26 Mark Warner Drive approval letter 2013-04-10Saloomey Construction Tony Balotti PO Box 1203 Westfield, MA 01086 April 10, 2013 Map Block: 16B-001-026 Location: 26 Mark Warner Drive Mr Balotti: The plans for the Single Family Residence dated 2-13-2013 have been approved as noted; Structure must conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. Energy aspects must comply the stretch energy code. (appendix 115AA) All sill plates must be properly attached with a minimum of two bolts per section. A complete window and header schedule is required. Initial and final HERS ratings, duct blast test results. Smoke and CO detectors as required per code. All framing materials which are not code prescriptive must have engineering. LVLs I-joist and or Floor Truss Roof truss HVAC system requires a sheet metal permit. Equipment data with sizing and efficiencies Line drawing with CFM amounts for supplies and returns These items must be submitted to the building department for approvals before a rough inspection can occur. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller@northamptonma.gov Thank you for your cooperation in this matter. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement cmiller@northamptonma.gov