Manual J calcs #26
Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 1...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE Job:Load Short Form MARCH 6,2013Date:Entire House By: Project Information For: Design Information InfiltrationClgHtg SimplifiedMethod870Outside db (°F) TightConstruction quality7570Inside db (°F)1 (Average)Fireplaces1270Design TD (°F)M-Daily range 5050Inside humidity (%)2451Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade TradeModelCondGAMA ID CoilARI ref no.Efficiency 80 AFUE Efficiency 0 SEERHeating input Btuh0 Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0Actual air flow cfm1736 Actual air flow cfm1736Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.049Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.95 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF(ft²)(Btuh)(Btuh)(cfm)(cfm) BASEMENT 1985 18724 5090 470 250FIRST FLOOR 1889 30580 23591 768 1158SECOND FLOOR 1552 19823 10756 498 528 Entire House 5426 69127 35366 1736 1736Other equip loads 0 0Equip. @ 0.92 RSM 32537Latent cooling 1843 TOTALS 5426 69127 34380 1736 1736 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 2...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE Job:Load Short Form MARCH 6,2013Date:BASEMENT By: Project Information For: Design Information InfiltrationClgHtg SimplifiedMethod870Outside db (°F) TightConstruction quality7570Inside db (°F)1 (Average)Fireplaces1270Design TD (°F)M-Daily range 5050Inside humidity (%)2451Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/aModeln/a Cond n/aGAMA ID n/a Coil n/aARI ref no.n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF(ft²)(Btuh)(Btuh)(cfm)(cfm) CELLAR 1985 18724 5090 470 250 BASEMENT 1985 18724 5090 470 250Other equip loads 0 0Equip. @ 0.92 RSM 4683Latent cooling 105 TOTALS 1985 18724 4788 470 250 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 3...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE Job:Load Short Form MARCH 6,2013Date:FIRST FLOOR By: Project Information For: Design Information InfiltrationClgHtg SimplifiedMethod870Outside db (°F) TightConstruction quality7570Inside db (°F)1 (Average)Fireplaces1270Design TD (°F)M-Daily range 5050Inside humidity (%)2451Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/aModeln/a Cond n/aGAMA ID n/a Coil n/aARI ref no.n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF(ft²)(Btuh)(Btuh)(cfm)(cfm) MASTER 323 4413 2835 111 139SUN14462654757157233HALL440000BATH900000BED2180345814238770LIV2525920891103FOYER10717527514437DINING176196917804987MUSIC165277211467056BREAK10850884456128219KIT1801321279433137LAUNDRY120348115598777 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 4...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE FIRST FLOOR 1889 30580 23591 768 1158Other equip loads 0 0Equip. @ 0.92 RSM 21704 Latent cooling 1496 TOTALS 1889 30580 23200 768 1158 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 5...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE Job:Load Short Form MARCH 6,2013Date:SECOND FLOOR By: Project Information For: Design Information InfiltrationClgHtg SimplifiedMethod870Outside db (°F) TightConstruction quality7570Inside db (°F)1 (Average)Fireplaces1270Design TD (°F)M-Daily range 5050Inside humidity (%)2451Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/aModeln/a Cond n/aGAMA ID n/a Coil n/aARI ref no.n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF(ft²)(Btuh)(Btuh)(cfm)(cfm) MSTRBTH 96 1922 665 48 33STUDIO69786744935218242OFFICE42043443337109164FINISHED STORAGE 339 4884 1819 123 89 SECOND FLOOR 1552 19823 10756 498 528Other equip loads 0 0Equip. @ 0.92 RSM 9895Latent cooling 241 TOTALS 1552 19823 10137 498 528 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 1...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE Job:Project Summary MARCH 6,2013Date:Entire House By: Project Information For: Notes: Design Information Springfield Westover AFB, MA, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F0 Outside db °F87Inside db °F70 Inside db °F75Design TD °F70 Design TD °F12Daily range MRelative humidity %50Moisture difference gr/lb24 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh66866 Structure Btuh34551DuctsBtuh2261DuctsBtuh815Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0HumidificationBtuh0BlowerBtuh0PipingBtuh0Equipment load Btuh69127 Use manufacturer's data nRate/swing multiplier 0.92InfiltrationEquipment sensible load Btuh32537 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Tight1 (Average)Fireplaces Structure Btuh928DuctsBtuh916CoolingHeatingCentral vent (0 cfm)Btuh054265426Area (ft²)Equipment latent load Btuh18433891038910Volume (ft³)Air changes/hour 0.050.13 Equipment total load Btuh34380Equiv. AVF (cfm)3285 Req. total capacity at 0.70 SHR ton3.9 Heating Equipment Summary Cooling Equipment Summary Make MakeTradeTradeModelCondGAMA ID CoilARI ref no.Efficiency 80 AFUE Efficiency 0 SEERHeating input Btuh0 Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0Actual air flow cfm1736 Actual air flow cfm1736Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.049Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.95 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 2...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE Job:Project Summary MARCH 6,2013Date:BASEMENT By: Project Information For: Notes: Design Information Springfield Westover AFB, MA, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F0 Outside db °F87Inside db °F70 Inside db °F75Design TD °F70 Design TD °F12Daily range MRelative humidity %50Moisture difference gr/lb24 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh18724 Structure Btuh5090DuctsBtuh0DuctsBtuh0Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0HumidificationBtuh0BlowerBtuh0PipingBtuh0Equipment load Btuh18724 Use manufacturer's data nRate/swing multiplier 0.92InfiltrationEquipment sensible load Btuh4683 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Tight1 (Average)Fireplaces Structure Btuh105DuctsBtuh0CoolingHeatingCentral vent (0 cfm)Btuh019851985Area (ft²)Equipment latent load Btuh10579407940Volume (ft³)Air changes/hour 0.050.13 Equipment total load Btuh4788Equiv. AVF (cfm)617 Req. total capacity at 0.70 SHR ton0.6 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTraden/a Trade n/aModeln/a Cond n/aGAMA ID n/a Coil n/aARI ref no.n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 3...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE Job:Project Summary MARCH 6,2013Date:FIRST FLOOR By: Project Information For: Notes: Design Information Springfield Westover AFB, MA, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F0 Outside db °F87Inside db °F70 Inside db °F75Design TD °F70 Design TD °F12Daily range MRelative humidity %50Moisture difference gr/lb24 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh28506 Structure Btuh22712DuctsBtuh2074DuctsBtuh879Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0HumidificationBtuh0BlowerBtuh0PipingBtuh0Equipment load Btuh30580 Use manufacturer's data nRate/swing multiplier 0.92InfiltrationEquipment sensible load Btuh21704 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Tight1 (Average)Fireplaces Structure Btuh619DuctsBtuh878CoolingHeatingCentral vent (0 cfm)Btuh018891889Area (ft²)Equipment latent load Btuh14961700117001Volume (ft³)Air changes/hour 0.050.12 Equipment total load Btuh23200Equiv. AVF (cfm)1335 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTraden/a Trade n/aModeln/a Cond n/aGAMA ID n/a Coil n/aARI ref no.n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2013-Mar-08 13:42:29Right-Suite® Universal 7.1.19 RSU11776 Page 4...INWHOLESALE\Documents\Heat'n'cool loads\ACTIONBEARHILL#26A.rup Calc = MJ8 Orientation = SE Job:Project Summary MARCH 6,2013Date:SECOND FLOOR By: Project Information For: Notes: Design Information Springfield Westover AFB, MA, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F0 Outside db °F87Inside db °F70 Inside db °F75Design TD °F70 Design TD °F12Daily range MRelative humidity %50Moisture difference gr/lb24 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh19636 Structure Btuh10721DuctsBtuh187DuctsBtuh35Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0HumidificationBtuh0BlowerBtuh0PipingBtuh0Equipment load Btuh19823 Use manufacturer's data nRate/swing multiplier 0.92InfiltrationEquipment sensible load Btuh9895 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Tight1 (Average)Fireplaces Structure Btuh204DuctsBtuh38CoolingHeatingCentral vent (0 cfm)Btuh015521552Area (ft²)Equipment latent load Btuh2411396913969Volume (ft³)Air changes/hour 0.050.14 Equipment total load Btuh10137Equiv. AVF (cfm)1333 Req. total capacity at 0.70 SHR ton1.2 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTraden/a Trade n/aModeln/a Cond n/aGAMA ID n/a Coil n/aARI ref no.n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 Job #: Performed for: Scale: 1 : 109 Page 1Right-Suite® Universal7.1.19 RSU117762013-Mar-08 13:43:20...ool loads\ACTIONBEARHILL#26A.... Level 1 MASTER SUN MSTRBTH HALL BATH BED2 LIV FOYER DINING MUSIC BREAK KIT LAUNDRY Job #: Performed for: Scale: 1 : 109 Page 2Right-Suite® Universal7.1.19 RSU117762013-Mar-08 13:43:20...ool loads\ACTIONBEARHILL#26A.... SECOND FINISHED STORAGE OFFICE STUDIO Job #: Performed for: Scale: 1 : 109 Page 3Right-Suite® Universal7.1.19 RSU117762013-Mar-08 13:43:20...ool loads\ACTIONBEARHILL#26A.... BASEMENT CELLAR