Loading...
Smith Access PlansCONFERENCE ROOM 105 SEMINAR ROOM 104 CORRIDOR 100 C2 100 ST2 100 T2 RAMP PORCH 100 P2 OFFICE 107 OFFICE 101 SECRETARY 106 PHILOSOPHY STUDY 102 FOYER 100 F CORRIDOR 100 C1 FRONT PORCH 100 P1 00 ST1 HALL 100 C3 COPY 103 100 L 100 J1 100T1 SEE APPLICATION FOR HANDRAIL VARIANCE EXISTING OFFICE DOORS ON FIRST FLOOR ARE SUFFICIENT WIDTH WITH ADEQUATE CLEARANCES. SEE APPLICATION FOR SOME THRESHOLD HEIGHTS. EXISTING ACCESSIBLE UNISEX TOILET ROOM EXISTING ACCESSIBLE STAIR NEW PROPOSED LIFT EXISTING RAMP FIRST FLOOR PLAN Scale: 1/8" = 1'-0"1 DE W E Y H A L L SM I T H C O L L E G E NO R T H A M P T O N , M A K R A U S - F I T C H AR C H I T E C T S , I N C . HO M E C O M M U N I T Y P L A N E T 11 0 P u l p i t H i l l R o a d Am h e r s t , M a 0 1 0 0 2 4 1 3 - 5 4 9 - 5 7 9 9 Fa x : 4 1 3 - 5 4 9 - 7 9 1 8 ww w . k r a u s f i t c h . c o m A-1.1 FIRST FLOOR PLAN OFFICE 214 OFFICE 213 OFFICE 212 OFFICE 211OFFICE 210 OFFICE 209 OFFICE 215 OFFICE 202 OFFICE 201 OFFICE 206 OFFICE 204 OFFICE 203 203A 200 ST2 200 C3 200 C2 200 C1 (O P E N T O B E L O W ) 200 ST1 OFFICE 207 200 ST2 200 ST3 200 J NEW OFFICE 205 NEW MTG. RM./FLEX SPACE 208 NEW LOUNGE 200 L UNISEX HP TOILET 200 T1 UNISEX HP TOILET 2OOT2 SEE APPLICATION FOR VARIANCE TO EXISTING DOORS (WIDTHS & CLEARANCES) AT BACK WING OF SECOND FLOOR NEW ACCESSIBLE TOILETS NEW LIFT AND LOUNGE SEE APPLICATION FOR VARIANCE TO EXISTING DOORS (WIDTHS & CLEARANCES) AT BACK WING OF SECOND FLOOR SEE APPLICATION FOR CLOSET ACCESS VARIANCES DOORS IN FRONT WING OFFICES ARE OF SUFFICIENT WIDTH. SEE APPLICATION FOR CLEARANCE REQUIREMENTS NEW ACCESSIBLE TOILETS NEW ACCESSIBLE "FLEX SPACE" AS COMPLIANCE ALTERNATIVE SECOND FLOOR PLAN Scale: 1/8" = 1'-0"1 DE W E Y H A L L SM I T H C O L L E G E NO R T H A M P T O N , M A K R A U S - F I T C H AR C H I T E C T S , I N C . HO M E C O M M U N I T Y P L A N E T 11 0 P u l p i t H i l l R o a d Am h e r s t , M a 0 1 0 0 2 4 1 3 - 5 4 9 - 5 7 9 9 Fa x : 4 1 3 - 5 4 9 - 7 9 1 8 ww w . k r a u s f i t c h . c o m A-1.2 SECOND FLOOR PLAN 300 ST3 300-C OFFICE 306 OFFICE 305 OFFICE 304 OFFICE 303 OFFICE 302 OFFICE 301 30 0 T 30 0 S T 2 ATTIC 300A SEE APPLICATION FOR THIRD FLOOR TOILET ROOM VARIANCE SEE APPLICATION FOR THIRD FLOOR OFFICE ACCESS VARIANCE ROOF OF LIFT IS BELOW THE LOW EAVE LINE OF THIS FLOOR THIRD FLOOR PLAN Scale: 1/8" = 1'-0"1 DE W E Y H A L L SM I T H C O L L E G E NO R T H A M P T O N , M A K R A U S - F I T C H AR C H I T E C T S , I N C . HO M E C O M M U N I T Y P L A N E T 11 0 P u l p i t H i l l R o a d Am h e r s t , M a 0 1 0 0 2 4 1 3 - 5 4 9 - 5 7 9 9 Fa x : 4 1 3 - 5 4 9 - 7 9 1 8 ww w . k r a u s f i t c h . c o m A-1.3 THIRD FLOOR PLAN