: 42 Degrees
Elevation: 270 ft.
Altitude Factor: 0.990
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference
Winter: 0 0 0 72 0
Summer: 87 71 50 73 28
Check Flgurear,,, "
Total Building Supply CFM. 833 CFM Per Square ft.: 0.637
Square ft. of Room Area: 1,308 Square ft. Per Ton: 649
Volume(ft')of Cond. Space: 10,464 Air Turnover Rate (per hour): 4.8
TBo�rtradl t"HeatingRequired With Out sid_e
Air, 47,008 Btuh 47,008 MBH
Total Sensible Gain: 18,147 Btuh 88 %
Total Latent Gain: 2,524 Btuh 12
Total Cooling Required With Outside Air: 20,671 Btuh 1.72 Tons (Based On Sensible+ Latent)
2.02 Tons (Based On 75%Sensible Capacity)
r
__
14otes
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\USER\Documents\RHVAC\Sharpeline Gleason Rd N'Hamp't.rhv Thursday, February 12, 2015,2:18 PM
Rhvac-Residential&tight Commercial HVAC Loads Elite oftwanr 1 v Ippgrl ►f to .
Reidy Heating 8 Coaling Inc. Starpet�ne 1#atrrp
Holyoke,MA 01040 gel°
System 9 Room Load Summary
Run , Run
LO
Roam Ateal` dens i s: Cunt: DUCA Sens
Btuh' ';,CFM .. 6, :.. Vel. stub..
---Zone 1---
1 Main Home 918 26,603 349 5-5 630 9,355" 1,660 429 429
2 Addition 390 17,878 234 5-5 592 8,792 863 404 404
System 1 total 1,308 47,008 616 18,147 2,524 833 833
System 1 Main Trunk Size: 18x9 in.
Velocity: 779 ft./min
Loss per 100 ft.: 0.088 in wg
Cooing ystrri Surtary
_.
rolrn SrrletLatent� ensiba Lafaz 0 , a
tons .u.. _ flit_...._.':.._.._ .. ' ttuh
Net Required: 1.72 88%/ 12% 18,147 2,524 20,671
Recommended. 2.02 75%/25% 18,147 6,049 24,196
Equipment Data
Heating System Cooling System
Type:
Model
Brand:
Efficiency:
Sound:
Capacity:
Sensible Capacity: n/a 0 Btuh
Latent Capacity: n/a 0 Btuh
C:\Users\USER\Documents\RHVAC\Sharpeline Gleason Rd N'Hamp't.rhv Thursday, February 12, 2015,2:18 PM
Rhvac-Ftesidentiat&Light Commercial HVAC Loads Elite Software Davalgprt t t�Inc
Leidy Heating&Cooling Inc. Sharper Harrp
..... .. .. gtr '
Holyoke,MA 01040,
System 9 Addition & Main Home Summary Loads (Average Method)
CornpQ'taent Area Salt 'Lit ��� �
I7escrf) Quan Lass atrt
1 D-cv-o: Glazin Double....- -.,._._..1.w-i� - c-e._,',-- w.. �__ ..._
_ g- pane, operable window, clear, 200 8,200 0 8,581 8,581
vinyl frame
110,' Door-Polystyrene Core With Storm 42 636 0 220 220
12C-2sw: Wall-Frame, R-13 insulation in 2 x 4 stud cavity, 1070 6,240 0 1,596 1,596
R-2 board insulation, siding finish, wood studs
16CR-19: Roof/Ceiling-Under attic or knee wall, Vented 1308 4,615 0 2,499 2,499
Attic with Radiant Barrier, Dark Asphalt Shingles or
Dark Metal, Tar and Gravel or Membrane, R-19
insulation
19A-Otp: Floor-Over enclosed unconditioned crawl space, 1308 11,277 0 2,193 2,193
No insulation on exposed walls, sealed or vented
space, passive, no floor insulation, the or vinyl
Subtotals for structure: 30,968 0 15,089 15,089
People: 3 600 690 1,290
Equipment: 250 500 750
Lighting: 0 0 0
Ductwork: 3,938 508 937 1,445
Infiltration: Winter CFM: 122, Summer CFM: 61 9,575 1,166 931 2,097
Ventilation. Winter CFM: 0, Summer CFM: 0 0 0 0 0
Humidification(Winter)6.89 gal/day : 2,527 0 0 0
System 1 Addition& Main Home Load Totals: 47,008 2,524 18,147 20,671
Check Figures
Supply CFM: 833 Per Square ft.: 0.637
Square ft. of Room Area: 1,308 Square ft. Per Ton: 649
Volume(ft')of Cond. Space: 10,464 Air Turnover Rate (per hour): 4.8
m�
System Loads
Tota! Heating Required With Outside Air: '4'7,008 Btuh 47.008 MBH
Total Sensible Gain: 18,147 Btuh 88 %
Total Latent Gain: 2,524 Btuh 12 %
Total Cooling Required With Outside Air: 20,671 Btuh 1.72 Tons(Based On Sensible+Latent)
2.02 Tons(Based On 75% Sensible Capacity)
Notes_ _ ...
Calculations are based on 8th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
C:\Users\USER\Documents\RHVAC\Sharpeline Gleason Rd N'Hamp't.rhv Thursday, February 12, 2015, 2:18 PM
File# SM-2016-0016
APPLICANT/CONTACT PERSON REIDY HEATING&COOLING INC
ADDRESS/PHONE 539 SOUTH CANAL ST (413)534-3749 Q
PROPERTY LOCATION 59 GLEASON RD
MAP 18C PARCEL 106 001 ZONE URB000)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out
Fee Paid
Typeof Construction: ADD ZONE SYSTEM IN ADDITION
New Construction
Non Structural interior renovations
Addition to Existing _
Accessory Structure
Buildiniz Plans Included:
Owner/Statement or License 2670 _
3 sets of Plans/Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFOylrPvi"ATION PRESENTED:
//Approved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER: §
Intermediate Project: Site Plan AND/OR Special Permit with Site Plan
Major Project: Site Plan AND/OR Special Permit with Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
e tr et Co issio Permit DPW Storm Water Management
S n m icia Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
* Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of
Planning&Development for more information.
INSURANCE COVERAGE:
I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Yes 9-40❑
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy E!j Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application waives this requirement.
Check One Only
Owner ❑ Agent
ignature of Owner or Owner's Agent
By checking this box❑,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation: YES NO -�
Date
Date
By
Title_
City/Town
Permit#
Fee$
Inspector Signature of Permit Approval
Progress Inspections
Comments
Final Inspection
Comments
Type of License:
Master
❑ Master-Restricted
❑Journeyperson
Signature of Licensee
Elio urneyperson-Restricted License Number:
Check at www.mass.gov/dpi
Commonwealth of Massachusetts
Sheet Metal Permit //
Date: 9•„2/— /j} Permit# 60-�L ` ' 7
Estimated Job Cost: $ Permit Fee: $a 5-
a5- I7 3
Plans Submitted: YES NO Plans Reviewed: YES NO
Business License# �`�/ Applicant License# 7G
Business Information: Property Owner/Job Location Information:
Name: r• 1,.,r Name: C1s' 000t` �plrft
Street:, ,5 5S//d�� �.��_X's r-e Street: ��1�
City/Town: vi City/Town:
Telephone: 5/�3 �3 y' --r v,Y f Telephone: 5�z Ir --.9 ,/d->'Z
Photo I.D. required/Copy of Photo I.D. attached: YES__,---NO_
Staff Initial
J-1 /M-1-unrestricted license
J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less
Residential: 1-2 family_,,--' Multi-family Condo/Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other
Square Footage: under 10,000 sq. ft. over 10,000 sq. ft. Number of Stories:
Sheet metal work to be completed: New Work: Renovation:
HVAC Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
o�o� z v..-r- —f
59 GLEASON RD SM-2016-0016
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS`#: 2_213
Map: 18C
Block:- 106 . , SHEETMETAL PERMIT
ii at: 001 ,..
ermit: SHEETMETAL
Category: SHEETMETAL
Permit# SM-2016-0016 PERMISSION IS HEREBY GRANTED TO:
Project# JS-2015-001968
Est. Cost: Contractor: License: Expires:
Fee Charged:$25.00 REIDY HEATING&COOLING IN Sheetmetal-2670
Balance Due:$.00 Owner: WOODWORTH DOUGLAS STEWART
#of Fixtures Applicant: REIDY HEATING&COOLING INC
DigSafe# --AT. 59 GLEASON RD
UseGroup
ConstGlass
ISSUED ON. 28-Sep-2015 AMENDED ON. EXPIRES ON:
TO PERFORM THE FOLLOWING WORK:
ADD ZONE SYSTEM IN ADDITION
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2016-001256 25-Sep-15 1733 $25.00
212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck @north amptonma.gov
GeoTMS®2015 Des Lauriers Municipal Solutions,Inc.