Loading...
17C-211 Section 706 Accessibility The building entrance and most public spaces are handicap accessible. The scope of this project does not modify any of those existing accessibility components. The new door installed under this project shall meet current accessibility requirements Section 707 Structural The scope of this project work area does not affect any existing structural systems Section 708 Electrical The scope of this project provides limited modifications to existing electrical distribution devices and wiring. All new devices and wiring within newly installed partitions and ceilings shall comply with all applicable requirements of NFPA 70 Section 709 Mechanical The scope for this project work area does not affect the building envelope regarding energy conservation. No changes are proposed to the existing mechanical HVAC system serving the project area, other than slight modifications for distribution layout. The existing mechanical ventilation system being modified shall be adjusted to provide no less than 5 cfm per person of outdoor air and not less than 15 cfm of ventilation air per person Section 710 Plumbing Not applicable as the occupant load will be unchanged within the project work area Section 711 Energy Conservation The scope of this project does not modify any component of the building envelope END OF CHAPTER 4 REVIEW REPORT 64 Gothic Street, Suite 1, Northampton, MA 01060 1 413. 585.1512 I tax 413.586.7945 I wv v.haiarchitecture.com Section 705 Means of Egress Paragraph 705.1 Scope The existing egress requirements within the project work area are compliant with 780 CMR 8 Edition and Life Safety Code 101. One new traffic control door located in the egress corridor will meet current requirements of 780 CMR 8 Edition and Life Safety Code 101 Paragraph 705.3 Number of Exits Multiple exits serve the project area in compliance with 780 CMR 8th Edition Paragraph 705.4 Egress Doorways The new door provided under this project is a traffic control door which does not fall within any exit enclosure or egress access corridor enclosure partitions and therefore does not require a door closer. This door does not create a dead end corridor Paragraph 705.5 Openings in Corridor Walls There are no rated walls in the project area Paragraph 705.6 Dead end Corridors There are no dead end corridors existing or new in the project area Paragraph 705.7 Means of Egress Lighting, Artificial lighting in conformance with 780 CMR 8 Edition exists and shall be maintained in the means of egress in the project area Paragraph 705.8 Exit Signs A new exit sign will be added where the new traffic control door is placed within the means of egress access corridor 64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com 4. ALTERATIONS LEVEL 2 Section 701 General This project work area will comply with all requirements for Alteration Level 2 as specified in Chapter 7. No portion of the proposed project work area alters the existing conditions such that the building will become less safe than its existing condition. Requirements regarding flood hazard areas are not applicable to this project Section 702 Special Use and Occupancy Not applicable Section 703 Building Elements and Materials Paragraph 703.2 Vertical Openings No new or existing vertical floor openings are within the project work area Paragraph 703.3 Smoke Barriers No existing smoke barriers are within the project work area Paragraph 703.4 Interior Finish All new interior finishes, including wall, ceiling, floor, and trim materials to be installed under this project work area will comply with 780 CMR 8th Edition. The work area is less than 50% of the total floor area, hence finishes in exits and corridors are not required to be modified by this project Paragraph 703.5 Guards No new or existing guards are part of the project work area Section 704 Fire Protection An approved automatic fire protection system exists throughout the building and will not be modified as part of this project A fire alarm system, compliant with 780 CMR 8 Edition, 527 CMR, and the International Fire Code, exists within the project work area and will not be modified as part of this project 64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.15 "12 I fax 413.586.7945 I www.haiarchitecture.com Section 606 Structural See Section 707 below Section 607 Energy Conservation See Section 711 below 64 Gothic Street, Suite 1, Northampton, MA 01060 I 4 13. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com 3. ALTERATIONS LEVEL 1 Section 601 General This project work area will comply with all requirements for Alteration Level 1 as specified in Chapter 6. No portion of the proposed project work area alters the existing conditions such that the building will become less safe than its existing condition. Requirements regarding flood hazard areas are not applicable to this project Section 602 Building Elements and Materials Paragraph 602.1 Interior Finishes All newly installed interior wall and ceiling finishes shall comply with 780 CMR 8 Edition Paragraph 602.2 Interior Floor Finishes All newly installed interior floor finishes shall comply with 780 CMR 8th Edition Paragraph 602.3 Interior Trim All newly installed interior trim materials shall comply with 780 CMR 8th Edition Paragraph 602.4 Materials and Methods All new work shall comply with materials and methods requirements of 780 CMR 8 Edition and other applicable codes cited in the International Existing Building Code Section 603 Fire Protection See Section 704 below Section 604 Means of Egress See Section 705 below Section 605 Accessibility See Section 706 below 64Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I tax 413.586.7945 I www.haiarchitecture.com 2. CLASSIFICATION OF WORK The proposed project work area is classified as Alteration - Level 2 per EIBC Section 402 and therefore complies with the provisions of Chapter 6 and Chapter 7 as reviewed in the following sections. The scope of work is limited to: • demolition of one existing office • installation of one new traffic control door • installation of office systems furniture cubicles • modification of existing suspended acoustical ceiling systems • upgrade of wall and floor finishes • modification of existing and installation of new general illumination Tight fixtures • installation of new exit sign to match building standard • rebalancing of existing HVAC system This project's construction costs will not exceed 30% the assessed value of the entire building The project completion is expected in summer 2012 64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com 1. GENERAL INFORMATION A. PROPERTY NAME: Florence Savings Bank B. ADDRESS: 85 Main Street, Florence, Massachusetts 01062 C. BUILDING USE: The building was originally constructed as, and continues to be used for, B- Business occupancy. D. BUILDING USE GROUP: B- Business as defined by the Massachusetts Building Code. This project will not change the Building Use Group. E. CONSTRUCTION CLASSIFICATION: Newer Portions Type 2A (protected) Foundation: concrete slab on grade; cast in place concrete walls Exterior Walls: face brick/ concrete masonry unit Int. Load Bearing: concrete columns / steel floor joists/ concrete floor slabs Roof: concrete roof slab / flat membrane roofing Original Building Type 3B (unprotected) Foundation: concrete slab on grade; cast in place concrete walls Exterior Walls: face brick/ concrete masonry unit Int. Load Bearing: wood frame partitions / wood floor joists/ wood floor sheathing Roof: wood framing / pitched shingle roofing F. HAZARD INDEX: Existing and proposed Hazard Index is 4 as defined by the Massachusetts Building Code. 64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I tax 41.3.586.7945 I www.haiarchitecture.ccm 780 CMR 8 Edition International Existing Building Code 2009 Renovations for Mortgage Origination Department Florence Savings Bank Purpose This Report is in conformance with Massachusetts Building Code 780 CMR 8 Edition and the International Existing Building Code 2009 Chapter 4 regarding alterations (Mortgage Origination Department) to an existing building, Florence Savings Bank, 85 Main Street, Florence, Massachusetts. Limitations of review The extent of this review is limited to visual inspection of existing facilities and /or as -built documentation only. No destructive testing was performed as part of this analysis. 64 Gothic Street, Suite 1, Northampton, MA 01060 I 413. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com Existing Conditions Evaluation Report 780 CMR 8 Edition International Existing Building Code 2009 Renovations for Mortgage Origination Department Florence Savings Bank 85 Main Street Florence, Massachusetts 01062 June 26, 2012 *' 5t EK AN ��� K AT 4 ' � : ' o. 1 TON AtHUSETT Al r: pared b p P Y Richard E. Katsanos, AIA, Principal H I AI Architecture 64 Gothic Street, Suite 1, Northampton, NIA 01060 I 413. 585.1512 I fax 413.586.7945 I www.haiarchitecture.com CITY OF NORTHAMPTON, MASSACHUSETTS CONSTRUCTION CONTROL AFFIDAVIT PROJECT NUMBER: 12 -015 DATE: June 26, 2012 PROJECT TITLE: Renovations for Mortgage Origination Department PROJECT LOCATION: 85 Main Street, Florence, MA 01062 NAME OF BUILDING: SCOPE OF PROJECT: Interior Renovations In accordance with the Massachusetts State Building Code, 780 CMR 8 Edition, Chapter 1, Section 107.6 Construction Control, I, Richard E. Katsanos, Massachusetts Registration No. 8355, being a registered professional Architect, hereby certify that I have prepared or directly supervised the preparation of all design plans, computations, and specifications concerning architectural scope for the above named project and that, to the best of my knowledge, such plans, computations and specifications meet applicable provisions of the Massachusetts State Building Code, 8 Edition, all acceptable engineering practices and all applicable laws for the proposed project. I ENTIRE PROJECT I ARCHITECTURAL STRUCTURAL FIRE PROTECTION ELECTRICAL MECHANICAL OTHER (specify) I further certify that I shall perform the necessary professional services and be present on the construction site on a regular basis to determine that the work is proceeding in accordance with the documents approved for the building permit and shall be responsible for the following as specified in Section 107.6.2.2 Construction: 1. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in Chapter 17. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the construction documents and this code. Pursuant to Section 107.6, I shall submit periodically, a progress report together with pertinent comments to the Building Inspector. Upon completion of the work, I shall submit a final report and an affidavit of completion as to the satisfactory completion and readiness of the project for .g4lu.,eancy. RED A a ,,,, , , c , j Y.AT S4 :', Subset' .14 and sworn to before me <<, 2 1 ,; this .._#: g ay of___, 20 IQ No. 8355 N t I1- i , WESTHhMPTON , �� � / / /, MASSAC� �[ /���� 43,-11-z. 1 . \ �'' v .. -- Notary Public . ,I,,,..,i,,, �� r I , atsanos, AIA My Commission expires on . , ., ' . e:..04/ , tt Q (.> • 26 20q . A: 'c �. • :: ..'-a 11: .ci l) cs,cn 1 T. 2 'kg SSAC , \f • . � ��∎ • a 9 ��,- 10 csaschnsctta ' =`�' -- �` "__ • V DEPARTMENT OF BUILDING INSPECTIONS • 212 Main Street • Municipal Building Northampton, Mass. 01060 or " WORIOR' S COMPENSATION INSURANCE A l I, Pioneer Contractors - (licenser/permi tree) with a principal place of business/residence at: • P.O. Box 1145 Northampton, M2. 01-061 (phone #) 586 5491 - (e =t/city /state /cep) do hereby certify, under the pains and penalties of perjury, that: ( 1 am an employer providing the following worker's compensation coverage for Ivy employees working on this job: • Wcc 50059570120012 Asccrriater1 Employers Insuranr'e Co - - -- - 6 / 1 0/Ia (Insurance: Compan (Policy Number) (Expiration Date) ( ) 1 am a sole proprietor, general contractor or homeowner (circle one) and have hired the contractors listed below who have the following worker's compensation policies: (Name of Contractor) (Insurance Company/Policy Number) (Exp rntion Date) (Name of Contractor) (Insurance Company/Poliey Number) (Expiration Date) • (Naive of Conn - actor) (bnsurance Company/Policy Number) (Entrain Date) (Name of Contractor (Insurance Company/Policy Number) (Expiration Date) (anach additiocal shxet if nn , • ry to meludc information pertaining to all ooctracton) ( ) 1 am a sole proprietor and have no one working for me. ( ) lam a home owner performing all the work myself NOTE: please be aware that while homeowners who employ pawns to do orcalutconace, construction or repair work on a dwelling of not meat than threo units in which the bocnnowocr maid= or oat the grounds appurtenant theccto arc not go rally ooatidc+cd to be cenploytt-a tmdcr the worker`s ceccPcctsttlica Act (GL151 1(5)), application by a. homeowner fora ri==ms= or permit may evidence the legal' atatua of an employer under tho • Worircls Compo iiioa Act_ I underataad that a copy of this AYrunm4 may bo fotward.ed to tho Department ofIndumial Accidence Of600 of Inzunnco for the covent,3c unification and that feilurc to foot= covcrago under section 25A of MQL 152 c:tn Iesd to the imposition of criminal pcasltics cocesisoatg of a fine of up to S1,300.00 and/or impri5occmccEt of up to one year and civil penalties in tbo form of a Stop Work Ord= and a - fine of 5100.00 a day against me. - / / t r Fa dcputm i Luc cnh' ijiilzoa - Lot # Permit Number .t. A. Pr maps rS . Si.. true ofLiccnscefPermi • - _ • Versionl.7 Commercial Building Permit May 15, 2000 SECTION 10- STRUCTURAL PEER REVIEW (780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No SECTION 11 - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Mate' - 60w, Cu^- er, /,. fa&-s as Owner of the subject property hereby authorize 2l0 4"Anr- (4W U �ti to act on my behalf, in all matters relative to work authorized by this building permit application. o7 , _______,-t L //b Signature of Owner Date ■ I �Z ✓ . t' Al. ,-c ,, e , , as Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under th ains and p a lti -. .f . •rjury. / Q? /' Print Name 7j4/ 2-6/ Signature of Owner /Agent D SECTION 12 - CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder : ` v1 1, - (.;)3XV"■ S -or/ () License Number P• u , ,- -)A yli-rV �� ( Mf 0Ifl t 11 1 ,0 Address n Expiration Date ,,I z /13 ---,CA - .1 14,, Signature Telephone SECTION 13 - WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes 52) No Versionl.7 Commercial Building Permit May 15, 2000 • SECTION 9- PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES - FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116 (CONTAINING MORE THAN 35,000 C.F. OF ENCLOSED SPACE) 9.1 Registered Architect: '` /� p ft^,--1./.& �1 ` I'cYC.�u t Not Applicable ❑ Name (Registrant): qS n ,, /� S b l +v D ((-- I i/ lrl," . D I D66 Registration Number Address S l�0'wS� 5�E� - /1 j „L , Expiration Date ESL � _ Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor /' 716N-,e -e,r- CGS D'Cs Not Applicable ❑ Company Name: { D2. C6)o`�tZ Resporsibll e In Charge of Construction .D. . ec.. 1 L-kG" U . lil'\. , /1)14 ' ob6, Addres ,w e a_ ( i * /i3 'Ll - •J 'I- 2/ Signature Telephone Versionl.7 Commercial Building Permit May 15, 2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R. Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg & paved parking) # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES IF YES: enter Book Page! and /or Document # B. Does the site contain a brook, body of water or wetlands? NO 0 DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained i3 Obtained , Date Issued: C. Do any signs exist on the property? YES NO i IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15, 2000 SECTION 4- CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC I=EET OF ENCLOSED SPACE Interior Alterations /Existing Wall Signs ❑ Demolition ❑ Repairs ❑ Additions ❑ Accessory Building ❑ Exterior Alteration ❑ Existing Ground Sign ❑ New Signs ❑ Roofing ❑ Change of Use ❑ Other ❑ Brief Description Enter a brief description here. a i \ rzn utop e., ( tA - t t (. ; Of Proposed Work: J SECTION 5 - USE GROUP AND CONSTRUCTION TYPE USE GROUP (Check as applicable) CONSTRUCTION TYPE A Assernbly A -1 p A -2 ❑ A -3 ❑ 1A ❑ A -4 ❑ A -5 ❑ 1B ❑ B Business 12 2A ❑ E Educational ❑ 2B I ❑ F Factory ❑ F -1 ❑ F -2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ Institutional ❑ 1 -1 ❑ 1 -2 ❑ 1 -3 ❑ 3B ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R -1 ❑ R -2 ❑ R -3 ❑ 5A ❑ S Storage ❑ S -1 ❑ S -2 El 5B 1 ❑ U Utility ❑ Specify: M Mixed Use ❑ Specify: S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND /OR CHANGE IN USE Existing Use Group: Z%A-> `' -• Proposed Use Group: SPA -9--. Existing Hazard Index 780 CMR 34):. Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor (sf) 15t 1st 2nd 2 nd 3rd 3 4 th 4 Total Area (sf) Total Proposed New Construction (sf) Total Height (ft) Total Height ft 7. Watepply (M.G.L. c. 40, § 54) 7.1 Flood Zone Information: 7.3 Sewage D System: Public Private ❑ Zone Outside Flood Zone[.] Municipal [e21: On site disposal system El Versionl.7 Commercial Building Permit May 15, 2000 ;,.� Department ;use only City of Northampton Status of Permit, Y Building Department Curb Cut/Driveway Permit - AUG 2 0 at 212 Main Street Sewer /SepticAvailabiiity Room 100 Water/Well Availability pt.E : FECT� N rthampton, MA 01060 Two Sets of Structural Plans 1 43RTH''''' n e 413 - 587 -1240 Fax 413 - 587 1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT, REPAIR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be completed by office C S PVC St Map Lot Unit Zone Overlay District (�• (Al1Y�iv• r1 `'" "" " "") Elm St. District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: Name (Print) Current Mailing Address: U lUL,'L n . 4 .113 - S. z ' 1Z 53 Signature IL' k � , i. L .. • I/ Pty Telephone 2.2 Authorized Agent: ?∎ ' A nV P*0 - . arp 114S N/7`e ' A64 • Name (Print) Current Mailing Address: 0fv6( Signature Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building Z3' ?az, ' (a) Building Permit Fee fry 2. Electrical (b) Estimated Total Cost of Z, ilbTh• (Iv Construction from (6) 3. Plumbing l\) 1 J A Building Permit Fee 4. Mechanical (HVAC) // 5. Fire Protection (A1 6. Total = (1 + 2+ 3 +4 +5) ZS r 3617 • pp Check Number i�/ This Section For Official Use Only Building Permit Number Date Issued Signalure: Building Commissioner /Inspector of Buildings Date File # BP- 2013 -0184 APPLICANT /CONTACT PERSON PIONEER CONTRACTORS ADDRESS /PHONE PO Box 1145 NORTHAMPTON (413) 586 -5491 PROPERTY LOCATION 85 MAIN ST MAP 17C PARCEL 211 001 ZONE GB(100)/ ��v✓ THIS SECTION FOR OFFICIAL USE ONLY: t. PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out //" Fee Paid Typeof Construction: REMOVE ONE OFFICE,ENCLOSE OFFICE & NEW CEILING TILE New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: _ Owner/ Statement or License 017890 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF9 MATION PRESENTED: h _Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management Demolition Delay Signa re of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 85 MAIN ST BP- 2013 -0184 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17C - 211 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit # BP- 2013 -0184 Project # JS- 2013- 000305 Est. Cost: $25300.00 Fee: $144,00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: PIONEER CONTRACTORS 017890 Lot Size(sct ft.): 25482.60 Owner: FLORENCE SAVINGS BANK Zoning: GB(100)/ Applicant: PIONEER CONTRACTORS AT: 85 MAIN ST Applicant Address: Phone: Insurance: PO Box. 1145 (413) 586 -5491 Workers Compensation NORTHAMPTONMA01061 ISSUED ON:8/21/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: REMOVE ONE OFFICE,ENCLOSE OFFICE & NEW CEILING TILE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeTvpe: Date Paid: Amount: Building 8/21/2012 0:00:00 $144.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner