31B-296 (6) a
n fAi,n C►Q � �7`lf
/
Project Jab:
Pro Summary
J Summary Date: Feb 14,2014
- - wrightsoft° Entire House BY:
Project Inf• •
For:
3 TYLER COURT, NORTHAMPTON, MA
Notes:
Weather: Springfield Westover AFB, MA, US
Winter Design Conditions Summer Design Conditions
Outside db 0 OF Outside db 87 OF
Inside db 70 OF Inside db 75 OF
Design TD 70 OF Design TD 12 OF
Daily range M
Relative humidity 50 %
Moisture difference 24 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 28867 Btuh Structure 20791 Btuh
Ducts 2887 Btuh Ducts 2079 Btuh
Central vent(0 cfm) 0 Btuh -Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 31754 Btuh Use manufacturer's data n
Rate/swing multiplier 0.92
Infiltration Equipment sensible load 21041 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2555 Btuh
Ducts 0 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft2) 856 856 Equipment latent load 2555 Btuh
Volume(ft') 8732 8732
Air changes/hour 1.20 0.50 Equipment total load 23595 Btuh
Equiv. AVF (cfm) 175 73 Req. total capacity at 0.70 SHR 2.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80 AFUE Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 OF Total cooling 0 Btuh
Actual air flow 1223 cfm Actual air flow 1223 cfm
Air flow factor 0.039 cfm/Btuh Air flow factor 0.053 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.90
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
2014-Feb-14 15:53:2
t wrilghtsOft` Right-Suite®Universal 2013 13.0.09 RSU07086 Page
...n\My Documents\3 TYLER COURT,NORTHAMPTON,MA.rup Calc=MJ7 Front Door faces: N
Load Short Form Job:
Date: Feb 14,2014
. . wrightsaft, Entire House By:
Project • •
For:
3 TYLER COURT, NORTHAMPTON, MA
Design Information
Htg Clg Infiltration
Outside db (°F) 0 87 Method Simplified
Inside db (°F) 70 75 Construction quality Average
Design TD(°F) 70 12 Fireplaces 0
Daily range - M
Inside humidity (%) 50 50
Moisture difference (gr/Ib) 50 24
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80 AFUE Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 OF Total cooling 0 Btuh
Actual air flow 1223 cfm Actual air flow 1223 cfm
Air flow factor 0.039 cfm/Stuh Air flow factor 0.053 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.90
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
READING ROOM 168 18415 12087 709 646
COMMONROOM 132 2634 1988 101 106
COMMONS BATH 72 1371 1008 53 54
BEDROOM 203/CL. 247 4764 3587 183 192
BEDROOM 204/CL. 238 4571 4200 176 225
Entire House d 856 31754 22870 1223 1223
Other equip loads 0 0
Equip. @ 0.92 RSM 21041
Latent cooling 2555
TOTALS 856 31754 23595 1223 1223
Calculations approved by ACCA to meet all requirements of Manual J 7th Ed.
u� 2014-Feb-14 15.50:01
!�w-� + ^"g'�ft' Right-Suket UnWarsal201313.0.0903 7, Page 1
-fJG. k..AWy OocumentsQ TYLER COURTNORThfAMPTON,MA.rup Calc='MJ7 Front Door faces: N
INSURANCE COVERAGE:
I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 Ye&fZ No❑
If you have checked Yes,indicate the type of coverage by checking the appropriate box below:
A liability insurance policy ❑ Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee claps not hay p the insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application waimm this requirement.
Check One Only
Owner ❑ Agent ❑
Signature of Owner or Owner's Agent
By checking this box13,1 hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation:YES NO
Prngrpec InenpPtlAne
Date comme tc
Final Inepee inn
Date
(nmmPntc
Type of License:
By -Master
Title ❑Master-Restricted
City/Town ❑Journeyperson ' Signature of Licensee
Permit# ❑Journeyperson-Restricted 2 License Number: 7 �j (-
y
Fee$
Check at macc_n�nvhipl
Inspector Signature of Permit Approval
Commonwealth of Massachusetts
Of Northam
.� City O ton p
MAR — 4 'u i.r� 'i
Sheet Metal Permit Permit
ec'
Estimated7o$ ' Permit Fee: $
Plans Submitted: YES NO Plans Reviewed: YES NO
Business License# Applicant License# 3 7 a�
Business Information: Property Owner/Job Location Information:
Name: L' od ykxk-S ��vM bltis fl4ame: C rx- le
Street: !� C9 (c 5e `�1( �f 1✓t�' Street: 3 ! y 1-e f C T
City/Town: go v rkc;o gbT City/Town: IVo t'TkaM /J 10 h
Telephone: (A 1 —rj a j-d-Z 7's- Telephone:
Photo I.D. required/Copy of Photo I.D. attached: YES NO
Staff Initial
J-1 /M- nrestricted license
J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less
Residential: 1-2 family eL Multi-family Condo/Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other
Square Footage: under 10,000 sq. ft. _,/ over 10,000 sq. ft. Number of Stories:
Sheet metal work to be completed: New Work: r)J Renovation:
HVAC t./,- Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
A , (- 1 �15 oh!,�,
Ott, a i O g l'q )k 'J-hd
�4 41, 4 le 1,1 co �_.cfi I-(oho-ce A- VIC
Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000
Minimum fees for jobs without Building Permit$50.00 Residential,$100.00 Commercial
File#SM-2014-0047
APPLICANT/CONTACT PERSON WALUNAS PLUMBING&HEATING INC
ADDRESS/PHONE 218C COLLEGE HIGWAY (413)529-2675
—51+600
PROPERTY LOCATION 3 TYLER CT
MAP 3 1 B PARCEL 296 001 ZONE URC000)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out
Fee Paid
Typeof Construction: ADD AIR CONDITIONING&AIR HANDLER FOR ADDITION
New Construction
Non Structural interior renovations
Addition to Existing
Accesso Structure
Building Plans Included:
Owner/Statement or License 3724 M
3 sets of Plans/Plot Plan
THE FOLL ING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFO TION PRESENTED:
pproved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER: §
Intermediate Project : Site Plan AND/OR Special Permit with Site Plan
Major Project: Site Plan AND/OR Special Permit with Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
om Elm Street Commission Permit DPW Storm Water Management
Date
4ature Oingfficial
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of
Planning&Development for more information.
3 TYLER CT SM-2014-0047
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS#: 6129
Map: 131B "
Bock: 296 SHEETMETAL PERMIT
- . ,
Lot: 001 .
Permit: (SHEETMETAL
Category: jSHEETMETAL
Permit# SM-2o 14-0047 _. PERMISSION IS HEREB Y GRANTED TO:
_-
Project# 2-2014-000833
Contractor: License: Expires:
S .
E t Cost: $6,200.00
Fee Charged: WALUNAS PLUMBING&HEATINSheetmetal-3724 M 12/28/2015
- - ---
,Balance Due:l$.00 Owner: CHRISLER JENNIFER&CHERYL JACQUES
#of Fixtures:11 Applicant: WALUNAS PLUMBING&HEATING INC
DigSafe# AT. 3 TYLER CT
I
Use Group I
�ConstClass
ISSUED ON. 04-Mar-2014 AMENDED ON: EXPIRES ON.
TO PERFORM THE FOLL O WING WORK.
ADD AIR CONDITIONING&AIR HANDLER FOR ADDITION
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2014-003995 04-Mar-14 5942 $25.00