24D-320 (10) ,03/07/2005 14:31 4135847504 CUNSTRUCT ASSUCIATES HAUL by/b'L ,de Compliance Report-Yale House Renovation-pop 9 of 1 I Table 1017.2-Spaces with One Means of Egress Use Group Maximum Occupant Load Maximum Travel Distance R 10 75' S 30 100' Exception 1:Boiler rooms require two cgress doorways where area exceeds 500 SP and individual thel-fired equipment exceeds 400,000 BTU input capacity. No boiler room exceeds this area,therefore this exception does not apply,and only one doorway is required from each boiler room. 1017.3 Size of doors:32"minimum width,80"minimum height. (Exceptions: Interior egress doors withza dwelling units,29%"width,78"minimum height;no minimum width for storage closets less than 10 SF;no width requirements for doors in R-2 which are not required for means of egress.) 1017.4 Door hardware:Shall comply. 1021.0 Guards: Shall comply 1022.0 Handrails: Shall comply 1023.0 Exit Signs and Lights: Shall comply 1024.0 Means of Egress Lighting: Shall comply 1025.9 Fiore Escapes 1025.1.2 Existing foe escapes: Accepted as component of:means of egress 1025.1.4 Limitations.Shall not constitute more than 50%of required number of exits or exit capacity. Note: 50%of required number of exits accommodated by internal stair, Second fire escape provides a third means of egress over and above required exits. 10253 Construction 10253.2 Opening protectives:Doors and windows along fire escape to be protected with% boor protectives. This would only apply to alterations,and none are being proposed along the north fire escape. Where are alterations along the south fire escape,but this escape provides a third means of egress which is an additional rather than a.required means of egress. Therefore,it need not comply with this requirement. Chapter 12-Xnterfior Environment Room dimonsion,lighting and ventilation requirements shall comply. 1214.0 Sound Transmission Control in Residential Buildings 1214.2 Air-Borne noise: Walls,floorlceilings between units and units 8t common areas: STC 45 for air-bonne noise. 1214.3 Structure-borne sound: Floor-ceiling assemblies 11C 45. Chapter 13-Energy Conservation See Chapter 34, .03/07/2005 14:31 413b841504 UU4Nb 1 NUU 1 A55UU1A l t5 F Atat !71/t�L 01yD _ JdO �,n " Hobie Iselin, General Contractor Construction Supvr. Lic.#039073 ,rr { A r faxt r a n S m to: Tony Patillo tax: 1587-1272 from: Hobie Iselin —36 Service Center, Northampton MA Telephone #413.584-1224 date: FMarrh 7, 2005 Fax: L 13) 584-7504 fe: Code review for Round Hill Rd. pages: 2 Hi Tony, Attached is the page in question from the code report by Mary Kraus for Round Hill Rd. The existing fire escape egress doors are single swing multi-pane french doors, untempered glass, with no built-in weatherstripping in poor condition. I would like to replace these with similar doors in the same jamb in the same opening, but with tempered, insulated glass and full weatherstripping. Mary is of the opinion that the new doors would have to comply with the code requirement of% hour rating. It seems logical to me to change the doors to make them more attractive, safer and more energy efficient, but I won't change them if I will be required to make them solid fire rated doors. Thanks for taking a look at this. Hobie ® KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 73 �� Yale House Renovation 88 Round Hill Road,Northampton,MA Site Report— 1/21/05 Structural and framing: • The new structural elements are installed according to plans and code requirements. This includes LVL beams in attic, and beams and columns in all units. • Rough framing is complete. • Strapping is near completion. Mechanical: • Unit 1: 75%complete. • Unit 2: duct installation complete. • Unit 3: interior installation complete. • Unit 4: interior installation complete. Plumbing: • Rough waste piping is complete. • Supply piping complete in Unit 4. Electrical: • Rough electrical installation has begun in Unit 4. Finish carpentry: • Flooring installation is in progress in Unit 3. Respectfully submitted, / Mary Kraus AIA Principal Architect 110 Pulpit Hill Road,Amherst MA 01002 413.549.5799 Fax: 413.549.7918 www.krausfitch.com 1 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 1/26/05 Addendum to Code Compliance Report — Yale House Renovation 88 Round Hill Road, Northampton, MA. The following requirements shall be added to the Code Compliance Report dated 1/20/05: Fire escapes: ♦ Both existing fire escapes shall be compliant with code requirements for loads. A structural engineer shall be engaged to verify compliance. Fire protective signaling systems: ♦ All fire detection devices in the S-1 storage areas(including both heat detectors and smoke detectors) shall be wired to provide notification in R-2 areas above. ♦ Horn/strobes shall be placed in common areas. 110 Pulpit Hill Road,Amherst MA 01002 413.549.5799 Fax: 413.549.7918 www.krausfitch.com o? � - Sad ® KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design TRANSMITTAL PROJECT#: 04-29 DATE: 2/18/05 TO: Anthony Patillo, Building Commissioner RE: Yale House, 88 Round Hill Road Building Inspections 2112 Main Street Northampton, MA 01060 ENCLOSED: NO: DATE: DESCRIPTION: 1 1/26/05 Addendum to Code Compliance Report REMARKS: I spoke with Hobie Iselin of Construct Associates on 1/25/05 to inform him of the issues, reflected in the attached Addendum,that you had brought to my attention. He understood all the issues and was prepared to address them as required. TRANSMITTED BY: Mary Kraus COPIES: Hobie Iselin, Construct Associates 110 Pulpit Hill Road,Amherst MA 01002 413.549.5799 Fax: 413.549.7918 www.krausfitch.com