32C-219 (27) O�TtIAMp�O �888AChlTStttS n" ;y DEPARTMENT OF BUILDINTG INSPECTIONS INSPECTOR 212 Main Street • Municipal Building Northampton, MA 01060 October 19, 1997 ServiceNet Inc 123 Hawley Street Northampton, MA 01060 Subject: Overnight cot program Dear Ms. Mueller, The inspection that was conducted at 123 Hawley Street on Friday October 16 revealed several conditions that must be corrected before the cot program may open on Nov 1. The Department of Fire Services Code Compliance Officer and Northampton Fire Chief and I agree that the following items must be corrected, there are: a. Smoke detectors shall be hardwired and interconnected and tied into your present central system and alarm must meet national decibel sound requirement. One smoke detector shall be placed at bottom of basement stairs. b. Exits signs placed as per our discussion (3). c. Dryer vent (plastic) replaced with flexible metal duct material. d. The area in basement directly below shelter must have ceiling sheetrocked with 5/8" fire code sheetrock or a rated assembly providing a one hour rating and all penetrations sealed. e. 3 - 10 lb. fire extinguishers mounted and identified at locations specified by fire department. f. "NO Smoking" signs placed within facility. If you have further questions please contact me a 597-1240. Thank you. Sincerely, Anthony Patillo Building Commissioner --a City of Northampton CC: Chief Duggan, Deputy Chief Driscoll CITY OF NORTHAMPTON . MASSACHUSETTS CITY HALL I 210 Main Street Northampton, MA 01.060 (413)586-6950 FAX:(413) 587-1264(Main Bldg. ) FAX TRANSMITTAL DATE: FAX TO TELEPHONE NUMBER: FROM: Phone Number: 413—.587-1240 FAX Number: 413— 587-1272 (Annex) PAGES, INCLUDING THIS SHEET: Anthony L. Patillo Building Commissioner Zoning Enforcement Officer 212 Main Street 587-1240 Northampton,MA 01060 Fax 587-1272