31A-279 (2) For more information or to place an order call 413-584-1634 Page: 2
HTM Heat HTM Cool Area or# BTU Loss BTU Gain
North West wall 15 x 8,frame or veneer, R11 Insulation 6.3 2.6 111 699 289
1 Window Double Glass 36 x 36 in.,No Shade In&Out 40.6 53 9 365 477
North East wall 10 x 8, frame or veneer, R11 Insulation 6.3 2.6 68 428 177
1 Window Double Glass 36 x 48 in.,No Shade In&Out 40.6 53 12 487 636
South East wall 15 x 8,frame or veneer,R11 Insulation 6.3 2.6 105 662 273
1 Window Double Glass 36 x 60 in.,No Shade In&Out 40.6 65 15 609 975
Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 139 20.6 36 5005 743
Latent heat infiltration allowance for wall/ceiling openings 0 19.4 36 0 698
Allowance for appliances and motors 0.0 2.0 600 0 1200
Total BTU heat loss and sensible gain(does not include 698 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 186 13302 3570
The following is required for forced air heating or air conditioning:
2 Branch ducts-(6 in.round)or(7 in. oval)or(3-1/4 x 10 wall stack)
2#661 14 x 4 sidewall registers or 2#411 4 x 12 floor diffusers
2#16 8 in. round ceiling diffuser or 2#24 6 x 6 in. square diffusers
2#650 10 X 6 in. return air grill,or two 3-1/4 X 14 in.wall returns
Living Room Heat Cool Area Loss Gain
Floor over enclosed crawl space or unheated basement,No ins. 10.9 0 300 3270 0
Ceiling under conditioned room 0 0 300 0 0
North West wall 20 x 8,frame or veneer, R11 Insulation 6.3 2.6 121 762 315
1 Window Double Glass 36 x 60 in.,No Shade In&Out 40.6 53 15 609 795
1 Window Double Glass 6 x 84 in.,No Shade In&Out 40.6 53 4 142 186
1 Door Solid Wood,No Storm Door 36 x 80 in. 32.2 13.2 20 644 264
South West wall 15 x 8,frame or veneer,R11 Insulation 6.3 2.6 108 680 281
1 Window Double Glass 30 x 60 in.,No Shade In&Out 40.6 65 12 508 812
South East wall 9 x 8, frame or veneer, R11 Insulation 6.3 2.6 60 378 156
1 Window Double Glass 30 x 60 in.,No Shade In&Out 40.6 65 12 508 812
Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 58.7 8.7 63 3696 550
Latent heat infiltration allowance for wall/ceiling openings 0 8.2 63 0 517
Total BTU heat loss and sensible gain(does not include 517 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 165 11757 4171
The following is required for forced air heating or air conditioning:
2 Branch ducts-(6 in.round)or(6 in. oval)or(3-1/4 x 8 wall stack)
2#661 12 x 4 sidewall registers or 2#411 4 x 10 floor diffusers
2#16 6 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers
2#650 10 X 6 in.return air grill,or two 3-1/4 X 14 in.wall returns
Whole building
System Design:
Supply trunk duct is 18 x 8 reduced 2 inces every 30 feet
Return duct is 18 x 8 reduced 2 inces every 30 feet
If CFM of selected air handler is greater than 800, increase duct size -
Heat Loss/Gain Calculation by Schneider Plg. & Htg. Inc.
For more information or to place an order call 413-584-1634 Page: 1
File Name: 88WASHI -Residential Calculation Winter: 70 degrees difference
Date: 7/27/2013 Summer:25 degrees difference
Reference: ccb 88 washington HTM Heat HTM Cool Area or# BTU Loss BTU Gain
Level 1
Den Heat Cool Area Loss Gain
Floor over enclosed crawl space or unheated basement,No ins. 10.9 0 176 1918 0
Ceiling under conditioned room 0 0 176 0 0
South West wall 16 x 8,frame or veneer, Rl 1 Insulation 6.3 2.6 116 731 302
1 Window Single Glass 30 x 60 in.,No Shade In&Out 77 82 12 962 1025
South East wall 11 x 8,frame or veneer,R11 Insulation 6.3 2.6 46 290 120
1 Window Double Glass 72 x 84 in.,No Shade In& Out 40.6 65 42 1705 2730
North East wall 7 x 8,frame or veneer,R11 Insulation 6.3 2.6 56 353 146
Infiltration, Loss 1.2 ac/hr, gain 0.5 ac/hr 39.9 6.1 54 2156 330
Latent heat infiltration allowance for wall/ceiling openings 0 5.7 54 0 310
Total BTU heat loss and sensible gain (does not include 310 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 158 8521 4653
The following is required for forced air heating or air conditioning:
2 Branch ducts- (6 in. round)or(6 in. oval)or(3-1/4 x 8 wall stack)
2 #661 12 x 4 sidewall registers or 2#411 4 x 10 floor diffusers
2#16 6 in. round ceiling diffuser or 2#24 6 x 6 in. square diffusers
1 #650 10 X 6 in.return air grill, or one 3-1/4 X 14 in. wall returns
entry Heat Cool Area Loss Gain
Concrete slab on grade,No edge ins. 56.7 0 45 2552 0
Ceiling under conditioned room 0 0 168 0 0
North East wall 15 x 9,frame or veneer, R11 Insulation 6.3 2.6 98 617 255
1 Window Double Glass 48 x 48 in.,No Shade In& Out 40.6 53 16 650 848
l Window Double Glass 6 x 82 in.,No Shade In&Out 40.6 53 3 139 181
1 Door Solid Wood,No Storm Door 32 x 80 in. 32.2 13.2 18 580 238
South East wall 3 x 8, frame or veneer,R11 Insulation 6.3 2.6 24 151 62
South West wall 15 x 8,frame or veneer, R11 Insulation 6.3 2.6 96 605 250
1 Window Double Glass 6 x 84 in.,No Shade In&Out 40.6 65 4 142 228
1 Door Solid Wood,No Storm Door 36 x 80 in. 32.2 13.2 20 644 264
Cold wall 12 x 8 ft,Frame,R11 insulation 4.9 1.8 96 470 173
Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 8.8 1.3 61 539 82
Latent heat infiltration allowance for wall/ceiling openings 0 1.3 61 0 78
Total BTU heat loss and sensible gain(does not include 78 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 104 7443 2581
The following is required for forced air heating or air conditioning:
2 Branch ducts- (5 in. round)or(5 in. oval)or(3-1/4 x 8 wall stack)
2 #661 10 x 4 sidewall registers or 2#411 2-1/4 x 14 floor diffusers
2 #16 6 in. round ceiling diffuser or 2#24 6 x 6 in. square diffusers
1 #650 10 X 6 in. return air grill,or one 3-1/4 X 14 in.wall returns
Kitchen Heat Cool Area Loss Gain
Floor over enclosed crawl space or unheated basement,No ins. 10.9 0 405 4414 0
Ceiling under conditioned room 0 0 405 0 0
For more information or to place an order call 413-584-1634 Page: 2
HTM Heat HTM Cool Area or# BTU Loss BTU Gain
North wall 13 x 5,frame or veneer,R19 Insulation 4.2 1.7 65 273 110
West wall 19 x 10,frame or veneer,R19 Insulation 4.2 1.7 165 693 281
1 Window Double Glass 57 x 48 in.,No Shade In&Out 40.6 72 19 771 1368
1 Window Double Glass 24 x 36 in.,No Shade In&Out 40.6 72 6 244 432
Total BTU heat loss and sensible gain(does not include 129 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 132 4316 3882
The following is required for forced air heating or air conditioning:
2 Branch ducts-(5 in. round)or(5 in. oval)or(3-1/4 x 8 wall stack)
2#661 10 x 4 sidewall registers or 2#411 2-1/4 x 14 floor diffusers
2#16 6 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers
1 #650 10 X 6 in.return air grill,or one 3-1/4 X 14 in. wall returns
Whole building
System Design:
Supply trunk duct is 18 x 8 reduced 2 inces every 30 feet
Return duct is 18 x 8 reduced 2 inces every 30 feet
If CFM of selected air handler is greater than 800, increase duct size
Grand total BTU heat loss and 13498 BTU sensible+388 BTU latent heat gain CFM Loss Gain
CFM at recommended maximum trunk velocity of 1000 FPM 459 19633 13886
Heat Loss/Gain Calculation by Schneider Plg. & Htg. Inc.
For more information or to place an order call 413-584-1634 Page: 1
File Name: 88WASHI -Residential Calculation Winter: 70 degrees difference
Date: 8/18/2013 Summer:20 degrees difference
Reference: garage add HTM Heat HIM Cool Area or# BTU Loss BTU Gain
Level 1
1 Heat Cool Area Loss Gain
Concrete slab on grade, 1 inch edge ins. R5 28.7 0 54 1550 0
Ceiling under unventilated roof,R30 Insulation(10"), Dark roof 2.4 1.7 150 360 255
South wall 17 x 10, frame or veneer,R19 Insulation 4.2 1.7 122 512 207
2 Windows Double Glass 33 x 60 in.,No Shade In&Out 40.6 38 28 1116 1045
1 Door Solid Wood,No Storm Door 36 x 80 in. 32.2 12.7 20 644 254
North wall 13 x 10, frame or veneer, R19 Insulation 4.2 1.7 92 386 156
3 Windows Double Glass 30 x 60 in.,No Shade In&Out 40.6 23 38 1522 862
North wall 22 x 10, frame or veneer,R19 Insulation 4.2 1.7 220 924 374
Cold wall 19 x 10 ft,Frame,RI1 insulation 4.9 1.7 190 931 323
Infiltration,Loss 0.4 ac/hr, gain 0.2 ac/hr 3.6 0.5 86 308 44
Latent heat infiltration allowance for wall/ceiling openings 0 0.6 86 0 52
Total BTU heat loss and sensible gain(does not include 52 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 120 8253 3520
The following is required for forced air heating or air conditioning:
2 Branch ducts-(5 in. round)or(5 in. oval)or(3-1/4 x 8 wall stack)
2#661 10 x 4 sidewall registers or 2#411 2-1/4 x 14 floor diffusers
2#16 6 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers
1 #650 10 X 6 in. return air grill, or one 3-1/4 X 14 in.wall returns
Level 2
2 Heat Cool Area Loss Gain
Floor over ventilated crawl space or garage, R30 ins. 2.6 0.7 285 741 199
Ceiling under unventilated roof, R30 Insulation(10"), Dark roof 2.4 1.7 295 708 502
Skylight,9 sq ft, double pane,45 degrees 46.6 117 9 419 1053
South wall 19 x 10,frame or veneer,R19 Insulation 4.2 1.7 165 693 281
l Window Double Glass 60 x 60 in.,No Shade In&Out 40.6 38 25 1015 950
East wall 15 x 10,frame or veneer,R19 Insulation 4.2 1.7 114 479 194
1 Window Double Glass 60 x 86 in.,No Shade In&Out 40.6 72 36 1455 2580
North wall 19 x 5,frame or veneer,R19 Insulation 4.2 1.7 95 399 161
Total BTU heat loss and sensible gain(does not include 207 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 207 7064 6096
The following is required for forced air heating or air conditioning:
2 Branch ducts-(6 in. round)or(7 in.oval)or(3-1/4 x 10 wall stack)
2 #661 14 x 4 sidewall registers or 2#411 4 x 12 floor diffusers
2#16 8 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers
2#650 10 X 6 in. return air grill,or two 3-1/4 X 14 in.wall returns
3 Heat Cool Area Loss Gain
Floor over ventilated crawl space or garage, R30 ins. 2.6 0.7 169 439 118
Ceiling under unventilated roof,R30 Insulation (10"),Dark roof 2.4 1.7 241 578 410
Skylight, 9 sq ft, double pane,45 degrees 46.6 117 9 419 1053
For more information or to place an order call 413-584-1634 Page: 3
HTM Heat HTM Cool Area or# BTU Loss BTU Gain
Grand total BTU heat loss and 8990 BTU sensible+ 1319 BTU latent heat gain CFM Loss Gain
CFM at recommended maximum trunk velocity of 1000 FPM 342 21123 10309
For more information or to place an order call 413-584-1634 Page: 2
HTM Heat HTM Cool Area or# BTU Loss BTU Gain
The following is required for forced air heating or air conditioning:
2 Branch ducts- (6 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack)
2#661 12 x 4 sidewall registers or 2#411 4 x 10 floor diffusers
2#16 6 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers
2#650 10 X 6 in. return air grill, or two 3-1/4 X 14 in.wall returns
Bedroom#3 Heat Cool Area Loss Gain
Floor over conditioned space, no loss or gain 0 0 144 0 0
Ceiling under ventilated attic, R26 Insulation(8"),Light roof 2.7 1.5 144 389 216
West wall 12 x 7,frame or veneer,R11 Insulation 6.3 2.5 76 479 190
1 Window Double Glass 27 x 44 in.,No Shade In&Out 40.6 72 8 335 594
North wall 12 x 7,frame or veneer, R11 Insulation 6.3 2.5 84 529 210
Infiltration, Loss 1.2 ac/hr, gain 0.5 ac/hr 192.5 22 8 1540 176
Latent heat infiltration allowance for wall/ceiling openings 0 25.9 8 0 207
Total BTU heat loss and sensible gain(does not include 207 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 48 3436 1386
The following is required for forced air heating or air conditioning:
1 Branch duct-(5 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack)
1 #661 6 x 4 sidewall register or 1 #411 2-1/4 x 10 floor diffuser
1 #16 6 in. round ceiling diffuser or 1 #24 6 x 6 in. square diffuser
1 #650 10 X 6 in. return air grill,or one 3-1/4 X 14 in. wall returns
foyer Heat Cool Area Loss Gain
Floor over conditioned space,no loss or gain 0 0 245 0 0
Ceiling under ventilated attic,R26 Insulation(8"),Dark roof 2.7 1.8 236 637 425
Skylight,9 sq ft,double pane,45 degrees 46.6 0 9 419 0
West wall 10 x 7, frame or veneer,R11 Insulation 6.3 2.5 70 441 175
North wall 6 x 7,frame or veneer,R11 Insulation 6.3 2.5 42 265 105
Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 290.9 34.2 9 2618 308
Latent heat infiltration allowance for wall/ceiling openings 0 40.2 9 0 362
Total BTU heat loss and sensible gain(does not include 362 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 64 4599 1013
The following is required for forced air heating or air conditioning:
1 Branch duct-(5 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack)
1 #661 10 x 4 sidewall register or 1 #411 2-1/4 x 14 floor diffuser
1 #16 6 in. round ceiling diffuser or 1 #24 6 x 6 in. square diffuser
1 #650 10 X 6 in. return air grill, or one 3-1/4 X 14 in. wall returns
Whole building
System Design:
Supply trunk duct is 18 x 8 reduced 2 inces every 30 feet
Return duct is 18 x 8 reduced 2 inces every 30 feet
If CFM of selected air handler is greater than 800, increase duct size
Heat Loss/Gain Calculation by Schneider Plg. & Htg. Inc.
For more information or to place an order call 413-584-1634 Page: 1
File Name: 88WASH2 -Residential Calculation Winter: 70 degrees difference
Date: 8/18/2013 Summer:20 degrees difference
Reference: 2nd floor HTM Heat HTM Cool Area or# BTU Loss BTU Gain
Level 1
Bathroom#1 Heat Cool Area Loss Gain
Floor over conditioned space,no loss or gain 0 0 120 0 0
Ceiling under ventilated attic, R26 Insulation(8"), Light roof 2.7 1.5 120 324 180
East wall 12 x 8, frame or veneer,R11 Insulation 6.3 2.5 96 605 240
Infiltration(no wall or ceiling openings) 0 0 0 0 0
Allowance for bathroom comfort 0.2 0.0 975 195 0
Total BTU heat loss and sensible gain(does not include 0 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 14 1170 420
The following is required for forced air heating or air conditioning:
1 Branch duct-(5 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack)
1 #661 6 x 4 sidewall register or 1 #411 2-1/4 x 10 floor diffuser
1 #16 6 in. round ceiling diffuser or 1 #24 6 x 6 in. square diffuser
1 #650 10 X 6 in. return air grill,or one 3-1/4 X 14 in. wall returns
Bedroom#1 Heat Cool Area Loss Gain
Floor over conditioned space,no loss or gain 0 0 141 0 0
Ceiling under ventilated attic,R26 Insulation(8"), Dark roof 2.7 1.8 141 381 254
West wall 12 x 7, frame or veneer, R11 Insulation 6.3 2.5 84 529 210
South wall 15 x 7,frame or veneer,R11 Insulation 6.3 2.5 91 573 228
1 Window Double Glass 36 x 54 in.,No Shade In& Out 40.6 38 14 548 513
Infiltration,Loss 1.2 ac/hr,gain 0.5 ac/hr 110 12.6 14 1540 176
Latent heat infiltration allowance for wall/ceiling openings 0 14.8 14 0 207
Total BTU heat loss and sensible gain(does not include 207 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 53 3750 1381
The following is required for forced air heating or air conditioning:
1 Branch duct-(5 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack)
1 #661 10 x 4 sidewall register or 1 #411 2-1/4 x 14 floor diffuser
1 #16 6 in. round ceiling diffuser or 1 #24 6 x 6 in. square diffuser
1 #650 10 X 6 in.return air grill,or one 3-1/4 X 14 in. wall returns
Bedroom#2 Heat Cool Area Loss Gain
Floor over conditioned space,no loss or gain 0 0 352 0 0
Ceiling under ventilated attic, R26 Insulation(8"), Light roof 2.7 1.5 343 926 514
Skylight,9 sq ft,double pane,45 degrees 46.6 128 9 419 1152
South wall 16 x 7, frame or veneer, R11 Insulation 6.3 2.5 112 706 280
East wall 22 x 7,frame or veneer, R11 Insulation 6.3 2.5 125 788 312
1 Window Double Glass 45 x 92 in.,No Shade In &Out 40.6 72 29 1167 2070
Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 99.3 12.2 38 3773 462
Latent heat infiltration allowance for wall/ceiling openings 0 14.3 38 0 543
Total BTU heat loss and sensible gain(does not include 543 latent gain) CFM Loss Gain
CFM at recommended max velocity of 600 FPM 163 8168 4790
T'
IN.
>.„ . n �,
V
Jx `;4r
/71
sr-
r-`Y Imo.:_ 5
i
( 9I). 19l - A ff � 1
,
f1`Jhi Y ,,-(
(_ici) i r
IMMIK
o i ''. h fI
i _. .1, .
8
1
,1 t, Jv
1.
-.....7-,-.......4.4,,..------- ` c \
�t %..._ ` --L .
r+ I i
f
it
\R j
iL
A►
--- }
_ _
,,- 5.,'-' ' -<,-. •
/6-
, f/ .T.
1 ; -C •f -;.. 6 f I
i ...
,
-.1
Si:
1)....1
...... , :.! i
f,
..„‘. .. I
)11.
/-0
v
40
.."?
-- .
i
. es
i t
ir-
..v
....0
,:k Z Ilir 1
Millellimb:. • 6 . i
. 1
Si
1
t ,
,
1 'Z
.v.•
1..)
• i ,
1
...!
_ 411111#1il"'
'- 4
I 1 L•
.......,.. ...
"4.
LI / 's '.0 1 •
C... ...:111 ()II
I
i
)
f
I
--
-;-.-- A--•
' (';,.,
■,--z)• *S.1 I
,...-e,
— ...
..
, P\ , ,r fi
• ••; - ....„ t__
.
'' NI
- 1
1 . ..
---..<. ....., i/ •
AG-s::-.:"-(31---- .. ,c,...) t)., ,
':**-- %
cc.I
l ll. .
I ?C.' ;I 1,....) ....,...4 ......_
...z
; 4,- ,......„. r;''. '\),..‘ -- -..1
..........._
..„..., -
".... ..
"C•c°:. .
' .
,V) -"'S.-\ 5...1 ,
.>JZ N... • j
.... '-..
..'",...C.:
... '-, 0..-Z7-__
,
ClY....... .,.. ..
. _
- 11
."■••;\ -0 --1"
-,.
t..... ,.,
1-• .5--;
„..1„, %
1.- `.''' .-; • ,
'-: -:--. -
..,;_
-,„
„.
'-•.; •-.•
..,
-C...
. .,
. .
4NN;
...)
(.
- 'N'...
"'' SO
n.,
c,
,-•
$
V ,
-s•
.......
1% • i a i tp,t .7,4.7_ alb
. ..
-- .,z- .....t„ cl)
...,,,, ..... —.ft.
6 -
11
--,\ .....:
- €
' ' 7 ' `,......._
Gfr - 1
,f
t.,../
1
•1
- 9
1
V J 1
___ -I _ .:.1.i- ' ■ 1 ,...-- .
4.'"•
9
i .
. p ---.•
te.,...
... 44_
1
1 .
. ,...._
r --- - -
1
1
...
_....,HJ. '
1
.---il
.....
-......
--,- .....
1 I
T-t-- .,4 ...1
f
i .
i,
1
.
i ,,... .;
, (
•!, NZ"H— ) ' 1 LT'
('' C\• _. r
II, i •-'; .
• j , ,,
.. k •
j 1
11 .
i I
i • i \--‘P .
i 1
. ,•. Pa x
'..• i ' 1
-E. t
6 .„5.....,
,....A.," 1
I .
i i •
1
. .
I -V,-,-,-- ?".
i ..
.,-'
....„0„:„....___ .
...
...■.
k....cs,
, .
. .
•
INSURANCE COVERAGE:
I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 YesI No❑
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy jf Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER:I am aware that the licensee rIrw not hallos the insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application waiioscthis requirement.
Check One Only
Owner ❑ Agent ❑
Signature of Owner or Owner's Agent
By checking this box ,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation: YES NO
Prngreec inepeCtinne
Pate Comments
Final invert-inn,
Date Comments
Type of License:
By ❑ Master
Title 0 Master-Restricted
City/Town ❑Joumeyperson Signature of Licensee
Permit# ❑Joumeyperson-Restricted
License Number:
Fee$ 64)
Check at swish-4 s
I �
Inspector Signature of Permit Approval
D rEC1W Fhr;771:,, Commonwealth of Massachusetts
OCT - 3 2013 !);'' City Of Northam p ton
_.i
Electric. Plumbing&Gas InsptIctlon$
ortht-mpton, MA',C6 Sheet Metal Permit �
Permit# � ��,[,�/ ��a D
Estimated Job Cost: $ 2 5/ C C o, e > Permit Fee: $ 5, Oo 6d g
Plans Submitted: YES NO X Plans Reviewed: YES NO
Business License# j y 0 L, 0 Applicant License# f3 I `+q I
Business Information: Property Owner/Job Location Information:
Name: Sc 4 efee'2 �L, /5'1 -1Xt Name: 111 `L ' -t C�_0
Street: 13/ A44(;-, ✓? 0 3)- 3 Street: (Mc 0 , )(X c)h i V 1C - V 1 ve,
City/Town: 2 d r s 1 r,,i t r 41y m# City/Town: f tic.}ii-4- `1 i/11 p 40V1
Telephone: II/,3 6,(1. O d O 2 Telephone: -{V?)— 5 LI i -oay1 j
Photo I.D.required/Copy of Photo I.D. attached: YES X NO
Staff Initial
J-1 /M-1-unrestricted license
J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less
Residential: 1-2 family )' Multi-family Condo/Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other
Square Footage: under 10,000 sq. ft. /1 over 10,000 sq. ft. Number of Stories:
Sheet metal work to be completed: New Work: Renovation: ,
HVAC_X Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
'5/q II / %4 e 1C1 4 F f
� �x 'ae r f 4e if k.az/l
rl -
oZ 4i/� b' frietl t As Cc./71; #r '/l0Nrc Co/4 rorL
Camilojfi;1 &eaI 4, A C...
Fees with Building Permit:$25.00 Residential,$50.00 Commercial.Fees for jobs without a Building Permit$6.00 per$1000
Minimum fees for jobs without Building Permit$50.00 Residential,$100.00 Commercial
File#SM-2014-0018
APPLICANT/CONTACT PERSON SCHNEIDER PLG&HTG
ADDRESS/PHONE P 0 BOX 323 (413) 584-1634
PROPERTY LOCATION 88 WASHINGTON AVE
MAP 31A PARCEL 279 001 ZONE URAQ100)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out 6 V 0025P'
Fee Paid
Typeof Construction: DUCKTWORK FOR GAS FURNACE
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/Statement or License 5400
3 sets of Plans/Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INF9'RMATION PRESENTED:
It/Approved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER: §
Intermediate Project: Site Plan AND/OR Special Permit with Site Plan
Major Project: Site Plan AND/OR Special Permit with Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
'ermit f om Elm Street Commission Permit DPW Storm Water Management
Signature of Building Official Date
Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of
Planning&Development for more information.
88 WASHINGTON AVE SM-2014-0018
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS#: [5886 2°� HA 'H
Map: 131A �)'� \i
1B1ock �z9 � 6 SHEETMETAL, PERMIT
Lot. oo l
Permit SHEETMETAL TfR�ENTENPRN
1Category: SHEETMETAL
Permit# �SM-2014-0018
Project# JS-2014-000370 PERMISSION IS HEREBY GRANTED TO:
t- Cost:_ �--
- —
Est.st. Contractor: License:or:rac
on
Cost: $25,000.00 Expires:
SCHNEIDER PLG&HTG Sheetmetal-5400
Fee Charged:$25.00 03/28/2014
Balance Due:$.00 Owner: FRIEDMAN THOMAS H&
'#of Fixtures: Applicant: SCHNEIDER PLG&HTG
----------------Cost
DigSafe#
AT: 88 WASHINGTON AVE
UseGroup
ConstClass
ISSUED ON: 10-Dec-2013 AMENDED ON: EXPIRES ON:
TO PERFORM THE FOLLOWING WORK:
DUCKTWORK FOR GAS FURNACE
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2014-001562 04-Oct-I3 62825 $25.00
Inspection Type: Inspector: Date Inspected: Date Signed Off: Status:
ROUGH Charles Miller 07-Oct-13 FULL COMPLY
212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck @northamptonma.gov
GeoTMS®2013 Des Lauriers Municipal Solutions,Inc.