Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
16B-001-040
(\JO City of Northampton Assistant Commissioner and Zoning Enforcement cmiller 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 30. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3 31. Dryer duct maximum equivalent length is 25' including the transition section or per manufacturer's specs. 780 CMR M1502.4.4.1, no screwed connections. 32. Concealed dryer ducts are required to have a label within 6' of the dryer connection stating the equivalent length and risk of fire. See CMR 780 M1502.4.5 33. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 34. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1" clearance for 5' from the duct outlet for all fireplaces 35. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 36. Ignition barriers in place before final. 780 CMR R316. 37. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 38. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 39. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 40. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 41. Smoke and CO detectors as required. 780 CMR R314 and R315. 42. Closets beneath stair which have doors must be drywalled with /2 ". 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmiller(cz�northamptonma.gov Thank you for your cooperation in this .tter. Chuck Mill- 16. Foundation anchor bolts must be %2" and be embedded a minimum of 7" into the concrete. 10" bolts! 780 CMR R403.1.6 17. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common are required at each connection. 780 CMR R802.3.1. 18. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 / 3rd 780 CMR R802.3.1 19. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 20. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 21. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 22. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 23. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended 24. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4 25. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. Order restrictors. 780 CMR R612.2 26. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 %" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 27. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 83/4", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 28. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1. 29. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 16ga. strap must extend a minimum of City of Northampton N Y rP Massachusetts f Z Al � DEPARTMENT OF BUILDING INSPECTIONS `P '" 212 Main Street • Municipal Building f r. Northampton, MA 01060 ' si - , INSPECTOR Saloomey Construction Tony Balotti PO Box 1203 Westfield, MA 01086 June 07, 2012 Map Block: 16B — 001 — 040 Location: 40 Mark Warner Drive Mr. Balotti: The plans for the Single Family Residence dated 5 -21 -2012 have been approved as noted; 1. Any roof section which does not have ceiling joist or rafter ties in the bottom 1/3` of the rafter connecting one side to the other requires an engineered solution. (structural ridge) 2. Structure must conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 3. Energy aspects must comply the stretch energy code. (appendix 115AA) 4. All sill plates must be properly attached with a minimum of two bolts per section. 5. A complete window and header schedule is required. 6. Initial and final HERS ratings, duct blast test results. 7. Grading plan for the house being constructed. 8. Smoke and CO detectors as required per code. 9. All framing materials which are not code prescriptive must have engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss d. Front braced wall line 10. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. a. The Sunroom and Garage sections require specific braced wall solutions. b. All corners must be appropriately attached to the foundation; some braced wall systems require additional anchor bolts. 11. HVAC system requires a sheet metal permit. a. Manual J calculation room by room b. Equipment data with sizing and efficiencies c. Line drawing with CFM amounts for supplies and returns These items must be submitted to the building department for approvals before a rough inspection can occur. As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 12. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments. 13. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 14. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 15. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. • . Af fl ° ISKAdl � .; 141 Vi H ilary a'1 . .' _ �,..... usrtt. it� 1 �. ' ... - DEPARTMENT OF BUILDING INSPECTIONS ` � , INSPECTOR 212 Main Street 0 -Municipal Bu dins 1 Northampton, MA 01060 we LOCATION 400 8r t ""c/ e R b `d /Nark liar 1 <'r Dri v . SQUARE FOOTAGE AMOUNT BASEMENT @ :20 I5s 3(0.00 1 @ .50 / 33-0 / 7J, 00 . 1 2 FLR @.30 : CU - : aSCf.!JO l FLOORS, Fl ISH ATTIC, GARAGE @ .20 t()00 . . DECK/PORCHES @ :20" - I (Q _ 33• 00 TOTAL.. iqc9,c.4 • . -`—� -� The Common of Massachusetts 5 ).`e--1141--,V Department of Accidents , \ :w Office ofInees1Ig'1ions 600 Washngton Street 1 *i -�... Boston, Mass. 02111 v Workers' Compensation Insurance Affidavit In .f•• i "b4r s'3te i - it�' l' rCgP:Z4VVVA0eMgrg:= ..c fli.?�TQ.rdtfit.ia 4'}".•., ei,„-, ?.. �'.-"' azzs 'ig,3= `r4-'�.r:gw4r,> name: location: city phone # I am a homeowner performing all work myself. 0 I am a sole proprietor and have no one working in any capacity • - ',.z?r7,� -5' .17 h�t;:g,•.�z'.,. .wrIlltei:,.., ... ..leer&'2......._ , r i ��• . r. �i ,. t"vv,:s.i. xwA 1riA:2i /44'•^",s,�ls.�..1: ;?rzgsg-": g I am an employer providing workers' compensation for my employees working on this job. company name: SalOOmey . COn stY 'L7Cti017`. : ::: address: - .... . :, :•, :. -:.... ... :. •:. .. . W Ma 4::1.086 : ;;.. ..-::: >.:::: 2£'9:= 4:3 `: >::.. •:. city: . • insurance co. Mass Employers Ins. Co. poiic #: hl ,E• .2001 2 - 200 -:- :. z�".zirsti.�rl,�s"�e.�%.� !Z:�, *;,S g'lh^!,Y*Z-k'qT ls�"'.gC.i�'�ZiM!�.z�..�i;`..<:;, " ,. ngF ,V%I ,.; "; ,,,, . fn : s. 0 I am a sole proprietor, general contractor, or homeowner (circle one) and have hired the contractors listed below who have the following workers' compensation polices: • company name: address: • city: phone: #: .::.. . insurance co. . : • . ; :..-;;;:' .. - s .. 7-"- ' ' �'. e :r`' `��o %.r�`l.:.-- �! - <K-.41FN - �". f° u9 ".':': � • `r,�bv'<� , S"+.- A":W <7�;��it..'..' Klw l//!�,� .4 •;� -af+ -r company name: - - • address: : : city: - ` phone #: . . . : - insurance co. ..• ...;,. :....•• .- .,.Policy: #:.;..; :..::;:;".: .... .. • :•. • ......•. . (i4 .1 Attac h_add;bgnsb`'s �� .:. E-,=" ���,�,'��..;f:a2.�'�.7 ' �a'�^ -..� °� eCr��.:!�:��'�'�5�-�,, rr? °Fi,�.!Ax,��% ;.,��. Failure to secure coverage as required under Section 25A of MGL 152 can lead to the imposition of criminal penalties of a fine up to 51,500.00 and /or one years' imprisonment as well as civil penalties in the form of a STOP WORK ORDER and a fine of 5100.00 a day against me. I understand that a copy of this statement may be forwarded to the Office of Investigations of the DIA for coverage verification. 1 do hereby rtifi under the pa a d,,enalties of perjury that the information provided above is tru and correct. � Signature � n o C %� 1 Da[e ( t / 1 Printnae • Merri yn A. Gag — Office Manager Phoned (41 ) 269 -4360 m 4 official use only do not write in this area to be completed by city or town official city or town: permit/license # °Building Department - []Licensing Board sg ` ❑ check if immediate response is required °Selectmen's Office °Health Department contact person: phone #; °Other - :;,a w --- .... -� ,, ..: nv.•- '_o..,. •..... K-- •.- -_-c, -.. ..,..; 2t ..•: .---:x ...p.. -�� 7 .,• • t rcvucd li95 PIA) SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder : ZITER SALOOMEY 018780 License Number P.O. BOX 1203, WEstfield, MA 01086 11/13/13 Address Expiration Date 11.1 1►mot - 531 -0062 '.natur• Tele• one L 9. Registered Home Improvement Contractor: Not Applicable ❑ SALOOMEY CONSTRUCTION, INC. 100978 Company Name Registration Number P.O. BOX 1203, WEstfield, MA 01086 6/24/12 Address Expiration Date Telephone 413 269 - 4360 SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes IX No ❑ 11. - Home Owner Exemption The current exemption for "homeowners" was extended to include Owner - occupied Dwellines of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the buildin! permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg & paved parking) # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DONT KNOW 0 YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES IF YES: enter Book Page and /or Document # B. Does the site contain a brook, body of water or wetlands? NO i%" DONT KNOW © YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained O , Date Issued: C. Do any signs exist on the property? YES ® NO V IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES ® NO IF YES, describe size, type and location: E. Will the construction activity disturb ( ea ing, grading,, ®vation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) • New House E Addition ❑ Replacement Windows Alteration(s) n Roofing n Or Doors 0 Accessory Bldg. ❑ Demolition El New Signs [D] Decks [q Siding [D] Other [CO Brief Description of Proposed Work: NEW CONSTRUCTION "C" STYLE UNIT, PER AT'T'CH DRAWINGS Alteration of existing bedroom Yes No Adding new bedroom Yes No ' Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll - Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family X Two Family Other b. Number of rooms in each family unit: / Number of Bathrooms aZ s c. Is there a garage attached? Y q f d. Proposed Square footage of new construction. �� ``�" Dimensions ` (o' ' % e. Number of stories? a- f. Method of heating? GAS Fireplaces or Woodstoves Y Number of each 1 g. Energy Conservation Compliance. Y Masscheck Energy Compliance form attached? Y h. Type of construction %, (0 wO (a i. Is construction within 100 ft. of wetlands? Yes X No. Is construction within 100 yr. floodplain Yes X No j. Depth of basement or cellar floor below finished grade Ft- k. Will building conform to the Building and Zoning regulations? Yes No I. Septic Tank City Sewer X Private well City water Supply X SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT ZTTF.R SATIX)MEY , as Owner of the subject property hereby authorize TONY BILOTTA to act on my behalf, in all matters relative to work authorized by this building permit application. — 5/24/12 na re of Owner Date ZITER SALOOMEY , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. ZITER SATOOMKY Print Name a--- r / 5/24/12 �-S ofOwner/Agent y Date 7 • _ Department use only City of Northampton Status of Permit: I -- 5 2012 Building Department Curb Cut/Driveway Permit 212 Main Street Sewer /Septic Availability L oT cr' Room 100 Water/WeII Availability NORTHAPdF �ti�1 °�0 Northampton, MA 01060 Two Sets of Structural Plans phone 413 - 587 - 1240 Fax 413 - 587 - 1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be completed by office 4S Bridge Rd. LLC Map J Lot 6 b l Unit 6t # u MARK WARNER DRIVE ', / BEAR HILL ESTATES Zone ! Overlay District NORTHAMPTON, MA 01060 Elm St District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: 20 Bridge Road LLC P.O. Box 1203, Westfield, MA (1n86 Name (Print) Current Mailing Address: 413-269-4360 Telephone atur 2.2 Authorized Agent: Ziter Saloomey or Tony Fri lnf -ta P.O. Box 1203, Westfield, MA 01086 Name (Print) Current Mailing Address: ZITER 413 531 - 0062 or TONY 413 244 - 8601 Si r Telephone SECTION 3 - ESTIMATED CONSTRU ON COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building $234,343.00 (a) Building Permit Fee 2. Electrical $ 6,800.00 (b) Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee $ 12,410.00 4. Mechanical (HVAC) $ 10, 300.00 5. Fire Protection 6. Total = (1 + 2 + 3 + 4 + 5) $263,853.00 Check Number ,y$' 5 c,f/ 1Si /16.0 This Section For Official Use Only Building Permit Number: I sssuu ed: Signature: Building Commissioner /Inspector of Buildings Date File # BP- 2012 -1068 APPLICANT /CONTACT PERSON SALOOMEY CONSTRUCTION ADDRESS/PHONE P 0 BOX 1203 WESTFIELD (413) 269 -4360 PROPERTY LOCATION 40 MARK WARNER DR - 20 BRIDGE RD MAP 16B PARCEL 001 040 ZONE SR/URA/WP THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out l/ i� ` "/ s . Fee Paid /7; */ / 1 16 le Typeof Construction: CONSTRUCT 2 STORY SFH W /ATT GARAGE/PORCH - STYLE C New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 018780 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF9RMATION PRESENTED: 6/ Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay 6/71 i-2— Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 40 MARK WARNER DR - 20 BRIDGE RD BP- 2012 -1068 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 16B - 001 CITY OF NORTHAMPTON Lot: -040 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: New Single Family House BUILDING PERMIT Permit # BP- 2012 -1068 Project # JS- 2012- 001848 Est. Cost: $263853.00 Fee: $1465.60 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SALOOMEY CONSTRUCTION 018780 Lot Size(sq. ft.): Owner: 20 BRIDGE ROAD LLC Zoning: SR/URA/WP Applicant: SALOOMEY CONSTRUCTION AT: 40 MARK WARNER DR - 20 BRIDGE RD Applicant Address: Phone: Insurance: P 0 BOX 1203 (413) 269 -4360 Workers Compensation WESTFIELDMA01086 ISSUED ON:6/8/2012 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /ATT GARAGE /PORCH - STYLE C POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 6/8/2012 0:00:00 $1465.60 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner