Loading...
120423-DEWEY PLANS-water fountain questionDE W E Y H O U S E - S M I T H C O L L E G E NO R T H A M P T O N , M A K R A U S - F I T C H AR C H I T E C T S , I N C . 11 0 P u l p i t H i l l R o a d Am h e r s t , M a 0 1 0 0 2 4 1 3 - 5 4 9 - 5 7 9 9 Fa x : 4 1 3 - 5 4 9 - 7 9 1 8 ww w . k r a u s f i t c h . c o m REVISIONS: DATENUMBER HO M E C O M M U N I T Y P L A N E T APRIL 18, 2012 100-A X-C 104-B 100-D 100L-B CONFERENCE ROOM 105 CORRIDOR 100 C2 100 ST2 FIRE STAIR 105-B RAMP PORCH 100 P2 100-C X-B 106-B 106-A 102-B PHILOSOPHY STUDY 102 100 ST1 FOYER 100 F 00 ST1 102-A 101-A 107-C HALL 100 C3 100-B X-A SEMINAR ROOM 104 SECRETARY 106 OFFICE 107 OFFICE 101 CORRIDOR 100 C1 105-A 107-B RAD. 107-A 104-A PATCH WALL @ DOOR REMOVAL COPY 103 100 L LIFT LOBBY MAIL 100 J1 REPAIR WALLS AROUND TUB AND WALL DEMO. INSTALL NEW FLOOR SINK, PLASTIC PARTITION, WIRE SHELVING (6 TOTAL, 12" DEEP VINYL COATED WIRE) AND MOP RACK 100T1 100-E EXISTING HEARTHS TO REMAIN. ADHERE LOSE TILES AS NEEDED REPLACE EXISTING TRASH SCREENING FENCE W/SIMILAR COMPOSIT MATERIAL ACC. TOILET 100 T2 10 0 J 2 107-C 1C / A - 6 . 0 1A / A - 6 . 0 NEW FLUSH WOOD THRESHOLD AND WOOD FLOOR WITHIN ROOM NEW T.S. 2B /A-6.0 A A EE F BB D FF-F FFF FF F C B B B B B ACCESSIBLE DRINKING FOUNTAIN   1 A-5.0 TYPICAL EXISTING ADJUSTABLE SHELVING TO BE REMOVED, LABELED, STORED AND REINSTALLED W/ONE COAT OF PAINT NEW T.S. NEW T.S. NEW T.S. NEW T.S. T.S. EXISTING WOOD THRESHOLD EXISTING WOOD THRESHOLD EXISTING RAILING CAP, BALLUSTERS AND NEWEL POST, RE-STAIN MODIFY EXISTING BOOKCASE TO ACCOMMODATE NEW CHASE. INSTALL NEW ADJUSTABLE SHELVES ABOVE TO SUPPLEMENT NEW CHASE WITH OFFSET AT CEILING TO ALIGN AT ROOM SIDE OF SECOND FLOOR TURN AND INSTALL REPLACEMENT BALUSTER (1), FINISHED TO MATCH EXISTING PROBABLE HEARTH LOCATION INSERT PIPES WITHIN EXISTING WALLS AS POSSIBLE (CHIMNEY ABANDONED AND CAN BE PENETRATED AS NEEDED) NEW CHASE LINE OF EXTERIOR WALL, ABOVE, SEE DWG A-3.0 FOR NOTES REGARDING INSULATION OF PROJECTING "BAY". PATCH WALLS AT REMOVAL TYPICAL F. C . F.C. F. C . RESET EXISTING MANTEL F. C . F.C. F.C.F.C.F.C.F.C. APPROX. LOCATION OF ERV DUCT FROM ABOVE. CONSTRUCT SOFFIT @ CEILING TO ACCOMODATE. EXISTING SHELVES TO BE REINSTALLED. NOTE THEY MAY NEED TRIMMING TO ACCOMMODATE NEW PIPE CHASE (WITH OFFSET AT CEILING) NEW BULLETIN BD. ADD AUTO DOOR OPERATOR TO THIS DOOR F F FF EXISTING WALL MOUNTED HANDRAILS, PAINT REBUILD CONCRETE STEPS AND REST RAILINGS RESET EXISTING HANDRAILS IN CONC. APPROX. LOCATION OF NEW PADDLE OPERATOR AND EXISTING KEY BOX TIMBER BEAM ABOVE 100L-A REMOUNT EXISTING FOLDING WHITE BOARD REBUILD WALL AS REQUIRED BY EXTENT OF ROT DISCOVERED. REPLACE WAINSCOT THIS WALL REINSTALL AUTOVISUAL EQUIP SHELF/AVOID FEEDSTRACK, TRIP AND BLACK BRD TO BE REMOVED AND REINSTALLED BY OWNER EXISTING T.S. TO REMAIN EXISTING ALUMINUM THRESHOLD TO REMAIN PATCH WALL @ RADIATOR REMOVAL GUT DRAWERS AND PATCH WALLS AND FLOORS REMOVE AND REINSTALL DIRECTORY (FOR WALL PAINTING) EXISTING BULLETIN BOARDS TO REMAIN. RELOCATE AS NEEDED FOR ELECTRICAL PANEL PADDLE ANNUC. PANEL P.S. P.S. F P.S. P.S.APPROXIMATE LINE OF TRUSSES @ ATTIC LEVEL NEW BEARING LOCATIONS, HOLD TO CORRIDOR SIDE OF WALLS. PATCH WALLS AND BASE BOARD AFTER INSTALLATION X-B TYPICAL NEW CHASES NEW T.S. BLACK BRD. TO REMAIN, PAINT AROUND USE EXISTING CHASE FOR NEW ERV DUCT RUNS. MAKE CUTS ON CORRIDOR SIDE, BEHIND NEW STORAGE AREA. NEW T.S. F.C. NEW CUSTODIAL SUPPLY CLOSET AND SHELVING (6) TOTAL SHELVES, 12" DEEP, VINYL COATED WIRE F.C. NEW BEARING LOCATIONS, PATCH WALL AFTER INSTALLATION CONTROLS 1B/ A-6.0 D REPAIR SPONGY FLOOR AREA- REQUIRES STRUCTURAL WORK IN BASEMENT CEILING (TBD.) 100L-A 100L-B NEW CHASE W/ APPLIED WAINSCOT TO MATCH. MODIFY EXISTING EXTERIOR WALLS TO CREATE 1-HR. FIRE ASSEMBLY @ WALL BETWEEN LIFT AND EXISTING BUILDING CUT WALL AND SNAKE PEX NEW CHASE RECE'D ELEC APPROX. LOCATION OF NEW POST WORK AROUND EXST. EQUIPMENT SHELF CHASE FOR (6) PIPES-OFFSET 3 ABOVE TOILET ROOM CEILING F. C . APPROX. LOCATION OF NEW SPRINKLER HEADS-AIR SEAL PENETRATIONS. EXISTING FOOT LIGHTS TO REMAIN APPROX. LOCATION OF NEW POST RELOCATE DOOR AND CHANGE DIRECTION OF SWING. NEW ERV CHASE CONFIRM 8" DEPTH WHEEL CHAIR- ACCESSIBLE SINK   2 A-1.1 NEW MECHANICAL CHASE 2A / A - 6 . 0 2C / A - 6 . 0 3 1 4 NEW CONCRETE POSTS AS NEEDED ADHERE ANY LOSE TILES 2 A-3.0 2 A-3.0 3 A-1.3 3 A-1.3 2 A-1.3 2 A-1.3 3 A-1.3 3 A-1.3 2 A-1.3 2 A-1.3 1 A-3.1 1 A-3.1 1 A-3.0 1 A-1.3 A-3.1 2 3 A-3.1 A B C D 1 2 4 6 3 4 5 6 1 2 3 5 FIRST FLOOR PLAN Scale: 1/4" = 1'-0" 1 A-1.1 FIRST FLOOR PLAN1 MODIFIED SHAFT WALL @ LIFT EQUAL TO GA FILE NO. WP 3615           ROOM SIDE LIFT SIDE 3 1 1/2" NON-STRUCTURAL BUILD-OUT VERTICAL STUDS (2) 5/8"1 1/2" NEW EXT. WALL @ LIFT ENCLOSURE 5 1/2" 3/4" CDX SHEATHING SIDING ON 3/4" FURRING ON BUILDING PAPER 11 1/4" 1 1/2" 2x6 STUDS ALIGN WITH BRICK SHELF (2) 5/8" F.C.    4 TYPICAL NEW INTERIOR WALL      BASEMENT EMERGENCY ELEC. ROOM EQUAL TO GA FILE NO. WP 4136    6"  2 1 1/2" RIGID INSULATION 3/4"   TYPICAL WALL TYPES Scale: 1" = 1'-0" 3 A-1.1 FIRE DOOR BY LIFT MANUFACTURER 5'-2 1/8" SHAFTWAY PIT 1 1/4"5 1/2" 1 1/4" 57 7/8" CLEAR 39" CLEAR WIDTH SH A F T W A Y P I T 5 1 / 2 " 1 1 / 4 " 1 1 / 4 " EXISTING WALLS TO BE MODIFIED TO CREATE 1-HR. CONSTRUCTION BY STRIPPING AND ADDING 1 LAYER OF 5/8" GYP. BD. TO FIRE RATED PLYWOOD. 3" 4' - 6 7 / 8 " OPEN UP EXISTING WALL AS NEEDED TO INSTALL NEW STRUCTURAL BLOCKING TO SUPPORT LIFT SHROUD/MACHINE HOUSING PER MANUFACTURER'S REQUIREMENTS. COORDINATE WITH STRUCTURAL DWGS. EXISTING WINDOW TO BE REMOVED AND INFILLED. SEE WALL DETAIL 3 AND DETAIL 4/A-3.1 FOR WALL CONSTRUCTION LOCATE BACK WALL OF LIFT TO COVER EXISTING WINDOW REMOVAL AND REPAIR WORK (TO MINIMIZE RESIDING WORK). 3 ENLARGED FIRST FLOOR LIFT PLAN Scale: 1/2" = 1'-0" 2 A-1.1 NOTE: GENERAL CONTRACTOR TO MEASURE EXISTING WALL CONSTRUCTION TO DETERMINE DOOR JAMB DETAIL. GENERAL NOTES FOR ELECTRICAL INSTALLATIONS: SEE DEMO PLANS FOR APPROXIMATE EXTENT OF AREAS OF WALLS + CEILING TO BE OPENED. PATCH TO MATCH. A-1.1 200-G 200-H 215-C 215-A 201-B 201-A 210-B 212-B 211-B 213-B 214-B 200-K ST-201-A 215-C 215-B 203-B 203-C 202-B OFFICE 214 OFFICE 213 OFFICE 201 UP 203A 200 ST2 HALL 200 C3 (O P E N T O B E L O W ) 200 ST1 200 ST2 200 ST3 200-C 206-B 200-F 200-D 200-E 20 0 J 215-D CORRIDOR 200 C1 OFFICE 212 OFFICE 206 OFFICE 207 HALL 200 C2 OFFICE 215 OFFICE 203 OFFICE 204 OFFICE 211OFFICE 210 OFFICE 209 OFFICE 202 200L-A 202-A 207-B 200-A 203-A 205- A 200-A LIFT ENTRY 208-A 200-I 200-J 1' - 8 " NEW OFFICE 205 NEW MTG. RM./FLEX SPACE 208 NEW LOUNGE 200 L UNISEX HP TOILET 2OOT2 7'-6" CLEAR MIN.8'-2" +/-        215-D INSTALL NEW NEW MAGNETIC HOLD OPEN @ EXISTING GLASS PARTITION DOOR REPAIR BROKEN/CRACKED MANTEL CASEWORK ROOF BELOW 5A/ A-6.0 EXISTING BULLETIN BOARDS TO REAMIN PROBABLE LOCATION OF EXISTING HEARTH RESET TILE AS NEEDED. H G G K GGGGH KKKKKK K J G K J K-TKK G G HH INSTALL NEW HANDRAIL NEW T.S. NEW T.S. NEW T.S. NEW T.S. EXISTING ALUMINUM THRESHOLD TYPICAL TRANSITION, CPT. TO WOOD W/O STRIP OR THRESHOLD EXISTING WOOD THRESHLD EXISTING WOOD THRESHLDK TYPICAL HEARTH RESET TILE AS NEEDED F. C . SHORTEN BOOK SHELVES AND MOVE STANDARD APPROX 12", FIRMLY SECURE STANDARD TO FRAMING NEW ERV DUCTS IN PROBABLE EXISTING CHASE LOCATION F. C . F.C. F. C . F.C.F.C.F.C.F.C.F.C. F. C . F.C.F.C. F. C . REMOVE BOTTOM TWO SHELVES TO PROVIDE ROOM FOR NEW FAN COIL NEW ERV CHASE NEW CHASE FOR ERV NEW ERV CHASE + PIPE NEW ERV CHASE NEW RADIATOR UNISEX HP TOILET 200 T1 4A / A - 6 . 0 4B/ A-6.04C / A - 6 . 0 KITCHENETTE NEW SMALL CHASE FOR SINK VENT APPROXIMATE LINE OF TRUSSES @ ATTIC LEVEL RELOCATE SHELVING FROM FORMER OFFICE @ 200 L. FIRMLY SECURE STANDARDS TO FRAMING 203-A NEW T.S. CU ST 200J-2 F.C. F. C .EXISTING BALLISTER TO REMAIN, RE-STAIN APPROX. LOCATION OF NEW POSTS (AS DIRECTLY UNDER PURLINS AS POSSIBLE) FROM TRUSS TO FOUNDATION APPOX. LOCATION OF NEW POST. BURY IN NEW WALL. NEW CUSTODIAL CLOSET W/NEW FLOOR SINK AND VINYL FLOORING. NEW T.S. F. C . DRINKING FOUNTAIN 214-A213-A212-A211-A210-A209-A J TYPE WINDOWS (3 TOTAL). REQUIRE NEW SILL AND APRON. J NEW POST, EXPOSE TO CORRIDOR SIDE IF NEEDED. PATCH FINISHES REPLACE ALL OFFICE DOORS @ BACK CORRIDOR. DETERMINE FEASIBILITY OF WIDENING ROUGH OPENING PRIOR TO ORDERING NEW DOORS. LINE OF BREAK IN CEILING. DETERMINE IN FEILD NEW BEARING LOCATIONS, PATCH WALL AFTER INSTALLATION NEW POST F. C . MEP: REVIEW LOCATION OF PIPE CHASE BELOW NEW ERV AND PIPE CHASE IN CLOSET NEW REC'D ELEC PANEL PIPE CHASE NEW REC'D ELEC PANEL LOCATE DUCT IN WALL, ADJUST FOR CONFLICTS, PATCH. TYP. ERV DUCT, VERIFY NO CONFLICTS WITHIN CLOSETS, UNFINISHED CHASE WALLS, SEAL FLOOR PENETRATIONS 204-A RETAIN AND REUSE ROSETTES AND TRIM AS POSSIBLE. MATCH NEW. RETAIN SUFFICIENT CHASE AREA TO ENCLOSE EXISTING PLUMBING RISER REMOVE EXISTING WAINSCOT AND PATCH WALLS REPLACE EXIST'G STAIRS WITH METAL SHIPS LADDER 207-A 206-A 6' - 0 " C L E A R M I N .   2 A-1.2 200-B NEW POST, BURY INTO NEW WALLS. 2 A-3.0 2 A-3.0 3 A-1.3 3 A-1.3 2 A-1.3 2 A-1.3 3 A-1.3 3 A-1.3 2 A-1.3 2 A-1.3 1 A-3.1 1 A-3.1 1 A-3.0 1 A-1.3 A-3.1 2 3 A-3.1 A B C D 1 2 4 6 3 4 5 6 1 2 3 5 SECOND FLOOR PLAN Scale: 1/4" = 1'-0" 1 A-1.2 A-1.2 DE W E Y H O U S E - S M I T H C O L L E G E NO R T H A M P T O N , M A K R A U S - F I T C H AR C H I T E C T S , I N C . 11 0 P u l p i t H i l l R o a d Am h e r s t , M a 0 1 0 0 2 4 1 3 - 5 4 9 - 5 7 9 9 Fa x : 4 1 3 - 5 4 9 - 7 9 1 8 ww w . k r a u s f i t c h . c o m REVISIONS: DATENUMBER HO M E C O M M U N I T Y P L A N E T APRIL 18, 2012 SECOND FLOOR PLANAA'B C D FE FLUSH WOOD PARTICLE CORE, 5 PLYEXISTING ONLY EXISTING ONLY EXISTING + NEW SIMPSON 84 (SOLID WOOD,PANELED)EXISTING ONLY EXISTING + NEW SIMPSON 44 (SOLID WOOD, PANELED)EXISTING D' FLUSH STEEL FIRE RATED AT BASEMENT DOORS Scale: 1/4" = 1'-0" 3 A-1.1 FIRE DOOR BY LIFT MANUFACTURER STRIP SIDING AND ADD 2 LAYERS OF 5/8" GYP. DB. COORDINATE ATTACHMENT POINTS, SEE STRUCTURAL DWGS EXISTING WINDOW TO BE REMOVED AND INFILLED. NEW LOUVER THRU WALL, SEE MECH. 1-HR. FIRE RATED ASSEMBLY ENLARGED SECOND FLOOR LIFT PLAN Scale: 1/2" = 1'-0" 2 A-1.1 GENERAL NOTES FOR ELECTRICAL INSTALLATIONS: SEE DEMO PLANS FOR APPROXIMATE EXTENT OF AREAS OF WALLS + CEILING TO BE OPENED. PATCH TO MATCH. 300-A 305-A 306-A 304-A 304-B 305-B 306 300-C 301-A 302-A 303-A 300-B 300 ST3 300-C 303-B OFFICE 306 OFFICE 305OFFICE 304 OFFICE 303 OFFICE 302 300 T 30 0 S T 2 OFFICE 301 LINE OF TRUSS TO BE REINFORCED PER DETAILS 2/S-1.0 ATTIC 300A REPAIR WALLS AROUND TUB AND WALL DEMO. INSTALL NEW FLOOR SINK, PLASTIC PARTITION, SHELVING AND CUSTODIAL MOP RACK REPAIR WALLS AT TOILETRY CABINET DEMO. OPEN UP ATTIC AREA OVER STAIR TO EXPOSE WINDOW AND CREATE HIGH CEILING. MAINTAIN PLATFORM OR HEADER AS NEEDED FOR STRUCTURAL CONSIDERATION. BUT NO WALLS EXISTING HATCH ACCESS TO REMAIN, ABOVE L NNNNN NNN N M P Q ROOF BELOW LINE OF EXISTING TRUSS WITH NEW BEARING POINTS BELOW TO FOUNDATION TYPICAL TRANSITION, CPT. TO WOOD W/O STRIP OR THRESHOLD EXISTING ALUMINUM THRESHOLD STAIR- PAINT FLOORS BUT NOT WALLS LINE OF NEW DORMER AIR SEAL AROUND CHIMNEY PENETRATIONS @ FLOOR AND ROOF LEVELS       EXISTING STEP IN FLOOR ELEVATION TO REMAIN AS NEEDED. MAINTAIN PARTIAL HEIGHT PARTITION AS NEEDED, FOR GUARD RAIL APPROXIMATE LOCATION OF DUCTS DOWN TO SERVE LOWER LEVELS INSTALL NEW MAGNETIC HOLD OPEN AT FLOOR FOR EXISTING DOOR APPROX. LOCATION OF NEW POSTS SHORTEN SHELVES AS NEEDED TO ACCOMODATE F.C. UNIT LINES OF APPROX. TRUSS LOCATIONS. REINFORCE PER STRUCTURAL DRAWINGS, AND CREATE NEW BEARING POINTS TO FOUNDATION NEW FOOTING LINE OF TRUSS OVER EXTERIOR WALL APPROXIMATE LOCATION OF QUEEN POST, TYPICAL F. C . F. C . F.C. F.C. F.C. TB D I N F I E L D AP P R O X . 8 ' - 0 " O . C . LOCATE DUCT IN WALL, ADJUST FOR CONFLICTS. ADJUST LOCATION OF DUCTS AND CHASE TO WORK AROUND NEW POST. CONFIRM WALL PENETRATION WITH STRUCTURAL REQUIREMENTS. DUCT IN WALL (CUT AND PATCH) DUCT IN WALL (CUT AND PATCH) EXISTING STAIR AND ENCLOSURE TO REMAIN APPROCIMATE LOCATION OF AIR HANDLER 3'-1" +/-3'-1" +/-3'-1" +/- PATCH FLOOR AT FORMER CHIMNEY PENETRATION 11'-4" +/- NEW DORMER 3"3" VERIFY ALL ROUGH OPENINGS WITH WINDOW MFR. CUT HOLES IN EXTERIOR WALL TOO INSERT LVLS. FULL WINDOW REPLACEMENT (INCLUDING FRAME AND TRIM). INSTALL NEW HANDRAIL S S S O O O NEW REC'D ELEC PANEL F. C . REPLACE WOOD BOARDS @ WALL W/PLASTER NEW T.S. NEW RADIATOR 2 A-3.0 2 A-3.0 3 A-1.3 3 A-1.3 2 A-1.3 2 A-1.3 3 A-1.3 3 A-1.3 2 A-1.3 2 A-1.3 1 A-3.1 1 A-3.1 1 A-3.0 1 A-1.3 A-3.1 2 3 A-3.1 A B C D 1 2 4 6 3 4 5 6 1 2 3 5 THIRD FLOOR PLAN Scale: 1/4" = 1'-0" 1 A-1.3 DE W E Y H O U S E - S M I T H C O L L E G E NO R T H A M P T O N , M A K R A U S - F I T C H AR C H I T E C T S , I N C . 11 0 P u l p i t H i l l R o a d Am h e r s t , M a 0 1 0 0 2 4 1 3 - 5 4 9 - 5 7 9 9 Fa x : 4 1 3 - 5 4 9 - 7 9 1 8 ww w . k r a u s f i t c h . c o m REVISIONS: DATENUMBER HO M E C O M M U N I T Y P L A N E T APRIL 18, 2012 THIRD FLOOR PLAN A-1.3 GENERAL NOTES FOR ELECTRICAL INSTALLATIONS: SEE DEMO PLANS FOR APPROXIMATE EXTENT OF AREAS OF WALLS + CEILING TO BE OPENED. PATCH TO MATCH.