Loading...
32C-001 (40) �Y �\ Louis Hasbrouck Building Commissioner City of Northampton 212 Main Street Northampton, MA 01060 8/16/15 RE: Cedar Chest 2nd floor renovations 150 Main Street Northampton, MA Dear Mr. Hasbrouck I am writing to kindly request that you grant a modification to waive the requirement for control construction for the above referenced project at Thornes Marketplace Northampton for Steve Ferrari of FCM Smart Build who has prepared the project scope of work. I have toured the project with the project manager and believe the work is of a minor nature, will not affect health, accessibility, life and fire safety, or structural requirements and is impractical in that the cost of control construction is considerable when compared to the cost of the proposed work Please except this stamped letter as consent that we allow for Steve Ferrari of FCM Smart Build to oversee the construction and implementation of this project. Thank you for your consideration. Respectfully, Tom Douglas Thomas Douglas Architects 196 Pleasant Street Northampton, MA 01060 196 Pleasant Street,Northampton,MA 01060 1 413.585.06412 ( tdouglasarchitects.com Code Review Thomas Douglas Architects,Inc. Renovations to Thornes Marketplace 196 Pleasant Street,Suite 202 150 Main St. Northampton,MA 01060 Northampton,MA 413-585-0641 3.3.2 If the work performed, including the exempted work, amounts to 30% or more of the full and fair cash value of the building, the entire building is required to comply with 521 CMR. This project's construction costs are:$85,000 The assessed value of the building (assessors web site) is:$3,854,400 This project's construction costs are less than 30%of the assessed value of the building and less than sioo,000. This building has an existing elevator that does not access the levels of the work area. The previous use of the work area was public. No private areas are being converted to public areas. All elements of public spaces will be constructed to accessible standards. The new cash register desks will have accessible counters. End of Document 6of6 Code Review Thomas Douglas Architects,Inc. Renovations to Thornes Marketplace 196 Pleasant Street,Suite 202 150 Main St. Northampton,MA 01060 Northampton,MA 413-585-0641 For M use and sprinklers: 75 ft maximum allowable common path of travel. The common path of travel to a point where there are a choices of exit routes is adequate to meet the code. 705.4.4 Panic Hardware There is no panic hardware. Doors will be open when the store is open to the public. 705.7 Means of Egress lighting All means of egress will have compliant exit signs. 705.7 Exit Signs The renovated space will have compliant egress lighting Ill and 607 Energy Conservation: Level i alterations are permitted without requiring the entire building to comply with the International Energy Conservation Code.Alterations (new construction) shall comply with the International Energy Conservation Code. A building that undergoes Level z alterations is required to meet a certain level of energy compliance. Where there are reconfigurations of the space or new doors or windows, any such new element is required to meet the International Energy Conservation Code. Elements within the building that are not being affected do not heed to be evaluated and do not nee to comply with the energy provisions. Essentially the entire building is not required to meet the energy provisions; only a degree of possible improvement in the energy performance of the building is intended to be achieved by malting the new elements meet the IECC. In certain cases where the reconfiguration of the space might have resulted in the creation of new spaces the newly created space should be evaluated as a whole for compliance with the energy provisions even though some of the element within the space might actually not have been altered. Likewise, in a case where an existing mechanical system is being extended to other areas or new ductwork is being installed to reconfigure and reroute the ducts to various spaces, it is only required to have the new elements meet the energy provisions and not the entire system. There are no new exterior walls, doors or windows 8o6 Accessibility CMR 5a1 3.3.1 b. If the work costs $ioo,000 or more, then the work being performed is required to comply with 521 CMR. In addition, an accessible public entrance and an accessible toilet room shall be provided. 5of6 Code Review Thomas Douglas Architects,Inc. Renovations to Thornes Marketplace 196 Pleasant Street,Suite 202 150 Main St. Northampton,MA 01060 Northampton,MA 413-585-0641 606 Structural: None proposed 607 Energy Conservation: See 711 below 701.3 Compliance New electrical equipment must comply with section 708 Length of dead end corridors, comply with 705.6 Minimum ceiling height of newly created habitable and occupied spaces shall be greater than 8 feet. OCCUPANCY Occupant Load Calculation Floor area per Max occupancy (1004.4.1) occupant based on 60 gross sf per person Cedar Chest 2° floor 60 Gross 94 M use Toilets: There are common toilets in the building within 300 feet. 704 Fire Protection: 704.2, 912.2a Automatic sprinkler systems Automatic sprinkler systems will be upgraded in the work area as needed. 705 Means of Egress The proposed work will include 3 means of egress. There will not be a reduction of means of egress in any part of the building. IBC Table ioi6.i Exit Access Travel Distance: For M use and sprinklers: 250 ft maximum allowable travel distance. The proposed travel distance is adequate to meet the code. IBC Table ioi8.i Corridor Fire Resistance Rating none IBC 10114.3 Common path of egress travel: 4of6 Code Review Thomas Douglas Architects,Inc. Renovations to Thornes Marketplace 196 Pleasant Street,Suite 202 150 Main St. Northampton,MA 01060 Northampton,MA 413-585-0641 Fire Resistive Required Types of Building Element Type 3B Construction,Table 6oi IBC Primary Structural o Frame Bearing walls, Exterior 2 Bearing walls, Interior o Nonbearing walls and o partitions, exterior Nonbearing walls and o partitions, interior Floor construction and o secondary members Roof construction and o secondary members Level i-work requirements: The removal and replacement or the covering of existing materials, elements, equipment or fixtures using new materials, elements, equipment or fixtures that serves the same purpose This Project will have new interior walls, doors,finishes and lighting. 602.1 Interior finishes:All newly installed wall and ceiling finishes shall comply with the IBC. Level 2 work requirements: The reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment. This Project will have new interior walls and exits. 603 Fire Protection: Alterations shall be done in a manner that maintains the level of fire protection provided. This Project will not affect the level of fire protection that is currently provided. 604 Means of Egress Repairs shall be made in a manner that maintains the level of protection provided for the means of egress. 3of6 Code Review Thomas Douglas Architects,Inc. Renovations to Thornes Marketplace 196 Pleasant Street,Suite 202 150 Main St. Northampton,MA 01060 Northampton,MA 413-585-0641 Areas Existing total building areas by floor: 1. Ground floor: 10,720 sf 2. Lower Level: 16,582 Sf 3. 1St floor: 16,440 sf 4. 2 nd floor: 16,522 Sf 5. ;rd floor: 16,522 Sf Total building: 76,876 sf Proposed work areas by use: Total proposed M work area: 5,669, sf Level 1 areas proposed: 4,156 sf Level 2 areas proposed: 1,513, sf Work area percentages Level 1 areas as a percentage of total building: 5% Level 2 areas as a percentage of total building: 2% Level 1 areas as a percentage of tenant space: '73% Level 2 areas as a percentage of tenant space: 27% The work area comprises less than 50%of aggregate area of the building; therefore this is not a level 3-alteration project. IEBC section 405) 704 Fire Protection:The building is fully sprinkled. There are sprinklers in the existing space. We are reconfiguring the sprinkler layout in the work area to conform to the new layout. There will be no modifications to the areas outside of the work area. 704.4 Fire alarm and detection: • The building has a fire alarm system in all areas. It will be maintained and altered as necessary in the work area. According to the IEBC this renovation is being reviewed as: Work Area Method, Chapter 4.Applicable Sections are: Chapter 6-Alterations Level 1- New finishes and fixtures Chapter 7-Alterations Level 2 - New construction. 2of6 Code Review Thomas Douglas Architects,Inc. Renovations to Thomes Marketplace 196 Pleasant Street,Suite 202 150 Main St. Northampton,MA 01060 Northampton,MA 413-585-0641 CODE REVIEW August 4, 2015 Thornes Marketplace Cedar Chest 2nd floor renovations (project#12-021) 150 Main Street Northampton, MA Applicable Building Code: MA 78o CMR Eighth Addition IBC, IEBC International EXISTING Building Code, 2009 ZONING DISTRICT: CB Proposed Renovations: Project Description: • Renovate the 2nd floor areas of Cedar Chest for continued use by the existing tenant. Use Groups • The space is an existing M use. • The proposed uses are M mercantile use. No change of use is proposed for the work areas. Existing separation of uses within the overall building: Table 5o8.4 (IBC) does not require a fire separation between M, S1, and B uses. • The current level of safety or sanitation will NOT be reduced and the portions altered shall conform to the requirements of the IBC, including interior finishes, interior floor finishes, and interior trim. Construction Type • 3B Valuation of Project: • This project's construction costs are: $85,000 • The assessed value of the building is: $3,854400 • The cost of the project is 2.21% of the assessed valuation of the total building. 1 of 6 Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute, an employee is defined as"...every person in the service of another under any contract of hire, express or implied,oral or written." An employer is defined as"an individual, partnership, association, corporation or other legal entity, or any two or more of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employer, or the receiver or trustee of an individual,partnership, association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein,or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152, §25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally, MGL chapter 152, §25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and, if necessary, supply sub-contractor(s) name(s), address(es)and phone number(s) along with their certificate(s) of insurance. Limited Liability Companies (LLC) or Limited Liability Partnerships (LLP)with no employees other than the members or partners, are not required to carry workers' compensation insurance. If an LLC or LLP does have employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy, please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant that must submit multiple permit/license applications in any given year, need only submit one affidavit indicating current policy information (if necessary) and under"Job Site Address" the applicant should write"all locations in (city or town)." A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e.a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address,telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 1 Congress Street, Suite 100 Boston, MA 02114-2017 Tel. # 617-727-4900 ext 7406 or 1-877-MASSAFE Fax# 617-727-7749 Revised 7-2013 www.rnass.gov/dia The Commonwealth of Massachusetts Department oflndustrialAccidents Office of Investigations a I Congress Street, Suite 100 r Boston, MA 02114-2017 www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Steve Ferrari, FCM Smart Build Address: 103 Ryan Road City/State/Zip: Florence, MA 01062 Phone 4:413-588-8975 Are you an employer?Check the appropriate box: Type of project(required): 1.❑ I am a employer with 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.X 1 am a sole proprietor or partner- listed on the attached sheet. 7. X Remodeling ship and have no employees These sub-contractors have g, ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.+ required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 11❑ Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. #Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: _ Policy#or Self-ins. Lic. #: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the D1A for insurance coverage verification. I do hereby certi under the pains and penalties of perjury that the information provided above is true and correct. Sign ature: Date: b l Phone#: 413-5/88-897 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6.Other Contact Person: Phone#: Versionl.7 Commercial Building Permit May 15,2000 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No SECTION 11 -OWNER AUTHORIZATION-TO BE COMPETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Richard Madowitz I, as Owner of the subject property hereby authorize Stephen Ferrari,, to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date Y as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of periury. Stephen Ferrari Print er 9-6- -15-- 08/06/2015 Signature of Owner/Agent Date SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Stephen Ferrari Name of License Holder: P_ . CS-98877 License Number 13 Ryan RD, Florence,MA 01062 05/23/2017 Aftefs Expiration Date (413) 588-8975 Si natuI6 Telephone r I -T- I SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No Version 1.7 Commercial Building Permit May 15,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116(CONTAINING MORE THAN 35,000 C.F.OF ENCLOSED SPACE) 9.1 Registered Architect: 196 Pleasant ST,Northampton, MA 01060 Not Applicable ❑ Name(Registrant): .196 Pleasant ST,Northampton,MA 01060 Registration Number Address (413) 585-0641 Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Reg, stration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor Thornes Marketplace,LLC Not Applicable ❑ Company Name: ,Stephen Ferrari Responsible In Charge of Construction 103 Ryan RD, Florence,MA Address (413) 588-8975 Signature Telephone Versionl.7 Commercial Building Permit May 15,2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R:'', , Rear Building Height Bldg.Square Footage Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES IF YES: enter Book Page, and/or Document#, B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: ,Front Building Sign D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15,2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑✓ Existing Wall Signs ❑ Demolition❑ Repairs❑ Additions ❑ Accessory Building❑ Exterior Alteration ❑ Existing Ground Sign❑ New Signs❑ Roofing❑ Change of Use❑ Other❑ Brief Description Minor demolition, construct new storefronts, install new display casework,new lighting,upgrade Of Proposed Work: ;fire sprinklers and alarms SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ 1A A-4 ❑ A-5 ❑ 1B ❑ B Business ❑ 2A ❑ E Educational ❑ 2B I ❑ F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ Institutional ❑ I-1 ❑ 1-2 ❑ 1-3 ❑ 3B M Mercantile 4 ❑ R Residential ❑ R-1 ❑ R-2 ❑ R-3 ❑ 5A ❑ S Storage ❑ S-1 ❑ S-2 ❑ 5B ❑ U Utility ❑ Specify: : M Mixed Use ❑ Specify: S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: Mercantile Proposed Use Group: Mercantile Existing Hazard Index 780 CMR 34): Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(sf) 1 S` 16,440 1 St 16,440 2nd 16,522' 2nd 16,522 3`d 16,522 3�d 16,522 r;A'O vNt>1--o— 10,720' ` 6A.0C11 D Ft w 10,720, Total Area(so 76,876 Total Proposed New Construction(so 76,876 Total Height(ft) 50 Total Height ft 50 7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public [D Private E] Zone Outside Flood Zone E] Municipal ✓❑ On site disposal system E3 Version-1.7 Commercial Building Permit May 15,2000 Dirpartment us on ty, �4 City of Northampton Status of Permit �F Building Department Cori7riueway; rmifi, _ ections c n�o�o 212 Main Street SewerISepticAvadabillty 3 Room 100 We*/tlllell Ayailab�il ! f Northampton, MA 01060 TWt of 5tructUral is Plens ,, f phone 413-587-1240 Fax 413-587-1272 C3IS�te t?iar)s ` k tither Specifyf 5 APPLICATION TO CONSTRUCT,REPAIR,RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR�TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office Cedar Chest, Second Floor-Thornes Marketplace Map Lot Unit 150 Main Street Zone Overlay District Northampton Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Thornes Marketplace,LLC 150 Main ST, Third Floor,Northampton,MA Name(Print) Current Mailing Address: ;(413) 582-9970 Signature Telephone 2.2 Authorized Agent: Steve Ferrari 103 Ryan RD, Florence,MA Name(Print) Current Mailing Address: ;(413) 588-8975 Signature Telephone SECTION 3-ESTI ATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building $54,500.00 (a)Building Permit Fee 2. Electrical $22,000.00 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) m 5. Fire Protection $8,500.00`, 6. Total=(1 +2+3+4+5) $85,000.00 Check Number Th Mcial Use Only Building Permit Number Date Issued Signature: Building Commissioner/Inspector of Buildings Date File#BP-2016-0158 APPLICANT/CONTACT PERSON STEPHEN FERRARI ADDRESS/PHONE 103 RYAN RD FLORENCE01062 (413) 588-8975 Q PROPERTY LOCATION 150 MAIN ST-CEDAR CHEST MAP 32C PARCEL 001 001 ZONE CB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Typeof Construction: MINOR DEMOLITION,NEW INT STOREFRONTS,NEW DISPLAY CASEWORK,LIGHTING,UPGRADE SPRINKLERS&ALARMS New Construction Non Structural interior renovations Addition to Existing Accessory Structure Buildine Plans Included: Owner/Statement or License 98877 3 sets of Plans/Plot Plan s THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF946MATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition ay 4721-_FXS i ur of Build' g O fici Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 150 MAIN ST-CEDAR CHEST BP-2016-0158 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 32C-001 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit# BP-2016-0158 Project# JS-2016-000264 Est. Cost: $85000.00 Fee: $595.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: STEPHEN FERRARI 98877 Lot Size(sq. ft.): 16683.48 Owner: THORNES MARKETPLACE LLC C/O HPMG Zoning: CB(1oo// Applicant: STEPHEN FERRARI AT. 150 MAIN ST - CEDAR CHEST Applicant Address: Phone: Insurance: 103 RYAN RD (413) 588-8975 O FLORENCEMA01062 ISSUED ON.811812015 0:00:00 TO PERFORM THE FOLLOWING WORK.MINOR DEMOLITION, NEW INT STOREFRONTS,NEW DISPLAY CASEWORK,LIGHTING,UPGRADE SPRINKLERS & ALARMS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 8/18/2015 0:00:00 $595.00 212 Main Street,Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner