Loading...
17B-007 DOOR SCHEDULE Key MAKE MODEL STYLE SIZE TYPE ROUGH OPENING JAMB LOCKSET REMARKS 1 3068 RH 3'-1 'h"x 6'-101h" 6 9/16" Deadbolt Front door 2 2868 RH 2'-10 W'x 6'-10'h" 4 9/16" Privacy 1 hour rated 3 2868 LH 2'-101h"x 6'-101h" v.i.f. Passage 4 4068 Bi-pass 4'-11/4"x6'-10'h" 4 9/16" 5 2668 LH 2'-8'h"x6'-10'h" 4 9116" Passage 6 Integrity ISFD 6068 XO 6068 Sliding 6'-0"x 6'-10'h" 6 9/16" Wood-Ultrex French Door 7 1468 RH 1'-6 1h"x 6'-10'h" 4 9/16" Passage 8 2068 LH 2'-2'h"x6'-10'h" 4 9/16" Passage 9 3068 Pocket frame 6'-1 1/4"x 7'-01/4" 4 9/16" 10 21068 Pocket frame 5'-91/4"x 7'-01/4" 4 9/16" 11 4068 Pair 4'-2 3/8"x6'-10'h" 4 9/16" Passage 12 4068 Pair 4'-2 3/8"x6'-10'h" 4 9/16" Passage 13 14 15 WINDOW SCHEDULE Key MAKE Model Type Rough Opening Header Head HT. Remarks QTY A Integrity Wood-Ultrex ITDH 3460 Double Hung 2'-10'x4"x 5'-01/4" 2-2x8 6'-10'h" 6/1 2 B Integrity Wood-Ultrex !AWN 2927 Awning 2'-5"x2'-3 5/8" 2-2x8 6'-101h' 6 lite 2 C Integrity Wood-Ultrex ITDHTR 3416 Transom 2'-10'h"x 1'-41/4" 2-2x8 8'-6'h" 3 lite 2 D Integrity Wood-Ultrex 1CA 2539 Casement 2'-1"x 3'-3 5/8" 2-2x8 6'-10'h" 6 lite 2 E Integrity Wood-Ultrex ITDH 3056 Double Hung 2'-61h"x 4'-81/4" 2-2x8 6'-10'h" 6/1 2 F Integrity Wood-Ultrex !(-A 2539 2W Casement,pair 4'-1"x 3'-3 5/8" 2-2x10 6'-10'h" 6 lite 1 G Integrity Wood-Ultrex ICATR 2516 Transom 2'-1"x 1'-41/4" 2-2x8 8'-6'h" 2 lite 2 H Integrity Wood-Ultrex ISPDG 7216 Transom 6'-0"x 1'-41/4" 2-2x10 8'-61h" 6 lite 1 I Integrity Wood-Ultrex IAWN 3727 Awning 3'-1"x 2'-3 5/8" 2-2x8 8'-6'h" 6 lite 1 J Integrity Wood-Ultrex IAWN 3727-2W Awning,pair 6'-1"x 2'-3 5/8" 2-2x10 8'-6'h" 6 lite 1 3 K Basement/utility ti i Q I I I hiP l2 d t tZ+¢C-T�f Sc•aT i i LLJ — — i i1 1 74 4`7 1NtzSa N0 .+ n -}-- Cs c-Q c,at:l is 7 av c-> _ �� 1- - 1'+'Q°�i 1 rs4 t 9 R Y, t I T ? -6 QQ"IIA Q 6n$ IIIE. 21 I zl � F �-4,gam S ... r� , , s >, g off-- --- --- _ _ � I 1� Ck i t?. it �i ��� V E 5�r2~ __. _ i2�`�� �✓r 4 3-1��i 3`-lam 2- --- 13'-2_ :; = ,4 �,�2.. IS S IZ Qq - - � { 2 SaNb�ra�-s D / k T,4 C, �. ewe) L e flit meAjF J C C'n �, � -� of Z R-►c�tc> �r�su�, 1 V 401 J dlr� Gw�SIF�c� SzaN�;,� Go I _mss rt=e S> � r / yydl m a �J X � ot ufl L � 1 � ct " V �c \ 7, F s K o 4z, w gii, � y w t a ;0;. ft �' a t So s\ K b `°" y"ae ewe'•'7 \ - - g, ,_6 .�•�a k",NINE, k � M5, 3, •� b Cc - 5 f $$$$ \'4 k x �` � ,�.':• � t �.i. �x� x .cn, �\\�'T'• � � �� � fix.• . .�\�.. '\ h.s •?fix_ \ ? � _f "£'T i L s � n: \ •��s'3/ F a l � ' w � ,r. �! ���..�,x✓/r - \\ '. V tax ���� .y �a # � i•<; z ���\� `hut v �y � 39. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note:Thrul-oks are engineered for post attachment supporting a railing. Lateral attachment is required for each deck per section 502.2.2.3. 40. Smoke and CO detectors as required. 780 CMR R314 and R315. a. Smokes in each bedroom,within 10' of a bedroom door, and at the bottom of a stair leading to a finished floor above. b. CO within 10'of bedroom doors, at each level,for every 1500 sqft, (plumbing code in the mechanical room) Except if there are no fossil burning fuels. c. Heat detector in attached garage, and other large unfinished unconditioned spaces. 41. Closets beneath stair which have doors must be drywalled with%2". 780 CMR R302.7 42. If there is mechanical equipment or a combustible roof, 30 sqft of space, and 30 measured from top of ceiling joist to bottom of rafters an attic access of minimum RO of 22" x 30" is required to be located in an accessible place. It must be insulated,gasketed, and secured in place. Relevant items must be submitted to the building department for approvals before inspections and or Certificates of Occupancy can be issued. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday,8:30 am to 4:30 pm,excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller(a-)northamptonma.Aov Thank you for your cooperation on these matters. uc Miller City of Northampton Assistant Commissioner and Zoning Enforcement 24. Floor joist systems that are not equal to 1%2' nominal dimension must be covered with%2' drywall or 5/8" wood structural panel or equivalent with some exceptions. 780 CMR R501.3 25. Educate the plumber and electrician about maximum notch and hole sizes, and placement.780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40%of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60%of a stud no closer than 5/8 to the edge, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom or to any other hole. Notches are different. 26. Drilling or notching of more than 50%of the wall plate width of an exterior wall or load bearing partition requires a 16 GA 1%2" strap across the area and 6" beyond each side with 8- 10nd nails. 780 CMR R602.6.1 27. Dryer ducts must terminate outside of the building, have a backdraft damper, cannot include a screen, and require 3' clearance from windows.780 CMR M1502.3 28. Dryer duct transition is limited to 8' of aluminum flex, must be exposed, and the proper UL listing.780 CMR M1502.4.3 29. Dryer duct maximum equivalent length is 25' less 5' per 901 elbow or per manufacturer's specs.780 CMR M1502.4.4.1, no screwed connections. 30. Dryer ducts when concealed must have a permanent label or tag within 6' of the duct connection 780 CMR M1502.4.5 31. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 32. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5'from the duct outlet for all fireplaces and airtight doors. 2009 IECC 402.4.3 33. Fire and draft stopping shall be completed before rough inspection.Typical locations,top (ceiling) and bottom (floor) plates, soffits, and every 10' within enclosed cavities. 780 CMR R302. 34. Ignition barriers are required over all thermal plastics and must be in place before final. 780 CMR R316. 35. Dwelling/Garage fire separation.An attached garage (within 3' of main structure) is required to have%" drywall on the garage side of the separation wall and if there is a finished space above the garage all walls must have%" drywall and the ceiling 5/8" drywall. 780 CMR R302.6 36. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. A signed copy of the Thermal Bypass Checklist. d. Energy information including mechanical equipment posted on the electric panel. e. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Windows and the Thermal Bypass Checklist. Duct blast testing when practicable. f. All band joist insulation must be enclosed within an air tight cavity, which you must create. 37. Vapor retarders.Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier.An air barrier is intended to stop air flow(convection)a vapor retarder or barrier is intended to stop molecular moisture transfer(diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99%of the moisture in a structure.This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 38. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 10. Ceiling joist are intended to prevent spread,once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8-16nd common are required at each connection. 780 CMR R802.3.1. When there is neither of these a structural ridge is required with a load path to the foundation. 11. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3rd 780 CMR R802.3.1 12. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 13. A complete window and header schedule is required.780 CMR Table R502.5 for header sizing and number of jack studs required. 14. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. 1-joist and or Floor Truss c. Roof truss 15. All I-Joist need to be protected from fire with%drywall or 5/8 wood structural panel. (R501.3) 16. A braced wall plan identifying appropriate braced wall areas where required (R301.1) and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. c. When using PFH (R602.10.3.3)or PFG (R602.10.3.4)the nailing requirement is 4" and 3" respectively using 8d common nails or galvanized box nails. PNEUMATIC nails must be full headed with the temper and shank sizing meeting the strict code requirement. 17. When nailing sheathing make sure your pneumatic nailers' pressure is properly set. Nails set too deep perforate the sheathing weakening it and contribute to building damage in high wind events. 18. Ceiling heights minimum 7'for habitable spaces, 6'8"for bathrooms includes tub/shower area if a shower head is used,6'8" for basements, 6'4" at beams/ducts.780 CMR R305.1. MA amended 19. Hazardous glazing locations,within 24 of a door,or within 60" of a stair,or across from hot tubs,spas, bathtubs within 60" if not 60" above the walking surface, and other locations.780 CMR R308.4 20. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 21. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44 of floor, DH 3.3 sqft min window size, Casement 20"x41" exception 5 sgft at 15t floor. Minimum clear opening 20"x24" or 24"x20".780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees,one 32" and one 28" minimum 78" high.780 CMR R311.2 d. Landing at each door 36 out and the width of the door minimum 36", maximum step 7 3/" from the top of the threshold and only in-swinging doors.780 CMR R311.3 22. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9", maximum riser 8%", maximum overall variance for the run is 3/8",4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception,4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 V minimum and 2" maximum rail, height minimum 34" maximum 38", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. Rails must be continuous and returned to the wall if not to newel post. 780 CMR R311.7. 23. Guards 36 minimum height above walking surface,a bench is a walking surface, required for more than 30" above floor or grade within 36",4" sphere rule.780 CMR R312.1. City of Northampton � s Massachusetts ` . DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building aka Northampton, MA 01060 mss . ti� INSPECTOR Maureen Speight July 28, 2014 448 Bridge Road Northampton, MA 01060 Subject Location:448 Bridge Road Map Block: 17B-007 Ms.Speight, Your building permit application dated 7-01-14 and plans dated 6-12-14 with SKs have been approved as drawn and per this memo.All work must meet all applicable codes whether noted or not included within this memo. Please follow up on the following items: These items will need to be accomplished as the project moves forward and before rough inspections; 1. An affidavit for an accessory apartment must be recorded and proof of recoding returned to the building department. 2. An initial and final HERS rating is required. 3. Ceiling joist to be 2x10 16" OC. Rafters to be 2x8 16" OC. Collar ties 2x4 48" OC min. 2x10 Ridge. 4. 2 -2x12 below the left kitchen wall across the entire basement. 5. There must be an emergency escape out of the basement. Window meeting requirements or bulkhead. 6. An attic access is required if 3' above and 30 sqft,22" x 30" insulated and gasketed. Note:July 1 begins enforcement of the 2012 IECC with MA amendments and fire protection for non- dimensional lumber floor system frames,the new Stretch Code is pending. As of August 4th 2011 the 81h Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not intended to be comprehensive, nor is it a substitute for purchasing and reading the MA codes. Read only international codes are available on line at.http://publicecodes.cyberregs.com/icod/­one must also consider the MA amendments to these codes which can be found at www.mass.gov/dps/`bbr The current relevant building codes are: 2009 IBC, 2009 IEBC,2009 IMC,2009 IRC, 2009 or 2012 IECC,AA115, MA amendments. 1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required.780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils(table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Through wall form ties must be removed from both faces and patched with hydraulic cement.780 CMR R406.2 of amendments. 6. Foundation anchor bolts must be%" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 7. CMU foundations require 3/8" parging before damp proofing.780 CMR R406.1 see exceptions. 8. Emergency escape is required out of every basement whether habitable or not.780 CMR R310.1 9. Crawl spaces can be treated in three different ways,vented (poor idea),exhausted (similar to exhaust only systems), or treating the space with supply and return. See 780 CMR R408 ENERGY EFFICIENCY PLAN 7 2. Preliminary Home Energy Rating Results Based on the assumptions described above, we have calculated the following Preliminary Home Energy Rating results. Preliminary HERS Index: 66 Preliminary Improvement Over 2014 Mass. Reference Home v2: 28.4% -Tier I* Note that Confirmed Home Energy Rating results may vary from the Preliminary Home Energy Rating results due to changes in building plans, energy features installed in the home, RESNET standards, software changes, and other factors. 3. Services Requested CET will provide a Confirmed Home Energy Rating for the purpose(s) indicated below. CET will charge fees for these activities based on your Home Energy Rating Services Agreement. • Stretch Energy Code compliance • Incentives for the Mass Save Residential New Construction program—Tier I* *= Mass Save Residential New Construction requirements and incentive amounts can change at any time without notice at the discretion of program sponsors. We anticipate, but do not guarantee, that current program requirements and incentive amounts will apply to this project as long as it is completed and inspected by November 30, 2015. As part of these services, CET will verify that your home meets all the requirements of these programs. I have reviewed and understand this Energy Efficiency Plan. I have reviewed the assumptions in part 1 and confirm that the assumptions are correct. Signature: Date: Printed Name: Company: Preliminary Rater:Jamie Callan Date: 712212014 Job#: 14-112 Page 2 of 2-Please send signed form to the Center for EcoTechnology Tel(413)586-7350 ext.242-Fax(413)586-7351 -greenhomeacetonline.orq ENERGY EFFICIENCY PLAN Project Address: 448 Bridge Rd, Northampton, MA 01062 Conditioned Floor Area 998 ft Volume 16200 ft Building Type Single family detached/in-law Bedrooms 1 1.Assumptions for Preliminary Home Energy Rating CET has completed a Preliminary Home Energy Rating with the following assumptions: a) The construction plans you have provided are accurate, including window dimensions and locations. b) Energy features not listed below in part c will meet the prescriptive requirements of the IECC 2009. c) The home will be built to incorporate the following energy features: Buiidmq Envelope „ Specifications Used in Analysis Slab Floor 1" EPS (R-4) insulation at edge 2" EPS R-8 insulation underneath Exterior Walls R19 Dense-Pack Cellulose 5.5" Grade 1 Windows &Glass Doors U-value= 0.29 SHGC = 0.52 Exterior Doors Wood R-2.5/U-0.40 Ceilings R67 18" Cellulose/2"x4" bottom chord 24" O.C. Blower Door Test' 3 ACH50 or better" Sections 3 &5 of the Thermal Enclosure Meet all Checklist Requirements as verified by a HERS rater at pre- Checklist drywall and final inspection The 2009 IECC requires a blower door test result of 7 ACH50 or lower. The number listed here requires significant improvements in air sealing beyond the base energy code. Mechanical Systems Specifications Used in Analysis Heating Equipment 95%AFUE Combination Boiler or better Water Heating Equipment 0.95 EF on demand water heater(Combination boiler) Whole House Ventilation Continuously operating exhaust fan <1.5 sones 30 CFM, 25 watts or less Lichting&Appliances Specifications Used in Analysis Lighting. 80% CFL, LED, or in-based fluorescent Refrigerator ENERGY STAR rated (if installed) Dishwasher ENERGY STAR rated (if installed) FF Gxtv III 'wari4ca11r� tffn f w F � � �lblassaz�useffs DEPARTMENT OF BUILDING INSPECTIONS � 212 Main Street • Municipal Building INSPECTOR Northampton,MA 01060 LOCATION /�/ ' L SQUARE FOOTAGE AMOUNT BASEMENT @ -20 l lsr FLOOR @.50, qob ! 50 2ND FLR @.30. . FLOORS, FINISH ATTIC,GARAGE(g.20 DECK/TORCHES @ .20 33'k TOTAL. /H48 15 5 City of Northampton Massachusetts tiSS t DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building �. Northampton, MA 01060 ss� �♦���, INSPECTOR Louis Hasbrouck Chuck Miller Building Commissioner Assistant Commissioner HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner" as, " Person(s) who owns a parcel on which he/she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two- year period shall not be considered a home owner." The building department for the City of Northampton wants any person(s)who seek to use the home owner exemption, to act as their own construction supervisor, to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the building department be called to inspect work at various stages, which include foundation/footings (before backfill) sonotube holes (before pour) a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection The building department requires these inspections before the work is concealed, failure to secure these inspections can result in failure to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to perform work (electrical, plumbing & gas) the homeowner will be responsible to make sure that the trades hired secure their proper permits in conjunction to the building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made 1. understand the above. (Home owner/resident's si ature questing exemption) I will call to schedule all required building inspections necessary for the building permit issued to me. Date ZY Address of work location �S The Commonwealth of Massachusetts • y Department of Industrial Accidents Office of Investigations _ 600 Washington Street Boston, MA 02111 ti www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Address: City/State/Zip: Phone #: Are you an employer? Check the appropriate box: Type of project (required): 1.❑ I am a employer with 4. ❑ I am a general contractor and I 6 ❑ New construction employees (full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' 9 ❑ Building addition [No workers' comp. insurance comp. insurance.1 5. ❑ We are:a corporation and its 10.❑ Electrical repairs or additions required.] 3.El required.] a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4), and we have no employees. [No workers' 13.❑ Other comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. tHo meowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Policy#or Self-ins. Lic. #: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. r i Zna atur Date: U Phone# Z/// ° x .6—/6.9 Official use only. Do not write in this area, to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable £ Name of License Holder: License Number Address Expiration Date Signature Telephone 9.Registered Home ImpiovemenYContractor Not Applicable £ Company Name Registration Number Address Expiration Date Telephone SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... £ No...... £ 11. -Home Owner Exemption. The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this pen-nit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Z ing Laws and State of Ma achusetts General Laws Annotated. Homeowner Signature, SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition Replacement Windows Alteration(s) Roofing Or Doors EJ Accessory Bldg. Ee Demolition ❑ New Signs [O] Decks [Q Siding [O] Other[o] Brief Description of Proposed Work: ";icLL lJ!/S Q TL' �/C SSta 2 y i ✓'/�7t17e,c1� Alteration of existing bedroom Yes �o Adding new bedroom Yes '�N0 Attached Narrative Renovating unfinished basement Yes Plans Attached Roll -Sheet sa. if New house and-or addition to`existing housing; complete the following': a. Use of building:One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms / c. Is there a garage attached? c+v �y d. Proposed Square footage of new construction. 3 Dimensions k e. Number of stories? f. Method of heating? "fit$ Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes y No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer 11� Private well City water Supply % SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1 as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date 1 ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. gPrinf e �oe of Owner/Agent 17 Date ' Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Setbacks Front Rear Building Height Bldg. Square Footage % q&j'tJ1- Open Space Footage % (Lot area minus bldg&paved #of Parking Spaces (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON7KNOV YES 0 IF YES, dateissueUd / IF YES: Was the permit recorded at the Registry ofDeeds? NO UU0 | xnu� ,c, ' Page and/or Document# IF YES: enter Book ag B. Does the site contain a brook, body of water orwetlands? NO DONTKNOW 0 YES 0 IF YES, has permit been or need to be obtained from the Conservation Commission? Needs to be obtained «—\ Obtained «�� , Date Issued: �� �� C. Do any signs exist on the property? YES 0 NO Ila` IF YES, describe size, type and location: D. Are there any proposed changes to oraddi�onsuf signs intended for the property YES 0 NO ��� IF YES, describe size, type and location: ' ' L___-_--------------------.....................---- ........ -----� E. Will the construction activity disturb(clearing,gradingexcavation, or filling)over 1 acre orioit part ofa common plan ' that will disturb over 1acre? YES � } NO IF YES,then a Northampton Storm Water Management Permit from the DPW ia required. ^ — 'S Departr�leht use onix ---- City of Northampton Sfatus of Permit ' Building Department Gtrrta Gtit/Drl�reway Permt#i ` �, 212 Main Street SewerlSepticavalCabllity Qi Room 100 Water/UktellAvatlatilhty JUL `"'1N rthampton, MA 01060 Twa Sets ofStru urai Plarf$ �— � -587-1240 Fax 413-587-1272 Plo#/Site Plans ' 1 Electric P tt� 01060 Other Specify`' APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office Lot Unit j Ax?l ! / Overla D�sfr►ct Y � � � � �� Elm St.District CB District SECTION 2 PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: � 1 Name(Print) Current Mail dress: Telephone / Signature 2.2 Authorized Agent: Name(Print) Current Mailing Address: Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS. Item Estimated Cost(Dollars)to be Official Use Only completed by ermit applicant 1. Building (a) Building Permit Fee L V, Li 2. Electrical (b) Estimated Total Post of Construction from 6 3. Plumbing � J— Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+3+4+5) ��� Check Number This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date ®r� File#BP-2015-0007 APPLICANT/CONTACT PERSON SPEIGHT MAUREEN M r ADDRESS/PHONE 448 BRIDGE RD NORTHAMPTON (413)204-5169 Q PROPERTY LOCATION 448 BRIDGE RD MAP 17B PARCEL 007 001 ZONE RI(100)/RR(100)/ THIS SECTION FOR OFFICIAL USE ONLY: D PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out Fee Paid Tyneof Construction:_CONSTRUCT ADDITION FOR ACCESSORY APARTMENT&ADD LAUNDRY ROOM TO EXISTING HOUSE New Construction Non Structural interior renovations Addition to Existing, Accessory Structure Building Plans Included: Owner/Statement or License 3 sets of Plans/Plot Plan THE FOL WING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: ��x proved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management De olition De Signa ure of Build' g fficial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. 448 BRIDGE RD BP-2015-0007 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17B-007 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category' ACCESSORY APARTMENT BUILDING PERMIT Permit# BP-2015-0007 Project# JS-2015-000013 Est.Cost: $102755.00 Fee: $663.60 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: Homeowner as Contractor Lot Size(sq.ft.): 67953.60 Owner: SPEIGHT MAUREEN M zoning: RI(100)/RR(100)/ Applicant. SPEIGHT MAUREEN M AT. 448 BRIDGE RD Applicant Address: Phone: Insurance: 448 BRIDGE RD (413) 204-5169 O NORTHAMPTONMA01060 ISSUED ON:712912014 0:00:00 TO PERFORM THE FOLLOWING WORK.-CONSTRUCT ADDITION FOR ACCESSORY APARTMENT &ADD LAUNDRY ROOM TO EXISTING HOUSE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType• Date Paid: Amount: Building 7/29/2014 0:00:00 $663.60 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner