Loading...
17A-172 , • b. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32" and one 28" minimum 78" high. 780 CMR R311.2 c. Landing at each door 36" out and the width of the door minimum 36 ", maximum step 7 %" from the top of the threshold and only in- swinging doors. 780 CMR R311.3 13. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9 ", maximum riser 8 % ", maximum overall variance for the run is 3/8 ", 4" sphere rule on risers, 4 3/8" on balustrade, 6" in the triangle. Graspable rail 1 %" minimum and 2" maximum rail, height minimum 34" maximum 38 ", required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6'8" ceiling height from nosing. 780 CMR R311.7. 14. Guards 36" minimum height above walking surface, a bench is a walking surface, required for more than 30" above floor or grade within 36 ", 4" sphere rule. See 780 CMR R312.1. 15. Educate the plumber and electrician about maximum notch and hole sizes, and placement. See 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non - bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 %2 16ga. strap must extend a minimum of 6" past the cut both directions and be nailed with 8 -10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2" from the top or bottom. Notches are different. 16. Fire and draft stopping shall be completed before rough inspection. See 780 CMR R302. 17. Ignition barriers in place before final. See 780 CMR R316. 18. Energy aspects shall comply with energy code. See 780 CMR and 2009 IECC. a. Energy information including mechanical equipment posted on the electric panel. 19. Deck ledgers and post must be appropriately attached. Note: ThruLoks are engineered for post attachment supporting a railing. See 780 CMR R502.2.2.1 20. Smoke and CO detectors as required. See 780 CMR R314 and R315. Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587 -1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk -ins at 12:00 noon on Wednesdays. My email address is: cmiller northamptonma.gov Thank .yqu fay cooperation on these matters. tr Chuck MI er City of Northampton Assistant Commissioner and Zoning Enforcement cmiller ©northamptonma.gov City of Northampton o • Massachusetts w _ ' g f 1 9 R ry DEPARTMENT OF BUILDING INSPECTIONS r, 212 Main Street • Municipal Building Northampton, MA 01060 1 INSPECTOR Harlow Builders 336 Coles Meadow Road Northampton, MA 01060 October 17, 2011 Subject Location: 20 Howes Street Map Block: 17A - 172 Mr. Harlow Your plans dated 10 -17 -11 have been approved as noted. 1. Insulation must be in air tight cavity. 2. Hip rafters need sizing. 3. Ceiling joist assumed to be 2x4 16" OC #2 SPF with a ledger at the house wall. As of August 4 2011 the 8 Addition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8 addition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. See 780 CMR R401.3 for drainage requirements. 3. Where ceiling joist are not directly connected to the rafters, rafter ties are required. See 780 CMR R802.3.1. Minimum 2x4 16" OC nailed per 780 CMR Table R802.5.1(9) 4" slope 8 -16nd common at each connection. 4. Steel straps over the ridge or 1x4 minimum collar ties are required 4' OC in the upper 1/3 780 CMR R802.3.1 5. Ridge boards must be the full depth of the cut 780 CMR R802.3. 6. A complete window and header schedule is required. See 780 CMR Table R502.5 for header sizing and number of jack studs required. 7. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I -joist and or Floor Truss c. Roof truss 8. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. See 780 CMR 602.10. a. Garage corners and large corner window /door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 9. Ceiling heights minimum 7' for habitable spaces, 6'8" for bathrooms includes tub /shower area if a shower head is used, 6'8" for basement without habitable space, 6'4" at beams /ducts. 780 CMR R305.1. 10. Hazardous glazing locations, within 24" of a door, or within 60" of a stair, or across from hot tubs, spas, bathtubs within 60" if not 60" above the walking surface, and other locations. See 780 CMR R308.4 11. Windows over 72" above grade with the opening less than 24 above the finished floor shall meet the 4" sphere rule. See 780 CMR R612.2 12. Egress and emergency escape requirements shall be strictly met. a. Windows within 44" of floor, DH 3.3 sqft min window size, Casement 20 "x41" exception 5 sqft at 15t floor. Minimum clear opening 20 "x24" or 24 "x20 ". 780 CMR R310.1.1 are'""' • 1 2868 1, r 2649 11'-6" X 12'-7" 11' X 12'-7" KITCHEN DINING 2649 144.7 S.F 138 5 S F CH /\ (FP\ 8'-2" CEILINGS OAK FLOORING 19'-6" X 12' 2649 UP LIVING ROOM 238 5 S.F. FULL FOUNDATION 1 1 S F IlfRO11 - 1 2868 2635 2645 2649 22' X 5'-8 FRONT PORCH BUILT ON PIERS 1 CONCRETE STEPS UP EXISTING FIRST FLOOR PLAN . . , • r 11 - Kitchen Dining Room ) _J C A Re-finish existing 1st. floor wood flooring, landing and stairs. Living Room UP EXISTING HOUSE Existing window WHIM 1 (Co pening proposed book case NEW 22' X 10' ADDITION 2649 2649 New oak flooring 2649 2649 2649 2649 2Z PROPOSED PLAN . ...-, "ssi.......,_ '.-,...„, 4/09 y) .. • ..... . .._„, . , . . , . ... , , ... , . ' . . , VIS:‘,............................. ) v . ' , . . k . , . . , , , , . , . , .. , .„...„ -----------) l . , 0 \ . ..„.. -4, (- \ .... /". k..., 1 q\ `\ '- -------- \ ......--- ... \ , ,,,...---■• / . , ..., ' t '' ' • --' '. ' '•i°,,,, , • I J ' c c)2 1/ V 09/29/11 11:40:46 AM RESIDENTIAL PROPERTY RECORD CARD CITY OF NORTHAMPTON, MASSACHUSETTS EFFECTIVE DATE OF VALUE: JANUARY 1, 1998 PARCEL ID: 17A- 172 -001 30 HOWES ST PLOT: LIVING UNITS: 1 CLASS: R - 101 CARD #: 1 OF 1 CURRENT OWNER /ADDRESS NEIGHBORHOOD ID: 5.00 FINAL VALUE FLAG: MARKET GOSNELL JONATHAN K & LAND DATA ANNIE CROTEAU - ASSESSMENT INFORMATION - 30 HOWES ST TYPE SIZE INFLUENCE FACTORS LAND VALUE PRIME SITE 7638 124,370 PRIOR COST CURRENT FLORENCE MA 01062 LAND 124,400 124,400 124,400 BLDG 142,200 127,600 142,200 DEED BOOK: 6993 TOTAL 266,600 252,000 266,600 DEED PAGE: 162 SALES INFORMATION DEED LAST UPDATE/COST: 2 20090504 ACREAGE: 0.175 TOTAL LAND VALUE: 124,400 PDATE /COS : 0090504 DATE TYPE PRICE VALIDITY 20030117 LAND + BLD 190,000 0 LAST UPDATE /COST: 20090504 X DATE: ADDITION DATA Lower Level First Floor Second Floor Third Floor Area DATA COLLECTION INFORMATION A EFP 138 ENTRANCE CODE: UNOCCUPIED B 1sFr 216 INFORMATION SOURCE: C EFP 36 DATA COLLECTOR: AD D Wddk 120 DATE: 19991204 E F DWELLING INFORMATION G H STYLE: CONVENTIONAL YEAR BUILT: 1937 STORY HEIGHT: 2.00 ATTIC: NONE Basement: FULL TOTAL ROOMS: 7 TOTAL BEDROOMS: 3 FULL BATHS: 2 ADDITIONAL DWELLING INFORMATION Half Baths: 1 12 BASEMENT GARAGE( #CARS) ADDITIONAL FIXTURES: EXTERIOR WALLS: ASBESTOS BRICK TRIM: X UNFINISHED AREA: STONE TRIM: X 10 WD GROUND FLOOR AREA: 650 TOTAL LIVING AREA: 1516 REMODELING DATA FINISHED BASEMENT LIVING AREA: X BASEMENT RECREATION AREA: X YEAR REMODELED: 25 MASONARY FIREPLACE STACKS /OPENINGS: 1 / 1 METAL FIREPLACES: • KITCHEN REMOD (Y/N HEAT /CENTRAL A /C: BASIC BATH REMODEL (Y /N) HEATING SYSTEM: STEAM 6 EFP FUEL TYPE: GAS 6 Q COND %DESIRABILITY /UTILITY AV PHYSICAL XNTERIOR /EXT OR AVERAGE SAME OUTBUILDINGS & YARD ITEMS PERMIT DATA 26 2Fr /B TYPE QTY YR SIZEI SIZE2 GRD COND DATE PURPOSE PRICE 20080811 35,000 GAR TO RM &BATH 20051214 4,000 REPLC WINDOWS 18 1Fr NOTES: 12 23 EFP 6 • All window sills t be lx primed and fingered jointed pine. All baseboards t be primed and fingered jointed pine with a base molding #8462. Crawl space ope 1 ing to be trimmed out. A plywood door installed / magnet catches and knobs. Flooring Install 2 '/4" red + ak strip flooring, to the new seddition area. Sand flooring and apply 3 coats of urethane. (Does not includ staining if needed) We propose to fu . h the material and labor necessary for the completion of the above stated work for the sum of: Thirty Seven T i + usand Seventy Four Thpgsand Dollars. $37,074.00 Payment as folio : 55,000 upon coma letion of demolition. $15,000 upon co pletion of the foundation/backfiil, $10,000 upon co +i pletion of the water -tight shell (Roofing & Windows) 57,074 upon com + letion of the Proposal. All work to be cot 1 pieted in a workmanlike manner according to standard practices. Any alterations r deviations from the above specifications involving extra cost will be executed only upon written orders in the form of a change order, and will become an extra charge over and above the estimate. All agreements ntingent upon strikes, accidents or delays beyond our control. Owner to carry I re tornado and other necessary insurance. Our workers are vered with workman's compensation insurance. Certificate of lia ility insurance will be sent to the above address upon signing. Note: This pro 1 I may be withdrawn by Harlow Builders if not a ce ted by within 60 days. Respectfully Su I mitted by (g" , %Harlow Builders. ACCE 'I jANCE OF PROPOSA L I accept the ab t e stated prices, specifications and conditions. You are hereby authorized to d the work as specified. Payment will be made as outlined. Date a ) � - 1 Signature �'--°'°� ---- -- - Signature Mir Interior Painting (By Others) Harlow Builders Page 3 of 6 Gosnell • EXTERIOR Roofing Trim: Soffits and facia trim to match existing. Primed pine material installed around the perimeter of the roof. Roofing: We will install a white aluminum drip edge around perimeter of root Apply ice and water barrier to the entire roof surface. A 30 year architectural shingles applied over entire roof surface, shingle to match existing. All roof flashings as needed to complete. Windows: (Material Allowance of $1,400) Paradigm new construction vinyl windows with 1/2 screen, Low E glass and argon gas. Includes 6- 9/16" painted pine interior jambs. (6) 30 "15l" double hung windows. Sidin : Tyvek house wrap applied to new exterior walls _New Weather Side, Profile wall shingles installed on all new exterior walls. We will patch in existing siding where needed for a complete job. Any caulking that needs to be done will be done with silicone caulking. Gutters: We will install new heavy duty white seamless aluminum gutters and downspouts to the add' • n area. There will be approximately 44' of gutter with 2 drops and 20' of downspout. INTERIOR Electrical: (Allowance of 5500) Using existing electrical service and main circuit breaker panel in basement. Install all switches and outlets as per code. (1) CATV outlet, Crawl space lights, Exterior • ouble floodlight, All electrical as per plans. All necessary permit, material and labor to complete electrical. (Owner to supply decorative fixtures.) Telephone and cable utility comnanv fees are not included. Heating: (N /A) Insulation: (Allowance of 51,5002 Basement ceiling area will have 9" fiberglass insulation (R-30) installed. Exterior walls will have 6" fiberglass insulation (R -21) installed with a poly vapor barrier. Attic insulation to be R-38, fiberglass mutation installed. We will install fiberglass insulation around window units. We will install proper vents in ceiling areas where needed for proper ventilation. Sheetrock: 1/2 "gypsum board applied to the new walls and ceiling, fastened with 1 1/4" screws, taped, dated (3) applications and sanded to a paint ready surface. Interior Painting: (By Others) Interior trim: All door, window and base trim to match existing. Casing to be primed and fingered jointed pine with an edge molding #8200. Harlow Builders Page 2 of 6 ( osnell PROPOSAL Harlow Builders 336 Coles Meadow Rd. Northampton, Ma 01060 (413) 586 -0465 Submitted to: Jonathan Gosnell 30 Howes St. Florence, Ma. 01062 (413) 584 -6021 Page 1 of 4 September 13, 20 1 The scope of this project is to remove the existing front porch completely and to bui a 220 sq.ft. one story addition, with a crawl space, concrete foundation. We hereby submit specifications and estimates for the work to be performed. All materials and labor to complete. All permits obtained by Harlow Builders. All debris caused by construction removed by Harlow Builders. See attached drawings for details on framing and placement of fixtures. Drawings by Harlow Builders Dated 8 /11 /11 Demolition: Remove entire front porch and piers. Remove partial interior wall to create a 10' opening. Demo partial basement foundation to create a crawl space access opening. All necessary Demolition as per plans for a complete job. Site Work: Remove existing concrete sidewalk and steps. Remove and dispose of existing shrubs Excavate for a new crawl space foundation as per drawings. Backfill the foundation o grade. Spread stone inside foundation area over 6 mill poly for floor area in crawl space. Import loam for lawn area around new foundation. Grade, rake, seed and fertilize new lawn area. (Watering of lawn is owner's responsibility) Concrete: 3,000 psi poured concrete used in foundation material. Included are anchor bolts and (2) standard metal sliding vents. 42' of 16"x 8" Footing. 42' of 8"x 6' foundation walls. Framing: Sill seal applied to top of concrete wall, 2 "x 6" pressure treated sill, bolted to top of concrete all Floor system to be 2x10 kds framed at 16" O.C. Sub - flooring to be 3/4" tongue and grove advantech panels. (Glued & nailed) 2 "x 6" studs 16 "O.C. used for the exterior wall framing. 2 "x 10" kds and LVL material used for window and door header material Exterior wall sheathing to be Y:" cdx 4 ply wall sheathing. (fastened with ring shank nails) 1 2 "x 4" studs 16 "O.C. used for the interior wall framing. Stick framed roof using 2i8 kds ma4eriaL Roof pitch and overhangs to match existing. Roof sheathing to be 1/2" cdx plywood S ply. All necessary framing as per plans for a complete job. Harlow Builders Page 1 of 6 ( osneil • • HOME OWNER EXEMPTION ACKNOWLEDGEMENT The State of Massachusetts allows the homeowner the right under 780CMR 108.3.4 to act as his/her construction supervisor. The state defines "Homeowner" as, " Person(s) - who owns a parcel on which he/she resides or intends to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures. A person who constructs more than one home in a two - year period shall not be considered a home owner." The building department for the City of.Northampton wants person(s) who seek to use the hone owner exemptron,-to act as their own - construction supervisor to be aware that by doing so you become responsible for compliance with state building codes and regulations. The inspection process requires that the department be called to inspect work at various stages, which include foundation/footings (before backfill), sonotube holes (before pour), a rough building inspection (before work is concealed), insulation inspection (if required) and a final building inspection. The building department requires these inspections before the work is concealed, failure to secure these inspections can result in; failure 'to obtain a certificate of occupancy until the work can be inspected. If the homeowner hires other trades to pe work (electrical, plumbing & gas) the homeowner will be responsible 'to make sure that the trades hired secure their proper ermits in conjunction to the' building permit issued, and that they get their required inspections. Failure of the individual trades to secure the permits and inspections as required can DELAY the project until such time as the proper permits and inspections are made • understand the above. .(Home owner /resident's signature requesting exemption) I will call to schedule all required building inspections necessary for the building permit issued tome. Date Address of work location . 4 The Commonwealth of Massachusetts . _ Department of Industrial Accidents — 'ii� Office of Investigations =.'-'-' _ ,, — w 600 Washington Street ' k. �— Z� Boston, MA 02111 - Z. www.mass.gov /dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information ` ` c Please Print Legibly Name ( Business /Organiiation/Individual): \\F'w .X"� '.:s : \c'c,j'G' i 3 . • Address: .-- 3; - (c.., C_ . P \i't\ ' c.1 p■,- , kr3 City /State/Zip: C'1° \ \\0. S�1 Zvi V`\N.: � . \�\ C., � Phone. #: ( Q G` q . Are you an employer? Check the appropriate box:. . •Type of project (required): /` Ar • 1. LJ I am a employer with 'c� • . 4. 0 I am a general contractor and I 6 lo ees full and/or art fine * have hired-the sub=contractors — — = 0 New construction - -- - 2. .0 I ani a sole proprietor or partner= listed on the _attached sheet 7. 0 Remodeling • • sfi and have no employees _ _ These sub- contractors have . .8. ❑ Demolition working for me in any capacity. ac it3' employees and have workers' # - 9: Buildi addition [No workers'_ comp. insurance comp. msurance. requ 5. 0 We are a corporation and its 10.0 Electrical repairs or additions 3.0 I am a homeowner doing all work officers havexercised their . 11.0 Plumbing repairs or additions myself [No, workers' comp. right of exemption per MGL 1 �.0 Roof repairs insurance required.] t • c. 152, § 1(4); and we have no • employees. [No workers' 13.0 Other comp. insurance required} Any applicant that checks box #I must also fill out the section belowshowing their workers' compensation policy information. . • t Homeowners who submit Ibis affidavit in they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub = contractors and state whetheornot those entities have employees. If the sub- contractors empioyees, they must provide their workers' comp. policy number. ' I am an employer that is providing workers' compensation insurance for my einployeex Below is the policy and job site information. .. Insurance Company Name: . C\ C:..)S`' -.r' : e ` lhc-A . ‘4 ( AN C :h )4,_ . . . gs Policy # or Self -ins. Lic. #: k..ac. �, 4. c t � i .: r) \ Y C-' 07.) k l Expiration Date: - i t� \ ‘,'-. . Job Site Address:. `' \ \i.'`-J' `� ' S�! \-` ..` 'vt` ,, "*I'1/4.1.. C' /Stn • k`J��' . rtY telZiP: • Attach a copy of the workers'' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage. as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment; as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investinations of the DIA for insurance coverage verification. I do hereby certify under the p , ' -and pen of ury that the information provided abov . is e and correct ' — Siy• : tor r e: .rd ` ' /� �� • Date: vTP /./ , Phone #: Official use only. Do not write in this area, to be completed by city or town official Cr or Town: Permit/License # Issuing Authority (circle one): : •1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6.Other "' • Contact Person: Phone #: SECTION 8 = CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: ` Not Applicable ❑ � Name of License Holder : S j \ 1 '\ \4J License Number Address / Expiration a Signature Telephone / zit: e i� t ¢l .�t� -� w ,., Not Applicable ❑ oko Company Name Registrati tuber e'■ Address , C Expiration Da e c"4.-. -rte ■.. k,1■ U Telephone < 'n SECTION 10- WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M G L. c '152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes N til No ❑ � � - .4;„ n 50'11C-4 - 4;'4 1 ` 1.€ The current exemption for "homeowners" was extended to include Owner - occupied Dwellings of one (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person (s) who own a parcel of land on which he /she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two -year period shall not be considered a homeowner. Such "homeowner" shall submit to the Building Official, on a form acceptable to the Building Official, that he /she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. . The undersigned "homeowner" certifies and assumes responsibility for compliance with the State Building Code, City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature SECTION 5- DESCRIPTION OF PROPOSED WORK (heck .. all applicable) New House ❑ Addition Replacement Windows Alterations) ❑ Roofing Or Doors ❑ Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [[] Siding [0] Other [0] Brief Description of Proposed � Work: 1k�.�.O Alteration of existing bedroom Yes */ No Adding new bedroom Yes V No Attached Narrative ✓ Renovating unfinished basement Yes ✓ No Plans Attached Roll - Sheet a. Use of building : One Family Two Family Other b. Number of rooms in each family unit Number of Bathrooms c. Is there a garage attached? TN d. Proposed Square footage of new construction. 54V. Dimensions e. Number of stories? �'►�� . f. Method of heating? Lt \ Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction a-s acs : '�j i. Is construction within f lands? Yes No. Is construction within 100 yr. flood lain Yes J No n th 100 ft. o wet Y floodplain Depth of basement or cellar floor below finished grade 1 k. Willzbuilding conform to the Building and Zoning regulations? / Yes No I. Septic Tank City Sewer 1 Private well City water Supply SECTION 7a - OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT , as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date 1, C \l. Y\c.t sss. ��� f +v y� � ` , as Owner /Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name "'("4.7.44Yf 0/7 7 Signature of Owner /Agent Date ✓ r,. Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zon This column to be illed in by Building Depa t - (" E ' Lot Size 1 / 7.( .. w. Frontage 1 11 11 i '---, Setbacks Front 1 73 11 1 1 Side L:LJO l R: L:I[7 i R:1 Rear E20 PPM 1 1 Building Height DE Bldg. Square Footage ESA Eil % y o 1 1 1 __Open Space Footage a , 1 1 %._ . - - - - 1 - 1 $ (Lot area minus bldg & paved 1 = 1 1 1 parking) # of Parking Spaces 1 t 1- --7 /C/ 6 0 Fill: 1. (volume & Location) /// C� A. Has a Special Permit /Variance /Finding ever been issued for /on the site? ibt/ ! NO G DONT KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES 0 IF YES: enter Book Page and /or Document # I B. Does the site contain a brook, body of water or wetlands? NOj DONT KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained 0 , Date Issued: i 1 C. Do any signs exist on the property? YES © NO )S IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES 0 NO IF YES, describe size, type and location: 1 E. Will the construction activity disturb (clearing, gradi excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES 0 NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. , 411, prvi==,33.y77,4,w,.3,-,-71. ' _ cler-ci\JC-0 City of Northampton k.Ju-s Building Department ;. ,-----:,'.,,'.,,...',%,.7. -,0)7,-, .t''..',:...ttifL,,,2--,,..444,5° 0 29 7 - 51 ‘ Room 100 212 Main Street P., II,:t'1,4t-i".-:-.7.'t-----F,,;tr'T.-7,',:',.1e:41rq a '' N rthampton, MA 01060 ..1 ,, ; - ,-„1,,,,t..,4-.-:4:,,,,,,,--,,,,,,,,,-----------4,-,..,, .•;,.,:ile .. . ' ' ' ' , ., , I.' , ... ',',, ' “ .'"' ' . 587-1240 Fax 413-587-1272 ,,,,,i: 1 ,,, '_-::,:,..--,•'. - :, :r,': i' - 4)4:tit 111111111151111."- TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This Sect be • car aP i e ted b Y, °ffice , 1.1 Property Address: '' --t--4,..'=.:-Z.,•.,-, .. - ,-- -,:„ ,,, , , :....-; , .e --,,Y ,:, :, ...ljnit L ot --,-,,,-- ' - - - - --„ - ,iviap, 4 .--- ,•.-- :,, - - , -,,,. ;,,-:„.. :: , ,..,„.5,,,,,,,-0,-w ... :: ',, - `w, :.- , 3 c) .1-‘‘k)'-'-' - -' o - 4t i -- 3. 7 ,7 tta)‘0,tc ' ' -----; - • •-•-, A: — . '-,, , . ,u , • , ° , , ° ' - _ , •'-' . Vi , ' - - ,,--“, ,. : ,,4,- : - ',I:II °I-E101 Skpitricf CB '; - - ' - - - - , ., .. .. SECTION 2 -PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: c Jk. N \ (Y. 't-ACiL Name (Print) Current Mailing Address: .s... G.... J.... i Telephone Signature ' 2.2 Authorized Agent: '.) 4% --'-' IL C ; vt \( %*-- "?.S:. \ \&..(\ -4 \., \\Z . Name (Print) ckc .1 4 ‘'S r_... y.....7 - 4-4ilr Current Mailing Address: , ...... T . Signature Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS , Item Estimated Cost (Dollars) to be - - Official Use Only completed by permit applicant 1. Building .— (a) E3uilding Permit Fee D F 5-7 ' fed Total Cost of (b) Estimated Z Electrical S C) Construction from (6) a Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 5t t'n iZ+ "7 q 6. Total = (1 + 2 + 3 + 4 + 5) Check Number / 6 F Official Use Only This Section or Building Permit Number: I Signature: Bulicting Commissioner/Inspector of Buildings Date . . File # BP- 2012 -0319 APPLICANT /CONTACT PERSON HARLOW BUILDERS ADDRESS/PHONE 336 COLES MEADOW RD NORTHAMPTON (413) 586 -0465 PROPERTY LOCATION 30 HOWES ST MAP 17A PARCEL 172 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Permit Filled out /Q7sC t f/D Fee Paid Tvpeof Construction: REMOVE FRONT PORCH & CONSTRUCT 22 X 10 FAMILY ROOM ADDITION New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 052460 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON IN RMATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND /OR Special Permit With Site Plan Major Project: Site Plan AND /OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received & Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission _ Permit DPW Storm Water Management D- ition Delay 6 Signature of Building Offic al Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 30 HOWES ST BP- 2012 -0319 GIS #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 17A - 172 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: ADDITION BUILDING PERMIT Permit # BP- 2012 -0319 Project # JS- 2012- 000518 Est. Cost: $37074.00 Fee: $110.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: HARLOW BUILDERS 052460 Lot Size(sq. ft.): 7623.00 Owner: GOSNELL JONATHAN K & ANNIE CROTEAU Zoning: URB(100)/ Applicant: HARLOW BUILDERS AT: 30 HOWES ST Applicant Address: Phone: Insurance: 336 COLES MEADOW RD (413) 586 -0465 Workers Compensation NORTHAMPTONMA01060 ISSUED ON:10/19/2011 0:00:00 TO PERFORM THE FOLLOWING WORK: REMOVE FRONT PORCH & CONSTRUCT 22 X 10 FAMILY ROOM ADDITION POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace /Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 10/19/2011 0:00:00 $110.00 212 Main Street, Phone (413) 587 -1240, Fax: (413) 587 -1272 Louis Hasbrouck — Building Commissioner