36-362
path of least resistance and carries 99%of the moisture in a structure.This is evident every time one exposes fiberglass insulation and finds black insulation,which has filtered dirt out of the air moving through the insulation.780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 41. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 42. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note:Thrul-oks are engineered for post attachment supporting a railing. Lateral attachment is required for each deck per section 502.2.2.3. 43. Smoke and CO detectors as required. 780 CMR R314 and R315. a. Smokes in each bedroom,within 10'of a bedroom door, and at the bottom of a stair leading to a finished floor above. b. CO within 10' of bedroom doors, at each level,for every 1500 sqft, (plumbing code in the mechanical room) Except if there are no fossil burning fuels or attached garage. c. Heat detector in attached garage, and other large unfinished unconditioned spaces. 44. Closets beneath stair which have doors must be drywalled with%". 780 CMR R302.7 45. If there is mechanical equipment or a combustible roof, 30 sqft of space, and 30" measured from top of ceiling joist to bottom of rafters an attic access of minimum RO of 22"x 30" is required to be located in an accessible place. It must be insulated equal to surrounding,gasketed, and secured in place. 46. Clearances above gas stoves and cook tops burners is 24" to non-combustible or 30" to combustibles. Relevant items must be submitted to the building department for approvals before inspections and or Certificates of Occupancy can be issued. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm,excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller(d,)northamptonma.gov z ank yo r your cooperation on these matters. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. Rails must be continuous and returned to the wall if not to newel post.780 CMR R311.7. 24. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36",4" sphere rule.780 CMR R312.1. 25. Floorjoist systems that are not equal to 1%" nominal dimension must be covered with%" drywall or 5/8" wood structural panel or equivalent with some exceptions. 780 CMR R501.3 26. Educate the plumber and electrician about maximum notch and hole sizes, and placement.780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom or to any other hole. Notches are different. 27. Drilling or notching of more than 50%of the wall plate width of an exterior wall or load bearing partition requires a 16 GA 1 %:" strap across the area and 6" beyond each side with 8- 10nd nails.780 CMR R602.6.1 28. Where dryer ducts penetrate the wall they must be sealed with fire caulk. 780 CMR M504.2 29. Dryer ducts must terminate outside of the building, have a backdraft damper, cannot include a screen, and require 3' clearance from windows.780 CMR M504.4 30. Dryer duct transition is limited to 8' of aluminum flex, must be exposed, and the proper UL listing.780 CMR M504.6.3 31. Dryer duct maximum equivalent length is 35' less 5' per 901 elbow or per manufacturer's specs. 780 CMR M502.6.4, no screwed connections use foil tape appropriate for the use. 32. Dryer ducts when concealed must have a permanent label or tag within 6' of the duct connection 780 CMR M502.6.5 33. Makeup air is required for dryers exhausting more than 200 CFM. 780 CMR M504.5 34. Makeup air is required for any exhaust hood over 400 CFM. 780 CMR M505.2 35. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5'from the duct outlet for all fireplaces and airtight doors. 2009 IECC 402.4.3 36. Fire and draft stopping shall be completed before rough inspection.Typical locations, top (ceiling)and bottom (floor) plates, soffits, and every 10' within enclosed cavities. 780 CMR R302. 37. Ignition barriers are required over all thermal plastics and must be in place before final.780 CMR R316. 38. Dwelling/Garage fire separation.An attached garage (within 3' of main structure) is required to have%" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have%" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 39. Energy aspects shall comply with the stretch energy code.780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist. Duct blast testing when practicable. f. All band joist insulation must be enclosed within an air tight cavity, which you must create. 40. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier.An air barrier is intended to stop air flow(convection) a vapor retarder or barrier is intended to stop molecular moisture transfer(diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. if air can leak through an electrical device or through a crack it follows the 10. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8-16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. 11. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3rd 780 CMR R802.3.1 12. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 13. A complete window and header schedule is required.780 CMR Table R502.5 for header sizing and number of jack studs required. 14. Wood walls shall be capped with double plates to provide overlapping at corners and intersecting walls with bearing partitions,joints staggered 2' minimum. 780 CMR R602.3.2 a. Exception: A single plate may be used or plates may be excluded over lintels provided the plates/lintels are adequately connected by a 3"x 6" plate .036 galvanized steel nailed to each segment with 6-8d nails 15. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I-joist and or Floor Truss c. Roof truss 16. All I-Joist need to be protected from fire with%drywall or 5/8 wood structural panel. (R501.3) 17. A braced wall plan identifying appropriate braced wall areas where required (R301.1) and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. c. When using PFH (R602.10.3.3)or PFG (R602.10.3.4)the nailing requirement is 4" and 3" respectively using 8d common nails or galvanized box nails. PNEUMATIC nails must be full headed with the temper and shank sizing meeting the strict code requirement. 18. When nailing sheathing make sure your pneumatic nailers' pressure is properly set. Nails set too deep perforate the sheathing weakening it and contribute to building damage in high wind events. 19. Ceiling heights minimum 7'for habitable spaces, 6'8" for bathrooms includes tub/shower area if a shower head is used, 6'8"for basements, 6'4" at beams/ducts. 780 CMR R305.1. MA amended 20. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations.780 CMR R308.4 21. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule.Order restrictors. 780 CMR R612.2 22. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape.780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20"x41" exception 5 sqft at I"floor. Minimum clear opening 20"x24" or 24"x20". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36", maximum step 7%"from the top of the threshold and only in-swinging doors. 780 CMR R311.3 23. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception,4 3/8" on balustrade, 6" in the triangle. Graspable rail 1%" minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or _ City of Northampton ` Massachusetts �� { us= DEPARTMENT OF BUILDING INSPECTIONS : z 212 Main Street • Municipal Building M °_ Northampton, MA 01060 INSPECTOR Shaul Perry September 17, 2015 84 Potwine Road Amherst, MA 01002 Subject Location: 115 Emerson Drive Map Block: 36-362 Mr. Perry, Your building permit application with plans has been approved as drawn and per this memo.All work must meet all applicable codes whether noted or not included within this memo. Please follow up on the following items: These items will need to be accomplished as the project moves forward and before rough inspections; 1. Structural work to be per RK Miles layouts. 2. Final ratings, duct blast results, and a signed Thermal Bypass Checklist. 3. Smoke, Heat and CO detectors throughout the structure to current building codes. 4. An emergency escape window is required within every bedroom, basement and walk-in attic. 5. An air barrier is required between the tub and the wall cavity. 6. If permeable insulation is used air sealing and an air sealing inspection is required at the exterior and interior skins.Typically the sheathing and drywall. Note:The 2012 IECC with MA amendments is the non-stretch energy code and the new Stretch Code expected to be completed in 2015. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. Read only international codes are available on line at http://publicecodes.cyberregs.com/icod/one must also consider the MA amendments to these codes which can be found at www.mass.gov/dps/bbrs . The current relevant building codes are: 2009 IBC, 2009 IEBC, 2009 IMC, 2009 IRC, 2009 or 2012 IECC,AA115, MA amendments. 1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required.780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3.except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. or if high water table or severe soils waterproofing 780 CMR R406.2. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement. 780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be%" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing. 780 CMR R406.1 see exceptions. 8. Emergency escape is required out of every basement whether habitable or not,each bedroom and walk- in attics. 780 CMR R310.1 9. Crawl spaces can be treated in three different ways,vented (poor idea), exhausted (similar to exhaust only systems), or treating the space with supply and return.See 780 CMR R408 t 115 Emerson Way-Update-cmiller @northamptonma.gov- City of NO.' https:/"mail.google.coni/nail/u/0/ginbox/14f89d9f362397e8 Click here to enable desktop notifi Mail Back Archive Spam Delete Moveto Labels More conMose 115 Emerson Way- Update Inbox x Inbox(4) 1 W Chris Harlow<chris @sunwood-builders.com> Starred am to me Important Hi Chuck, Sent Mail Attached,please find our revised plans for the 115 Emerson Way Building permit. Drafts(2) You had some additional questions,which I have address in he below. All Mail Spam(38) Need a plan for the rear deck,piers frame, Trash Please Revised Print Charles Miller_07022••• I assume there is nothing above the garage?Is the dormer gone?Where is the fire separation gc Charles Miller-07022... Garage is present.Please see revised plan for 14"floor joist and conventional framing ro( Charles Miller-07022... code chgs Is the front porch a SOG as shown? More Please see revised plan.Front porch will be constructed as a deck with piers. What is the fire protection for the I-joist?All drywalled? Basement will be finished and ceiling will be drywalled. I assume the walk out bedrm window meets emergency escape sizing? Yes. Egress window mill meet escape sizing. A tempered window is required at the bottom of the main stair. This window will be Tempered Glass. Is there brick veneer? No Brick Veneer.Siding will be Horizontal Fiber Cement. what is the heating system?need Manual"J",duct layouts and equipment spec. Please see attached Manual J �y ` Need HERS,water sewer, We expec a rating by tomorrow and will send it immediately over upon Thank you for your consideration and thank you for the quick Footing Inspection yesterday. Should we call ahead for the Footing Drain Inspection?We plan on being ready within a coup 1 of 1 9/2/2015 12:43 PM PI F CHI jk [ b 5 i PAj PFVSiONS MOM- 1°Q�N ! 11,260 s.f. .1 i 9,672 s.f. r ' r i I , rn _ 00 I I 0 Ic� ZIE I i I I I I I 1 i I; j li I I I - ` I I t 4„3J—P L=36.98' 1 W ,. �oetvkrse ua7t Emerson Way, LLC #115 (Lot 13) Emerson Way 08!16/2013 150 Main Street, Suite 310 ��— --��--- --- —________..___.__� ___�_ 3 33A\ 32\ 336 \ OWN -'alp \ 14.0' \ o 15.5' \� 342 15.5j ' 15�5' I 1 I _ _ I I D EMERSON WAY OF LOT 13 cy PROPOSED IMPROVEMENT LOCATION PLAN RANDALL GN IZ . y NORTHAMPTON, MASSACHUSETTS #E35032 PREPARED FOR ` SUNWOOD BUILDERS SURVE SCALE: 1"=30' AUGUST 11, 2015 HAROLD L. EATON AND ASSOCIATES, INC. REGISTERED PROFESSIONAL LAND SURVEYORS 235 RUSSELL STREET - HADLEY - MASSACHUSETTS � � �1855c2L1(R5[ti3 ' DEPARTMENT OF BUILDING INSPECTIONS 212 M2un Street ® -Municipal Building ,[NSPECTOR '~ sy Northampton,MA 01060 LOCATION SQUARE FOOTAGE AMOUNT BASEMENT @ .20 11T FLOOR @.50 , 2�FLR @6 J6 FLOORS, FINISH ATTIC,GARAGE @.20 . r DECK/PORCHES @ .20 } � TOTAL. ; x� l ® DATE(MMIDDNYYY) A�Ro CERTIFICATE OF LIABILITY INSURANCE 8/11/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONT ME:ACT NA Linda Powers Webber 6 Grinnell PHONE (413)586-0111 a No;(413)586-6481 8 North King Street A71M)FLESS:lpowers @webberandgrinnell.com INSURER(S)AFFORDING COVERAGE NAIC# Northampton MA 01060 INSURERAOhi_o Security/Liberty INSURED INSURER B A.I.M. Mutual Sunwood Builders, Inc. INSURERC: Attn: Shaul Perry INSURER D: 84 Potwine Lane INSURER E: _ Amherst MA 01002 1 INSURER F: COVERAGES CERTIFICATE NUMBER�Master 2015 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. rA ADDL SUBR POLICY EFF POLICY EXP LIMITS TYPE OF INSURANCE POLICY NUMBER MWDD/YYYY MMIDDIYYYY X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED 300,000 CLAIMS-MADE ❑X OCCUR PREMISES Ea occurrence $ BKS1655442304 3/4/2015 3/4/2016 MED EXP(Any one person) $ 15,000 PERSONAL&ADV INJURY $ 1,000,000 GENT AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY F PRO- ❑ LOC PRODUCTS-COMPIOP AGG $ 2,000,000 X JECT OTHER: AUTOMOBILE LIABILITY COMBINED a aB entSINGLE LIMIT $ 1,000,000 A X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED X SCHEDULED BAS1455442304 3/4/2015 3/4/2016 BODILY IJURY(Per accident) $ AUTOS AUTOS PROPERTY DAMAGE NON-OWNED $ HIRED AUTOS X AUTOS Per accident Medical payments $ 5,000 UMBRELLA LIAB HOCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- STATUTE ER AND EMPLOYERS'LIABILITY YIN E.L.EACH ACCIDENT $ 500,000 ANY PROPRIETORIPARTNERIEXECUTIVE NIA OFFICERIMEMBER EXCLUDED? B (Mandatory in NH) WMZ80080056582015A 5/22/2015 5/22/2016 E.L.DISEASE-EA EMPLOYE $ 500 000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE City of Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 240 Main St, Suite 3 ACCORDANCE WITH THE POLICY PROVISIONS. Northampton, MA 01060 AUTHORIZED REPRESENTATIVE Linda Powers/LMP ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD INS025(901401) SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicaabblee ❑ Name of License Holder: Gg- C1Sla QW License Number AU 0/00yf �Addr@ss Expira n Dat 0 ZW Sign Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ svlt wood � Company Name Registration Numb or AIV 0100v tJ1 Z Address 22 Q Expiration Date Telephone A3" 7 "� SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors 13 Accessory Bldg. ❑ Demolition ❑ New Signs [tom] Decks [M Siding [❑] Other[Co Brief Desc' do Pr p d Work: rU�a�sC/" Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family _ Two Family Other b. Number of rooms in each family unit: Number of Bathrooms/ c. Is there a garage attached? Y 's d. Proposed Square footage of new construction. 6-6/0 Dimensions '5�4/x' orb 1' e. Number of stories? l il���'✓ f. Method of heating? Fireplaces or Woodstoves umber of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction VCCJ i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No �Y j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? _Yes No . I. Septic Tank City Sewer Private well City water Supply r SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT as Owner of the subject property hereby authorize to act on b al , all matters relative to work authorized by this building perm' application. Signature o wner Date mom &LI P as Owner/Authorized Agent hereby declare that t e statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed nder the pains and penalties of perjury. Print Na Signature of owner/Agent Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage tu Setbacks Front � / --- — Side L: �� R: L. R. Rear Building Height ` Bldg. Square Footage 3d®Q Open Space Footage // -- % - (Lot area minus bldg&paved �G7® arkin ) #of Parking Spaces Fill: (volume&Location) ✓VC�RC/ NO/7r� - ------ A. Has a Sp *al Permit/Variance/Finding ever been issued for/on the site? NO DONT KNOW Q YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES 0 IF YES: enter Book Page and/or Document # B. Does the site contain a brook, body of water or wetlands? NO DONT KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued: C. Do any signs exist on the property? YES NO 0 IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading, ex t' n, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Department use only ity of Northampton status of Permit: y� 01ding Department Curb Cut/Driveway Permit J1 AUG z � 212 Main Street SewerfSepticAvailability Room 100 aterNVell Availability -- Ndrthampton, MA 01060 rao Sets of Structural Plans �r - "; ._ phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office i USCtiN a, � ��� Map C� Lot � Unit .f Joy/ �O�OGi� Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: L a ,0 'y Name( t) Currpl Mailing ddress: /. , v�U\ Telephone Signature 2.2 Authorized A ent: Nam Tint) Current Mailing Address: *f/3-666 ov# Signature Telephone SECTION 3-ESTIMATED CON RUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building • lyo,000.no (a) Building Permit Fee 2. Electrical , , vc� (b) Estimated Total Cost of DOO. Construction from 6 3. Plumbing Q ow oo Building Permit Fee 4. Mechanical (HVAC) 01,900.°O 5. Fire Protection vidwo ac' 6. Total= (1 +2+3+4+5) °O Check Number This Section For Official Use Only // Building Perml+M iAr Date Issued: Signature: Building Commissio4llnspector of Buildings Date File#BP-2016-0213 APPLICANT/CONTACT PERSON SHAUL PERRY I pA 1 I ADDRESS/PHONE 84 POTWINE LN AMHERST01002(413)259-1000 Fail l� V) 1 PROPERTY LOCATION 115 EMERSON WAY MAP 36 PARCEL 362 001 ZONE S6�� 0 THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: CONSTRUCT 2 STORY SFH W/ATT GARAGE/DECK/PORCH New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 065400 3 sets of Plans/Plot Plan THE FOLL WING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management ature of ui ding O ici Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 115 EMERSON WAY BP-2016-0213 GIs#: COMMONWEALTH OF MASSACHUSETTS Map.Block: 36-362 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Categoa:New Single Family House BUILDING PERMIT Permit# BP-2016-0213 Project# JS-2016-000361_ Est. Cost: $351000.00 Fee: $1175.60 PERMISSION IS HEREBY GRANTED TO Const. Class: Contractor: License: Use Group: SHAUL PERRY 065400 Lot Size(sq. ft.): 11238.48 Owner: SUNWOOD DEVELOPMENT CORP zonin : Applicant: SHAUL PERRY AT: 115 EMERSON WAY Applicant Address: Phone: Insurance: 84 POTWINE LN (413) 259-1000 WC AMHERSTMA01002 ISSUED ON 912112015 0:00:00 TO PERFORM THE FOLLOWING WORK.CONSTRUCT 2 STORY SFH W/ATT GARAGE/DECK/PORCH POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 9/21/2015 0:00:00 $1175.60 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner