ADDENDUM 1 SKECTHES-ARCHITECTURAL KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-1
April 23, 2012
00-ST1
R
01-A
APPROXIMATE LOCATION OF PIER
UNDER HUMP IN FLOOR ABOVE.
OPEN UP FRAMING ABOVE TO
INVESTIGATE AND REPAIR
APPROXIMATE LOCATION OF
CHILLED WATER MAINS
TYPICAL NEW POST AND FOOTING,
SEE STRUCTURAL DRAWINGS
NEW POST AND
FOOTING, SEE
STRUCTURAL
EXISTING (UNUSED)?
PANELS
NEW STEEL POST IN PLACE OF
CONFLICTING PEIR, IF REQUIRED BY
PLACEMENT OF NEW FOOTING
6"
6'
-
0
"
CL
E
A
R
6"
TB
D
TO
A
V
O
I
D
S
P
R
I
N
K
L
E
R
CO
N
F
L
I
C
T
CRAWL SPACE
C
D
C'
4 5
BASEMENT FLOOR PLAN
Scale: 1/4" = 1'-0"
1
A-1.0
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-2
PHILOSOPHY STUDY
100 ST1
FOYER
00 ST1
SECRETARY
OFFICE
107
MAIL
100 J1
F.C.
C
D
C'
4 5
FIRST FLOOR STRUCTURAL PLA N
Scale: 1/4" = 1'-0"
1
A-1.1
April 23, 2012
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-3
OFFICE
201
UP
200 ST1
200 ST2
CORRIDOR
200 C1
OFFICE
215
CUT SHELVING AS
NEEDED AND
RELOCATE STANDARDS.
EXISTING
BULLETIN
BOARDS TO
REAMIN
PROBABLE
LOCATION OF
EXISTING HEARTH
RESET TILE AS
NEEDED.
NEW T.S.
NEW T.S.
EXISTING WOOD
THRESHLD
EXISTING WOOD
THRESHLD
SHORTEN BOOK
SHELVES AND
MOVE
STANDARD
APPROX 12",
FIRMLY SECURE
STANDARD TO
FRAMING
F.
C
.
NEW ERV CHASE + PIPE
NEW T.S.
CU ST
200J-2
NEW CUSTODIAL CLOSET
W/NEW FLOOR SINK AND
VINYL FLOORING.
NEW POST, EXPOSE TO
CORRIDOR SIDE IF NEEDED.
PATCH FINISHES
NEW ERV AND PIPE CHASE IN CLOSET
NEW REC'D
ELEC PANEL
RETAIN AND REUSE
ROSETTES AND TRIM AS
POSSIBLE. MATCH NEW.
RETAIN SUFFICIENT
CHASE AREA TO
ENCLOSE EXISTING
PLUMBING RISER
NEW POST, BURY
INTO NEW WALLS.
NEW ERV DUCTS IN
PROBABLE EXISTING
CHASE LOCATION
C
D
C'
4 5
SECOND FLOOR STRUCTURAL PLA N
Scale: 1/4" = 1'-0"
1
A-1.2
April 23, 2012
10
'
-
1
0
"
+
/
-
2'-
9
"
+
/
-
11
'
-
8
"
+
/
-
8'-
8
"
+
/
-
PHILOSOPHY LOUNGE STAIR
OFFICE
204 HALL
200 C1
9'-
1
0
1
/
2
"
+
/
-
A-3.0
2
6
A-4.0
3
A-4.0
1
A-4.0
2
A-4.0
FOYER
17'-9" +/-8'-0" +/-15'-11" +/-
6'-2" +/-
3'-7" +/-
12'-1" +/-14'-11" +/-
15'-2" +/-3'
-
6
"
2'-
8
"
8'-4 3/16" +/-6'-6 5/8" +/-
CD C'
CROSS-SECTION @ OLDER WING
Scale: 1/8" = 1'-0"
1
A-3.0
K
R
A
U
S
-
F
I
T
C
H
AR
C
H
I
T
E
C
T
S
,
I
N
C
.
En
v
i
r
o
n
m
e
n
t
a
l
l
y
i
n
s
p
i
r
e
d
d
e
s
i
g
n
11
0
P
u
l
p
i
t
H
i
l
l
R
o
a
d
Am
h
e
r
s
t
,
M
a
0
1
0
0
2
4
1
3
-
5
4
9
-
5
7
9
9
Fa
x
:
4
1
3
-
5
4
9
-
7
9
1
8
ww
w
.
k
r
a
u
s
f
i
t
c
h
.
c
o
m
DE
W
E
Y
H
O
U
S
E
SM
I
T
H
C
O
L
L
E
G
E
NO
R
T
H
A
M
P
T
O
N
,
M
A
SK
-
4
Ap
r
i
l
2
3
,
2
0
1
2
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-5
April 23, 2012
EXISTING DEEP WINDOW
SILL EXTENDS 4.5"
BEYOND EXISTING
SHEATHING
SCRAPE AND PAINT
WOOD COINING @
CORNERS OF FRONT
WING
EXISTING STUDS @
APPROX. 20" OC
EXISTING WINDOW
TRIM TO REMAIN
EXISTING BLOCKING
(ASSUMED)
FIELD INVESTIGATE JAMB
CONDITIONS, INSULATE
CAVITY FROM EXTERIOR
BY REMOVING BRICKS AS
NEEDED (GOAL IS TO
REDUCE AIR LEAKAGE)
LINE OF EXISTING FLAT
SIDING @ FRONT PORCH
INSULATE WEIGHT POCKETS, SEE NOTE
3/A-5.0 FRAME EXPANDER
MAKES RETURN FROM
INSERT TO TRIM
NEW INSERT
WINDOW @ FIRST
FLOOR SPLAYED
WINDOW
TURN HOUSE WRAP MIN
3/8", SEAL TO TRIM. SEE
NEW DETAIL SK-10 FOR
EXTENSION OF WINDOW
CAP FLASHING TO
COVER JOINT.
-NEW SIDING
-ON RAIN SCREEN MAT
-ON BUILDING PAPER
-ON EXISTING SHEATHING
TYPICAL SIDING CONSTRUCTION:
PAINT CUT ENDS OF
CLAPBOARDS
PLAN DETAIL@ COINED CORNERS
Scale: 1 1/2" = 1'-0"
1
A-5.0
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-6
April 23, 2012
EXISTING BATT INSULATION TO BE
REMOVED WHERE READILY
ACHIEVABLE
FLASH WITH 2" CLOSED
CELL, FINISH WITH 6" OPEN
CELL FOAM INSULATION
(TOTAL ASSEMBLY = R-40)
NEW ACCESS HOLES FOR
INSULATION, SEE 2A-4.0
TUCK HOUSE WRAP
UNDER FRIEZE BOARD 2"
+/-.
EAVE SECTION WITHOUT WINDOW
Scale: 1 1/2" = 1'-0"
2
A-5.0
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-7
April 23, 2012
EXISTING DEEP WINDOW
SILL
EXISTING DEEP
SILL
EXISTING
ORNATE APRON
EXISTING WALL SYSTEM:
-PLASTER
-ON LATHE
-CAVITY WITH WALL STUDS
-BRICK NOGGING BETWEEN POSTS
-SHEATHING
HOUSE WRAP. TO
LAP NEW FLASHING
CUT DRIPEDGE ON UNDERSIDE
OF ALL WINDOW SILLS
TURN HOUSE WRAP
BACK AND UNDER SILL
FRAME EXPANDER
MAKES RETURN FROM
INSERT TO EXISTING SILL
NEW SIDING
SECOND FLOOR WINDOW SILL
Scale: 1 1/2" = 1'-0"
3
A-5.0
REMOVE EXISTING WEIGHTS IN
WEIGHT POCKETS, DRILL 2"
HOLES THROUGH EXISTING
WINDOW JAMB(TOP AND
MIDDLE), BLOW CELLULOSE
INSULATION IN AND PLUG
BEFORE NEW WINDOW
INSTALLATION, OR DETERMINE
OTHER METHOD IN FIELD.
INSULATION OF JAMB POCKETS
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-8
April 23, 2012
REPLACE WITH NEW WATER
TABLE, BLOCK OUT WITH P.T.
SHEATHING, UNDERCUT FOR
DRIP
BUGSCREEN AT BASE OF
RAIN SCREEN
NEW SIDING ON RAIN SCREEN
MATT. ON EXISTING SHEATHING
BOARDS
LINE OF WALL BEYOND
ADD NEW FIXED WINDOW
INSERT, INSTALL 2" BACK
FROM EXISTING FRAME
REPLACE ROTTEN SECTIONS OF WINDOW FRAMESREMOVE EXISTING
WINDOW, FOAM
INSULATION TO EXISTING
FRAME
NEW BREAK METAL FLASHING @ SILL, JAMB, AND HEAD TO
COVER EXISTING WINDOW FRAME. MATCH WINDOW COLOR
SEAL WINDOW TO FRAME
HOUSEWRAP TO LAP
NEW FLASHING
EXISTING SHEATHING
REPLACE AS NEEDED
NEW FLASHING UNDER
NEW SIDING
FRONT WING FIRST FLOOR AND FOUNDATION DETAIL
Scale: 1 1/2" = 1'-0"
5
A-5.0
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-9
April 23, 2012
EXISTING 6 1/2"x 1
1/4" ORNATE
WINDOW CASING
AND MEDALLIONS
EXISTING DEEP
WINDOW HEAD
WITH PANEL
EXISTING
EXTERIOR
WINDOW
CASING
NEW SIDING
APPROX. CAVITY
DEPTH (FIRST FLOOR
FRONT WING ONLY)
HOUSE WRAP. TO
LAP NEW FLASHING
EXTEND CAP FLASHING
BEYOND OUTSIDE FACE
OF VERTICAL TIM MIN.
OF 1/2"
TURN HOUSE WRAP
BACK AND UNDER SILL
SPLAYED WINDOW HEAD (DEEP)
Scale: 1 1/2" = 1'-0"
7
A-5.0
1
A-5.0
CAP FLASHING EXTENDS
MIN 1/2" BEYOND
OUTSIDE EDGE OF TRIM.
LAP HOUSEWRAP OVER
HOUSE WRAP PUSHED UP
UNDER EXISTING
CORNICE MIN OF 2".
HOUSE WRAP TURNS
AGAINST EXISTING TRIM
AT WINDOWS, COINING
AND OTHER VERTICAL
TRIM, MIN 3/8" AND
SEALED AGAINST TRIM.
HOUSE WRAP TURNS
BACK AND UNDER SILL
CAP FLASH AS POSSIBLE
AT CORNICE.
WINDOW ELEVATION DETAIL
Scale: 1/2" = 1'-0"
9
A-5.1
KRAUS-FITCH
ARCHITECTS, INC.
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MAHOME COMMUNITY PLANET APR. 23, 2012
SK-10
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-11
April 24, 2012
CONFERENCE ROOM
CORRIDOR
100 C2
100 ST2
FIRE STAIR
RAMP PORCH
HALL
100 C3
SEMINAR ROOM
104
COPY
103
100 L
LIFT LOBBY
ACC. TOILET
100 T2
10
0
J
2
4' SCREEN
PROJ.
PROJ.
EXISTING SOFFIT @ BREAK
IN CEILING HEIGHT
9'-1"
9'-1"
9'-8"
COORDINATE WITH OWNER FOR REMOVAL AND
REINSTALLATION PROJECTOR, SCREEN AND
SPEAKERS IN CONFRENCE AND SEMINAR ROOM
9'-1"
8' SCREENSP.SP.
EXISTING FIXTURES TO REMAIN AT TOILET ROOM
SO
SO 9'-9' 1/2"
9'-9' 1/2"
SO
NEW REC'D CANS SEE SKE-1
1 2
FIRST FLOOR REFLECTED CEILING PLAN
Scale: 3/16" = 1'-0"
1
A-1.6
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-12
April 24, 2012
B03
B04
B05
CUT PLASTER @ FULL PERIMETER OF BASEMENT FOR INSULATION AT SILLDEMO BATHROOM WALLS, ETC.
EXISTING PIERS TO REMAIN. LOCATE
DEMOLITION FOR NEW FOOTING TO AVOID
UNDERMINING.
DEMO WHOLE WALL IF POSIBLE. EXPLORE
FLOOR STRUCTURE TO DETERMINE EXTENT
FEASIBLE.
DEMO 30" WIDE PORTION OF WALL AS
NEEDED FOR MECHANICAL. CUT TO CEILING
HEIGHT AND INSTALL NEW STEEL HEADER
TO CARRY MID SPAN OF JOISTS.
CUT SECTIONS OF SLAB AND CEILING
FOR NEW FOOTINGS AND POST, SEE
STRUCTURAL AND ARCHITECTURL
DRAWINGS..
CUT WALL ABOVE DOOR FOR DUCT
PENETRATIONS
CUT SLAB FOR PLUMBING
PER P2.0
CUT PIT FOR EJECTOR PER DETAIL ON P3.0
DEMO PERIMETER OF
CRAWL SPACE CEILING
FOR INSULATING SILL.
BASEMENT DEMO PLAN
Scale: 1/4" = 1'-0"
1
D-1
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-13
April 24, 2012
CONFERENCE ROOM
105
CORRIDOR
100 C2
RAMP PORCH
100 P2
HALL
100 C3
100T1
OPEN UP CHASE WALL AS
NEEDED ON CORRIDOR SIDE FOR
NEW MEP INSTALLATIONS.
DEMO PLUMBING
FIXTURES
REMOVE AND RELOCATE
EXISTING DOOR FRAME AND
HARDWARE. DEMO WALL FOR
RELOCATION OF DOOR AND
NEW POST.
DEMO WALL
FOR NEW
POSTS
REMOVE DOOR, AND TRIM
RETAINING CURRENT RO.
DEMO
CABINETRY
(4) EXTERIOR WALL
PENETRATIONS FOR NEW
SPRINKLER HEADS
DEMO EDGE OF CEILING TO WALL
ACCESS/CEILING INTERSECTION FOR
INSULATION.
2
A-3.0
3
A-1.3
3
A-1.3
1
A-3.1
1 2
FIRST FLOOR DEMO PLAN
Scale: 3/16" = 1'-0"
2
D-1
KRAUS-FITCH
ARCHITECTS, INC.
Environmentally
inspired design
110 Pulpit Hill Road
Amherst, Ma 01002
413-549-5799
Fax: 413-549-7918
www.krausfitch.com
DEWEY HOUSE
SMITH COLLEGE
NORTHAMPTON, MA
SK-14
April 24, 2012
200 ST2
200 ST1
200 ST2
20
0
J
HALL
200 C2
OFFICE
215
NEW OFFICE
205
CU ST
200J-2
ALL PLASTER CEILINGS IN SECOND FLOOR TO REMAIN (EXCEPT AS NOTED OR DAMAGED). REPAIR ALL WATER DAMAGED AREAS AND SEAMS. PAINT ALL SURFACES
9'-10"
8'-0"
LINE OF BREAK IN
CEILING
REPAIR CEILINGS IN
AREA OF WALL
REMOVAL AND NEW
WALL
CONSTRUCTIONREPAIR EXISTING PLASTER
CEILING AFTER WALL
DEMOS + SUSPENDED
CEILING REMOVAL
SO
LMPP
SO
PP
SO
SO
SO
LOCATE NEW
SUSPENDED FIXTURES
TO ONE SIDE OF EXTG
SPRINKLER HEADS.
MODIFY/ADD FIXTURES PER
SKE-2
SECOND FLOOR REFLECTED CEILING PLAN
Scale: 1/4" = 1'-0"
1
A-1.7