Loading...
ADDENDUM 1 SKECTHES-ARCHITECTURAL KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-1 April 23, 2012 00-ST1 R 01-A APPROXIMATE LOCATION OF PIER UNDER HUMP IN FLOOR ABOVE. OPEN UP FRAMING ABOVE TO INVESTIGATE AND REPAIR APPROXIMATE LOCATION OF CHILLED WATER MAINS TYPICAL NEW POST AND FOOTING, SEE STRUCTURAL DRAWINGS NEW POST AND FOOTING, SEE STRUCTURAL EXISTING (UNUSED)? PANELS NEW STEEL POST IN PLACE OF CONFLICTING PEIR, IF REQUIRED BY PLACEMENT OF NEW FOOTING 6" 6' - 0 " CL E A R 6" TB D TO A V O I D S P R I N K L E R CO N F L I C T CRAWL SPACE C D C' 4 5 BASEMENT FLOOR PLAN Scale: 1/4" = 1'-0" 1 A-1.0 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-2 PHILOSOPHY STUDY 100 ST1 FOYER 00 ST1 SECRETARY OFFICE 107 MAIL 100 J1 F.C. C D C' 4 5 FIRST FLOOR STRUCTURAL PLA N Scale: 1/4" = 1'-0" 1 A-1.1 April 23, 2012 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-3 OFFICE 201 UP 200 ST1 200 ST2 CORRIDOR 200 C1 OFFICE 215 CUT SHELVING AS NEEDED AND RELOCATE STANDARDS. EXISTING BULLETIN BOARDS TO REAMIN PROBABLE LOCATION OF EXISTING HEARTH RESET TILE AS NEEDED. NEW T.S. NEW T.S. EXISTING WOOD THRESHLD EXISTING WOOD THRESHLD SHORTEN BOOK SHELVES AND MOVE STANDARD APPROX 12", FIRMLY SECURE STANDARD TO FRAMING F. C . NEW ERV CHASE + PIPE NEW T.S. CU ST 200J-2 NEW CUSTODIAL CLOSET W/NEW FLOOR SINK AND VINYL FLOORING. NEW POST, EXPOSE TO CORRIDOR SIDE IF NEEDED. PATCH FINISHES NEW ERV AND PIPE CHASE IN CLOSET NEW REC'D ELEC PANEL RETAIN AND REUSE ROSETTES AND TRIM AS POSSIBLE. MATCH NEW. RETAIN SUFFICIENT CHASE AREA TO ENCLOSE EXISTING PLUMBING RISER NEW POST, BURY INTO NEW WALLS. NEW ERV DUCTS IN PROBABLE EXISTING CHASE LOCATION C D C' 4 5 SECOND FLOOR STRUCTURAL PLA N Scale: 1/4" = 1'-0" 1 A-1.2 April 23, 2012 10 ' - 1 0 " + / - 2'- 9 " + / - 11 ' - 8 " + / - 8'- 8 " + / - PHILOSOPHY LOUNGE STAIR OFFICE 204 HALL 200 C1 9'- 1 0 1 / 2 " + / - A-3.0 2 6 A-4.0 3 A-4.0 1 A-4.0 2 A-4.0 FOYER 17'-9" +/-8'-0" +/-15'-11" +/- 6'-2" +/- 3'-7" +/- 12'-1" +/-14'-11" +/- 15'-2" +/-3' - 6 " 2'- 8 " 8'-4 3/16" +/-6'-6 5/8" +/- CD C' CROSS-SECTION @ OLDER WING Scale: 1/8" = 1'-0" 1 A-3.0 K R A U S - F I T C H AR C H I T E C T S , I N C . En v i r o n m e n t a l l y i n s p i r e d d e s i g n 11 0 P u l p i t H i l l R o a d Am h e r s t , M a 0 1 0 0 2 4 1 3 - 5 4 9 - 5 7 9 9 Fa x : 4 1 3 - 5 4 9 - 7 9 1 8 ww w . k r a u s f i t c h . c o m DE W E Y H O U S E SM I T H C O L L E G E NO R T H A M P T O N , M A SK - 4 Ap r i l 2 3 , 2 0 1 2 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-5 April 23, 2012 EXISTING DEEP WINDOW SILL EXTENDS 4.5" BEYOND EXISTING SHEATHING SCRAPE AND PAINT WOOD COINING @ CORNERS OF FRONT WING EXISTING STUDS @ APPROX. 20" OC EXISTING WINDOW TRIM TO REMAIN EXISTING BLOCKING (ASSUMED) FIELD INVESTIGATE JAMB CONDITIONS, INSULATE CAVITY FROM EXTERIOR BY REMOVING BRICKS AS NEEDED (GOAL IS TO REDUCE AIR LEAKAGE) LINE OF EXISTING FLAT SIDING @ FRONT PORCH INSULATE WEIGHT POCKETS, SEE NOTE 3/A-5.0 FRAME EXPANDER MAKES RETURN FROM INSERT TO TRIM NEW INSERT WINDOW @ FIRST FLOOR SPLAYED WINDOW TURN HOUSE WRAP MIN 3/8", SEAL TO TRIM. SEE NEW DETAIL SK-10 FOR EXTENSION OF WINDOW CAP FLASHING TO COVER JOINT. -NEW SIDING -ON RAIN SCREEN MAT -ON BUILDING PAPER -ON EXISTING SHEATHING TYPICAL SIDING CONSTRUCTION: PAINT CUT ENDS OF CLAPBOARDS PLAN DETAIL@ COINED CORNERS Scale: 1 1/2" = 1'-0" 1 A-5.0 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-6 April 23, 2012 EXISTING BATT INSULATION TO BE REMOVED WHERE READILY ACHIEVABLE FLASH WITH 2" CLOSED CELL, FINISH WITH 6" OPEN CELL FOAM INSULATION (TOTAL ASSEMBLY = R-40) NEW ACCESS HOLES FOR INSULATION, SEE 2A-4.0 TUCK HOUSE WRAP UNDER FRIEZE BOARD 2" +/-. EAVE SECTION WITHOUT WINDOW Scale: 1 1/2" = 1'-0" 2 A-5.0 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-7 April 23, 2012 EXISTING DEEP WINDOW SILL EXISTING DEEP SILL EXISTING ORNATE APRON EXISTING WALL SYSTEM: -PLASTER -ON LATHE -CAVITY WITH WALL STUDS -BRICK NOGGING BETWEEN POSTS -SHEATHING  HOUSE WRAP. TO LAP NEW FLASHING CUT DRIPEDGE ON UNDERSIDE OF ALL WINDOW SILLS TURN HOUSE WRAP BACK AND UNDER SILL FRAME EXPANDER MAKES RETURN FROM INSERT TO EXISTING SILL NEW SIDING SECOND FLOOR WINDOW SILL Scale: 1 1/2" = 1'-0" 3 A-5.0 REMOVE EXISTING WEIGHTS IN WEIGHT POCKETS, DRILL 2" HOLES THROUGH EXISTING WINDOW JAMB(TOP AND MIDDLE), BLOW CELLULOSE INSULATION IN AND PLUG BEFORE NEW WINDOW INSTALLATION, OR DETERMINE OTHER METHOD IN FIELD. INSULATION OF JAMB POCKETS KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-8 April 23, 2012 REPLACE WITH NEW WATER TABLE, BLOCK OUT WITH P.T. SHEATHING, UNDERCUT FOR DRIP BUGSCREEN AT BASE OF RAIN SCREEN NEW SIDING ON RAIN SCREEN MATT. ON EXISTING SHEATHING BOARDS LINE OF WALL BEYOND ADD NEW FIXED WINDOW INSERT, INSTALL 2" BACK FROM EXISTING FRAME REPLACE ROTTEN SECTIONS OF WINDOW FRAMESREMOVE EXISTING WINDOW, FOAM INSULATION TO EXISTING FRAME NEW BREAK METAL FLASHING @ SILL, JAMB, AND HEAD TO COVER EXISTING WINDOW FRAME. MATCH WINDOW COLOR SEAL WINDOW TO FRAME HOUSEWRAP TO LAP NEW FLASHING EXISTING SHEATHING REPLACE AS NEEDED NEW FLASHING UNDER NEW SIDING FRONT WING FIRST FLOOR AND FOUNDATION DETAIL Scale: 1 1/2" = 1'-0" 5 A-5.0 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-9 April 23, 2012 EXISTING 6 1/2"x 1 1/4" ORNATE WINDOW CASING AND MEDALLIONS EXISTING DEEP WINDOW HEAD WITH PANEL EXISTING EXTERIOR WINDOW CASING NEW SIDING  APPROX. CAVITY DEPTH (FIRST FLOOR FRONT WING ONLY) HOUSE WRAP. TO LAP NEW FLASHING EXTEND CAP FLASHING BEYOND OUTSIDE FACE OF VERTICAL TIM MIN. OF 1/2" TURN HOUSE WRAP BACK AND UNDER SILL SPLAYED WINDOW HEAD (DEEP) Scale: 1 1/2" = 1'-0" 7 A-5.0 1 A-5.0 CAP FLASHING EXTENDS MIN 1/2" BEYOND OUTSIDE EDGE OF TRIM. LAP HOUSEWRAP OVER HOUSE WRAP PUSHED UP UNDER EXISTING CORNICE MIN OF 2". HOUSE WRAP TURNS AGAINST EXISTING TRIM AT WINDOWS, COINING AND OTHER VERTICAL TRIM, MIN 3/8" AND SEALED AGAINST TRIM. HOUSE WRAP TURNS BACK AND UNDER SILL CAP FLASH AS POSSIBLE AT CORNICE. WINDOW ELEVATION DETAIL Scale: 1/2" = 1'-0" 9 A-5.1 KRAUS-FITCH ARCHITECTS, INC. 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MAHOME COMMUNITY PLANET APR. 23, 2012 SK-10 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-11 April 24, 2012 CONFERENCE ROOM CORRIDOR 100 C2 100 ST2 FIRE STAIR RAMP PORCH HALL 100 C3 SEMINAR ROOM 104 COPY 103 100 L LIFT LOBBY ACC. TOILET 100 T2 10 0 J 2 4' SCREEN PROJ. PROJ. EXISTING SOFFIT @ BREAK IN CEILING HEIGHT 9'-1" 9'-1" 9'-8" COORDINATE WITH OWNER FOR REMOVAL AND REINSTALLATION PROJECTOR, SCREEN AND SPEAKERS IN CONFRENCE AND SEMINAR ROOM 9'-1" 8' SCREENSP.SP. EXISTING FIXTURES TO REMAIN AT TOILET ROOM SO SO 9'-9' 1/2" 9'-9' 1/2" SO                                       NEW REC'D CANS SEE SKE-1 1 2 FIRST FLOOR REFLECTED CEILING PLAN Scale: 3/16" = 1'-0" 1 A-1.6 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-12 April 24, 2012 B03 B04 B05 CUT PLASTER @ FULL PERIMETER OF BASEMENT FOR INSULATION AT SILLDEMO BATHROOM WALLS, ETC. EXISTING PIERS TO REMAIN. LOCATE DEMOLITION FOR NEW FOOTING TO AVOID UNDERMINING. DEMO WHOLE WALL IF POSIBLE. EXPLORE FLOOR STRUCTURE TO DETERMINE EXTENT FEASIBLE. DEMO 30" WIDE PORTION OF WALL AS NEEDED FOR MECHANICAL. CUT TO CEILING HEIGHT AND INSTALL NEW STEEL HEADER TO CARRY MID SPAN OF JOISTS. CUT SECTIONS OF SLAB AND CEILING FOR NEW FOOTINGS AND POST, SEE STRUCTURAL AND ARCHITECTURL DRAWINGS.. CUT WALL ABOVE DOOR FOR DUCT PENETRATIONS CUT SLAB FOR PLUMBING PER P2.0 CUT PIT FOR EJECTOR PER DETAIL ON P3.0 DEMO PERIMETER OF CRAWL SPACE CEILING FOR INSULATING SILL. BASEMENT DEMO PLAN Scale: 1/4" = 1'-0" 1 D-1 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-13 April 24, 2012 CONFERENCE ROOM 105 CORRIDOR 100 C2 RAMP PORCH 100 P2 HALL 100 C3 100T1 OPEN UP CHASE WALL AS NEEDED ON CORRIDOR SIDE FOR NEW MEP INSTALLATIONS. DEMO PLUMBING FIXTURES REMOVE AND RELOCATE EXISTING DOOR FRAME AND HARDWARE. DEMO WALL FOR RELOCATION OF DOOR AND NEW POST. DEMO WALL FOR NEW POSTS REMOVE DOOR, AND TRIM RETAINING CURRENT RO. DEMO CABINETRY (4) EXTERIOR WALL PENETRATIONS FOR NEW SPRINKLER HEADS DEMO EDGE OF CEILING TO WALL ACCESS/CEILING INTERSECTION FOR INSULATION. 2 A-3.0 3 A-1.3 3 A-1.3 1 A-3.1 1 2 FIRST FLOOR DEMO PLAN Scale: 3/16" = 1'-0" 2 D-1 KRAUS-FITCH ARCHITECTS, INC. Environmentally inspired design 110 Pulpit Hill Road Amherst, Ma 01002 413-549-5799 Fax: 413-549-7918 www.krausfitch.com DEWEY HOUSE SMITH COLLEGE NORTHAMPTON, MA SK-14 April 24, 2012 200 ST2 200 ST1 200 ST2 20 0 J HALL 200 C2 OFFICE 215 NEW OFFICE 205 CU ST 200J-2 ALL PLASTER CEILINGS IN SECOND FLOOR TO REMAIN (EXCEPT AS NOTED OR DAMAGED). REPAIR ALL WATER DAMAGED AREAS AND SEAMS. PAINT ALL SURFACES 9'-10" 8'-0" LINE OF BREAK IN CEILING REPAIR CEILINGS IN AREA OF WALL REMOVAL AND NEW WALL CONSTRUCTIONREPAIR EXISTING PLASTER CEILING AFTER WALL DEMOS + SUSPENDED CEILING REMOVAL SO LMPP SO PP SO SO                                 SO LOCATE NEW SUSPENDED FIXTURES TO ONE SIDE OF EXTG SPRINKLER HEADS. MODIFY/ADD FIXTURES PER SKE-2 SECOND FLOOR REFLECTED CEILING PLAN Scale: 1/4" = 1'-0" 1 A-1.7