28-021 (5) CITY OF NORTHAMPTON BOARD OF PUBLIC WORKS
SANITARY SEWER FORCE MAIN POLICY
The purpose of this policy is to establish the quidelines, procedures, specifications and conditions
associated with sanitary sewer force mains that will become the responsibility of the Department
of Public Works (DPW). The following conditions shall apply:
1. All information associated with the entire force main system shall be submitted by the
applicant to the DPW for approval. The information shall include, but not be limited to,
technical specifications of every system component, capacity of system, operation of
valves, pumps and other controlling mechanisms, installation procedures and detailed
testing protocols.
2. If the force main system is part of a proposed subdivision, its installation and inspection
shall conform to the City' Subdivision Rules and Regulations in addition to the
conditions stated in this policy. In all other cases, its installation and inspection shall
conform to applicable Rules and Regulations of the DPW in addition to the conditions of
this policy.
3. Force main systems shall be designed so that individual pump chambers shall be located
outside the street layout. Curb stops and check valves shall be installed at the property
line.
4. No connection to the common force main system shall be allowed unless a "Municipal
Sewer Availability" and "Residential or Commercial Building Sewer Application" are
submitted and approved by the DPW. Attached to these documents shall be the
technical specifications, manufacturer's name, model and rated capacity of the proposed
pumping system.
5. Prior to the replacement or upgrade of any existing pumping system, the information
requested in Item 4 above must be submitted to the DPW for approval.
6. Pumping chambers on private property shall be accessible at all times. The DPW has the
right to enter said property at any time for the purpose of examining the pumping station
for compliance with the regulations stated in this policy. The DPW will not be
responsible for damage to any plantings or landscaping placed over or in close proximity
to the pumping chamber access.
7. A red light indicating system problems/failure shall be installed outside every structure
connected to the force main system. Said light shall be clearly visible from a vehicle
traveling on the adjacent roadway.
8. It is the responsibility of every owner of a property/structure that is connected to the
common force main to insure that all components of their service line are functioning
properly and in accordance with the approved submittals.
9. Any violation to this policy may cause the service line of the structure in question to be
shut-off at the curb stop. In addition, if the violation causes damages to either the
common force main or to adjacent structures connected to the system, the responsible
party shall bear the cost of all repairs and claims associated with said violation.
10. The DPW will become responsible only for the components of a sanitary force main
system located within the layout of a City accepted street. Acceptance of a street can
only be approved by the Northampton City Council.
Adopted by the Board of Public Works on May 14, 2003.
C:\Policies\SanitaryForceMainsApril2003
• yr.
'y '"WHITMAN- HOWARD INC. .
Standard Tie .Form
A Pb�
Y _
= � 44 . cpcv,5
- : •` -;'Y. _ j - - jot --.i
;Client p Job- No.ff-ISIS
Descriptaono.. , nstAl at on 6 A t/
of Valve OL OR
F-_
opy to,,'Cli.ent office File
Datew� r'``�r Bye
e O server
MUNICIPAL SEWER AVAILABILITY
Northampton Streets Department
125 Locust Street Luu3 y
Northampton, MA 01060
587-1 570 ,.___,._
Location: 690 Ryan Road
Inquiry Made By: Carol Heon, Realtor 413-586-0946
Date of Inquiry: May 27, 2003
Municipal Sewer Main in Front of Location: Yes R No
Size of Sewer Main: 8" Material: C Age:
Depth of Sewer Main: @ 5.5'
Size of Service Connection: 6"
Comments: On Whitman & Howard swing tie .cards
A corresponding"sewer entrance fee"shall be paid prior to making any connection to the municipal
sewer system. Arrangements of such installation shall be made with the Northampton Streets
Department with a minimum of 5 working days notification.All work shall conform to Northampton
Streets Department specifications.
Joseph T as, Superintendent
Streets Department
cc: Ned Huntley, Asst. City Engineer
Anthony Patillo, Building Inspector