Loading...
31A-279 (2) For more information or to place an order call 413-584-1634 Page: 2 HTM Heat HTM Cool Area or# BTU Loss BTU Gain North West wall 15 x 8,frame or veneer, R11 Insulation 6.3 2.6 111 699 289 1 Window Double Glass 36 x 36 in.,No Shade In&Out 40.6 53 9 365 477 North East wall 10 x 8, frame or veneer, R11 Insulation 6.3 2.6 68 428 177 1 Window Double Glass 36 x 48 in.,No Shade In&Out 40.6 53 12 487 636 South East wall 15 x 8,frame or veneer,R11 Insulation 6.3 2.6 105 662 273 1 Window Double Glass 36 x 60 in.,No Shade In&Out 40.6 65 15 609 975 Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 139 20.6 36 5005 743 Latent heat infiltration allowance for wall/ceiling openings 0 19.4 36 0 698 Allowance for appliances and motors 0.0 2.0 600 0 1200 Total BTU heat loss and sensible gain(does not include 698 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 186 13302 3570 The following is required for forced air heating or air conditioning: 2 Branch ducts-(6 in.round)or(7 in. oval)or(3-1/4 x 10 wall stack) 2#661 14 x 4 sidewall registers or 2#411 4 x 12 floor diffusers 2#16 8 in. round ceiling diffuser or 2#24 6 x 6 in. square diffusers 2#650 10 X 6 in. return air grill,or two 3-1/4 X 14 in.wall returns Living Room Heat Cool Area Loss Gain Floor over enclosed crawl space or unheated basement,No ins. 10.9 0 300 3270 0 Ceiling under conditioned room 0 0 300 0 0 North West wall 20 x 8,frame or veneer, R11 Insulation 6.3 2.6 121 762 315 1 Window Double Glass 36 x 60 in.,No Shade In&Out 40.6 53 15 609 795 1 Window Double Glass 6 x 84 in.,No Shade In&Out 40.6 53 4 142 186 1 Door Solid Wood,No Storm Door 36 x 80 in. 32.2 13.2 20 644 264 South West wall 15 x 8,frame or veneer,R11 Insulation 6.3 2.6 108 680 281 1 Window Double Glass 30 x 60 in.,No Shade In&Out 40.6 65 12 508 812 South East wall 9 x 8, frame or veneer, R11 Insulation 6.3 2.6 60 378 156 1 Window Double Glass 30 x 60 in.,No Shade In&Out 40.6 65 12 508 812 Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 58.7 8.7 63 3696 550 Latent heat infiltration allowance for wall/ceiling openings 0 8.2 63 0 517 Total BTU heat loss and sensible gain(does not include 517 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 165 11757 4171 The following is required for forced air heating or air conditioning: 2 Branch ducts-(6 in.round)or(6 in. oval)or(3-1/4 x 8 wall stack) 2#661 12 x 4 sidewall registers or 2#411 4 x 10 floor diffusers 2#16 6 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers 2#650 10 X 6 in.return air grill,or two 3-1/4 X 14 in.wall returns Whole building System Design: Supply trunk duct is 18 x 8 reduced 2 inces every 30 feet Return duct is 18 x 8 reduced 2 inces every 30 feet If CFM of selected air handler is greater than 800, increase duct size - Heat Loss/Gain Calculation by Schneider Plg. & Htg. Inc. For more information or to place an order call 413-584-1634 Page: 1 File Name: 88WASHI -Residential Calculation Winter: 70 degrees difference Date: 7/27/2013 Summer:25 degrees difference Reference: ccb 88 washington HTM Heat HTM Cool Area or# BTU Loss BTU Gain Level 1 Den Heat Cool Area Loss Gain Floor over enclosed crawl space or unheated basement,No ins. 10.9 0 176 1918 0 Ceiling under conditioned room 0 0 176 0 0 South West wall 16 x 8,frame or veneer, Rl 1 Insulation 6.3 2.6 116 731 302 1 Window Single Glass 30 x 60 in.,No Shade In&Out 77 82 12 962 1025 South East wall 11 x 8,frame or veneer,R11 Insulation 6.3 2.6 46 290 120 1 Window Double Glass 72 x 84 in.,No Shade In& Out 40.6 65 42 1705 2730 North East wall 7 x 8,frame or veneer,R11 Insulation 6.3 2.6 56 353 146 Infiltration, Loss 1.2 ac/hr, gain 0.5 ac/hr 39.9 6.1 54 2156 330 Latent heat infiltration allowance for wall/ceiling openings 0 5.7 54 0 310 Total BTU heat loss and sensible gain (does not include 310 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 158 8521 4653 The following is required for forced air heating or air conditioning: 2 Branch ducts- (6 in. round)or(6 in. oval)or(3-1/4 x 8 wall stack) 2 #661 12 x 4 sidewall registers or 2#411 4 x 10 floor diffusers 2#16 6 in. round ceiling diffuser or 2#24 6 x 6 in. square diffusers 1 #650 10 X 6 in.return air grill, or one 3-1/4 X 14 in. wall returns entry Heat Cool Area Loss Gain Concrete slab on grade,No edge ins. 56.7 0 45 2552 0 Ceiling under conditioned room 0 0 168 0 0 North East wall 15 x 9,frame or veneer, R11 Insulation 6.3 2.6 98 617 255 1 Window Double Glass 48 x 48 in.,No Shade In& Out 40.6 53 16 650 848 l Window Double Glass 6 x 82 in.,No Shade In&Out 40.6 53 3 139 181 1 Door Solid Wood,No Storm Door 32 x 80 in. 32.2 13.2 18 580 238 South East wall 3 x 8, frame or veneer,R11 Insulation 6.3 2.6 24 151 62 South West wall 15 x 8,frame or veneer, R11 Insulation 6.3 2.6 96 605 250 1 Window Double Glass 6 x 84 in.,No Shade In&Out 40.6 65 4 142 228 1 Door Solid Wood,No Storm Door 36 x 80 in. 32.2 13.2 20 644 264 Cold wall 12 x 8 ft,Frame,R11 insulation 4.9 1.8 96 470 173 Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 8.8 1.3 61 539 82 Latent heat infiltration allowance for wall/ceiling openings 0 1.3 61 0 78 Total BTU heat loss and sensible gain(does not include 78 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 104 7443 2581 The following is required for forced air heating or air conditioning: 2 Branch ducts- (5 in. round)or(5 in. oval)or(3-1/4 x 8 wall stack) 2 #661 10 x 4 sidewall registers or 2#411 2-1/4 x 14 floor diffusers 2 #16 6 in. round ceiling diffuser or 2#24 6 x 6 in. square diffusers 1 #650 10 X 6 in. return air grill,or one 3-1/4 X 14 in.wall returns Kitchen Heat Cool Area Loss Gain Floor over enclosed crawl space or unheated basement,No ins. 10.9 0 405 4414 0 Ceiling under conditioned room 0 0 405 0 0 For more information or to place an order call 413-584-1634 Page: 2 HTM Heat HTM Cool Area or# BTU Loss BTU Gain North wall 13 x 5,frame or veneer,R19 Insulation 4.2 1.7 65 273 110 West wall 19 x 10,frame or veneer,R19 Insulation 4.2 1.7 165 693 281 1 Window Double Glass 57 x 48 in.,No Shade In&Out 40.6 72 19 771 1368 1 Window Double Glass 24 x 36 in.,No Shade In&Out 40.6 72 6 244 432 Total BTU heat loss and sensible gain(does not include 129 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 132 4316 3882 The following is required for forced air heating or air conditioning: 2 Branch ducts-(5 in. round)or(5 in. oval)or(3-1/4 x 8 wall stack) 2#661 10 x 4 sidewall registers or 2#411 2-1/4 x 14 floor diffusers 2#16 6 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers 1 #650 10 X 6 in.return air grill,or one 3-1/4 X 14 in. wall returns Whole building System Design: Supply trunk duct is 18 x 8 reduced 2 inces every 30 feet Return duct is 18 x 8 reduced 2 inces every 30 feet If CFM of selected air handler is greater than 800, increase duct size Grand total BTU heat loss and 13498 BTU sensible+388 BTU latent heat gain CFM Loss Gain CFM at recommended maximum trunk velocity of 1000 FPM 459 19633 13886 Heat Loss/Gain Calculation by Schneider Plg. & Htg. Inc. For more information or to place an order call 413-584-1634 Page: 1 File Name: 88WASHI -Residential Calculation Winter: 70 degrees difference Date: 8/18/2013 Summer:20 degrees difference Reference: garage add HTM Heat HIM Cool Area or# BTU Loss BTU Gain Level 1 1 Heat Cool Area Loss Gain Concrete slab on grade, 1 inch edge ins. R5 28.7 0 54 1550 0 Ceiling under unventilated roof,R30 Insulation(10"), Dark roof 2.4 1.7 150 360 255 South wall 17 x 10, frame or veneer,R19 Insulation 4.2 1.7 122 512 207 2 Windows Double Glass 33 x 60 in.,No Shade In&Out 40.6 38 28 1116 1045 1 Door Solid Wood,No Storm Door 36 x 80 in. 32.2 12.7 20 644 254 North wall 13 x 10, frame or veneer, R19 Insulation 4.2 1.7 92 386 156 3 Windows Double Glass 30 x 60 in.,No Shade In&Out 40.6 23 38 1522 862 North wall 22 x 10, frame or veneer,R19 Insulation 4.2 1.7 220 924 374 Cold wall 19 x 10 ft,Frame,RI1 insulation 4.9 1.7 190 931 323 Infiltration,Loss 0.4 ac/hr, gain 0.2 ac/hr 3.6 0.5 86 308 44 Latent heat infiltration allowance for wall/ceiling openings 0 0.6 86 0 52 Total BTU heat loss and sensible gain(does not include 52 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 120 8253 3520 The following is required for forced air heating or air conditioning: 2 Branch ducts-(5 in. round)or(5 in. oval)or(3-1/4 x 8 wall stack) 2#661 10 x 4 sidewall registers or 2#411 2-1/4 x 14 floor diffusers 2#16 6 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers 1 #650 10 X 6 in. return air grill, or one 3-1/4 X 14 in.wall returns Level 2 2 Heat Cool Area Loss Gain Floor over ventilated crawl space or garage, R30 ins. 2.6 0.7 285 741 199 Ceiling under unventilated roof, R30 Insulation(10"), Dark roof 2.4 1.7 295 708 502 Skylight,9 sq ft, double pane,45 degrees 46.6 117 9 419 1053 South wall 19 x 10,frame or veneer,R19 Insulation 4.2 1.7 165 693 281 l Window Double Glass 60 x 60 in.,No Shade In&Out 40.6 38 25 1015 950 East wall 15 x 10,frame or veneer,R19 Insulation 4.2 1.7 114 479 194 1 Window Double Glass 60 x 86 in.,No Shade In&Out 40.6 72 36 1455 2580 North wall 19 x 5,frame or veneer,R19 Insulation 4.2 1.7 95 399 161 Total BTU heat loss and sensible gain(does not include 207 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 207 7064 6096 The following is required for forced air heating or air conditioning: 2 Branch ducts-(6 in. round)or(7 in.oval)or(3-1/4 x 10 wall stack) 2 #661 14 x 4 sidewall registers or 2#411 4 x 12 floor diffusers 2#16 8 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers 2#650 10 X 6 in. return air grill,or two 3-1/4 X 14 in.wall returns 3 Heat Cool Area Loss Gain Floor over ventilated crawl space or garage, R30 ins. 2.6 0.7 169 439 118 Ceiling under unventilated roof,R30 Insulation (10"),Dark roof 2.4 1.7 241 578 410 Skylight, 9 sq ft, double pane,45 degrees 46.6 117 9 419 1053 For more information or to place an order call 413-584-1634 Page: 3 HTM Heat HTM Cool Area or# BTU Loss BTU Gain Grand total BTU heat loss and 8990 BTU sensible+ 1319 BTU latent heat gain CFM Loss Gain CFM at recommended maximum trunk velocity of 1000 FPM 342 21123 10309 For more information or to place an order call 413-584-1634 Page: 2 HTM Heat HTM Cool Area or# BTU Loss BTU Gain The following is required for forced air heating or air conditioning: 2 Branch ducts- (6 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack) 2#661 12 x 4 sidewall registers or 2#411 4 x 10 floor diffusers 2#16 6 in.round ceiling diffuser or 2#24 6 x 6 in. square diffusers 2#650 10 X 6 in. return air grill, or two 3-1/4 X 14 in.wall returns Bedroom#3 Heat Cool Area Loss Gain Floor over conditioned space, no loss or gain 0 0 144 0 0 Ceiling under ventilated attic, R26 Insulation(8"),Light roof 2.7 1.5 144 389 216 West wall 12 x 7,frame or veneer,R11 Insulation 6.3 2.5 76 479 190 1 Window Double Glass 27 x 44 in.,No Shade In&Out 40.6 72 8 335 594 North wall 12 x 7,frame or veneer, R11 Insulation 6.3 2.5 84 529 210 Infiltration, Loss 1.2 ac/hr, gain 0.5 ac/hr 192.5 22 8 1540 176 Latent heat infiltration allowance for wall/ceiling openings 0 25.9 8 0 207 Total BTU heat loss and sensible gain(does not include 207 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 48 3436 1386 The following is required for forced air heating or air conditioning: 1 Branch duct-(5 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack) 1 #661 6 x 4 sidewall register or 1 #411 2-1/4 x 10 floor diffuser 1 #16 6 in. round ceiling diffuser or 1 #24 6 x 6 in. square diffuser 1 #650 10 X 6 in. return air grill,or one 3-1/4 X 14 in. wall returns foyer Heat Cool Area Loss Gain Floor over conditioned space,no loss or gain 0 0 245 0 0 Ceiling under ventilated attic,R26 Insulation(8"),Dark roof 2.7 1.8 236 637 425 Skylight,9 sq ft,double pane,45 degrees 46.6 0 9 419 0 West wall 10 x 7, frame or veneer,R11 Insulation 6.3 2.5 70 441 175 North wall 6 x 7,frame or veneer,R11 Insulation 6.3 2.5 42 265 105 Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 290.9 34.2 9 2618 308 Latent heat infiltration allowance for wall/ceiling openings 0 40.2 9 0 362 Total BTU heat loss and sensible gain(does not include 362 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 64 4599 1013 The following is required for forced air heating or air conditioning: 1 Branch duct-(5 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack) 1 #661 10 x 4 sidewall register or 1 #411 2-1/4 x 14 floor diffuser 1 #16 6 in. round ceiling diffuser or 1 #24 6 x 6 in. square diffuser 1 #650 10 X 6 in. return air grill, or one 3-1/4 X 14 in. wall returns Whole building System Design: Supply trunk duct is 18 x 8 reduced 2 inces every 30 feet Return duct is 18 x 8 reduced 2 inces every 30 feet If CFM of selected air handler is greater than 800, increase duct size Heat Loss/Gain Calculation by Schneider Plg. & Htg. Inc. For more information or to place an order call 413-584-1634 Page: 1 File Name: 88WASH2 -Residential Calculation Winter: 70 degrees difference Date: 8/18/2013 Summer:20 degrees difference Reference: 2nd floor HTM Heat HTM Cool Area or# BTU Loss BTU Gain Level 1 Bathroom#1 Heat Cool Area Loss Gain Floor over conditioned space,no loss or gain 0 0 120 0 0 Ceiling under ventilated attic, R26 Insulation(8"), Light roof 2.7 1.5 120 324 180 East wall 12 x 8, frame or veneer,R11 Insulation 6.3 2.5 96 605 240 Infiltration(no wall or ceiling openings) 0 0 0 0 0 Allowance for bathroom comfort 0.2 0.0 975 195 0 Total BTU heat loss and sensible gain(does not include 0 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 14 1170 420 The following is required for forced air heating or air conditioning: 1 Branch duct-(5 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack) 1 #661 6 x 4 sidewall register or 1 #411 2-1/4 x 10 floor diffuser 1 #16 6 in. round ceiling diffuser or 1 #24 6 x 6 in. square diffuser 1 #650 10 X 6 in. return air grill,or one 3-1/4 X 14 in. wall returns Bedroom#1 Heat Cool Area Loss Gain Floor over conditioned space,no loss or gain 0 0 141 0 0 Ceiling under ventilated attic,R26 Insulation(8"), Dark roof 2.7 1.8 141 381 254 West wall 12 x 7, frame or veneer, R11 Insulation 6.3 2.5 84 529 210 South wall 15 x 7,frame or veneer,R11 Insulation 6.3 2.5 91 573 228 1 Window Double Glass 36 x 54 in.,No Shade In& Out 40.6 38 14 548 513 Infiltration,Loss 1.2 ac/hr,gain 0.5 ac/hr 110 12.6 14 1540 176 Latent heat infiltration allowance for wall/ceiling openings 0 14.8 14 0 207 Total BTU heat loss and sensible gain(does not include 207 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 53 3750 1381 The following is required for forced air heating or air conditioning: 1 Branch duct-(5 in.round)or(6 in.oval)or(3-1/4 x 8 wall stack) 1 #661 10 x 4 sidewall register or 1 #411 2-1/4 x 14 floor diffuser 1 #16 6 in. round ceiling diffuser or 1 #24 6 x 6 in. square diffuser 1 #650 10 X 6 in.return air grill,or one 3-1/4 X 14 in. wall returns Bedroom#2 Heat Cool Area Loss Gain Floor over conditioned space,no loss or gain 0 0 352 0 0 Ceiling under ventilated attic, R26 Insulation(8"), Light roof 2.7 1.5 343 926 514 Skylight,9 sq ft,double pane,45 degrees 46.6 128 9 419 1152 South wall 16 x 7, frame or veneer, R11 Insulation 6.3 2.5 112 706 280 East wall 22 x 7,frame or veneer, R11 Insulation 6.3 2.5 125 788 312 1 Window Double Glass 45 x 92 in.,No Shade In &Out 40.6 72 29 1167 2070 Infiltration,Loss 1.2 ac/hr, gain 0.5 ac/hr 99.3 12.2 38 3773 462 Latent heat infiltration allowance for wall/ceiling openings 0 14.3 38 0 543 Total BTU heat loss and sensible gain(does not include 543 latent gain) CFM Loss Gain CFM at recommended max velocity of 600 FPM 163 8168 4790 T' IN. >.„ . n �, V Jx `;4r /71 sr- r-`Y Imo.:_ 5 i ( 9I). 19l - A ff � 1 , f1`Jhi Y ,,-( (_ici) i r IMMIK o i ''. h fI i _. .1, . 8 1 ,1 t, Jv 1. -.....7-,-.......4.4,,..------- ` c \ �t %..._ ` --L . r+ I i f it \R j iL A► --- } _ _ ,,- 5.,'-' ' -<,-. • /6- , f/ .T. 1 ; -C •f -;.. 6 f I i ... , -.1 Si: 1)....1 ...... , :.! i f, ..„‘. .. I )11. /-0 v 40 .."? -- . i . es i t ir- ..v ....0 ,:k Z Ilir 1 Millellimb:. • 6 . i . 1 Si 1 t , , 1 'Z .v.• 1..) • i , 1 ...! _ 411111#1il"' '- 4 I 1 L• .......,.. ... "4. LI / 's '.0 1 • C... ...:111 ()II I i ) f I -- -;-.-- A--• ' (';,., ■,--z)• *S.1 I ,...-e, — ... .. , P\ , ,r fi • ••; - ....„ t__ . '' NI - 1 1 . .. ---..<. ....., i/ • AG-s::-.:"-(31---- .. ,c,...) t)., , ':**-- % cc.I l ll. . I ?C.' ;I 1,....) ....,...4 ......_ ...z ; 4,- ,......„. r;''. '\),..‘ -- -..1 ..........._ ..„..., - ".... .. "C•c°:. . ' . ,V) -"'S.-\ 5...1 , .>JZ N... • j .... '-.. ..'",...C.: ... '-, 0..-Z7-__ , ClY....... .,.. .. . _ - 11 ."■••;\ -0 --1" -,. t..... ,., 1-• .5--; „..1„, % 1.- `.''' .-; • , '-: -:--. - ..,;_ -,„ „. '-•.; •-.• .., -C... . ., . . 4NN; ...) (. - 'N'... "'' SO n., c, ,-• $ V , -s• ....... 1% • i a i tp,t .7,4.7_ alb . .. -- .,z- .....t„ cl) ...,,,, ..... —.ft. 6 - 11 --,\ .....: - € ' ' 7 ' `,......._ Gfr - 1 ,f t.,../ 1 •1 - 9 1 V J 1 ___ -I _ .:.1.i- ' ■ 1 ,...-- . 4.'"• 9 i . . p ---.• te.,... ... 44_ 1 1 . . ,...._ r --- - - 1 1 ... _....,HJ. ' 1 .---il ..... -...... --,- ..... 1 I T-t-- .,4 ...1 f i . i, 1 . i ,,... .; , ( •!, NZ"H— ) ' 1 LT' ('' C\• _. r II, i •-'; . • j , ,, .. k • j 1 11 . i I i • i \--‘P . i 1 . ,•. Pa x '..• i ' 1 -E. t 6 .„5....., ,....A.," 1 I . i i • 1 . . I -V,-,-,-- ?". i .. .,-' ....„0„:„....___ . ... ...■. k....cs, , . . . • INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch.112 YesI No❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy jf Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER:I am aware that the licensee rIrw not hallos the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waiioscthis requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box ,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Prngreec inepeCtinne Pate Comments Final invert-inn, Date Comments Type of License: By ❑ Master Title 0 Master-Restricted City/Town ❑Joumeyperson Signature of Licensee Permit# ❑Joumeyperson-Restricted License Number: Fee$ 64) Check at swish-4 s I � Inspector Signature of Permit Approval D rEC1W Fhr;771:,, Commonwealth of Massachusetts OCT - 3 2013 !);'' City Of Northam p ton _.i Electric. Plumbing&Gas InsptIctlon$ ortht-mpton, MA',C6 Sheet Metal Permit � Permit# � ��,[,�/ ��a D Estimated Job Cost: $ 2 5/ C C o, e > Permit Fee: $ 5, Oo 6d g Plans Submitted: YES NO X Plans Reviewed: YES NO Business License# j y 0 L, 0 Applicant License# f3 I `+q I Business Information: Property Owner/Job Location Information: Name: Sc 4 efee'2 �L, /5'1 -1Xt Name: 111 `L ' -t C�_0 Street: 13/ A44(;-, ✓? 0 3)- 3 Street: (Mc 0 , )(X c)h i V 1C - V 1 ve, City/Town: 2 d r s 1 r,,i t r 41y m# City/Town: f tic.}ii-4- `1 i/11 p 40V1 Telephone: II/,3 6,(1. O d O 2 Telephone: -{V?)— 5 LI i -oay1 j Photo I.D.required/Copy of Photo I.D. attached: YES X NO Staff Initial J-1 /M-1-unrestricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family )' Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. /1 over 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work: Renovation: , HVAC_X Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: '5/q II / %4 e 1C1 4 F f � �x 'ae r f 4e if k.az/l rl - oZ 4i/� b' frietl t As Cc./71; #r '/l0Nrc Co/4 rorL Camilojfi;1 &eaI 4, A C... Fees with Building Permit:$25.00 Residential,$50.00 Commercial.Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential,$100.00 Commercial File#SM-2014-0018 APPLICANT/CONTACT PERSON SCHNEIDER PLG&HTG ADDRESS/PHONE P 0 BOX 323 (413) 584-1634 PROPERTY LOCATION 88 WASHINGTON AVE MAP 31A PARCEL 279 001 ZONE URAQ100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out 6 V 0025P' Fee Paid Typeof Construction: DUCKTWORK FOR GAS FURNACE New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 5400 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF9'RMATION PRESENTED: It/Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER: § Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee 'ermit f om Elm Street Commission Permit DPW Storm Water Management Signature of Building Official Date Note:Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact the Office of Planning&Development for more information. 88 WASHINGTON AVE SM-2014-0018 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: [5886 2°� HA 'H Map: 131A �)'� \i 1B1ock �z9 � 6 SHEETMETAL, PERMIT Lot. oo l Permit SHEETMETAL TfR�ENTENPRN 1Category: SHEETMETAL Permit# �SM-2014-0018 Project# JS-2014-000370 PERMISSION IS HEREBY GRANTED TO: t- Cost:_ �-- - — Est.st. Contractor: License:or:rac on Cost: $25,000.00 Expires: SCHNEIDER PLG&HTG Sheetmetal-5400 Fee Charged:$25.00 03/28/2014 Balance Due:$.00 Owner: FRIEDMAN THOMAS H& '#of Fixtures: Applicant: SCHNEIDER PLG&HTG ----------------Cost DigSafe# AT: 88 WASHINGTON AVE UseGroup ConstClass ISSUED ON: 10-Dec-2013 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: DUCKTWORK FOR GAS FURNACE THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2014-001562 04-Oct-I3 62825 $25.00 Inspection Type: Inspector: Date Inspected: Date Signed Off: Status: ROUGH Charles Miller 07-Oct-13 FULL COMPLY 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck @northamptonma.gov GeoTMS®2013 Des Lauriers Municipal Solutions,Inc.