6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3
the depth not closer than 2" from the top or bottom. Notches are different.
30. Dryer duct transition is limited to 8' of aluminum flex and must be exposed. 780 CMR M1502.4.3
31. Dryer duct maximum equivalent length is 25' including the transition section or per manufacturer's
specs. 780 CMR M1502.4.4.1, no screwed connections.
32. Concealed dryer ducts are required to have a label within 6' of the dryer connection stating the
equivalent length and risk of fire. See CMR 780 M1502.4.5
33. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4
34. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work
maintaining 1" clearance for 5' from the duct outlet for all fireplaces
35. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302.
36. Ignition barriers in place before final. 780 CMR R316.
37. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC.
a. An initial HERS evaluation is required including insulation levels anticipated.
b. A final HERS evaluation confirming code requirements have been met including duct testing.
c. Energy information including mechanical equipment posted on the electric panel.
d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star
Building Option Package.
38. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is
a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air
flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion).
A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has
to be absolute and complete. If air can leak through an electrical device or through a crack it follows the
path of least resistance and carries 99% of the moisture in a structure. This is evident every time one
exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through
the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements.
39. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4.
40. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks
are engineered for post attachment supporting a railing.
41. Smoke and CO detectors as required. 780 CMR R314 and R315.
42. Closets beneath stair which have doors must be drywalled with %'. 780 CMR R302.7
Relevant items must be submitted to the building department for approvals before inspections and or CO can be
signed. Other items are intended to avoid costly issues at inspections.
Chuck Miller
City of Northampton
Assistant Commissioner and Zoning Enforcement
Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday
through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email
address is: cmiller c(D northamptonma.gov
Thank you for your cooperation in this matter.
Chuc, k1 iller
16. Foundation anchor bolts must be %2" and be embedded a minimum of 7" into the concrete. 10" bolts!
780 CMR R403.1.6
17. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties
and may require up sizing of rafters and increased nailing for example with a 4" slope 8 -16nd common
are required at each connection. 780 CMR R802.3.1.
18. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1 / 3rd 780 CMR
R802.3.1
19. Ridge boards must be the full depth of the cut. 780 CMR R802.3.
20. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and
number of jack studs required.
21. All framing materials which are not code prescriptive must have stamped engineering.
a. LVLs
b. I -joist and or Floor Truss
c. Roof truss
22. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780
CMR 602.10.
a. Garage corners and large corner window /door layout may require special solutions.
b. All corners must be appropriately attached to the foundation.
23. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a
shower head is used, 6'8" for basements, 6'4" at beams /ducts. 780 CMR R305.1. MA amended
24. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas,
bathtubs within 60" if not 60" above the walking surface, and other locations. 780 CMR R308.4
25. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4"
sphere rule. Order restrictors. 780 CMR R612.2
26. Egress and emergency escape requirements shall be strictly met.
a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310
b. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft
at 1 floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1
c. Two doors remote as possible at the normal level of travel, opening measured from the face of
the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR
R311.2
d. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 3/4" from
the top of the threshold and only in- swinging doors. 780 CMR R311.3
27. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ",
maximum riser 8 maximum overall variance for the run is 3/8 ", 4" sphere rule on risers except where
the total rise is 30" or less 780 CMR R311.7.4.3 Exception, 4 3/8" on balustrade, 6" in the triangle.
Graspable rail 13/4" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or
more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780
CMR R311.7.
28. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than
30" above floor or grade within 36 ", 4" sphere rule. 780 CMR R312.1.
29. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR
R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge,
In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in
bearing walls if more than 50% of a plate is cut or notched a 1 16ga. strap must extend a minimum of
City of Northampton
Massachusetts
DEPARTMENT OF BUILDING INSPECTIONS
212 Main Street • Municipal Building
�-- Northampton, MA 01060 4 �; -
INSPECTOR
Saloomey Construction
Tony Balotti
PO Box 1203
Westfield, MA 01086
June 07, 2012
Map Block: 16B- 001 -039
Location: 39 Mark Warner Drive
Mr. Balotti:
The plans for the Single Family Residence dated 5 -21 -2012 have been approved as noted;
1. Any roof section which does not have ceiling joist or rafter ties in the bottom 1/3` of the rafter
connecting one side to the other requires an engineered solution. (structural ridge)
2. Structure must conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments.
3. Energy aspects must comply the stretch energy code. (appendix 115AA)
4. All sill plates must be properly attached with a minimum of two bolts per section.
5. A complete window and header schedule is required.
6. Initial and final HERS ratings, duct blast test results.
7. Grading plan for the house being constructed.
8. Smoke and CO detectors as required per code.
9. All framing materials which are not code prescriptive must have engineering.
a. LVLs
b. I -joist and or Floor Truss
c. Roof truss
d. Front braced wall line
10. A braced wall plan identifying appropriate braced wall areas and braced wall method being used.
a. The Sunroom and Garage sections require specific braced wall solutions.
b. All corners must be appropriately attached to the foundation; some braced wall systems require
additional anchor bolts.
11. HVAC system requires a sheet metal permit.
a. Manual J calculation room by room
b. Equipment data with sizing and efficiencies
c. Line drawing with CFM amounts for supplies and returns
These items must be submitted to the building department for approvals before a rough inspection can occur.
As of August 4 2011 the 8 Edition MA code is the 2009 IRC with MA amendments.
In the following are some generic requirements which seem to be problematic.
This is not a substitute for purchasing and reading the MA codes.
12. Structures shall conform to 780 CMR 8 Edition 1 and 2 family building codes with MA amendments.
13. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements.
14. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I
soils (table R405.1)
15. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1.
I `� ; Q i` I I1 IIrz Ins tp a __
$ =� - l:.
._. DEPARTMENT OF BUILDING aTSPECTIONS ` _
INSPECTOR 212 Main Street i -Municipal Bui1ain, .••
Northampton, MA 01060 ...•
LOCATION 0)0 b r 4 R6 39 o r k War n far 0 r cu
SQUARE FOOTAGE AMOUNT
BASEMENT @ :20 1 5S0 3 1 0.00
1 FLOOR @ .50 1 S 7 75, oo
2 Nr1) FLR . 4 1.:00
!2 FLOORS, FINISH ATTIC, GARAGE @ 20 //q0 . tJ 0 . cx
DECK/PORCEES @ . t to 3 30 CVO
TOTAL.. ''T 1 1 4 65, (Q 0
The e Commonwealth ofMassach Massachusetts
..1_-- .-- -0 Department o jinclustrial
- - 11uice,, cfI wwsIJgaIJ.ns
t., == 600 Washington Street
I =: , ;'� Boston, Mass. 02111
.``_'- Workers' Compensation Insurance Affidavit
�I .;, _ 0. S3t3?' --"f",: e x a � :', ';;I::�e°- "J. '0r
location:
city phone R
[] I am a homeowner performing all work myself.
0 1 am a sole proprietor and have no one working in any capacity -
. _ -
I am an employer providing workers' compensation for my employees working on this fob.
company. name: SaloOme�T .COWS zl7CtlOn :.: ? _ • :'' : . ... ..:...-:•;•.:::: .......
B x 1 03
P
O
o _
address: :.:. °.,' ,,• ,,::.... ..
>. Westfield,. Ma. 0.:1.086..... .. ::• <: : ;:.:: :..-- __a1.:.p:: ' ::• ::::`.: •`. :::: :
panne >rt
insurance co.. Mass Emlolovers Ins. Co . : . ... - 611 . c: . * M .E ..2001 2.1,01 :200 .
0 I am a sole proprietor, general contractor, or homeowner (circle one) and have hired the contractors Listed below who have
the following workers' compensation polices:
company name-
address: "
city: - • phone:T-
insurance co. "policy
,.. ..T .. -c .w �- y"`.:. 'e.^.•=.s —' ,.' .= .1... `'W..,,y argoo.vs . '�•,
com _panv name:
address:
city: phone:
insurance co. .. ::. :.... - .....olicvR ... ; :•. .. ' .: ... ': : ..
? +,a ch $
_ "' aostiansl;'s �ue ' �. �. �. - b�M: � �S7` ,w�� 1
Failure to secure coverage as required under Section 2 5A of MGL 152 can lead to the imposition of criminal penalties of a fine up to 51,500.00 and/or
one nears' imprisonment as well as civil penalties in the form of a STOP WORK ORDER and a fine of 5100.00 a day against me. I understand that a
copy of this statement may be forwarded to the Office of Investigations of the DI.A for coverage verification.
i
1 do hereby raerti�� i t under the pain a dpenalties ofperjury that the information provided above is true)and correct.
SiQna re ✓ �U� 1 � f Dace � / true and
,L —; ` 1/9
Print name -Merrilyn A. Gagne' — Office Manacrer Phone 47 ) 269 -4360
offcial use only do not write in this area to be completed by city or town official 9 .. -
4
city or town: permit/license T QBuilding Department
Licensing Board hn
Q check if immediate response is required QSelectmen's Office g
QHealth Department
contact person: . phone #; [(Other kd
- - mow.: �.:—' �°• �, �• ci "�"�.� .., . _.:- .,...��.:.:... - ..
(1,,sed 3195 PIA)
SECTION 8 - CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor: Not Applicable ❑
;carne of License Holder : ZITER SALOOMEY 018780
License Number
P.O. BOX 1203, WEstfield, MA 01086 11/13/13
Address Expiration Date
—4;1-3=531-0062
Signatur' 7 Telep ne
/ /
/
9. Registered Home Improvement Contractor: Not Applicable ❑
SALOOMEY CONSTRUCTION, INC. 100978
Company Name Registration Number
P.O. BOX 1203, WEstfield, MA 01086 6/24/12
Address r Expiration Date
%� °� ✓ � � Telephone 413 269 - 4360
■
SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes No ❑
11. - Home Owner Exemption
The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families
and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts
as supervisor. CMR 780, Sixth Edition Section 108.3.5.1.
Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there
is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm
structures. A person who constructs more than one home in a two - year period shall not be considered a homeowner.
Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be
responsible for all such work performed under the building permit.
As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon
completion of the work for which this permit is issued.
Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to
Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s)
you hire to perform work for you under this permit.
The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of
Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated.
Homeowner Signature
4
SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable)
New House n Addition ❑ Replacement Windows Alteration(s) n Roofing I
Or Doors 0
Accessory Bldg. n Demolition 1111 New Signs [El] Decks [[J Siding [0] Other [0]
Brief Description of Proposed
Work: NEW CSNSTRU ION 11 ��_ 1 IT PER AWV D' A IN
Alteration of existing bedroom Yes No Adding new bedroom Yes No
Attached Narrative Renovating unfinished basement Yes No
Plans Attached Roll - Sheet
5a. If New house and or addition to existing housing, complete the following:
a. Use of building : One Family X �Two Family Other
'7
b. Number of rooms in each family unit: / Number of Bathrooms y
c. Is there a garage attached? Y G�a
d. Proposed Square footage of new construction_ Dimensions z-/t ? ) �� _AVM
e. Number of stories? a
f. Method of heating? GAS Fireplaces or Woodstoves Y Number of each 1
g. Energy Conservation Compliance. Y Masscheck Energy Compliance form attached? Y
h. Type of construction 9X ( 'w oodt
i. Is construction within 100 ft. of wetlands? Yes X No. Is construction within 100 yr. floodplain Yes X No
j. Depth of basement or cellar floor below finished grade Cc
k. Will building conform to the Building and Zoning regulations? Yes No .
I. Septic Tank City Sewer X Private well City water Supply X
SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
7TTFR SAT fOMFY , as Owner of the subject
property
hereby authorize TONY BILOTTA
to act on my behalf, in all matters relative to work authorized by this building permit application.
5/24/12
r Signature of Owner ,'' Date
ZITER SALOOMEY , as Owner /Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
ZITFR 5AT ,OOMFY
Print Name
5/ 24/1 2
Signature of Owner /Agent : f Date
Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information
Existing Proposed Required by Zoning
This column to be filled in by
Building Department
Lot Size
Frontage
Setbacks Front
Side L: R: L: R:
Rear
Building Height
Bldg. Square Footage
Open Space Footage
(Lot area minus bldg & paved
parking)
# of Parking Spaces
Fill:
(volume & Location)
A. Has a Special Permit /Variance /Finding ever been issued for /on the site?
NO 0 DONT KNOW 0 YES 0
IF YES, date issued:
IF YES: Was the permit recorded at the Registry of Deeds?
NO O DONT KNOW O YES O
IF YES: enter Book Page and /or Document #
B. Does the site contain a brook, body of water or wetlands? NO DONT KNOW O YES O
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained O Obtained O , Date Issued:
C. Do any signs exist on the property? YES O NO g
IF YES, describe size, type and location:
D. Are there any proposed changes to or additions of signs intended for the property ? YES O NO 4�.
IF YES, describe size, type and location:
a 3
E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES 0 NO ex
IF YES, then a Northampton Storm Water Management Permit from the DPW is required.
— RECT. - 7 Department use only
City of Northampton Status of Permit:
5 2012 Building Department Curb Cut/Driveway Permit
212 Main Street Sewer /Septic Availability
Room 100 WaterNllell Availability
C` Northampton, MA 01060 Two Sets of Structural Plans
phone 413 -587 -1240 Fax 413- 587 -1272 Plot/Site Plans
Other Specify
APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING
SECTION 1 - SITE INFORMATION
1.1 Property Address: This section to be completed by office
2CERTDGE RCPD, LIE Map Lot G , Unit �) '
#39 Mark. Warner aiw
BAR HILL ESTIMES 1 Overlay District
RCN,
Ivik 01060 `
�Im t. District CB District
SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT
2.1 Owner of Record:
20 BRIDGE ROAD, LLC P.O. Box 1203, WEstfield, MA 01086
Name (Print) 11/12 / s:
Ar Telephone
• nature
2.2 Authorized Agent:
Ziter Saloomey or Tony Bilotta P.O. Box 1203, Westfield, MA 01086
Name (Print) Current Mailing Address:
/at ` Mr Ziter (413)531 -0062 Tony (413)244 -8601
'nat re Telephone
SECTION 3 - ESTIMATED CONST ' ON COSTS
Item Estimated Cost (Dollars) to be Official Use Only
completed by permit applicant
1. Building $234,343.00 (a) Building Permit Fee
2. Electrical $ 6,800.00 (b) Estimated Total Cost of
Construction from (6)
3. Plumbing $ 12, 410.00 Building Permit Fee
4. Mechanical (HVAC) $ 10 300.00
5. Fire Protection ,
6. Total = (1 + 2 3 + 4 + 5) $263,853.00 Check Number /4e /) 5 60
This Section For Official Use Only
Date
Budding Permit Number: Issued:
Signature:
Building Commissioner /Inspector of Buildings Date
1
File # BP- 2012 -1067
APPLICANT /CONTACT PERSON SALOOMEY CONSTRUCTION
ADDRESS /PHONE P 0 BOX 1203 WESTFIELD (413) 269 -4360
PROPERTY LOCATION 39 MARK WARNER DR - 20 BRIDGE RD
MAP 16B PARCEL 001 039 ZONE SR/URA/WP
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out 14 , i/6c
Fee Paid 7
Typeof Construction: CONSTRUCT 2 STORY SFH W /ATT GARAGE/PORCH - STYLE C
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/ Statement or License 018780
3 sets of Plans / Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
IN,FQRMATION PRESENTED:
Approved Additional permits required (see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§
Intermediate Project: Site Plan AND /OR Special Permit With Site Plan
Major Project: Site Plan AND /OR Special Permit With Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received & Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission _ Permit DPW Storm Water Management
Demolition Delay
n of Building Official Date /
Signature o Bu g O
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health, Conservation Commission, Department
of public works and other applicable permit granting authorities.
* Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of
Planning & Development for more information.
39 MARK WARNER DR - 20 BRIDGE RD BP- 2012 -1067
GIS #: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 16B - 001 CITY OF NORTHAMPTON
Lot: -039 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: New Single Family House BUILDING PERMIT
Permit # BP- 2012 -1067
Project # JS- 2012- 001847
Est. Cost: $263853.00
Fee: $1465.60 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: SALOOMEY CONSTRUCTION 018780
Lot Size(sq. ft.): Owner: 20 BRIDGE ROAD LLC
Zoning: SR/URA/WP Applicant: SALOOMEY CONSTRUCTION
AT: 39 MARK WARNER DR - 20 BRIDGE RD
Applicant Address: Phone: Insurance:
P 0 BOX 1203 (413) 269 -4360 Workers Compensation
W ESTFI ELDMA01086 ISSUED ON: 6/8/2012 0:00:00
TO PERFORM THE FOLLOWING WORK:CONSTRUCT 2 STORY SFH W /ATT
GARAGE /PORCH - STYLE C
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House # Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace /Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 6/8/2012 0:00:00 $1465.60
212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272
Louis Hasbrouck — Building Commissioner