Loading...
37-103 A CITY OF NORTHAMPTON BOARD OF PUBLIC WORKS SANITARY SEWER FORCE MAIN POLICY The purpose of this policy is to establish the guidelines, procedures, specifications and conditions associated with sanitary sewer force mains that will become the responsibility of the Department of Public Works (DPW). The following conditions shall apply: 1. All information associated with the entire force main system shall be submitted by the applicant to the DPW for approval. The information shall include, but not be limited to, technical specifications of every system component, capacity of system, operation of valves, pumps and other controlling mechanisms, installation procedures and detailed testing protocols. 2. If the force main system is part of a proposed subdivision, its installation and inspection shall conform to the City' Subdivision Rules and Regulations in addition to the conditions stated in this policy. In all other cases, its installation and inspection shall conform to applicable Rules and Regulations of the DPW in addition to the conditions of this policy. 3. Force main systems shall be designed so that individual pump chambers shall be located outside the street layout. Curb stops and check valves shall be installed at the property line. 4. No connection to the common force main system shall be allowed unless a "Municipal Sewer Availability" and "Residential or Commercial Building Sewer Application" are submitted and approved by the DPW. Attached to these documents shall be the technical specifications, manufacturer's name, model and rated capacity of the proposed pumping system. 5. Prior to the replacement or upgrade of any existing pumping system, the information requested in Item 4 above must be submitted to the DPW for approval. 6. Pumping chambers on private property shall be accessible at all times. The DPW has the right to enter said property at any time for the purpose of examining the pumping station for compliance with the regulations stated in this policy. The DPW will not be responsible for damage to any plantings or landscaping placed over or in close proximity to the pumping chamber access. 7. A red light indicating system problems /failure shall be installed outside every structure connected to the force main system. Said light shall be clearly visible from a vehicle traveling on the adjacent roadway. 8. It is the responsibility of every owner of a property/structure that is connected to the common force main to insure that all components of their service line are functioning properly and in accordance with the approved submittals. 9. Any violation to this policy may cause the service line of the structure in question to be shut -off at the curb stop. In addition, if the violation causes damages to either the common force main or to adjacent structures connected to the system, the responsible party shall bear the cost of all repairs and claims associated with said violation. 10. The DPW will become responsible only for the components of a sanitary force main system located within the layout of a City accepted street. Acceptance of a street can only be approved by the Northampton City Council. Adopted by the Board of Public Works on May 14, 2003. C:\ Policies \SanitaryForceMainsApri12003 MUNICIPAL SEWER AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 587 -1570 A Department of Public Works Trench Permit shall be require prior to any construction or connection activity associated with this application. Location: 71 Ice Pond Drive Inquiry Made By: Wright Builders 586 -8287 Date of Inquiry: October 16, 2003 Municipal Sewer Main in Front of Location: Yes X No Municipal Storm Drain Available: Yes No Size of Sewer Main: 8" Material: PVC Age: 2003 Depth of Sewer Main: S. 6 ` D Size of Service Connection: 6" Comments: "Ice Pond Drive" is a subdivision roadway that has been approved by the Planning Board. Release of this "Municipal Sewer Availability Application" by the DPW is contingent on the successful completion and approval of the sewer /water system as shown on the approved construction plans. Failure to receive this approval will involve the denial of occupancy permits by the Building Commissioner. A corresponding "sewer entrance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such installation shall be made with the Northampton Streets Department with a minimum of 5 working days notification. All work shall conform to Northampton Streets Department specifications. Storm Drain Concurrence Joseph Th mas, Sup dfintendent Douglas McDonald, Enviromental Planner g Streets Department Engineering Department cc: Ned Huntley, Asst. City Engineer Anthony Patillo, Building Inspector MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton, MA 01060 587 -1098 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 71 Ice Pond Drive Inquiry Made By: Wright Builders 586 -8287 Date of Inquiry: October 16, 2003 Municipal Water Main in Front of Location: Yes X No Size of Water Main: 8" Material: Ductile Iron Age: 2003 Approximate Street Pressure: 65 PSI Size of Service Connection: 1" Comments: The Water Department cannot guarantee adequate water pressure during peak demand times at elevations above 320 feet. This subdivision was approved by the Northampton Planning Board 02/13/03. It is the responsibility of the developer to provide the necessary infrastructure as shown on the approved plans. The City of Northampton has not accepted responsibility for maintenance of the water main and connections as of this date. A corresponding "water entrance fee" shall be paid prior to making any connection to the municipal water system. Arrangements of such installation shall be made with the Northampton Water Department with a minimum of 5 working days notification. All work shall conform to Northampt Water epart t specifications. ,....: c� ,e,/ David . Sparks, Superintendent of Water cc: Ned Huntley, Asst. City Engineer Anthony Patillo, Building Inspector • Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non - Circulating Runouts Circulating Mains and Runouts Temperature (F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170 -180 0.5 1.0 1.5 2.0 140 -160 0.5 0.5 1.0 1.5 100 -130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure /Temperature 201 -250 1.0 1.5 1.5 2.0 Low Temperature 120 -200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40 -55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) [ ] 2. Slider: Glass, U- factor: 0.310 Comments: Floors: [ ] 1. Floor 1: All -Wood Joist/Truss:Over Unconditioned Space, R -28.0 cavity insulation Comments: Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] When installed in the building envelope, recessed lighting fixtures shall meet one of the following requirements: 1. Type IC rated, manufactured with no penetrations between the inside of the recessed fixture and ceiling cavity and sealed or gasketed to prevent air leakage into the unconditioned space. 2. Type IC rated, in accordance with Standard ASTM E 283, with no more than 2.0 cfm (0.944 L /s) air movement from the the conditioned space to the ceiling cavity. The lighting fixture shall have been tested at 75 PA or 1.57 lbs /ft2 pressure difference and shall be labeled. Vapor Retarder: [ ] Required on the warm -in- winter side of all non - vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R- values and glazing U- factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts shall be insulated per Table J4.4.7.1. Duct Construction: [ ] All accessible joints, seams, and connections of supply and return ductwork located outside conditioned space, including stud bays or joist cavities /spaces used to transport air, shall be sealed using mastic and fibrous backing tape installed according to the manufacturer's installation instructions. Mesh tape may be omitted where gaps are less than 1/8 inch. Duct tape is not permitted. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Heating and Cooling Equipment Sizing: [ ] Rated output capacity of the heating/cooling system is not greater than 125% of the design load as specified in Sections 780CMR 1310 and J4.4. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non - depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] 1 HVAC piping conveying fluids above 120 ° F or chilled fluids below 55 ° F must be insulated to the levels in Table 2. [ ] 9. Window: Ice Pond C: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 10. Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 11. Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 12. Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 13. Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 14. Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 15. Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 16. Window: Ice Pond E: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 17. Window: Ice Pond E: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 18. Window: Ice Pond E: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 19. Window: Ice Pond F: Vinyl Frame, Double Pane with Low -E, U- factor: 0.340 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 20. Window: Ice Pond F: Vinyl Frame, Double Pane with Low -E, U- factor: 0.340 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 21. Window: Ice Pond F: Vinyl Frame, Double Pane with Low -E, U- factor: 0.340 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 22. Window: Ice Pond H: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Front Door: Solid, U- factor: 0.160 Comments: REScheck Inspection Checklist Massachusetts Energy Code REScheckSoftware Version 3.5 Release lb DATE: 10/20/03 TITLE: ICE POND Lot 13 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R -38.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R -19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' htJ7.0' bg/8.0' insul, R -3.1 continuous insulation Comments: Windows: [ ] 1. Window: Ice Pond A: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 2. Window: Ice Pond A: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 3. Window: Ice Pond A2: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 4. Window: Ice Pond B: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 5. Window: Ice Pond B: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 6. Window: Ice Pond B: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 7. Window: Ice Pond B: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 8. Window: Ice Pond C: Vinyl Frame, Double Pane with Low -E, U- factor: 0.380 For windows without labeled U- factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Front Door: Solid 20 0.160 3 Slider: Glass 40 0.310 12 Basement Wall 1: Solid Concrete or Masonry 912 0.0 3.1 104 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Floor 1: All -Wood Joist/Truss:Over Unconditioned Space 800 28.0 0.0 27 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the Massachusetts Energy Code requirements in RES checkVersion 3.5 Release lb (formerly MECchecl) and to comply with the mandatory requirements listed in the RES checklnspection Checklist. The heating load for this building, and the cooling load if appropriate, has been determined using the applicable Standard Design Conditions found in the Code. The HVAC equipment selected to heat or cool the building shall be no greater than 125% of the design load as specified in Sections 780CMR 1310 and J4.4. i Date � D J 0 / 0 Builder/Designer L { {{ • • Permit Number REScheck Compliance Certificate Checked By/Date Massachusetts Energy Code REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files \Check\REScheck\ICE POND Lot 13.rck TITLE: ICE POND Lot 13 CITY: Northampton STATE: Massachusetts HDD: 6404 CONSTRUCTION TYPE: 1 or 2 Family, Detached HEATING SYSTEM TYPE: Other (Non- Electric Resistance) DATE: 10/20/03 COMPANY INFORMATION: Wright Builders Inc. COMPLIANCE: Passe Maximum UA = 365 Your Home UA = 365 0.0% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R -Value R -Value U- Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 800 38.0 0.0 24 Wall 1: Wood Frame, 16" o.c. 2052 19.0 0.0 105 Window: Ice Pond A: Vinyl Frame, Double Pane with Low -E 8 0.380 3 Window: Ice Pond A: Vinyl Frame, Double Pane with Low -E 8 0.380 3 Window: Ice Pond A2: Vinyl Frame, Double Pane with Low -E 13 0.380 5 Window: Ice Pond B: Vinyl Frame, Double Pane with Low -E 13 0.380 5 Window: Ice Pond B: Vinyl Frame, Double Pane with Low -E 13 0.380 5 Window: Ice Pond B: Vinyl Frame, Double Pane with Low -E 13 0.380 5 Window: Ice Pond B: Vinyl Frame, Double Pane with Low -E 13 0.380 5 Window: Ice Pond C: Vinyl Frame, Double Pane with Low -E 13 0.380 5 Window: Ice Pond C: Vinyl Frame, Double Pane with Low -E 13 0.380 5 Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E 11 0.380 4 Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E 11 0.380 4 Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E 11 0.380 4 Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E 11 0.380 4 Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E 11 0.380 4 Window: Ice Pond D: Vinyl Frame, Double Pane with Low -E 11 0.380 4 Window: Ice Pond E: Vinyl Frame, Double Pane with Low -E 12 0.380 5 Window: Ice Pond E: Vinyl Frame, Double Pane with Low -E 12 0.380 5 Window: Ice Pond E: Vinyl Frame, Double Pane with Low -E 12 0.380 5 Window: Ice Pond F: Vinyl Frame, Double Pane with Low -E 5 0.340 2 Window: Ice Pond F: Vinyl Frame, Double Pane with Low -E 5 0.340 2 Window: Ice Pond F: Vinyl Frame, Double Pane with Low -E 5 0.340 2 Window: Ice Pond H: Vinyl Frame, Double Pane with Low -E 9 0.380 4 WiLLIAiN A. 4' owwI SCREEN 7---- - - - - - -- ' ". O wm 1 �T. w / ur wares / 11------- PROWX 1' woe e>asr. cxrwo o e / / ° �� o (f� / `\ J` / LANDSCAPE NTAL ARCHITECTURE LOT 133 / / / / ENVIRONMENTAL DESIGN / ` \ \/ ` ; Y,_ COMMUNITY D PLANNING / — / ?f raoPm+r —% — �� �' S'ITJSOS r te r. • • _ -- ��- 250 - t Elul }WIRitNJ, W 01027 -------- - _ L17.15 - - 111.. • 1 3• 3 2 7• N 5 3 5 __ _— a.- .r.��•_25 _ \ • Oflltf •CANONIA COY ■ ki '`....., 252_______,. Q y ,,, 1 'N 13 / , / §.4 ____ uy° W ... \ il _ '� Z rz, 0 \ ' � � ms' ......_..., _As, _..., ,, ../- \ '''' 1 yam_ ------/ / 0_, 2, 4 \ \ ...------ 04 •,,,.. i • \ • ' `\ _ _ 255 J / - - - - \ i!J co FILE 0 .0.: - i \\ - - __ - - - - - -- -255 -�_-� _ • 2003 \ \ . _ - —256- — — — — O if Caron trniscape Weed %CET VILE ■ • FOUNDAMON ... .\. .....„ \ \. .. ,45.",.Lo A e \ / • • P00t143(lDRAA1 \ : ,��: 1'. IOTu 1 NORTH • \ SITE / 0 3 TE PLAN SK -4 0 10' 15' 20' t 0 1" 20' SIfFf N0. 4 OF 6 - j i ! 011 y" LItU of L a�Iampthn ��^^^ ri{ass+rcausrtfs • •, .rE D E ?:' �; Vf.VT OF BUILDING INS ?E:'I'IONS 212 Main Street Municipal Building INSPECTOR p g� Northampton, Mass. 01060 Scuare Footage Amount Ba.serr ent @ ' 15 too (c. t 1st _ l cor @ , 6.0 .� (e) 3b4 2nd Floor @ .. 0 a3C) .4t 1/2 Floors, Attic, Garage ,15 Deck, Porches . ' � r j co tP f . �W )1"1() TCT FO 72 e7Y Ct `1)11 N Q " `' t, o , i -� • • • • • • WILLIAM A. • • 7----- -__ ----- ...._ 4• Flc ORlul1 OUTLET W/ SCREEN CAP ,' ,NC K R PPE wmf 12 W. STONES INV 2 e_Q oast c c / /_-___, CANON / Im 13A PROVIDE 1' W - COVER AVER / / -- \ -- / / ENVIRONMENTAL DESIGN � LANDSCAPE ARCHITECTURE / / /`' \ \ _ _ ___3a. - / ` `/ '•, COMMUNITY PLANNING l'--7,--.. ATM= - -- r- o o a .. - a.- - '�� - .�� 1 - 17 . 13 Aso _ ` 1 FASnyy MA GSi11 ---- / \ TB.. • 13•{27• {535 { FAIL ♦ 13.627• {3 OrrICc.CAON LA.CO■ TO Ie__ _�_ « `� IMIDSfiLPE ARCHITECT - 452____ -__ V ,gyp ki .. `r --•-•., 16 '''\ VCS6:516.C2..‘° / --' --' -., A�,,� 4 • CO §4 ., $ ice `` < .. - OP „ \ % \ -(s., \ .,. ....„, ,,,„...„ - .00,.... ,...-. ,,„..,„.... , , \ .., \ � _ n ___. n E , _ ...., , . , ,„ ,,„ ,,,__2,2_ y __...... __ �___ 0 p_i .......• , • � • ---- 1 ril G i .-- Or/• .. • . 253 -� / \ • • \ �\ -- - __---�-�- -- /� --\ PIi0 CT HO P514-03.0512 \ 4110 �\ - - � \\ CAD FlE \� \\� _ - -- _- - - - - -_ 0 2003 by Ificam A. Canon Ltrtdocape Architect �, `.�` © `- AO /' i ` PI Ii5O" Revered � O \ ` ` SHEET IRE �O '�`, '. �.w PallHIaKt10N IA? U • ■ NORTH - �-- {{ SITE PLAN SK-4 1 = 20' 0 10' 15' 20' —�_ —� s1fEr NO. 4 Of 6 • SECTION 8 - CONSTRUCTION SERVICES 1 Licensed Construction Supervisor: �I Q� Not Applicable El of License Holder : 49 t o /+e / / Wr-f -( i)L eM b 6 81 K ' 111 License Numb r b e-TA-(l f 1 j i 1 M q— b I o loo l lf�6 Addre Expiration Date Signature Telephone "' #tee''' E ,Imo or m n rvon ra�t ;;' A ,' E M:E ` r'7ni Not Applicable ❑ 1.-u j c,bE,e -s l NG j o 153.6 Company Name Registration Num er t Sr, N b �Me - to Mr`s a /066 b c Addr -ss Expiration Date Telephone s • SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M. G. L:° c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No ❑ a ; Ill i 'we' The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature '^CTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House )( Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors ❑ Accessory Bldg. ❑ Demolition S New Sian [ Decks [ ] Siding [ ] Other [ ] of • Brief Description of Proposed Work: .... it)tl/: ' ' / • Alteration of existing bedroom Yes ,X No Adding new bedroom Yes k No Attached Narrative ❑ Renovating unfinished basement Yes x No Plans Attached RoIIX- Sheet ❑ 61 Ifl evWlit aMir lar addition #o° isti i 'housing,` bliip ete"`` 1161( 1TWI ' a. Use of building : One Family x Two Family Other b. Number of rooms in each family unit: / Number of Bathrooms 3 c. Is there a garage attached? - V p- 1 d. Proposed Square footage of new construction. 0 � Dimensions ? 2 x ?A 11171/ e. Number of stories? - 1 1 4) 0 ( IC �{ f�/i� v f. Method of heating? NAT. CA ` II A" Fireplaces or Woodstoves N /f'1 Number of each g. Energy Conservation Compliance. i Mascheck Energy Compliance form attached? Ile Type of construction 5 J D 1. Is construction within 100 ft. of wetlands? Yes x No. Is construction within 100 yr. floodplain Yes x No j. Depth of basement or cellar floor below finished grade g ,+ k. Will building conform to the Building and Zoning regulations? .X Yes No . I. Septic Tank City Sewer A Private well City water Supply SECTION 7a OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1, G 1 kt4 -:1vsF'fr / B f°f A1. 14'iu. btc , as Owner of the subject property hereby authori IN 1 el''r eev ((D67--e 1 11" to act on my behalf, i at - r ive o work authorized by this building permit application. o Signatu o ner Date pi' G r 1 6-o it/DeAg , /l" C'- A-�-T' ei , as Owner /Authorized Agent hereby declare that the statements and information on th foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. A_ , !� ` Print Na All -...t...s■-ii. tea/ r , 9 Sign • +fe of Owner /Agent Date Section 4. • ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION Existing Proposed Required by Zoning This column to be filled in by c ( Sp Building Department Lot Size 41 1 53 Sf (c , � SF t Frontage f ' ( (P 0 Setbacks Front �g i Side L: R: L:'> • q X7 S l� �R; Rear Building Height 30 I Bldg. Square Footage % (3 b . q /6 Open Space Footage % , �r I (Lot area minus bldg & paved / 0 3 • � 111° parkig) # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit /Variance /Finding ever been issued for /on the site? NO X DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and /or Document # B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO X IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ?YES _ No IF YES, describe size, type and location: • 1 City of Northampton r s a m e , . ` ' ' � : Building Department r u e , t ". f j * , r 212 Main Street erSe ' *� `" t. Room 100 ' _ e ' Y ' , , Northampton, MA 01060 > 44 ` ' z l .' �w Phone 413 - 587 -1240 Fax 413. 587.1272 ; ' , APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING I SECTION 1- SITE INFORMATION ,This sectian to,be completed by office 1.1 Property Address: i--f 4+-13 ,,y 1 -z , , j, ,, - � E % �' 44 91 (� (N1) bit vU Ma ` i , , Lot ;� a/ Unit • r ^mss y ry i , f a ;,,,,,,_„...,,,,,, No �'fl ,- i PtD Pi d MA 0 / b . O Z o n e Overlay District 1 ' ( t Elni:S :D ict ' " N '" F 1 / CB District ' ' `- �.. ........�...�_ ,.. _ __. b ,,,tea, . _ „_w . .,_. �<,.o, „A..b SECTION 2 - PROPERTY OWNERSHIP /AUTHORIZED AGENT 2.1 Owner of Record: 't fibs(' ITA-1, {-ham LLC. 4 � c i t iY�i ; �� 1 `z • I 'Eui k -e rS ::�.f, .-os _'N 3 2 M a,'N S - r., Srg ive- b, Name (Pr' / 40 74 x Current Mailing dress: D�0 Mk 0(105” Lfig. / �, � �---~ Telephone Sig .. 4- ' ir 2.2 Authorized Agent: ( n i l " 6(01(4.e9- ' P. - ( riatelr6 `i 6A sr, NoR't- A MA' Name (Print Current Mailing Address: .- Signat Telephone SECTION ''3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building G 4 —I DID (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of . 1 i - 31 - 1 • Da Construction from (6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 14,4 ' p. 00 6. Total = (1 + 2 + 3 + 4 + 5) ` 1231"753 Check Number 671 # ' This Section For Official Use Only Building Permit Number: a 10 Date Issued:, yie Signature: Building Commissioner /Inspector of Buildings Date File # BP- 2004 -0519 APPLICANT /CONTACT PERSON Wright Builders ADDRESS/PHONE 48 Bates St (413) 586 -8287 PROPERTY LOCATION 71 ICE POND DRIVE - LOT #13 MAP 37 PARCEL 103 001 ZONE SR THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out ,9 Fee Paid 1 6 ` x 3- 0 Typeof Construction: CONSTRUCT 2 STORY SFH W /ATT GARAGE/PORCHES New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 068185 2 �.� _ //�� 3 sets of Plans / Plot Plan / /44¢;�¢'� T FO LOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: p proved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street C. e . ssion ....or Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. +°boy � v im` _ � , y DEPARTMENT OF BUILDING INSPECTIONS _ _ INSPECTOR 212 Main Street • Municipal.Building ' Northampton, MA 01060 y vow' CERTIFICATE of OCCUPANCY and USE This is to certify that permission is hereby granted under 780 CMR, sixth, edition of the Massachusetts State Building Code, allowing the occupancy or use of the premises or e structure or part thereof located at 71 Ice Pond Drive _ Lot #13 as shown on the Assessors Page# . _ 37 - , Lot# iO3 - - - - — , -Zone STt in the City of Northampton, as herein specified: CONSTRUCTION TYPE(780CMR 6) 5B USE GROUP CLASSIFICATION (780 CMR 3 - R4 OCCUPANT LOAD PER FLOOR (780 CMR Table 1008.1.2 4 0 PSF 30 PSF LIVE LOAD PER FLOOR (780 CMR Table 1606.1) 40 PSF Under the following limitations, special stipulations, and /or conditions of the permits: Special Permit Issued this 30th day of September , 20 04 Certificate of Occupancy and Use # BP - 2004- 0519 _ Authorized Department Personnel Electrical NG�/i. Elevator Fire Plumbing a k+.,_____O ::: _.._.,.„ ..... Commissioner This certificate shall be posted by the owner, in a permanent manner and in a visible location, on all floors designated as use group H, S, M, F, or B, and in every room where practicable of use group A, I, R -1, or R -2 per requirement of 780 CMR section 120.5 Posting Structures. r 71 ICE POND DRIVE - LOT #13 BP- 2004 -0519 GIS #: COMMONWEALTH OF MASSACHUSETTS Map-Block: 37 -103 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: BUILDING PERMIT Permit # BP- 2004 -0519 Project # 3S- 2004 -0733 Est. Cost: $123753.00 Fee: $855.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: 5B Contractor: License: Use Group: R4 Wright Builders_. 068185 Lot Size(sq. ft.): Owner: Community Builders, Inc. Zoning: SR Applicant: Wrig' it Builders Applicant Address: Phone: Insurance: 48 Bates St (413) 586 -8287 Workers Compensation NORTHAMPTONMA01060 ISSUED ON:11/10/03 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /ATT GARAGE /PORCHES POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: ti _ 21 - Rough: y /z /ip y "Of House # Foundation: 0 k (7. Oy • Driveway Final: m O LC S o /r v.- r . Final: -;Z Final: p� d / '� $ � +� Rough Frame: 0 ft" q - PP • o y -� Cates. Gas: Fir epartment Fireplace/Chimney: I : Y Rough: t:(-N-Oil � /� Oil: insulation: O K [/ ;7 Final: 7-,21,- 414Smoke: F +inaI: 9 Z v2$YJ ,4Z/ THIS PERMIT MAY BE VOKF)D ' THE CITY OF NORTHAMPTON UPON VIOLATIO F ANY OF ITS RULES AND REGUL TIONS. * *TEMPORARY OCCUPANCY EXPI 1/9/04 ys'. Certificate Of Occupancy Signature: FeeType: Receipt No: Date Paid: Check No:_ Amount: Building 11 /10/03 0:00:00 16748 $855.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Building Commissioner - Anthony Patiilo 6 1 �� � � i, L i , L; .,..-;..- • - ,_;,...; .. 1w /I f`� f 1 c f - CS [7 ?-,__- 7 1 PAC 74 4-/' `e ef2.2 ( 9 � , :. rev t ', 9 �� ^ � N;; � / 4 -; } l / 0 2 - 44? 4) Cp) c i r /1 . fyi bk c...) Vol-6/6 z 0 G(24-- .‘,..,. c,gtfr b.)--' 7 ,4 4 Aii V j t„, oit. 9 � h.o &x.-",d___ 7/?‘ A ., hp', t l j-4 ?/..2.4 1 7 t / /6 i Vilp i /U2 /J' e/ i ✓L l "- ?Lt ruf ./- S-6/20 t L6 Rx C , ?eig AA ( ' l' 47 7/04 / / 71 ICE POND DRIVE - LOT #13 BP-2004 -0519 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 37 - 103 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: BUILDING PERMIT Permit # BP- 2004 -0519 Project # 3S- 2004 -0733 Est. Cost: $123753.00 Fee: $855.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: 5B Contractor: License: Use Group: R4 Wright Builders_ 068185 Lot Size(sq. ft.):. Owner: Community Builders, Inc. Zoning: SR Applicant: Wrigi it Builders A2_: 71 1Vl_. i vRRI`rE - LOT 4.c Li Applicant Address: Phone: Insurance: 48 Bates St X413) 586 -8287 Workers Compensation NORTHAMPTONMAO1060 ISSUED ON :11 /10/03 0:00:00 TO PERFORM THE FOLLOWING WORK: CONSTRUCT 2 STORY SFH W /AIT GARAGE /PORCHES POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: , Footings: Rough: t .. ..2)-0/ _2 a Rough: y /,z //p y MC House # Foundation: 0 A < V - (7. 0 y Driveway Final: «0 E' 5 6 I A- y. 0K _ s � Final: % �°6 v Final: ���� f �r�, pp�� • �% Rough Frame: 0 (C q - o� 0 P • y �C . Gas: Fiaenartment / Fireplace/Chimney: `• J / / I : Y Rough: q-. O Oil: insulation. p 1K � 7' y 4i Fina1:7 - ,2 t —Oq i S�moie: __. Final: d `C 0 ',$"21 ��bk z THIS PERMIT MAY BE RVVOK 1 R' THE CITY OF NORTHAMPTON UPON VIOLATIO F ANY OF ITS RULES AND REGU . IONS. .•� Certificate of Occupancy signature: FeeType: Receipt No: Date Paid: Check No : Amount: Building 11/10/03 0:00:00 16748 $855.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Building Commissioner - Anthony Patillo