36-363 (2)
Air Leakage Property Organization HERS 123 Emerson Way Power House Energy Consulting Confirmed Northampton, MA 01062 413-835-5162 3/14/14 Matt Turcotte Rating No:HERS-119 Weather:Northampton, MA Rater ID:1497133 HERS-119 123 Emerson Way Builder registered.blg Rosemund LLC Whole House Infiltration Blower Door Test Heating Cooling Natural ACH 0.08 0.06 ACH 50 Pascals 1.09 1.09 CFM 25 Pascals 328 328 CFM 50 Pascals 514 514 Eff. Leakage Area (sq.in) 28.2 28.2 Specific Leakage Area 0.00005 0.00005 ELA/100 sf shell (sq.in) 0.43 0.43 Duct Leakage Leakage to Outside Units ductless ashy CFM @ 25 Pascals 0 CFM25 / CFMfan 0.0000 CFM25 / CFA 0.0000 CFM per Std 152 N/A CFM per Std 152 / CFA N/A CFM @ 50 Pascals 0 Eff. Leakage Area (sq.in) 0.00 Thermal Efficiency N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage 0.0000 Ventilation Mechanical Exhaust Only Sensible Recovery Eff. (%) 0.0 Total Recovery Eff. (%) 0.0 Rate (cfm) 66 Hours/Day 24.0 Fan Watts 6.8 Cooling Ventilation Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, a minimum of 66 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 131 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required REM/Rate- Residential Energy Analysis and Rating Software v14.4.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation, Boulder, Colorado. Home Energy Rating Certificate 123 Emerson Way Northampton,MA 01062 Ei� Estimated Annual Energy Cost Use MMBtu Cost Percent 5 Stars Plus Heating 45.6 $660 30% Confirmed HERS Index•41 Cooling 2.7 $136 6% Hot Water 13.0 $183 8% Lights/Appliances 26.7 $1251 56% General Information Photovoltaics -0.0 $-0 -0% Conditioned Area 3565 sq.ft. House Type Single-family detached Service Charges $0 0% Conditioned Volume 28382 cubic ft. Foundation Conditioned basement Bedrooms 3 Mechanical Systems Features Cooling: Air-source heat pump,Electric,19.0 SEER. Integrated Htg/DHW: Natural gas,Htg eff 0.95 CAafue.DHW eff 0.95 CAef. Duct Leakage to Outside 0.00 CFM25. Ventilation System Exhaust Only:66 cfm,6.8 watts. Programmable Thermostat Heat=Yes;Cool=No Building Shell Features Ceiling Flat R-44.5 Slab R-0.0 Edge,R-0.0 Under Sealed Attic NA Exposed Floor R-51.6 Vaulted Ceiling R-25.4 Window Type U-Value:0.280,SHGC:0.250 TITLE Above Grade Walls R-19.3 Infiltration Rate Htg:514 Clg:514 CFM50 Company Foundation Watts R-18.0 Method Blower door test Address City,State,Zip Lights and Appliance Features Phone# Percent Interior Lighting 96.40 Range/Oven Fuel Natural gas Fax# Percent Garage Lighting 100.00 Clothes Dryer Fuel Electric Refrigerator(kWh/yr) 582.00 Clothes Dryer EF 3.10 Dishwasher Energy Factor 0.79 Ceiling Fan(cfm/Watt) 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate-Residential Energy Analysis and Rating Software 04.4.1 This information does not constitute any warranty of energy cost or savings. ®1985-2014 Architectural Energy Corporation,Boulder,Colorado. �o z o � Z 00 3 CD N A .� O a-+ ti Z CA N 1^ O /^�1 00 •v (� O W Q$ C) u w a) � v Q Q t� 14� 3 ' V t ¢ v oo t O O �y�` V zzt Via CU F4 • •N z CA , N i C� '� r-I r a � O o W C vi y iii �° ° c Q � A �s - 2 V � U ~ V .G C) 4 U o O o u 0 C) o V v U p t1c '" ba W tz m ;J Z Pa Cn P� 123 EMERSON WAY BP-2014-0068 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 36-363 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Single Family House BUILDING PERMIT Permit# BP-2014-0068 Project# JS-2014-000149 Est. Cost: $320000.00 Fee: $1338.60 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: GREGORY QUILL 105857 Lot Size(sq. ft.): 9670.32 Owner: MYRON TOM&JESSICA NICOLL Zoning: Applicant: GREGORY QUILL AT: 123 EMERSON WAY Applicant Address: Phone: Insurance: 23 E HADLEY RD (413) 695-4195 WC HADLEYMA01035 ISSUED ON.•81512013 0:00:00 TO PERFORM THE FOLLOWING WORK.-CONSTRUCT 2 STORY SFH W/ATT GARAGE/PORCH/DECK POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: ;? y j S� Rough: _ _ House# Foundation: Driveway Final: Final: �&7 ;] �1 Final: � Rough Frame: Gas: </ � Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: v i7 Smoke: - �i��� �TiTHIS PERMIT MAY BE REVO D B THE CITY OF NORTHAMPTON UPON VIION F ANY OF ITS RULES AND GU [l- /� Certificate of Occu anc Si nature: Q' 'lam !F YLo"L FeeType: Date Paid: Amount: Building 8/5/2013 0:00:00 $1338.60 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner