31D-031 not be removed, 7. Alterations that replace less than 50 percent of the luminaires in a space, provided that such alterations do not increase the installed interior lighting power. 8. Alterations that replace only the bulb and ballast within the existing luminaires in a space provided that the alteration does not increase the installed interior lighting power. Insulation is considered to be a part of a roof assembly in accordance with the definition in the IECC that states: ROOF ASSEMBLY. A system designed to provide weather protection and resistance to design loads. The system consists of a roof covering and roof deck or a single component serving as both the roof covering and the roof deck. A roof assembly includes the roof covering, underlayment, roof deck, insulation, vapor retarder and interior finish. In addition, the term "building thermal envelope" provides guidance on the appropriate location of insulation in this situation. The building thermal envelope is defined in IECC Section 202 as follows: BUILDING THERMAL ENVELOPE. The basement walls, exterior walls, floor, roof, and any other building element that enclose conditioned space. This boundary also includes the boundary between conditioned space and any exempt or unconditioned space. The base requirement of Section 101.4.3 is that, alterations, renovations or repairs to an existing building, building system or portion thereof shall conform to the provisions of the IECC as they relate to new construction. With respect to the reroofing of the slate roof of the Dome, the appropriate location of insulation would be at the ceiling assembly of the Dome Room that separates the conditioned space of the Dome Room from the unconditioned attic space above the Dome Room. That interior ceiling is part of the building thermal envelope. Therefore, the reroofing of the slate roof of the Dome does not result in a requirement for addition of insulation to the slate roof assembly. On the other hand, the reroofing of the flat roof of Sweeney Concert Hall with a new EDPM roof falls under the requirement of Exception 5 underlined above that roofs where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. That requirement will be satisfied by the installation of a layer of rigid insulation between the roof sheathing and the new EPDM roof covering. Sage Hall, Smith College 9 May 21, 2012 Section 2 Technical Requirements International Energy Conservation Code Roof Repair and Replacement Sage Hall, Smith College In accordance with MSBC8 Section 101.4.6, the provisions of the International Energy Conservation Code shall apply to all matters governing the design and construction of buildings for energy efficiency. The following provisions concerning applicability of the IECC to specific types of projects provide some guidance on the applicability of the EBCM to the current reroofing project: 101.4.3 Additions, alterations, renovations or repairs. Additions, alterations, renovations or repairs to an existing building, building system or portion thereof shall conform to the provisions of this code as they relate to new construction without requiring the unaltered portion(s) of the existing building or building system to comply with this code. Additions, alterations, renovations or repairs shall not create an unsafe or hazardous condition or overload existing building systems. An addition shall be deemed to comply with this code if the addition alone complies or if the existing building and addition comply with this code as a single building. Exception: The following need not comply provided the energy use of the building is not increased: 1. Storm windows installed over existing fenestration. 2. Glass only replacements in an existing sash and frame. 3. Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with insulation. 4. Construction where the existing roof, wall or floor cavity is not exposed. 5. Reroofing for roofs where neither the sheathing nor the insulation is exposed. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing. 6. Replacement of existing doors that separate conditioned space from the exterior shall not require the installation of a vestibule or revolving door, provided, however, that an existing vestibule that separates a conditioned space from the exterior shall Sage Hall, Smith College 8 May 21, 2012 shall be as required for new installations. New windows in existing window locations will comply with the MSBC8 provisions for new construction and the International Energy Conservation Code. SECTION 307 CHANGE OF OCCUPANCY There will be no change of occupancy in any part of the buildings. SECTION 308 HISTORIC BUILDINGS Sage Hall is not an historic building. SECTION 309 MOVED STRUCTURES Sage Hall is not a moved structure. SECTION 310 ACCESSIBILITY FOR EXISTING BUILDINGS 310.1 Scope. Accessibility requirements shall be in accordance with 521 CMR. The proposed work will involve only roof repair and replacement and window repair and replacement. The cost of the work will be $463,000 not including $53,250 to patch and paint some existing wall and roof plaster finishes that is considered to be repair work and not including $15,000 for window shades that are considered to be furnishings. The building has a current value of $13,052,369 based on its insured value. The current project cost will be 3.3% of the insured value. In addition, the costs of the current project together with the cost of other work in the building in the past 36 months will not exceed 30% of the value of that building. They will also not exceed $500,000. As a result, Section 3.3.1(a) of the Regulations of the MA Architectural Access Board (521 CMR) will require only that the current work comply with the Access Regulations. As the current work does not involve building features affecting accessibility, 521 CMR has no impact on the current project. If the costs of the current project costs were to remain less than 30% of the value of the building but were to exceed $500,000, Section 3.3.1(b), Exception 2 of the Regulations of the MA Architectural Access Board (521 CMR) would require that there shall be an accessible entrance to the building and, if provided, accessible public toilets, telephones and drinking fountains. Those features are already in place as a result of previous work the building. Sage Hall, Smith College 7 May 21, 2012 none of these three conditions exist in Sage Hall. SECTION 304 REPAIRS 304.1 General. Buildings and structures, and parts thereof, shall be repaired in conformance with Section 301.2. Work on nondamaged components that is necessary for the required repair of damaged components shall be considered part of the repair and shall not be subject to the requirements for alterations in this chapter. Routine maintenance required by Section 301.2, ordinary repairs exempt from permit in accordance with Section 105.2, and abatement of wear due to normal service conditions shall not be subject to the requirements for repairs in this section. 304.1.1 Dangerous conditions. Regardless of the extent of structural or nonstructural damage, the code official shall have the authority to require the elimination of conditions deemed dangerous. All repairs as well as renovations and alterations will comply with the code for new construction. 304.2 Substantial structural damage to vertical elements of the lateral- force- resisting system. 304.2.1 Evaluation. 304.2.2 Extent of repair for compliant buildings 304.2.3 Extent of repair for noncompliant buildings 304.3 Substantial structural damage to gravity load- carrying components 304.3.1 Lateral force - resisting elements. 304.4 Less than substantial structural damage Requirements concerning the structural conditions in the existing building and the proposed alterations to that system are addressed in a separate report by the project's structural engineer. 304.5 Flood hazard areas. `See 780 CMR Appendix G.' The building is not located in an area subject to flood hazards. SECTION 305 FIRE ESCAPES There are no existing or proposed fire escapes in this building. SECTION 306 GLASS REPLACEMENT 306.1 Conformance. The installation or replacement of glass Sage Hall, Smith College 6 May 21, 2012 with the requirements of Section 1009 of the International Building Code where the existing space and construction does not allow a reduction in pitch or slope. 2. Handrails otherwise required to comply with Section 1009.12 of the International Building Code shall not be required to comply with the requirements of Section 1012.6 of the International Building Code regarding full extension of the handrails where such extensions would be hazardous due to plan configuration. The proposed project will include replacement of existing roof assembly components with like materials and replacement of existing windows with new windows that meet or exceed current code requirements for energy conservation characteristics. Some energy code considerations related to the reroofing project are discussed in Section 2. 303.2 Flood hazard areas. See 780 CMR Appendix G.' The building is not located in an area subject to flood hazards. 303.3 Existing structural elements carrying gravity load. 303.3.1 Design live load. 303.4 Existing structural elements carrying lateral load. 303.4.1 Seismic 303.5 Voluntary seismic improvements Requirements concerning the structural conditions in the existing building and impact of the proposed changes to that system are addressed in a separate report by the project's structural engineer. 303.6 Means of Egress Capacity Factors. For means of egress capacity refer to Section 102.2.2.1. EBCM Section 102.2.2.1 requires that the following conditions shall be corrected in all existing buildings: 1. Less than the number of means of egress serving every space and /or story, required by Chapter 10 of EBCM8; 2. Any required means of egress component, which is not of sufficient width to provide adequate exit capacity in accordance with section 1005.1 of the EBCM8; 3. Any means of egress which is not so arranged as to provide safe and adequate means of egress, including exit signage and emergency lighting in accordance with Chapter 10. A review of existing occupant loads present and egress capacities provided indicates Sage Hall, Smith College 5 May 21, 2012 Section 1 Technical Requirements EBCM Chapter 3, Prescriptive Compliance Method Roof Repair and Replacement Sage Hall, Smith College SECTION 301 GENERAL 301.2.1 Existing materials. Materials already in use in a building in conformance with requirements or approvals in effect at the time of their erection or installation shall be permitted to remain in use unless determined by the code official to be dangerous to life, health or safety. Where such conditions are determined to be dangerous to life, health or safety, they shall be mitigated or made safe. The are no materials in the Sage Hall that result in conditions that are dangerous to life, health or safety. 301.2.2 New and replacement materials. Except as otherwise required or permitted by this code, materials permitted by the applicable code for new construction shall be used. Like materials shall be permitted for repairs and alterations, provided no hazard to life, health or property is created. Hazardous materials shall not be used where the code for new construction would not permit their use in buildings of similar occupancy, purpose and location. All new materials will comply with or exceed code requirements based on Construction Type IIIB and other material restrictions such as interior ceiling, wall and floor finish requirements. SECTION 302 ADDITIONS This building is not being expanded as a result of this project. SECTION 303 ALTERATIONS 303.1 General. Except as provided by Section 301.2 or this section, alterations to any building or structure shall comply with the requirements of the code for new construction. Alterations shall be such that the existing building or structure is no less conforming with the provisions of this code than the existing building or structure was prior to the alteration. Exceptions: 1. An existing stairway shall not be required to comply Sage Hall, Smith College 4 May 21, 2012 the applicable requirements of Chapters 4 through 12 of the code. The Work Area Compliance Method focuses upon upgrading of the work area itself with only limited requirements outside the work area. A basic concept of this method is that the required upgrades shall be based on the level of work being done in the building. The third option is the "Performance Compliance Method" in which repairs, alterations, additions, changes in occupancy and relocated buildings shall comply with Chapter 13 of the code. The Performance Compliance Method may be considered a quantitative compliance alternative method in which a point or values system is used to evaluate the total safety of the building. In that system, the points assigned for a feature of the building that exceeds the minimum requirements of the code for new construction is recognized as compensating for features that fall below the minimum required by strict new code compliance. It is proposed to regulate the proposed renovations using the Prescriptive Compliance Method as the most appropriate of the three options. The details of application of that method to the current project are summarized in Section 1. The primary energy code considerations related to the reroofing of portions of the building are discussed in Section 2. Sage Hall, Smith College 3 May 21, 2012 The proposed work is will include the following: • Replacement of 7 large Archtop windows including 6 Archtop windows in Sweeney Concert Hall and 1 Archtop windows in Sage Stairwell • Replacement of 8 round windows in the Dome Room • Replacement of slate on the Dome roof • Replacement of copper flashing and gutters on the Dome roof • Replacement of EPDM of the Sweeney Concert Hall roof • Plaster Repair and Paint in Sweeney Concert Hall No work within the interior of the building is proposed except incidental work resulting from the roof work and the repair and painting of plaster ceiling and walls in Sweeney Concert Hall. There will be no change of occupancy of the building or expansion of the building as a result of the project. Code Applicability In accordance with MSBC8 Section 3401.1, the alteration, repair, addition, and change of occupancy of existing buildings shall be controlled by the provisions of the International Existing Building Code 2009 (IEBC 2009) and its appendices as modified by Massachusetts Amendments. Those documents, taken together, are identified as the Existing Building Code of Massachusetts (EBCM). The requirements of the EBCM specifically applicable to the Smith College Sage Hall reroofing project are summarized below. Basic EBCM Requirements The EBCM offers three alternatives for regulation of work in existing buildings: (1) the "Prescriptive Compliance Method ", (2) "Work Area Compliance Method" and (3) the "Performance Compliance Method ". These three approaches are considered mutually exclusive: that is, a project must be based on one of those three method and complete the requirements applicable to that method. The first method is the "Prescriptive Compliance Method" in which repairs, alterations, additions and changes of occupancy complying with Chapter 3 of the EBCM and also complying with the International Fire Code shall be considered in compliance with the provisions of this code. In essence, this method requires that only the work area be brought into compliance with the new building requirements of the MSBC8. For example, the fire protection systems required by MSBC8 Chapter 9, determined by the overall building aggregate area in Table 903.2, must be provided only in the work area. The second method is the "Work Area Compliance Method" that requires that repairs, alterations, additions, changes in occupancy and relocated buildings shall comply with Sage Hall, Smith College 2 May 21, 2012 — Harold R. Cutler, P.E. Fire Safety, Building and Access Code Consultant 165 Landham Road Sudbury, MA 01776 -3156 Voice & fax 978- 443 -7088 Email hcutlercfpe@verizon.net Summary of EBCM Requirements Reroofing Project Sage Hall, Smith College Northampton, MA This Code Summary is based upon the Existing Building Code of Massachusetts (EBCM). The EBCM consists of the 2009 Edition of the International Existing Building Code and the MA amendments to that code documented in Chapter 34 of the Eighth Edition of the Massachusetts State Building Code (MSBC8). Basic data concerning the existing Sage Hall and the proposed renovations of that building are provided below. Existing Building Description The existing building has three stories above grade that include an occupied attic space that is considered a story of the building. It also has a single basement below grade. The highest level is a penthouse with a domed roof. The footprint area of the building is 16,600 sf. The aggregate area on all floors is 41,680 sf. The building is of Type IIIB construction based on its exterior bearing masonry walls and interior unrated combustible and non - combustible framing and floor and roof assemblies. The building is fully sprinklered and provided with a fire alarm system that is activated by heat detectors, manual pull stations and the waterflow detector of the sprinkler system. The building contains elements of a college classroom, administrative and performing arts building including lecture halls, a concert hall, and faculty and administrative offices. Those uses are assigned to Use Groups B and A -3. Proposed Work Sage Hall, Smith College 1 May 21, 2012 mds6performance.txt Configuration: Standard Bottom Rail - ogee sticking operation: Stationary Energy Efficiency U value: 0.30 Energy Efficiency R value: 3.33 solar Heat Gain Coefficient: 0.29 visible Light Transmittance: 0.49 condensation Resistance: 57 Energy Star: N,NC,SC Egress and venting are only provided for rectangular units. U Value R value and Solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. Product Performance Report unit 6 Unit Name: 06M (Mull component of Unit TYPE L) Call Number: CUCART- CUSTOM- RT24 Frame Size: 22 5/8" x 47 1/16" Subtype: 1 5/8" sash Glazing Type: Low E II Argon Glazing Thickness: 3/4" Insulating Glazing Color: obscure configuration: Standard Bottom Rail - ogee Sticking Operation: Stationary Energy Efficiency U value: 0.30 Energy Efficiency R value: 3.33 Solar Heat Gain Coefficient: 0.29 Visible Light Transmittance: 0.49 Condensation Resistance: 57 Energy Star: N,NC,SC Egress and venting are only provided for rectangular units. u Value R Value and solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. 0 Page 3 mds6 e. o' rmance.txt p (Mull component of Unit TYPE L) ' (� T • call Number: CUAWN- CUSTOM , 4 4 r Frame Size: 40" x 31 1/2" Subtype: 1 5/8" sash Glazing Type: Low E II Argon Glazing Thickness: 3/4" Insulating Glazing Color: obscure Configuration: Standard Bottom Rail - ogee sticking Operation: Operating Daylight Opening: 6.09 Sq Ft Ventilation: 6.42 Sq Ft Energy Efficiency u value: 0.30 Energy Efficiency R value: 3.33 solar Heat Gain Coefficient: 0.26 Visible Light Transmittance: 0.44 Condensation Resistance: 56 Energy Star: N,NC,SC,S Design Pressure: DP50 U Value R value and solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical support. Product Performance Report Unit 4 Unit Name: 04M (Mull component of Unit TYPE L) Call Number: CUCART CUSTOM RT6 Frame size: 40" X 22 5/8" subtype: 1 5/8" sash Glazing Type: Low E II Argon Glazing Thickness: 3/4" Insulating Glazing Color: obscure configuration: standard Bottom Rail - ogee sticking Operation: Stationary Energy Efficiency u value: 0.30 Energy Efficiency R Value: 3.33 Solar Heat Gain coefficient: 0.24 visible Light Transmittance: 0.40 Condensation Resistance: 57 Energy Star: N,NC,SC,S Egress and venting are only provided for rectangular units. U value R Value and Solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. Product Performance Report unit 5 Unit Name: 05M (Mull component of Unit TYPE L) Call Number: CUCART - CUSTOM RT23 Frame Size: 22 5/8" X 47 1/16" Subtype: 1 5/8" sash Glazing Type: Low E II Argon Glazing Thickness: 3/4" Insulating Glazing Color: obscure Page 2 mds6performance.txt Marvin windows & Doors, MDS Version 18.1.0, Build 1133, 3/14/2012 MDS RB Tabs version 18.1 Build 920 MDS RB Code Version 18.1 Build 1132 Product Performance Report 1 Unit Name: O1M / (Mull component of Unit TYPE K) ( R ` OUVI cL / Call Number: CUAWN - CUSTOM Frame Size: 40" X 40" Subtype: 1 5/8" Sash Glazing Type: Low E II Argon Glazing Thickness: 3/4" Insulating Glazing Color: Obscure Configuration: Standard Bottom Rail - Ogee Sticking operation: Operating Daylight Opening: 8.11 Sq Ft ventilation: 8.48 Sq Ft Energy Efficiency U value: 0.30 Energy Efficiency R Value: 3.33 Solar Heat Gain coefficient: 0.26 visible Light Transmittance: 0.44 Condensation Resistance: 56 Energy Star: N,NC,SC,S Design Pressure: DP50 U Value R Value and solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. Product Performance Report unit 2 Unit Name: 02M (Mull Component of Unit TYPE K) Call Number: CUCART - CUSTOM RT6 Frame Size: 40" x 22 5/8" subtype: 1 5/8" Sash Glazing Type: Low E II Argon Glazing Thickness: 3/4" Insulating Glazing color: Obscure Configuration: standard Bottom Rail - ogee Sticking operation: Stationary Energy Efficiency u Value: 0.30 Energy Efficiency R Value: 3.33 Solar Heat Gain coefficient: 0.24 visible Light Transmittance: 0.40 Condensation Resistance: 57 Energy Star: N,NC,SC,S Egress and venting are only provided for rectangular units. U value R value and solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. Product Performance Report unit 3 Unit Name: 03M Page 1 mdsl3performance.txt Subtype: 1 7/8" Sash Glazing Type: Low E II Argon Glazing Thickness: 1" Insulating Glazing Color: Clear Configuration: Standard Bottom Rail - ogee Sticking Operation: Stationary Daylight Opening: 28.67 Sq Ft Energy Efficiency U Value: 0.30 Energy Efficiency R value: 3.33 Solar Heat Gain Coefficient: 0.26 visible Light Transmittance: 0.44 Condensation Resistance: 55 Energy Star: N,NC,SC,S Egress and venting are only provided for rectangular units. u value R value and Solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. Product Performance Report Unit 4 Unit Name: TYPE Cl Call Number: CUCAP - CUSTOM Frame size: 65" X 66 11/16" Subtype: 1 7/8" Sash Glazing Type: Low E II Argon Glazing Thickness: 1" Insulating Glazing Color: Clear Configuration: Tall Bottom Rail 3 9/16" - ogee Sticking Operation: Picture Daylight Opening: 24.42 Sq Ft Energy Efficiency U value: 0.30 Energy Efficiency R Value: 3.33 Solar Heat Gain Coefficient: 0.29 visible Light Transmittance: 0.50 Condensation Resistance: 56 Energy Star: N,NC,SC,S Design Pressure: DP50 U Value R value and solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. D Page 2 mdsl3performance.txt Marvin windows & Doors, MDS Version 18.1.0, Build 1133, 3/13/2012 MDS RB Tabs Version 18.1 Build 920 MDS RB Code Version 18.1 Build 1132 Product Performance Report Unit 1 Unit Name: TYPE B Call Number: CUCART - CUSTOM- RT2 Frame Size: 76 1/2" X 107 7/16" Subtype: 1 7/8" Sash Glazing Type: Low E II Argon Glazing Thickness: 1" Insulating Glazing Color: Clear Configuration: standard Bottom Rail - ogee sticking Operation: Stationary Daylight Opening: 46.16 Sq Ft Energy Efficiency u value: 0.31 Energy Efficiency R value: 3.23 Solar Heat Gain Coefficient: 0.26 visible Light Transmittance: 0.44 Condensation Resistance: 55 Energy star: NC,SC,S Egress and venting are only provided for rectangular units. U value R Value and solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. Product Performance Report unit 2 Unit Name: TYPE B1 Call Number: CUCAP - CUSTOM Frame Size: 76 1/2" x 93 1/16" subtype: 1 7/8" Sash Glazing Type: Low E II Argon Glazing Thickness: 1" Insulating Glazing Color: Clear Configuration: Tall Bottom Rail 3 9/16" - Ogee Sticking Operation: Picture Daylight Opening: 42.11 Sq Ft Energy Efficiency U Value: 0.30 Energy Efficiency R value: 3.33 Solar Heat Gain Coefficient: 0.29 visible Light Transmittance: 0.50 Condensation Resistance: 56 Energy Star: N,NC,SC,S Design Pressure: DP50 u Value R value and solar Gain values exclude the effect of Dividers. For STC values click Product Info. To verify critical performance values contact Marvin Technical Support. Product Performance Report Unit 3 Unit Name: TYPE C Call Number: CUCART - CUSTOM- RT2 Frame Size: 65" X 81 15/16" Page 1 i Z R o i- EI H r a a �� $ 7 r _ -__ _ �' I H �I m HEAD soA,E. s _,.� MULLION s�a�E. s _ $ d . Illitiii s g t , I ,� HEAD a JAMB JAMB 4 * '--- 1 1111 ° e e . , o CU �A�E e ( ; - rddddd It i-,, - r 11181111` f MULLION SIL & .-- —r w W mss' f C '. J ,, v 0 p CA MULLION O NOT USED `p n - u � .. . MULLION j a l . s _,. _66.4. s _, �� 1 I I I - - - ,zn MULLION v� SILL F , m O R N X —M � al N .- N 8 s 51 SILL En USED CC MULLION _ -0 SILL -0 DIVIDER - 2 J _ - OF 2 k. 1 i 64. m 'I 0 !_ r "l _ !I � II 16 £ It r. 4 ro' Y s 5 - 1 I ° V, , � 4 . : _ 11 1 1 ]I 1 I L I _I , 11 � I I { I� I! I I , o ‘, a l s . ° P' '" - -.. , °HEo 1 � T_ N 1 I I I '` J � -II / I o m h 11 1 � 11; I _= j II 22A , 24, r wl 8 7 QO aE � 'I° I f X 1 1 v� - w _- "i DISTRBUTOR A. W. HASTINGS 6 CO., LLC OFRldIGPROOUCIS WI HREFSTO11110PDRAfl4Ot: Cq DEALER : HERRINGTON' Oabn miring w Ma. P.M. end Door pads Mutated. in CONTRACTOR ass Flop em.P o. . a copy ad P.A. imam,. M. r' ARCHITECT SMITH COLLEGE ss,N.a..N..,� F.„a4 a.�,. b..m � wwwmatmorm Maslow. 6 Wan P 0 1.103 Warw. IMF... DRAWING NO 27042.dwg DRAWN BY SCha,omanski SAGE AND SWEENEY u • ..°WO en40he the QM Os .nm •• , .......O li.......O F p P.P. matlFUbn M1.Apa DATE: 02128112 REVISION DATE: AcORU® CERTIFICATE OF LIABILITY INSURANCE 2/15/2012rn THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Diane Wojcik NAME: Coakley Pierpan Dolan & Collins Insurance PHONE (413) 664 -9366 FAX (413) 664 -6504 (A/C Nn. eft): (A/C, No): 26 Union Street ADD : dwojelk @cpdcinsurance.com INSURERS) AFFORDING COVERAGE NAIL # North Adams MA. 01247 INSURER A Main Street America Ins. Co. 29939 INSURED INSURER B American Employers Iris Co T.R. WELLS CUSTOM FRAMERS LLC INSURER C : 1407 NORTH ST INSURERD: INSURER E : WINDSOR MA 01270 -9248 INSURERF: COVERAGES CERTIFICATE NUMBER:11 -12 & 12 -13 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL S W M1UBR POLICY EFF POLICY EXP LIMITS LTR INSR VD POLICY NUMBER (MDD/YYYY) (MM/DD/YYYY) GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO X COMMERCIAL GENERAL LIABILITY PREMISES (Ea 'RENTED $ 500,000 A ( CLAIMS -MADE X ( OCCUR MPK347ON 5/27/2011 5/27/2012 MEDEXP(Anyoneperson) $ 10,000 PERSONAL & ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEM. AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP/OP AGG $ 2,000,000 TO POLICY LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) $ 1,000,000 A ANY AUTO BODILY INJURY (Per person) $ ALL OWNED X SCHEDULED BOUND 2/15/2012 2/15/2013 BODILYINJURY(Peraccident) $ AUTOS X HIRED SAUTOS X A UTOS D (Per accid nt) DAMAGE $ $ X UMBRELLA LWB OCCUR EACH OCCURRENCE $ 1,000,000 A EXCESS LIAR ~ CLAIMS -MADE AGGREGATE $ 1,000,000 DED RETENTION$ BOUND 2/15/2012 2/15/2013 $ WORKERS COMPENSATION WC STATU- OTH- B X TORY LIMITS FR AND EMPLOYERS LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y / N E.L. EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N NI W CC5007523012011 8/19/2011 8/19/2012 (Mandatory In NH) E.L DISEASE - EA EMPLOYEE $ 1,000,000 If yes, describe under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is required) The Trustees of Smith College and any present or former trustee, director, officer, administrator employee, student, volunteer worker or Agent, is added as additional insured with respects to General Liability, Auto, Employers Liability when required by written contract or agreement CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Smith College ACCORDANCE WITH THE POLICY PROVISIONS. The Trustees of the Smith College Purchasing Department AUTHORIZED REPRESENTATIVE 126 West Street Northampton, MA 01063 Diane Wojcik /DIAWOJ ACORD 25 (2010/05) ©1988 -2010 ACORD CORPORATION. All rights reserved. INS025 r , nlnnl01 Thn At'-fP l nemn cnrl Innn ern rnniafnrnri marts of A('nan Version1.7 Commercial Building Permit May 15, 2000 SECTION 9- PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES - FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116 (CONTAINING MORE THAN 35,000 C.F. OF ENCLOSED SPACE) 9.1 Registered Architect: Not Applicable ❑ Name (Registrant): Registration Number Address Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date 9.3 General Contractor 7r, 1?, bkit 1)5 C " '"` i' ' Not Applicable ❑ Company Name: rc. Responsible In Charge of Construction Vol / v D."4 - et J4 (j, ,As.- 01 2) - Address E. A yl 3-Z& /- 0,1) 6 Sign Telephone Version1.7 Commercial Building Permit May 15, 2000 SECTION 10- STRUCTURAL PEER REVIEW (780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No SECTION 11 - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT t A. G, 6 0 A , as Owner of the subject property hereby authorize T' 12 ' Cie/LS Cis 40-0,— / . s L L L to act on eatters relative to work authorized by this building permit application. ! a, �I 0. Signature of Owner Date 1, y 4. G Il. a.,, ) .. ,_ f'/,'r� t '.- 1 L as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name �� C` � ` � / „I Z Signature of Owent Date SECTION 12 - CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: y' * L kS L5 412.7,r J License Number )yu7 /1A. -fit 5--- 1,00 Mc 0 /Z? 0 ‘ii (hp/ Address Expiration Date — Y — A/. 72164'-7 y/3-ZP- OJV4. Signature Telephone SECTION 13 - WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No Versionl .7 Commercial Building Permit May 15, 2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be fil • : n by Building Depa • •nt Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg & paved parking) # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO 0 DON'T KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO Q DON'T KNOW 0 YES 0 IF YES: enter Book Page and /or Document # B. Does the site contain a brook, body of water or wetlands? NO Q DONT KNOW ® YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained ® Obtained ® , Date Issued: C. Do any signs exist on the property? YES ® NO 0 IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES ® NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ® NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15, 2000 SECTION 4- CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑ Existing Wall Signs ❑ Demolition ❑ Repairs ❑ Additions ❑ Accessory Building ❑ Exterior Alteration ❑ Existing Ground Sign ❑ New Signs ❑ Roofing ❑ Change of Use ❑ Other 5:1 Brief Description Enter a brief description here. 7 0 ^` Of Proposed Work: �- ` i '�� 1n,iT4 ' S 4yC / jc - ( r , n dvr++c. q/'C SECTION 5 - USE GROUP AND CONSTRUCTION TYPE USE GROUP (Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A -1 ❑ A -2 ❑ A -3 ❑ 1A 1 ❑ A-4 ❑ A -5 ❑ 1B ❑ B Business ❑ 2A ❑ E Educational 2B 1 ❑ F Factory ❑ F -1 ❑ F -2 ❑ 2C ❑ H High Hazard ❑ 3A ❑ 1 Institutional ❑ 1 -1 ❑ 1 -2 ❑ 1 -3 ❑ 3B ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R -1 ❑ R -2 ❑ R -3 ❑ 5A EJ S Storage ❑ S -1 ❑ S -2 ❑ 5B l ❑ U Utility ❑ Specify: M Mixed Use ❑ Specify: S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND /OR CHANGE IN USE Existing Use Group: Proposed Use Group: Existing Hazard Index 780 CMR 34): Proposed Hazard Index 780 CMR 34): SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor (sf) 1 st 1 st 2 nd 2nd 3rd 3�d 4 th 4 Total Area (sf) Total Proposed New Construction (sf) Total Height (ft) Total Height ft 7. Water Supply (M.G.L. c. 40, § 54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public ❑ Private ❑ Zone Outside Flood Zone0 Municipal ❑ On site disposal system 0 Version l .7 Commercial Building, Permit May 15, 2000 Department use only V \ City of Northampton Status of Permit f2' Building Department Curb Cut/Driveway Permit - 212 Main Street Sewer /Septic Availability (J 7.7 - --- Rotr'n 1 00 Water/Well Availability RLCaiV n, MA 01060 Two Sets of Structural Plans phone 413- 587 -12z 0 Fax 413- 587 -1272 Plot/Site Plans MAI 3 Other Specify 6 i f APPLICA ION(TO CONSTRUCT, REP14IR, RENOVATE, CHANGE THE USE OR OCCUPANCY OF, OR DEMOLISH ANY BUILDING nEPT OF BUILDING INSPECTIONS OTHER THAN A ONE OR TWO FAMILY DWELLING NORTHAMPTON, MA 01060 SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be completed by office ) Cpiiese f' 4,.e --- S gSr fir: # Map Lot Unit /U t r- ..r ft?' , 7 Zone Overlay District Elm St District CB District SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: j ' . 6' C Aia c/ /d C Gtics"J! sr, Nor riidfr pry, MR Name (Print) Current Mailing Address: Yt 3 - 5-2 S -- on 0 Y Signature r Telephone 2.2 Authorized Agent: we ILf i Name (Print) Curr t Mailing Address: Signature 4 6" Telephone Si/ SECTION 3 - ESTIMATETCONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building 2.y 6 0 ° (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) iq&fc YO 5. Fire Protection 6. Total= (1 +2 +3 +4 +5) ZIL, Check Number - ©�/ V9 This Section For Official Use Only Building Permit Number Date Issued Sign e: S.---g S / 2--. Bui mg Commissioner n actor of Buildings Date SAGE HALL - 1 COLLEGE LANE BP- 2012 -1062 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31D - 031 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: window replaced BUILDING PERMIT Permit # BP- 2012 -1062 Project # JS- 2012 - 001834 Est. Cost: $246900.00 Fee: $1481.40 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: WELLS CUSTOM FRAMERS LLC 66275 Lot Size(sq. ft.): 8407.08 Owner: SMITH COLLEGE OFFICE OF TREASURER Zoning: EU(100)/URC(100)/ Applicant: WELLS CUSTOM FRAMERS LLC AT: SAGE HALL - 1 COLLEGE LANE Applicant Address: Phone: Insurance: 1407 NORTH ST (413) 684 -4861 WC WINDSORMA01270 ISSUED ON:5/31/2012 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 15 REPLACEMENT WINDOWS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 5/31/2012 0:00:00 $1481.40 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner