25C-030 (10) FF'011 LYHH -JECII-ESSER C.PBEi PHONE t,U, - 1 41-3, 569 0662 J,3n, 24 12000 02: 1_7pf" F3
0
DUCT CONSTRUCTION
-
I 1 All ducts must be sealed with mastic and fibrous backing tape .
Pressure-sensitive tape may be used for fibrous ducts . Z`ie HVAC
system must provide a means for balancing air and water systeris .
TEMPERATURE CONTROLS :
Thermostats are required for each Separate HVAC system. A ma_rnaal
or automatic means to partially restrict or sb-uL off the heating
and/or cooling input to each zone or floor shall be provide('_5 .
RVAC EQUIPMENT SIZING:
Rated output capacity of the heating/cooling system is
not greater than 125k of the design load as specified,
in sections 780CMR 1310 and J4 ,4 .
MISC REQUIREMENTS:
Refer to 780 CMR, Appendix J for requirements relating :o swiamtinq
pools, HVAC piping conveying fluids above 120 F or chi"led fl�ji_Js
below 55 F, and circulating hot water systems ,
-----NOTES TO FIELD (Building Department Use
FROH : LYNN DECHESSER CPBD PH01,1E [10. 1 413 569 0612 jat-i. 2000 C2:22,JF-t' F`2'
KAScheck :149PECTION CHECKLTST
Massachusetts Energy Code
KAScheck Software Version 2 ,0
NORTHERN AVENUE
DATE: 1-2-2000
Bldg.
Dept.
Use
CEILINGS:
1. R-38
Comments/LoCat ion---.-
L 1 2 . R-38
Conrnents/Location_.
L 1 3 . R-38
Comments/Location
WALLS, :
1. Wood Frame, 16" 0 ,C. , R-11
Comments/Location
WINDOWS AND GLASS DOORS :
1. U-value: 0 .25
For windows without labeled U-values, describe featureii:
# Panes Frame Type
Thermal Break? Yes I X:)
Comments/Location-
2 . U-value : 0 .30
For windows without labeled U-values, describe features-
# Panes_— Frame Type— Thermal Break? Yes No
Comments/Location _ _
SKYLIGHTS :
1. U-value : 0 .24
For skylights without labeled U--values, describe featt-rei!3 :
# Panes Frame Type— Thermal Break? 'Yes C !',R)
Comments/Location----_-____
DOORS :
1 . U-valve : 0 .16
Comments/Location
2 . Uvalue : 0 .28
Comment s/Location__.________
FLOORS :
1. Over Unconditioned Space, R-19
Comments/
HVAC EQUIPMENT EFFICIENCY:
I. Furnace, 90 .0 AFUE or higher.
Make and Model Number
THERMOSTATS :
Adjustable thermostats required for each HVAC system.
AIR LEAXAGE !
I Joints, penetrations, and all other such openings in the
envelope that are sources of air leakage must he sealed. RuCIC-SSS(i
lights must be type IC rated and installed with no pene"--ratlicr.cs
or installed inside an appropriate air-tight assembly with, a C . 511
FROM : LYNN DECHESSER CPBD PHONE NO. : 1 413 569 0612 Jan. 24 2000 02:21PM P1
rp n _ ..
MAScheck COMPLIANCE REPORT
Massachusetts Energy Code Permit #
MAScheck Software Version 2 .0 FED 2 8 20M
k
Checked by/Date
CITY:
STATE: Massachusetts
HDD: 6614
CONSTRUCTION TYPE: 1 or 2 family, detached
HEATING SYSTEM TYPE: Other (Non-Electric ResistanCe)
DATE: 1-2-2000
DATE OF PLANS; JANUARY 24, 2000
TITLE: NORTHERN AVENUE
PROJECT INFORMATION:
MCCUTCHFON DEVELOPMENT
12 TURKEY HILL ROAD
WESTHAMPTON, MA.
COMPANY INFORMATION:
LYNN F. DECHESSER, RESIDEN'T'IAL DESIGNER
74 CONGAMOND ROAD
SOUTHWICK, MA. 01077
413-,569-0612
NOTES:
OPTIONAL SKYLIGHT AT PORCH IS NOT INCLUDED IN CALCULATIONS
COMPLIANCE: PASSES
Required UA - 335
Your Home - 279
Area or Insul Sheath Glazing/Door
Perimeter R-Value R-Value U-Value UA
CEILINGS 204 38.0 0 .0 6
CEILINGS 518 38 .0 0 .0 16
CEILINGS 532 38 .0 010 16
WALLS: Wood Frame, 16" O.C. 1392 13.0 0 .0 115
GLAZING: Windows or Doors 175 0 .250 44
GLAZING: Windows or Doors 21 0 .300 6
GLAZING: Skylights 32 0 .240 8
DOORS 21 0 . 160 3
DOORS 21 0 . 280 6
FLOORS: Over Unconditioned Space 1236 19 .0 59
HVAC EFFICIENCY: Furnace, 90.0 AFUE
COMPLIANCE STATEMENT; The proposed building design represented in these
documents is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building
has been designed to meet the requirements of the Massachusetts Energy Code.
The heating load for this building., and the cooling load if appropriate
s�v a V1�k�lLaqu. dS-t r4A @" �- - s*MA§und