Loading...
41-016 (14) Air Leakage Property Organization HERS Fierst Center for EcoTechnology Confirmed 1253 Westhampton Rd Unit 2 413-586-7350 8/13/14 Northampton , MA 01062 John Saveson Rating No:14-061 RaterID:1911963 Weather:Northampton, MA Builder 1253 Westhampton Rd Unit 2 Teagno Construction, Inc. 14-061 1253 Westhampton Rd Unit 2 Northampton final.big Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.22 0.16 ACH 50 Pascals 3.64 3.64 CFM 25 Pascals 255 255 CFM 50 Pascals 400 400 Eff. Leakage Area (sq.in) 22.0 22.0 Specific Leakage Area 0.00022 0.00022 ELA/100 sf shell (sq.in) 0.90 0.90 Duct Leakage Leakage to Outside Units minisplit CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 0 Eff. Leakage Area (sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0000 Ventilation Mechanical Exhaust Only Sensible Recovery Eff. (%) 0.0 Total Recovery Eff. (%) 0.0 Rate (cfm) 78 Hours/Day 6.8 Fan Watts 32.6 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, a minimum of 22 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 44 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate- Residential Energy Analysis and Rating Software 04.5.1 This information does not constitute any warranty of energy cost or savings. © 1985-2014 Architectural Energy Corporation, Boulder, Colorado. Certificate Registry ID 729394021 Home Energy Rating Rating Number 14-061 Certified Energy Rater John Saveson 1253 Westhampton Rd Unit 2 Rating Date 8/13/14 Northampton , MA 01062 Rating Ordered For Fierst Estimated Annual Energy Cost' Use MMBtu Cost Percent 5 Stars Plus Heating 8.1 $378 28% Confirmed HERS Index: 64 Cooling 1.1 $54 4% Hot Water 8.0 $377 28% Lights/Appliances 11.9 $560 41% General Information Photovoltaics -0.0 $-0 -0% Conditioned Area 704 sq. ft. House Type Single-family detached Service Charges $0 0% Conditioned Volume 6591 cubic ft. Foundation More than one type Total 29.1 $1369 100% Bedrooms 1 Criteria Mechanical Systems Features This home meets or exceeds the minimum criteria for the following: Air-source heat pump: Electric, Htg: 11.0 HSPF. Clg: 20.3 SEER. Heating: Electric baseboard or radiant, Electric, 100.0% EFF. Heating: Electric baseboard or radiant, Electric, 100.0% EFF. Duct Leakage to Outside 0.00 CFM25. Ventilation System Exhaust Only: 78 cfm, 32.6 watts. Programmable Thermostat Heat=Yes; Coot=Yes Building Shell Features Ceiling Flat NA Slab R-10.0 Edge, R-40.0 Under Sealed Attic NA Exposed Floor R-30.5 Vaulted Ceiling R-30.5 Window Type U-Value: 0.360, SHGC: 0.450 Green Home Services Above Grade Walls R-36.0 Infiltration Rate Htg: 400 Clg: 400 CFM50 Center for EcoTechnology Foundation Walls R-20.0 Method Blower door test 320 Riverside Drive, Suite 1A Lights and Appliance Features Florence, MA 01062 413-586-7350 Percent Interior Lighting 100.00 Range/Oven Fuel Electric 413-586-7351 Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric Refrigerator (kWh/yr) 655.00 Clothes Dryer EF 3.01 Dishwasher Energy Factor 0.46 Ceiling Fan (cfm/Watt) 0.00 REM/Rate- Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. © 1985-2014 Architectural Energy Corporation, Boulder, Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Air Leakage Property Organization HERS Fierst Center for EcoTechnology Confirmed 1253 Westhampton Rd 413-586-7350 10/28/14 Northampton, MA 01062 John Saveson Rating No:13-016 RaterID:1911963 Weather:Northampton, MA Builder 1253 Westhampton Rd Teagno Construction, Inc. 13-016 1253 Westhampton Rd final-Stretch Code.blg Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.14 0.10 ACH @ 50 Pascals 2.29 2.29 CFM @ 25 Pascals 797 797 CFM @ 50 Pascals 1251 1251 Eff. Leakage Area(sq.in) 68.7 68.7 Specific Leakage Area 0.00014 0.00014 ELA/100 sf shell(sq.in) 0.95 0.95 Duct Leakage Leakage to Outside Units coolin CFM @ 25 Pascals 132 CFM25/CFMfan 0.0802 CFM25/CFA 0.0377 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 207 Eff. Leakage Area(sq.in) 11.37 Thermal Efficiency N/A Total Dud Leakage Units CFM25/CFA i Total Duct Leakage 0.0377 j Ventilation Mechanical Balanced Sensible Recovery Eff. (%) 71.0 Total Recovery Eff. (%) 48.0 Rate (cfm) 115 Hours/Day 14.4 Fan Watts 102.0 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2-2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, a minimum of 65 cfm of mechanical ventilation must be provided continuously, 24 hours per day.Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 130 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate- Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2014 Architectural Energy Corporation, Boulder,Colorado. i Home Energy Rating Certificate Regiumber 13-016 14 Rating Number 13-016 Certified Energy Rater John Saveson 1253 Westhampton Rd Rating Date 10/28/14 Northampton, MA 01062 Rating Ordered For Fierst n ii Estimated Annual Energy Cost Use MMBtu Cost Percent 5 Stars Plus Heating 12.8 $600 21% Confirmed HERS Index• 61 Cooling 9.6 $449 15% Hot Water 7.8 $368 13% Lights/Appliances 31.5 $1483 51% General information Photovoltaics -0.0 $-0 -0% Conditioned Area 3499 sq. ft. House Type Single-family detached Service Charges $0 0% Conditioned Volume 32723 cubic ft. Foundation More than one type Total 61.7 $2900 100% Bedrooms 3 Criteria Mechanical Systems Features This home meets or exceeds the minimum criteria for the following: Water Heating: Conventional, Electric, 0.91 EF, 80.0 Gal. Ground-source heat pump: Electric, Htg: 3.1 COP. Clg: 15.1 EER,w/DSH. Duct Leakage to Outside 132.00 CFM25. Ventilation System Balanced: ERV, 115 cfm, 102.0 watts. Programmable Thermostat Heat=No; Cool=Yes Building Shell Features Ceiling Flat R-59.3 Slab R-0.0 Edge, R-20.0 Under Sealed Attic NA Exposed Floor NA Vaulted Ceiling NA Window Type U-Value: 0.240, SHGC: 0.560 Green Home Services Above Grade Walls R-35.0 Infiltration Rate Htg: 1251 Clg: 1251 CFM50 Center for EcoTechnology Foundation Walls R-12.0 Method Blower door test 320 Riverside Drive, Suite 1A Lights and Appliance Features Florence,MA 01062 413-586-7350 Percent Interior Lighting 0.00 Range/Oven Fuel Electric 413-586-7351 Percent Garage Lighting 0.00 Clothes Dryer Fuel Electric Refrigerator(kWh/yr) 571.00 Clothes Dryer EF 3.01 Dishwasher Energy Factor 0.00 Ceiling Fan (cfm/Watt) 0.00 REM/Rate-Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. 0 1985-2014 Architectural Energy Corporation, Boulder,Colorado. The Home Energy Rating Standard Disclosure for this home is available from the rating provider. The Commonwealth of Massachusetts , . t` City of Northampton Certificate 2L Occupancy ^� In accordance with 780 CMR, Section 5120.3 (The Eight Edition of the Massachusetts State Building Code, Single and Two Family Dwellings) this Certificate of Occupancy is issued to the premise or structure or part thereof as herein identified. Identify Name of Building of Space Within Certificate No. Issued to Tea no Construction Demo BP-2013-1222 g Found BP-2013-1254 House BP-2014-1255 Unit#2 BP-2014-0133 Identify property address including street number, name, city or town and county Located at 1253 Westhampton Road Northampton, Hampshire, Massachusetts Use Group T� HERS Classification(s) Single Family House 5B-R3 61 house with Detached Accessory Unit 64 unit #2 This Certificate of Occupancy is hereby issued by the undersigned to certify that the premise,structure or portion thereof as herein specified has been inspected for general fire and life safety features. This certificate shall allow for the temporary use as herein described and in conformance with any and all conditions as identified below. It shall be posted in a conspicuous place within the space as directed by the undersigned. Failure to post the certificate,failure to comply With conditions or, tampering with the contents of the certificate is strictly prohibited. Conditions of Use Satety and Structural Systems must be maintained. Name of Municipal Date of Map/Plot: Building Official Charles Miller Inspection 4/6/2015 Signature of Municipal 7 Date of 041-016 Building Official Issuance 4/6/2015 G4p Tmnmm=,val#4 of Mansarlpmr m DEPARTMENT OF PUBLIC SAFETY—DIVISION OF FIRE PREVENTION 1010 COMMONWEALTH AVENUE. BOSTON r i �~ 1011'1'HANIPTON LIQUEFIED PETROLEUM GAS . . . . . . . . . . . . . (City or Towni ( ate) c;.y^V, PERMIT eln��c� CHAPTER 148, & CODE OF MASS. 527 C.M.R. 6.00 This permit is granted on the basis that the Liquefied Petroleum Gas will be stored in accordance with the Rules and Regulations of the Department of Public Safety, Chapter 148 Sections, 9, 10, & 2``8�� a 52 - C.M.R. 6nn0��0 (lI./. /- Location of Property . . .�>Z '. Location: . Owner of Property . . .L U6: . . . ! . . . . . . . . . . . . . Installer !'�� � � . ! ' ��``� �� ID ot No. Tanks . �. . Capacity/046;( '' Pounds . . . . . . . . . . Address: � Inspection completed on . 411."' . . . . . . .ib./'. By. . . .�.`l/�C�,r}�S. . . . . . . . . . . r (Fire Inspector) Fee . . . . (148 Sec. 10A) Fire Chief . . .BRIAN P. DUGGAN �� !/ ,j `/ � J Northampton Fire Department ( Property Owner ) 42 1253 WESTHAMPTON RD BP-2013-1254 cls;�: COMMONWEALTH OF MASSACHUSETTS �,a :Block: 41 -016 CITE' OF NORTHAMPTON Lot: -001 Permit: Building C.atego.ry: FOUNDATION BUILDING PERMIT Permit 4 BP-2013-1254 Proiect# JS-2013-002010 Est. Cost: Fee: $554.40 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor., License: L)se Grqll Li.__ TEAGNO CONSTRUCTION INC 034716 Lot Size(sq.ft.): 2147508.00 Owner. FIERSAT FREDERICK U&EVA C a-i���aiJ!'fi Pt•:. 3 E!'\vigil./ CV.`iiaJ i RVV t ION INC AT. 1253 WESTHAMPTON RD Applicant Address: Phone: Insurance: 228 TRIANGLE ST _ V_ 413 549-0803 Workers Compensa,ion AMHERSTMA01002 ISSUED ON:7 1812013 0:00:00 TO PERFORM THE FOLLOWING WORK.-CONSTRUCT FOUNDATION ONLY (SFH/ATT GARAGE) POST THIS CARD SO IT IS VISIBLE FROM THE STREET' Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Undergrounad: Service: Meter: Footings: Rough: Rough: House# Foun ation: e lC� (/ Driveway Final: l .�I�-ti3 pr0.� �/ LAk%1 Final: Final: J7 � Rough Frande: Cas: Fire DeaartRnent Fireplace/Chimney: Rough: Oil: Insulation:it 'Filial: Smoke: Final:6 7l T KIS PERMIT MAY BE REVOKED BY THE CITY OF RTHAMPTON UPON VIOLATION OIL :1,,NY OF ITS RULES AND 'e tifiicate of Occu a v atui. ZZ'tj Ftjvp(:t. I)atc Paid: Amount: Building 7/8/2013 0:00:00 $554.40 212 Main Street, 04,(.ne(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck-Building Corn.Yiissioner nA, 1253 WESTHAMPTON RD 04 BP-2014-0133 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:41 -016 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: demolition BUILDING PERMIT Permit# BP-2014-0133 Project# JS-2013-002010 Est.Cost: $900000.00 Fee: $1223.60 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: TEAGNO CONSTRUCTION INC 82248 Lot Size(sq. ft.): 2147508.00 Owner: FIERST FREDERICK U&EVA C Zoning: Applicant: TEAGNO CONSTRUCTION INC AT: 1253 WESTHAMPTON RD Applicant Address: Phone: Insurance: 228 TRIANGLE ST (413) 549-0803 Workers Compensation AMHERSTMA01002 ISSUED ON:811412013 0:00:00 TO PERFORM THE FOLLOWING WORK.-CONSTRUCT SFH WATT GARAGE/DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET il ea 1tflT //- Inspector of Plumbing Inspector of Wiring G/J D.P.W. Building Inspector � j= i- 1 lc�p Underground: Service: u} wH I S Meter: 0 J � i r/ Footings: � Rough: -� Rough: House# Foundation: I(�' ' a e�i Driveway Final: O,- Final:/� �' fT / Final: C1 Rough Frame- oK Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED-IM THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND �� �� • tt,�jy Certificate of Occu anc Signature: ` FeeType: Date Paid: Amount: X0 Building 8/14/2013 0:00:00 $1223.60 212 Main Street,Pone(413)587-1240,Fax: (413)587-1272 Louis Hu rouck—Building Commissioner