17C-211 Section 706 Accessibility
The building entrance and most public spaces are handicap accessible.
The scope of this project does not modify any of those existing
accessibility components. The new door installed under this project shall
meet current accessibility requirements
Section 707 Structural
The scope of this project work area does not affect any existing structural
systems
Section 708 Electrical
The scope of this project provides limited modifications to existing
electrical distribution devices and wiring. All new devices and wiring
within newly installed partitions and ceilings shall comply with all
applicable requirements of NFPA 70
Section 709 Mechanical
The scope for this project work area does not affect the building envelope
regarding energy conservation. No changes are proposed to the existing
mechanical HVAC system serving the project area, other than slight
modifications for distribution layout. The existing mechanical ventilation
system being modified shall be adjusted to provide no less than 5 cfm per
person of outdoor air and not less than 15 cfm of ventilation air per person
Section 710 Plumbing
Not applicable as the occupant load will be unchanged within the project
work area
Section 711 Energy Conservation
The scope of this project does not modify any component of the building
envelope
END OF CHAPTER 4 REVIEW REPORT
64 Gothic Street, Suite 1, Northampton, MA 01060 1 413. 585.1512 I tax 413.586.7945 I wv v.haiarchitecture.com
Section 705 Means of Egress
Paragraph 705.1 Scope
The existing egress requirements within the project work area are
compliant with 780 CMR 8 Edition and Life Safety Code 101. One new
traffic control door located in the egress corridor will meet current
requirements of 780 CMR 8 Edition and Life Safety Code 101
Paragraph 705.3 Number of Exits
Multiple exits serve the project area in compliance with 780 CMR 8th
Edition
Paragraph 705.4 Egress Doorways
The new door provided under this project is a traffic control door which
does not fall within any exit enclosure or egress access corridor enclosure
partitions and therefore does not require a door closer. This door does not
create a dead end corridor
Paragraph 705.5 Openings in Corridor Walls
There are no rated walls in the project area
Paragraph 705.6 Dead end Corridors
There are no dead end corridors existing or new in the project area
Paragraph 705.7 Means of Egress Lighting,
Artificial lighting in conformance with 780 CMR 8 Edition exists and shall
be maintained in the means of egress in the project area
Paragraph 705.8 Exit Signs
A new exit sign will be added where the new traffic control door is placed
within the means of egress access corridor
64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com
4. ALTERATIONS LEVEL 2
Section 701 General
This project work area will comply with all requirements for Alteration
Level 2 as specified in Chapter 7. No portion of the proposed project work
area alters the existing conditions such that the building will become less
safe than its existing condition. Requirements regarding flood hazard
areas are not applicable to this project
Section 702 Special Use and Occupancy
Not applicable
Section 703 Building Elements and Materials
Paragraph 703.2 Vertical Openings
No new or existing vertical floor openings are within the project work area
Paragraph 703.3 Smoke Barriers
No existing smoke barriers are within the project work area
Paragraph 703.4 Interior Finish
All new interior finishes, including wall, ceiling, floor, and trim materials to
be installed under this project work area will comply with 780 CMR 8th
Edition. The work area is less than 50% of the total floor area, hence
finishes in exits and corridors are not required to be modified by this
project
Paragraph 703.5 Guards
No new or existing guards are part of the project work area
Section 704 Fire Protection
An approved automatic fire protection system exists throughout the
building and will not be modified as part of this project
A fire alarm system, compliant with 780 CMR 8 Edition, 527 CMR, and
the International Fire Code, exists within the project work area and will not
be modified as part of this project
64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.15 "12 I fax 413.586.7945 I www.haiarchitecture.com
Section 606 Structural
See Section 707 below
Section 607 Energy Conservation
See Section 711 below
64 Gothic Street, Suite 1, Northampton, MA 01060 I 4 13. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com
3. ALTERATIONS LEVEL 1
Section 601 General
This project work area will comply with all requirements for Alteration
Level 1 as specified in Chapter 6. No portion of the proposed project work
area alters the existing conditions such that the building will become less
safe than its existing condition. Requirements regarding flood hazard
areas are not applicable to this project
Section 602 Building Elements and Materials
Paragraph 602.1 Interior Finishes
All newly installed interior wall and ceiling finishes shall comply with 780
CMR 8 Edition
Paragraph 602.2 Interior Floor Finishes
All newly installed interior floor finishes shall comply with 780 CMR 8th
Edition
Paragraph 602.3 Interior Trim
All newly installed interior trim materials shall comply with 780 CMR 8th
Edition
Paragraph 602.4 Materials and Methods
All new work shall comply with materials and methods requirements of
780 CMR 8 Edition and other applicable codes cited in the International
Existing Building Code
Section 603 Fire Protection
See Section 704 below
Section 604 Means of Egress
See Section 705 below
Section 605 Accessibility
See Section 706 below
64Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I tax 413.586.7945 I www.haiarchitecture.com
2. CLASSIFICATION OF WORK
The proposed project work area is classified as Alteration - Level 2 per
EIBC Section 402 and therefore complies with the provisions of Chapter 6
and Chapter 7 as reviewed in the following sections.
The scope of work is limited to:
• demolition of one existing office
• installation of one new traffic control door
• installation of office systems furniture cubicles
• modification of existing suspended acoustical ceiling systems
• upgrade of wall and floor finishes
• modification of existing and installation of new general illumination
Tight fixtures
• installation of new exit sign to match building standard
• rebalancing of existing HVAC system
This project's construction costs will not exceed 30% the assessed value
of the entire building
The project completion is expected in summer 2012
64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com
1. GENERAL INFORMATION
A. PROPERTY NAME:
Florence Savings Bank
B. ADDRESS:
85 Main Street, Florence, Massachusetts 01062
C. BUILDING USE:
The building was originally constructed as, and continues to be used for,
B- Business occupancy.
D. BUILDING USE GROUP:
B- Business as defined by the Massachusetts Building Code. This project
will not change the Building Use Group.
E. CONSTRUCTION CLASSIFICATION:
Newer Portions
Type 2A (protected)
Foundation: concrete slab on grade; cast in place concrete walls
Exterior Walls: face brick/ concrete masonry unit
Int. Load Bearing: concrete columns / steel floor joists/ concrete floor
slabs
Roof: concrete roof slab / flat membrane roofing
Original Building
Type 3B (unprotected)
Foundation: concrete slab on grade; cast in place concrete walls
Exterior Walls: face brick/ concrete masonry unit
Int. Load Bearing: wood frame partitions / wood floor joists/ wood floor
sheathing
Roof: wood framing / pitched shingle roofing
F. HAZARD INDEX:
Existing and proposed Hazard Index is 4 as defined by the Massachusetts
Building Code.
64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I tax 41.3.586.7945 I www.haiarchitecture.ccm
780 CMR 8 Edition
International Existing Building Code 2009
Renovations for
Mortgage Origination Department
Florence Savings Bank
Purpose
This Report is in conformance with Massachusetts Building Code 780
CMR 8 Edition and the International Existing Building Code 2009
Chapter 4 regarding alterations (Mortgage Origination Department) to an
existing building, Florence Savings Bank, 85 Main Street, Florence,
Massachusetts.
Limitations of review
The extent of this review is limited to visual inspection of existing facilities
and /or as -built documentation only. No destructive testing was performed
as part of this analysis.
64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com
Existing Conditions Evaluation Report
780 CMR 8 Edition
International Existing Building Code 2009
Renovations for
Mortgage Origination Department
Florence Savings Bank
85 Main Street
Florence, Massachusetts 01062
June 26, 2012
*' 5t EK AN
��� K AT 4 ' � :
' o.
1 TON
AtHUSETT
Al r: pared b
p P Y
Richard E. Katsanos, AIA, Principal
H I AI Architecture
64 Gothic Street, Suite 1, Northampton, NIA 01060 I 413. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com
CITY OF NORTHAMPTON, MASSACHUSETTS
CONSTRUCTION CONTROL AFFIDAVIT
PROJECT NUMBER: 12 -015 DATE: June 26, 2012
PROJECT TITLE: Renovations for Mortgage Origination Department
PROJECT LOCATION: 85 Main Street, Florence, MA 01062
NAME OF BUILDING:
SCOPE OF PROJECT: Interior Renovations
In accordance with the Massachusetts State Building Code, 780 CMR 8 Edition, Chapter 1,
Section 107.6 Construction Control, I, Richard E. Katsanos, Massachusetts Registration No.
8355, being a registered professional Architect, hereby certify that I have prepared or directly
supervised the preparation of all design plans, computations, and specifications concerning
architectural scope for the above named project and that, to the best of my knowledge, such
plans, computations and specifications meet applicable provisions of the Massachusetts State
Building Code, 8 Edition, all acceptable engineering practices and all applicable laws for the
proposed project.
I ENTIRE PROJECT I ARCHITECTURAL STRUCTURAL
FIRE PROTECTION ELECTRICAL MECHANICAL
OTHER (specify)
I further certify that I shall perform the necessary professional services and be present on the
construction site on a regular basis to determine that the work is proceeding in accordance with
the documents approved for the building permit and shall be responsible for the following as
specified in Section 107.6.2.2 Construction:
1. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals
by the contractor in accordance with the requirements of the construction documents.
2. Perform the duties for registered design professionals in Chapter 17.
3. Be present at intervals appropriate to the stage of construction to become generally familiar with the
progress and quality of the work and to determine if the work is being performed in a manner consistent
with the construction documents and this code.
Pursuant to Section 107.6, I shall submit periodically, a progress report together with pertinent
comments to the Building Inspector. Upon completion of the work, I shall submit a final report
and an affidavit of completion as to the satisfactory completion and readiness of the project for
.g4lu.,eancy.
RED A a ,,,,
, , c , j Y.AT S4 :', Subset' .14 and sworn to before me
<<, 2 1 ,; this .._#: g ay of___, 20
IQ No. 8355 N t I1- i ,
WESTHhMPTON , �� � / / /,
MASSAC� �[ /���� 43,-11-z. 1 .
\ �''
v .. -- Notary Public . ,I,,,..,i,,,
�� r I , atsanos, AIA My Commission expires on . , ., ' . e:..04/
, tt Q (.> • 26 20q . A:
'c �. • :: ..'-a 11: .ci l) cs,cn 1
T. 2 'kg SSAC , \f • . � ��∎ •
a
9 ��,- 10 csaschnsctta ' =`�' -- �` "__ •
V
DEPARTMENT OF BUILDING INSPECTIONS
• 212 Main Street • Municipal Building
Northampton, Mass. 01060 or "
WORIOR' S COMPENSATION INSURANCE A l
I, Pioneer Contractors -
(licenser/permi tree)
with a principal place of business/residence at:
•
P.O. Box 1145 Northampton, M2. 01-061 (phone #) 586 5491 -
(e =t/city /state /cep)
do hereby certify, under the pains and penalties of perjury, that:
( 1 am an employer providing the following worker's compensation coverage for Ivy
employees working on this job:
•
Wcc 50059570120012
Asccrriater1 Employers Insuranr'e Co - - -- - 6 / 1 0/Ia
(Insurance: Compan (Policy Number) (Expiration Date)
( ) 1 am a sole proprietor, general contractor or homeowner (circle one) and have hired
the contractors listed below who have the following worker's compensation policies:
(Name of Contractor) (Insurance Company/Policy Number) (Exp rntion Date)
(Name of Contractor) (Insurance Company/Poliey Number) (Expiration Date)
•
(Naive of Conn - actor) (bnsurance Company/Policy Number) (Entrain Date)
(Name of Contractor (Insurance Company/Policy Number) (Expiration Date)
(anach additiocal shxet if nn , • ry to meludc information pertaining to all ooctracton)
( ) 1 am a sole proprietor and have no one working for me.
( ) lam a home owner performing all the work myself
NOTE: please be aware that while homeowners who employ pawns to do orcalutconace, construction or repair work on a dwelling of
not meat than threo units in which the bocnnowocr maid= or oat the grounds appurtenant theccto arc not go rally ooatidc+cd to be
cenploytt-a tmdcr the worker`s ceccPcctsttlica Act (GL151 1(5)), application by a. homeowner fora ri==ms= or permit may evidence the
legal' atatua of an employer under tho • Worircls Compo iiioa Act_
I underataad that a copy of this AYrunm4 may bo fotward.ed to tho Department ofIndumial Accidence Of600 of Inzunnco for the
covent,3c unification and that feilurc to foot= covcrago under section 25A of MQL 152 c:tn Iesd to the imposition of criminal pcasltics
cocesisoatg of a fine of up to S1,300.00 and/or impri5occmccEt of up to one year and civil penalties in tbo form of a Stop Work Ord= and a -
fine of 5100.00 a day against me.
-
/ / t r Fa dcputm i Luc cnh'
ijiilzoa - Lot # Permit Number .t. A. Pr maps
rS . Si.. true ofLiccnscefPermi • - _
•
Versionl.7 Commercial Building Permit May 15, 2000
SECTION 10- STRUCTURAL PEER REVIEW (780 CMR 110.11)
Independent Structural Engineering Structural Peer Review Required Yes 0 No
SECTION 11 - OWNER AUTHORIZATION - TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I, Mate' - 60w, Cu^- er, /,. fa&-s as Owner of the subject property
hereby authorize 2l0 4"Anr- (4W U �ti to
act on my behalf, in all matters relative to work authorized by this building permit application.
o7 , _______,-t L //b
Signature of Owner Date
■
I �Z ✓ . t' Al. ,-c ,, e , , as Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge
and belief.
Signed under th ains and p a lti -. .f . •rjury.
/ Q? /'
Print Name
7j4/ 2-6/
Signature of Owner /Agent D
SECTION 12 - CONSTRUCTION SERVICES
10.1 Licensed Construction Supervisor: Not Applicable ❑
Name of License Holder : ` v1 1, - (.;)3XV"■ S -or/ ()
License Number
P• u , ,- -)A yli-rV �� ( Mf 0Ifl t 11 1 ,0
Address n Expiration Date ,,I z /13 ---,CA - .1
14,, Signature Telephone
SECTION 13 - WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes 52) No
Versionl.7 Commercial Building Permit May 15, 2000
•
SECTION 9- PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES - FOR BUILDINGS AND STRUCTURES SUBJECT TO
CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116 (CONTAINING MORE THAN 35,000 C.F. OF ENCLOSED SPACE)
9.1 Registered Architect: '` /� p
ft^,--1./.& �1 ` I'cYC.�u t Not Applicable ❑
Name (Registrant): qS
n ,, /� S
b l +v D ((-- I i/ lrl," . D I D66 Registration Number
Address
S l�0'wS� 5�E� - /1 j „L , Expiration Date
ESL � _
Signature Telephone
9.2 Registered Professional Engineer(s):
Name Area of Responsibility
Address Registration Number
Signature Telephone Expiration Date
Name Area of Responsibility
Address Registration Number
Signature Telephone Expiration Date
Name Area of Responsibility
Address Registration Number
Signature Telephone Expiration Date
Name Area of Responsibility
Address Registration Number
Signature Telephone Expiration Date
9.3 General Contractor /'
716N-,e -e,r- CGS D'Cs Not Applicable ❑
Company Name: {
D2. C6)o`�tZ
Resporsibll e In Charge of Construction
.D. . ec.. 1 L-kG" U . lil'\. , /1)14 ' ob6,
Addres ,w e a_
( i * /i3 'Ll - •J 'I- 2/
Signature Telephone
Versionl.7 Commercial Building Permit May 15, 2000
8. NORTHAMPTON ZONING
Existing Proposed Required by Zoning
This column to be filled in by
Building Department
Lot Size
Frontage
Setbacks Front
Side L: R: L: R.
Rear
Building Height
Bldg. Square Footage
Open Space Footage
(Lot area minus bldg & paved
parking)
# of Parking Spaces
Fill:
(volume & Location)
A. Has a Special Permit /Variance /Finding ever been issued for /on the site?
NO 0 DON'T KNOW YES 0
IF YES, date issued:
IF YES: Was the permit recorded at the Registry of Deeds?
NO 0 DON'T KNOW 0 YES
IF YES: enter Book Page! and /or Document #
B. Does the site contain a brook, body of water or wetlands? NO 0 DON'T KNOW 0 YES 0
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained i3 Obtained , Date Issued:
C. Do any signs exist on the property? YES NO i
IF YES, describe size, type and location:
D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO
IF YES, describe size, type and location:
E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES 0 NO
IF YES, then a Northampton Storm Water Management Permit from the DPW is required.
Versionl.7 Commercial Building Permit May 15, 2000
SECTION 4- CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000
CUBIC I=EET OF ENCLOSED SPACE
Interior Alterations /Existing Wall Signs ❑ Demolition ❑ Repairs ❑ Additions ❑ Accessory Building ❑
Exterior Alteration ❑ Existing Ground Sign ❑ New Signs ❑ Roofing ❑ Change of Use ❑ Other ❑
Brief Description Enter a brief description here. a i \ rzn utop e., ( tA - t t (. ;
Of Proposed Work: J
SECTION 5 - USE GROUP AND CONSTRUCTION TYPE
USE GROUP (Check as applicable) CONSTRUCTION TYPE
A Assernbly A -1 p A -2 ❑ A -3 ❑ 1A ❑
A -4 ❑ A -5 ❑ 1B ❑
B Business 12 2A ❑
E Educational ❑ 2B I ❑
F Factory ❑ F -1 ❑ F -2 ❑ 2C ❑
H High Hazard ❑ 3A ❑
Institutional ❑ 1 -1 ❑ 1 -2 ❑ 1 -3 ❑ 3B ❑
M Mercantile ❑ 4 ❑
R Residential ❑ R -1 ❑ R -2 ❑ R -3 ❑ 5A ❑
S Storage ❑ S -1 ❑ S -2 El 5B 1 ❑
U Utility ❑ Specify:
M Mixed Use ❑ Specify:
S Special Use ❑ Specify:
COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND /OR CHANGE IN USE
Existing Use Group: Z%A-> `' -• Proposed Use Group: SPA -9--.
Existing Hazard Index 780 CMR 34):. Proposed Hazard Index 780 CMR 34):
SECTION 6 BUILDING HEIGHT AND AREA
BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY
Floor Area per Floor (sf)
15t 1st
2nd 2 nd
3rd
3
4 th
4
Total Area (sf) Total Proposed New Construction (sf)
Total Height (ft)
Total Height ft
7. Watepply (M.G.L. c. 40, § 54) 7.1 Flood Zone Information: 7.3 Sewage D System:
Public Private ❑ Zone Outside Flood Zone[.] Municipal [e21:
On site disposal system El
Versionl.7 Commercial Building Permit May 15, 2000
;,.� Department ;use only
City of Northampton Status of Permit,
Y Building Department Curb Cut/Driveway Permit -
AUG 2 0 at 212 Main Street Sewer /SepticAvailabiiity
Room 100 Water/Well Availability
pt.E : FECT� N rthampton, MA 01060 Two Sets of Structural Plans
1 43RTH'''''
n e 413 - 587 -1240 Fax 413 - 587 1272 Plot/Site Plans
Other Specify
APPLICATION TO CONSTRUCT, REPAIR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUILDING
OTHER THAN A ONE OR TWO FAMILY DWELLING
SECTION 1 - SITE INFORMATION
1.1 Property Address: This section to be completed by office
C S PVC St Map Lot Unit
Zone Overlay District
(�•
(Al1Y�iv• r1 `'" "" " "") Elm St. District CB District
SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT
2.1 Owner of Record:
Name (Print) Current Mailing Address: U lUL,'L
n . 4 .113 - S. z ' 1Z 53
Signature IL' k � , i. L .. • I/ Pty Telephone
2.2 Authorized Agent:
?∎ ' A nV P*0 - . arp 114S N/7`e ' A64 •
Name (Print) Current Mailing Address: 0fv6(
Signature Telephone
SECTION 3 - ESTIMATED CONSTRUCTION COSTS
Item Estimated Cost (Dollars) to be Official Use Only
completed by permit applicant
1. Building Z3' ?az, ' (a) Building Permit Fee
fry
2. Electrical (b) Estimated Total Cost of
Z, ilbTh• (Iv Construction from (6)
3. Plumbing
l\) 1 J A Building Permit Fee
4. Mechanical (HVAC) //
5. Fire Protection (A1
6. Total = (1 + 2+ 3 +4 +5) ZS r 3617 • pp Check Number i�/
This Section For Official Use Only
Building Permit Number Date
Issued
Signalure:
Building Commissioner /Inspector of Buildings Date
File # BP- 2013 -0184
APPLICANT /CONTACT PERSON PIONEER CONTRACTORS
ADDRESS /PHONE PO Box 1145 NORTHAMPTON (413) 586 -5491
PROPERTY LOCATION 85 MAIN ST
MAP 17C PARCEL 211 001 ZONE GB(100)/ ��v✓
THIS SECTION FOR OFFICIAL USE ONLY: t.
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out //"
Fee Paid
Typeof Construction: REMOVE ONE OFFICE,ENCLOSE OFFICE & NEW CEILING TILE
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
_ Owner/ Statement or License 017890
3 sets of Plans / Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INF9 MATION PRESENTED:
h _Approved Additional permits required (see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§
Intermediate Project: Site Plan AND /OR Special Permit With Site Plan
Major Project: Site Plan AND /OR Special Permit With Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received & Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission _ Permit DPW Storm Water Management
Demolition Delay
Signa re of Building Official Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health, Conservation Commission, Department
of public works and other applicable permit granting authorities.
Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of
Planning & Development for more information.
85 MAIN ST BP- 2013 -0184
GIS #: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 17C - 211 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: renovation BUILDING PERMIT
Permit # BP- 2013 -0184
Project # JS- 2013- 000305
Est. Cost: $25300.00
Fee: $144,00 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: PIONEER CONTRACTORS 017890
Lot Size(sct ft.): 25482.60 Owner: FLORENCE SAVINGS BANK
Zoning: GB(100)/ Applicant: PIONEER CONTRACTORS
AT: 85 MAIN ST
Applicant Address: Phone: Insurance:
PO Box. 1145 (413) 586 -5491 Workers Compensation
NORTHAMPTONMA01061 ISSUED ON:8/21/2012 0:00:00
TO PERFORM THE FOLLOWING WORK: REMOVE ONE OFFICE,ENCLOSE OFFICE &
NEW CEILING TILE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House # Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace /Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeTvpe: Date Paid: Amount:
Building 8/21/2012 0:00:00 $144.00
212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272
Louis Hasbrouck — Building Commissioner